Table 9.1Uses Permissible For Commercial Development in Areas Other than Gamtal
Sr.No.
RoO. AD WIDTH
FLOOR
1
9 m and less than 12 m
Only Ground Floor
2
12 m and less than 18 m
Ground And First Floor
3
18 m & above
All Floors
9.2Uses Not Permissible
The development shall be regulated according to the width of the road on which it abuts subject to use zone table as follows:
Table 9.2Uses Not Permissible For Commercial Development in Areas Other than Gamtal
Sr. No.
ROAD WIDTH
USES NOT PERMISSIBLE
1
18 m & above
All educationalinstitutionsup to SSCE level
2
12m and less than 18 m
(1) High rise buildings, Cinema Hall, Meeting/ Community/ Lecture/ Town hall, Auditorium, Petrol Pump, Public establishments, Starred- hotels, College, Technical institutes, General hospital,Polyclinic
3
9 m and less than 12 m
All uses mentioned in (b) above and building with more than 13 m height (Excludinghollowplinth)
4
less than 9 m
All uses mentioned in (c) above and building with more than 10m height. Apartments/Flattype building. (Excludinghollow plinth)
Provided that these regulations shall not be applicable for authorised existing uses prior to these regulations.
9.3Minimum Area of Building Unit
9.3.1 Area and Dimension of a Building-unit
Minimum area of a Building-unit shall be 100 sq.m.
No side of the Building-unit shall be less than 9.00 m.
The ratio of width to the depth of the Building-unit shall not be more than 2.
The above condition of the ratio is not applicable if the smallest side of the Building-unit is 10.50 m or more in length and building units allocated under TP Scheme prior to this regulation.
Amalgamation of Building-unit abutting on a road with width equal or more than 18.00 m, shall be permitted if depth of the Building-unit shall not exceed three times the frontage of the Building-unit abutting on road.
Table 9.3Minimum Area Of Building Unit In Areas Other Than Gamtal
Sr. No.
BUILDING USE
MINIMUM AREA OF BUILDING UNIT (sq.m.)
1
High Rise Building
1500Frontage of the plot shall not be less than 15 m
2
Primary school and High School
1500
3
Educational institute, community hall, marriage hall, Town hall, Assembly hall (All types of hall), cinema, theatre
2000
4
Fuelling station without service station
1000
5
Fuelling station with service station
2000
6
Religious places
500(maximum built-up area shall not be more than 20% of the building unit area)
9.5Margin and Maximum Built-up Area
9.5.1 Residential and Commercial Use
9.5.1.1
The margins for all uses except for industrial building and special structures shall be as under:
Table 9.6Road Side Margins In Areas Other Than Gamtal
WIDTHOF PROPOSED ROADS(m)
MINIMUM ROAD SIDE MARGIN(m)
REMARKS
Road up to 9 m and less
3.00
(1)For the existing built up area the margins requirement may be relaxed on merits of individual case subject to other regulations. (2) Minimum side Margin shall be provided as per regulationno. 9.5.1.2.
More than 9 mand up to 12 m
4.50
More than 12 m and up to 18 m
6.00
More than 18 m and up to 40 m
7.50
More than 40 m
9.00
9.5.1.2
The minimum side (other than road side) margins and maximum built-up area on any floor for all uses except for industrial building and special structure shall be as under:
Table 9.7Margins Other Than Road Side In Areas Other Than Gamtal
Sr.No.
PLOT SIZE
MARGIN OTHER THAN ROAD SIDE
MAXIMUM BUILT-UP AREA ON ANY FLOOR
1
up to 150 sq.m.
2.25 m (anyone side)
60%
2
Above 150 sq.m. and up to 250 sq.m.
2.50 m (rear side) and 1.50 m (any one side)
50% or 90 sq.m. whicheveris more
3
Above 250 sq.m.
3.00 m in all sides except road side subject to these regulations as the case may be
45 % or 150 sq.m. whicheveris more
4
For high-rise building
0.20 H or 6.00 m, whichever is more on remainingsides
30%
9.5.1.3 Maximum Permissible F.S.I.
Table 9.8Maximum Permissible F.S.I.
Sr.No.
USE ZONE
BASE F.S.I.
CHARGABLE F.S.I.
MAXIMUM PERMISSIBLE F.S.I.
