9.3.1 Area and Dimension of a Building-unit
-
Minimum area of a Building-unit shall be 100 sq.m.
-
No side of the Building-unit shall be less than 9.00 m.
-
The ratio of width to the depth of the Building-unit shall not be more than 2.
-
The above condition of the ratio is not applicable if the smallest side of the Building-unit is 10.50 m or more in length and building units allocated under TP Scheme prior to this regulation.
-
Amalgamation of Building-unit abutting on a road with width equal or more than 18.00 m, shall be permitted if depth of the Building-unit shall not exceed three times the frontage of the Building-unit abutting on road.
| Sr. No. | BUILDING USE | MINIMUM AREA OF BUILDING UNIT (sq.m.) |
|---|---|---|
| 1 | High Rise Building | 1500Frontage of the plot shall not be less than 15 m |
| 2 | Primary school and High School | 1500 |
| 3 | Educational institute, community hall, marriage hall, Town hall, Assembly hall (All types of hall), cinema, theatre | 2000 |
| 4 | Fuelling station without service station | 1000 |
| 5 | Fuelling station with service station | 2000 |
| 6 | Religious places | 500(maximum built-up area shall not be more than 20% of the building unit area) |