This zone constitutes of Gamtals as defined and notified in survey and settlement records. Gamtal does not include new Gamtal and city survey areas. Gamtal has a traditional, organic character and compact development. This zone is identified to conserve this traditional character. It consists of Gamtal area as well as city survey ward no 1 to 12 of Surat Walled City area.
This Zone includes, areas as shown in Development Plan with primarily intended use as Residential.
8.1 Permissible Uses
Refer use zone table (Chapter 29)
8.2 Minimum Area of a Building Unit
-
Minimum area of a Building-unit shall be 18 sq.m. with no side less than 3.00 m in width.
-
Amalgamation shall be permitted and in such cases 10% of the land shall be kept open on the road side, provided amalgamation is permissible under relevant laws in force and not violative of the Act and the Stamp Duty Act, etc.
Plot less than 18 sq.m. in area allotted by SMC or government agencies before coming into force of this regulations shall be considered as minimum plot for the purpose of this provision.
8.3 Set Back
The Set back of 3.00 m from central line of existing street shall be provided where regular line of street is not prescribed.
-
The land left open as set back shall be deemed to be part of the street.
-
No set back shall be required for the building unit of area up to 100 sq.m.
-
The competent authority shall permit the F.S.I of any plot or a building unit on the basis of its original area, if the owner of such a land is prepared to release the effected land by road widening or for construction of new road without claiming any compensation thereof.
8.4 Permissible Ground Coverage
| Sr. No. | BUILDING UNIT (sq.m.) | MAXIMUM PERMISSIBLE |
|---|---|---|
| 1 | Up to 90 | 75% |
| 2 | 90 to 150 | 65% or 67.5 sq.m., whichever is more |
| 3 | 150 to 1500 | 50% or 90 sq.m., whichever is more |
| 4 | 1500 & above | 45% |
8.5 Building Height
- The maximum permissible building height shall be regulated according to the width of the road on which it abuts and as prescribed below:
| Sr. No. | ROAD WIDTH (m) | MAXIMUM PERMISSIBLE BUILDING HEIGHT (m) |
|---|---|---|
| 1 | Up to 7.50 m | Twice the width of the abutting road or open space |
| 2 | Above 7.50 m and up to 12.00 m | 15.00 |
| 3 | 12.00 m and above | 25.00 |
- For Building‐units abutting a khadki, chowk, fadia, alley or cul‐de‐sac, the maximum permissible Building Height shall be regulated as per the width of the road leading to such khadki, chowk, fadia, alley or cul‐de‐sac as mentioned in table above.
8.6 Open‐to‐sky Space
Open‐to‐sky space shall be provided for natural light and ventilation in conformity with the following Regulations. The location and dimensions of the open space shall be based on the dimensions of the Building‐unit and the proposed building height, whichever is higher shall be applicable.
8.6.1 Regulation Based on Building Dimensions
-
For any Building having depth of 9.00 m or more from its front open space, an open‐to‐sky space with area of 5.60 sq.m. with no side less than 1.80 m at plinth level shall be provided for every 9.00 m depth. If the width of the Building is up to 4.50 m, then the size of this open to sky space shall be 3 sq.m. with no side less than 1.50 m.
-
If the depth of the Building does not exceed 18.00 m and has openings at least on two sides over a street or open to sky space of 2.40 m or more in width, then above provision shall not be applicable.
-
In case additional open‐to‐sky space is provided beyond the minimum requirements, it shall be counted towards the computation of the F.S.I.
8.6.2 Regulation Based on Building Height
- Minimum width of any interior open‐to‐sky space, which is used for light and ventilation of the room, shall be regulated on the basis of the building height as per as per table below:
| Sr. No. | BUILDING HEIGHT (m) | MINIMUM WIDTH (m) |
|---|---|---|
| 1 | Up to 10m | 3.00 |
| 2 | Above 10 m and up to 15 m | 3.00 |
| 3 | Aove 15 m | 4.00 |
2.This open‐to‐sky space shall be provided at the level at which the light or ventilation is borrowed.
- For the purpose of the above Regulations, the depth of the room shall not be more than three times the width of the room which abuts on the air space.
8.6.3 General Requirement for Open‐to‐sky Space
-
Every exterior or interior, open space shall be kept free from any erection thereon and shall be kept open to sky with suitable and sufficient access.
-
No open drain except for rain water shall be constructed in any open space required by these Regulations.
-
Every such interior or exterior open air space, unless the latter is a street, shall be maintained for the benefit of such building exclusively and shall be entirely within the owner's own premises.
8.7 Common Plot
Common plot shall be required for building units of area 2000 sq.m. or more at the rate of 10% of the area of building unit.
8.7.1 General Requirements
General requirements for common plot shall be as provided in regulation no 10.
8.8 Parking
-
Parking spaces for vehicles shall be provided within the Building‐unit for every new Building and /or extension in existing building constructed for the first use and /or when the use of old building is changed to any of the uses mentioned in Planning Regulation 29.
-
For Building‐unit with area less than 60 sq.m., parking shall not be required. For Building‐units with area more than 30 sq.m., parking shall be provided as per Planning Regulation 16..
-
In case it is not feasible to provide the required parking as per Regulations due to any constraint, the Competent Authority may levy fees for such deficit parking. This fee shall be decided by the Competent Authority and revised from time to time.
8.9 Basement
-
No basement shall be permitted within required set back area.
-
All-round margin of 1.00 m shall have to be kept from adjoining property for construction of basement.
-
Basement shall be allowed for parking if the area of Building‐unit is more than 600 sq.m.
-
For Building‐units with area more than 1500 sq.m., basement shall be allowed for parking at two levels.
8.10 Floor Space Index
The maximum permissible F.S.I. of a building unit shall be 2.
8.10.1 Relaxation in F.S.I.
In case of Building‐units affected by road widening or construction of new road, the owner may claim compensation or F.S.I. from the Competent Authority for the surrendered land. In case of FSI, the Competent Authority shall permit the FSI of any such land / plot or Building‐unit on the basis of the original boundary of the Building Unit. This is subject to conformity with all other requirements mentioned in these Regulations as per the new boundary. Before securing Development Permission on any such Building‐units, owner shall have to surrender the affected land.
8.11 Addition to Existing Structure
1.The addition shall comply with all Regulations for construction of a new building.
-
No addition or extension to a building shall be allowed unless the addition or extension is such as would be permissible if the whole building were reconstructed from the plinth with the open spaces required under the Regulations applicable to the site of the building at the time of the proposed addition or extension.
-
No addition or extension to a building shall be allowed which would diminish the minimum extent of open air space which is required by the Regulations applicable to the site of the building at the time of the proposed addition or extension.
8.12 Plinth
Minimum plinth height of 0.45 m from ground level shall be provided.
8.13 Projections on Set Backs
8.13.1 Weather Shed
In any marginal open space, weather sheds projections shall be permitted up to 0.60 m at the height of 2.00 m and above from the floor level. However, it shall not be allowed to be covered in any case so as to add to the usable floor area.
8.13.2 Door/window Shutters and Steps
-
No shutters of any doors or windows of any building shall be allowed to open on the street.
-
Projections of steps shall not be permitted on set- backs, streets or roads.