CONDITIONS
1
Residential Zone as per DP-2004
1.8
0.45
2.25
Road width ≥ 18 m
0.9
2.7
Road width ≥ 30 m
2
Proposed Residential Zone
0.6
1.2
1.8
Road width ≥ 18 m
3
Residential Zone ORR (90 m)
0.6
3.4
4.0
4
Residential Gamtal
2.0
Nil
2.0
5
Residential Gamtal Extension
1.2
Nil
1.2
6
Commercial Zone
1.8
0.45
2.25
Road width ≥ 18 m
0.9
2.7
Road width ≥ 30 m
7
Industrial Zone-General
1.0
0.5
1.5
8
Industrial Zone (Obnoxious and Hazardous)
1.0
Nil
1.0
9
Institutional zone
1.2
1.3
2.5
10
Recreational
0.15
Nil
0.15
11
Agriculture
0.15
Nil
0.15
12
Logistics Zone
1.0
0.5
1.5
13
Affordable Housing
As per UDD Guidelines
F.S.I. Permissible shall be considered as per building use and not as per use zone.
Industries shifted from the city area shall be allowed F.S.I. of 1.8 at its original place in conformity with the special policy to be framed by the Competent Authority in this regard.
9.5.1.4 Low Rise Buildings
In case of Low rise building for commercial and mixed development the margins and ground coverage shall be as under:
(a) Maximum 50% built up area of proposed ground floor shall be permitted in mixed development subject to these regulations.
(b) In case of sub division / Sub plotting of Survey no / Final Plot / Block No, the area of sub divided building unit is up to 250 sq.m., minimum 3.00 m margin shall be required along the boundary of Survey No / Final Plot / Block No and Boundary of sub divided building unit as the case may be.
(c) There shall be minimum 6.00 m clear distance between two detached low rise building/ structure.
9.5.1.5 High Rise Buildings
In the case of building units to be developed with one or more high rise buildings, the minimum margins and open space above the ground level and between the buildings shall be provided as under:
(a) margin on road side shall be 0.30 H. or 6.00 m, whichever is more.
(b) Margin other than road side shall be 0.20 H. or 6.00 m, whichever is more.
(c) Margin between two building shall be two times the margins required on remaining side as mentioned above.
Explanation
In the above regulations 'H' shall mean height of the building which shall be measured from the plot level to the highest point in the building. Provided that the height of the genuine stair- cabin, lift well, water tank and lift cabin shall not be taken into consideration in determining the total height of the building provided that the height of each , does not exceed 2.4 m. The maximum height of the parapet shall be 1.50 m and it shall also not be computed towards the height of the building.
In case of more than one semi detached high rise building, the length of common wall between any two buildings shall not be less than 50% of maximum width of the building parallel to common wall (any high rise building) joining together. Otherwise, it shall be treated as detached high rise building for the purpose of computing the margins.
9.5.2 For Industrial Use
Maximum permissible built-up area on any floor including the ground floor shall be 50% of the plot area.
There shall be clear minimum distance of 6.00 m between two detached structures for plots of more than 1000 sq.m. and 4.50 m for plots admeasuring up to 1000 sq.m.
6.00 m clear minimum margins shall be kept along the periphery of the plot used for industrial use like mills, godown, warehouses, service station with petrol pumps, motor repair garage and a building unit of 1000 sq.mts. or more to be used for industrial use. For building units less than 1000 Sq.m. used for industrial use, the minimum margins shall be 4.50 m.
However, the minimum roadside margin on roads 18.00 m wide and above shall not be less than the margin prescribed in regulation No 9.5.
9.5.3 Permissible Built UP Area in Margin
Ancillary uses such as W.C., bathroom , servant quarter, and parking garage shall be permitted in one of the corners of a rear marginal space of an individual or semidetached residential building unit(except ownership flats /tenements) subject to following conditions:
The maximum permissible area of construction shall be 16.50 sq.m. may be allowed for servant’s quarter, bath-room W.C. or closed parking having maximum dimensions 5.50 m x 3.00 m.
The maximum height of construction shall be 3.00 m with maximum plinth of 30.00 cm.
No First floor shall be permitted over such a construction.
It shall be exclusively used for the use of common utilities of the occupants use such as any residential use such as W.C., bath room, servant quarters and for parking garage etc.
It shall be considered towards calculation of maximum permissible built-up area and floor space index of the building unit.
The location of the said construction can be alternatively permitted from the rear corner up to a maximum distance of half the length of the side.
Openings of doors, windows and any type of projections shall not be permitted overlooking adjoining property. The slope of the roof of such structure shall be towards the inner side of the same building unit and away from the adjoining building unit.
Underground water tank a surface water tank up to 1.50 m in height from ground level, well a tube well and a pump-room as directed by appropriate authority with maximum size of 1.50 m x 1.50 m with a height not more than 1.80 m and electric sub-station according to the norms of D.G.V.C.L., Torrent Power or any other electricity supplying company shall be permitted in margin of a building unit.
Provided that the sub- station shall be permitted above ramp leading to celler after keeping require head way.
