24.1 Maximum Permissible F.S.I.
The Maximum Permissible F.S.I. shall be 4.0
F.S.I. more than 0.6 shall be available on payment of 40% of the prevalent Jantri rate.
24.2 Maximum Permissible Height
The Maximum Permissible Building Height shall be regulated according to the width of the road on which it abuts as prescribed below:
| Sr. No. | ROAD WIDTH | MAXIMUM PERMISSIBLE BUILDING HEIGHT (m) |
|---|---|---|
| 1 | 12.00 m and less than 18.00 m | 25.00 |
| 2 | 18.00 m and less than 45.00 m | 45.00 |
| 3 | 45.00 m and above | 70.00 |
24.3 Margins
24.3.1 Road Side Margins
The Road Side Margin in a Building Unit shall be regulated by the Road width it abuts on as mentioned in the table below:
| Sr. No. | ROAD WIDTH | ROAD SIDE MARGIN (m) |
|---|---|---|
| 1 | 12.00 m and up to 18.00 m | 6.00 |
| 2 | 18.01 m and up to 30.00 m | 7.50 |
| 3 | 30.01 m and up to 40.00 m | 9.00 |
| 4 | 40.01 m and more | 12.00 |
24.3.2 Minimum Side and Rear Margins
The Side and Rear Margins in a Building Unit shall be regulated by the Building Height as mentioned in the table below:
| Sr. No. | BUILDING HEIGHT | REQUIRED MARGINS (m) |
|---|---|---|
| 1 | Up to 15.00 m | 3.00 |
| 2 | 15.01 m up to 25.00 m | 4.50 |
| 3 | 25.01 m up to 45.00 m | 6.00 |
| 4 | 45.01 m up to 70.00 m | 8.00 |
24.3.3 Minimum Margin Between Buildings
Minimum distance between two buildings shall be as per the table below:
| Sr. No. | BUILDING HEIGHT | REQUIRED MARGINS (m) |
|---|---|---|
| 1 | Up to 15.00 m | 4.50 |
| 2 | 15.01 m up to 25.00 m | 6.00 |
| 3 | 25.01 m up to 45.00 m | 9.00 |
| 4 | 45.01 m up to 70.00 m | 12.00 |
If more than one buildings next to each other have different heights, margin required for the tallest building shall be applicable.
24.3.4 Margins from Common Plot
| Sr. No. | BUILDING HEIGHT | REQUIRED MARGINS (m) |
|---|---|---|
| 1 | Up to 25.00 m | 3.00 |
| 2 | Above 2500 m | 6.00 |
24.4 Internal Open Space
The minimum width of any interior open to sky space used for light or ventilation of the rooms shall be regulated based on the smaller side of this open space as follows:
| Sr. No. | BUILDING HEIGHT | MIN REQUIRED LENGTH OF SIDES OF OTS (m) |
|---|---|---|
| 1 | Up to 15.00 m | 1.80 |
GDCR 2016
| 2 | Above 15.00 m and up to 25.00 m | 2.50 |
|---|---|---|
| 3 | Above 25.00 m and up to 45.00 m | 3.00 |
| 4 | Above 45.00 m | 4.50 |
24.5 Parking
Parking spaces for vehicles shall be provided within the Building Unit for every new building and / or extension in existing building constructed for the first use and / or when the use of old building is changed to any of the uses mention in the table below.
