Building‐units for use as Fuelling Stations shall comply with Petroleum Rules, 1976 under the Petroleum Act, 1934.
11.1 Area and Frontage
The minimum area and frontage of a Building‐unit for a Fuelling Station or Fuelling with Service Station shall be as follows:
| Sr. No. | FUELLING STATION TYPE | MINIMUM AREA OF BUILDING UNIT | MINIMUM FRONTAGE ON ROAD SIDE |
|---|---|---|---|
| 1 | Fuelling Station (without Service Station) | 1000 sq.m. | 30.00 m |
| 2 | Fuelling with Service Station | 2000 sq.m. | 30.00 m |
11.2 Location
-
Fuelling Station shall be permitted only on Road width of 18.00 m and more in any Zone.
-
The location of Fuelling Station or Fuelling with Service Station shall be at a distance of 50.00 m, away from the junction of two or more roads. The minimum distance shall be computed from the boundary line of the Building‐unit to the edge of the road.
-
In the case the Station is provided along a main road which has a service road or a marginal access road, the access to the Station should be provided from the service road or the marginal access road and not from the main road.
11.3 Maximum Permissible Ground Coverage
Maximum Permissible Ground Coverage for Fuelling Station and Fuelling with Service Stations shall be 45% of the Building‐unit including the area of the canopy.
11.4 Margins
11.4.1 For Fuelling Station
-
Road side margin from canopy to the plot boundary shall be minimum 6.00 m on all other sides, margin from canopy to the plot boundary shall be 4.50 m and 6.0mts in the case of canopy having height up to 6.00 m and more than 6.00 m from ground level respectively.
-
Marginal distance form curb site (Fuelling Pedestal) to the plot boundary towards main road shall be minimum 9.00 m and for other sides of the plot, it shall be 6.00 m.
-
Administrative building for the petrol pump shall have minimum road side margin as per planning regulation 9.5.1.1; minimum side and rear margin of 3.00 m and as given in table. Zero margins can be provided towards canopy but minimum 6.00 m clear drive way shall be provided to any curb site.
-
Minimum 6.00 m clear drive way shall be maintained between every curb site (fuelling pedestal).
-
Minimum width of access road shall be 6.00 m.
| Sr. No. | ROAD WIDTH(m) | ROAD SIDE MARGIN FOR BUILDING-UNIT AREA UP TO 2000 sq.m. AND BUILDING HEIGHT UP TO 25m (m) | ROAD SIDE MARGIN FOR BUILDING-UNIT AREA ABOVE 2000 sq.m. AND BUILDING HEIGHT UP TO 25m (m) | ROAD SIDE MARGIN FOR BUILDING-UNIT WITH HEIGHT MORE THAN 25m (m) |
|---|---|---|---|---|
| 1 | Up to 9.00 | 3.00 | 3.00 | - |
| 2 | Above 9.00 and up to 12.00 | 4.50 | 4.50 | - |
| 3 | Above 12.00 and up to 18.00 | 6.00 | 6.00 | 7.50 |
| 4 | Above 18.00 and up to 30.00 | 6.00 | 7.50 | 7.50 |
| 5 | Above 30.00 | 6.00 | 9.00 | 9.00 |
11.4.2 For Fuelling Station with Service Station
-
Road side margin from canopy to the plot boundary shall be as per Planning Regulation no 11.4.1., subject to minimum 6.00 m and all other sides shall be 6.00 m. Provision of above (2) and (4) in Planning Regulation 11.4.1 will remain the same.
-
While building of service station can have zero margins towards canopy, subject to minimum 6.00 m towards road side and 3.00 m towards other sides of the plot.
-
Clear 6.00 m drive way between curb site (Fuelling pedestal) and service station building shall be provided.
-
Minimum width of access road shall be 6.00 m.
11.5 Height
The maximum allowable height shall be 7.50 m.
11.6 Common Plot
Common Plot shall not be required.
11.7 Parking
Every Fuelling Station and Fuelling with Service Station should provide minimum parking spaces on the basis of the Building unit Area as stated in the table below:
| Sr. No. | FUELLING STATION (AREA) | MINIMUM PARKING REQUIREMENT |
|---|---|---|
| 1 | Fuelling station up to 1000 sq. m. | 3 cars and 5 two-wheelers |
| 2 | Fuelling station more than 1000 sq.m. | For every 500 sq.mts more than 1000sq.mts, additional parking for 1car and 2 two-wheelers shall be required. |
11.8 Basement
No basement shall be allowed.