In case of industrial use, construction of security room to the extent of 15 Sq.m. shall be permitted (including transformer room, meter room and toilet).
In case of other industrial use; sub-station, transformer room and metre room shall have to be provided as per the norms of D.G.V.C.L., Torrent Power or any other electricity supplying company.
9.5.4 Restriction on Development in Margin
The marginal open spaces as provided in the above sub-clauses shall be kept permanently open at ground level and they shall not be used for stocking materials or loose articles for the purpose of trade or otherwise nor shall they be used for putting up fixed or movable platforms, over hanging or any other encroachments of any kind.
Decorative advertisements boards or neon sign boards may be permitted in 4.50 m margin of a building unit abutting on roads having width of 18.00 m or more with prior permission of the Competent Authority and such approval shall be given for a maximum period of three years.
The sunk-in-lower ground floor or semi-basement or basement shall not be provided in marginal space.
The boundary of the plot shall have to be demarcated by at least 0.60m parapet/compound wall/railing ,which shall not exceed 2.00 m.
The plot level may be permitted to be raised up to plinth level in cases of Building Units other than tenement buildings, ownership tenement flats, industrial and commercial units.
Security cabin with maximum size of 2.00 m X 2.00 m and a height not more than 2.40 m shall be permitted in the roadside margin.
0.60 m architectural projection shall be permitted in margins, which shall not be an extension of the slab & shall not be used for habitable purpose.
9.5.6 Projections in Margins
In any marginal open space, weather sheds projections shall be permitted up to 0.60 m at the height of 2.00 m from the floor level but not in continuation with floor slab. However it shall not be allowed to be covered in any case so as to add to the usable floor area.
In case of detached and semi-detached residential dwelling building unit, 1.00 m wide open cantilever stair with maximum 2.00 m landing space at floor level shall be permitted in the 3.00 m and above marginal space except road side margin.
9.5.7 Margins from Common Plot
3.00 m shall be required in case of low rise building.
6.00 m shall be required in case of high-rise building.
In any marginal open space, weather sheds projections shall be permitted up to 0.60 m at the height of 2.00 m from the floor level but not in continuation with floor slab. However it shall not be allowed to be covered in any case so as to add to the usable floor area.
In case of detached and semi-detached residential dwelling building unit, 1.00 m wide open cantilever stair with maximum 2.00 m landing space at floor level shall be permitted in the 3.00 m and above marginal space except road side margin.
9.4Floor Space Index(f.s.i)
9.4.1 Permissible F.S.I.
(a) The maximum permissible Floor Space Index of a building unit shall be as under:
Table 9.4Permissible F.S.I. In Areas
Sr. No.
USE ZONE
MAXIMUM PERMISSIBLE BUILT-UP
MAXIMUM PERMISSIBLE F.S.I.
REMARKS
1.
Residential
As per regulation No. 9.5.1.2
As per regulation No. 9.5.1.3
2.
Natural Growth of Village (Gamtal Extension)
As per regulation No. 9.5.1.2
As per regulation No. 9.5.1.3
Ground floor plus two upper floors or 10.00 m height whichever is less. Parking in hollow plinth should not be counted towards height.
3.
Commercial Zone
45% (low rise building) 30% (high rise buildings)
As per regulation No. 9.5.1.3
4.
Industrial
50%
As per regulation No. 9.5.1.3
5.
Starred hotels on 18.00 m and above road
45% Low rise 30% High rise
Additional FSI may be permitted on payment of an amount towards additional infrastructure charges at the rate decided by the Appropriate authority from time to time.
9.4.2 Maximum Permissible Height
The maximum height of any building should be 70.00 m from the plot level to the top of the building, except parapet not exceeding 1.50 m in height subject to other regulations.
Height of the genuine lift room shall be counted towards the building height.
9.4.2.1 Maximum Permissible Height According Road Width
Table 9.5Maximum Permissible Building Height In Areas Other Than Gamtal
Sr. No.
ROAD WIDTH (m)
MAXIMUM PERMISSIBLE BUILDING HEIGHT (m)
1
less than 9 m
10.00
2
9 m and less than 12 m
15.00
3
12 m and less than 18 m
25.00
4
18 m and less than 45 m
45.00
5
45 m and above
70.00
Height more than 40.00 m shall be permitted on payment of the charges decided by the Competent Authority.
9.4.3 Relaxation in FSI
In case of Building‐units affected by road widening or construction of new road, if the owner has already given the amenity space for public purpose, and comes for development permission again, in that case the owner may get F.S.I. from the Competent Authority for the surrendered land.
Before securing revised Development Permission on any such Building‐units, owner shall have to surrender the affected land.