| Sr No. | TYPE OF USE | MINIMUM PARKING SPACE REQUIRED | VISITOR'S PARKING & REMARKS |
|---|---|---|---|
| 1 | (a) Residential Building Detached / Semi Detached / Plotted Development (b) Flats / Apartments | (a) 1 Car parking- for more than 80 sq.mts and up to 300 sq.mts of Total permissible F.S.I. area. Additional 1 car parking for every 100 sq.mts. additional F.S.I. area. (b) 25 % of Total permissible F.S.I. | 10% of the required parking space |
| 2 | Residential Mixed use (residential + Commercial) | (c) For respective Residential use provided as (a) or (b) above as the case may be. (d) for respective Commercial use 50 % of Total permissible F.S.I. | 10% of the residential parking requirement and 20 % of the commercial parking. |
| 3 | Assembly building | 50 % of total permissible F.S.I. | 20 % of the required parking |
| 4 | Stadium | 1 sq.mts. per person of the total stadium capacity. | - |
| 5 | Mercantile, business, religious and institutional buildings | 50 % of total permissible F.S.I. In case of hospitals and nursing homes, additional parking for ambulance shall be provided at | 20 % of the required parking |
GDCR 2016
| the ground level. | |||
|---|---|---|---|
| 6 | Educational (a) primary school (b) Secondary and higher Secondary schools (c), colleges and coaching classes | (a) 25 % of the total utilised F.S.I. (b) 45 % of the total utilised F.S.I. (c) 40 % of the total utilised F.S.I. Facility for drop-off and pickup shall be provided within the premise | 10 % of the required parking |
24.5.1 General Requirements for Parking
-
Parking requirement for a Mixed Use development shall be calculated on prorate basis of the F.S.I. consumed specific to the different uses.
-
In cases where more parking space is requested, the Competent Authority may grant the permission for providing parking in basement or at upper floors with specific conditions.
24.6 Basement
In a Building Unit, the Basement shall be permitted on the following conditions:
1.No Basement shall be permitted in the required Road side marginal space.
2.Basement shall be permitted under common plot, internal road and internal marginal space for exclusive use of parking only.
3.Basement may be provided in one or more level.
4.The Competent Authority may permit a multi-level basement if the parking space available at ground level and in first basement (basement level-1) is not sufficient, for reasons stated in writing by applicant.
5.Maximum Height of the Basement shall be 3.80 m from finished basement floor level to finished upper level and minimum height shall be 2.80 m.
-
No able use shall be permitted in the basement.
-
Any use other than parking is permitted only in basement level-1 up to a maximum area of 15% of the total ground coverage of the basement floor. This non-parking area shall be calculated towards the computation of F.S.I..
-
No water connection or drainage connection shall be permitted in the Basement. In no case shall a connection with normal drainage line be provided in the Basement.
24.7 Intermediate Open Floor
For social gatherings, play area for children, sky-lobbies for change of elevators, water storage tank, Swimming pool and Health club, etc. Built-up and F.S.I. not to be counted.
24.8 Differently Abled People Regulation to BE Followed in All the Buildings AS Per Provision in the Chapter 27.
24.9 Uses Not Permissible
Cottage industries, light home workshop etc., lodging house boarding
House, Slaughter house, Obnoxious and hazardous uses, steel stock yard, truck terminal, saw mill, timber mart, ice factory and cold storage, junk yard, non-obnoxious and non-hazardous industries, wholesale market, ware houses, storage of perishable and inflammable goods, hospital for infectious and contagious diseases, mental hospital, jail, Dying house, etc.
Notwithstanding anything Contained in this Chapter, The Regulations mentioned in other Chapters shall be Applicable.
25 GREEN BUILDING INCENTIVES
It has been decided that the proposals for obtaining Green Building approval in respect to Building and construction projects which has obtained Green Building rating (Pre –Certification or Provisional Certification) under the rating programs of GRIHA, IGBC including LEED India, etc by integrating high level of environmental norms into their building plans, shall get priority for their consideration, out of turn, by the Expert Appraisal Committee / State level Expert Appraisal Committee, as the case may be.
| GREEN BUILDING RATINGS | INCENTIVES | ||
| IGBC | LEED | GRIHA | Rebate in Paid F.S.I |
| Silver | Silver | ** | 3% |
| Gold | Gold | *** | 5% |
| Platinum | Platinum | ***** | 7% |
The rebate shall be allowed in F.S.I.
1.All the Government and Public buildings shall compulsorily follow the Green Building Norms and shall achieve appropriate Standards
2.The building must once in 5 years get the maintenance certificate from GRIHA
- In case default and not conforming with the Green Building regulations, the applicant shall be penalized in terms of amount equivalent to the incentive given.
GDCR 2016