22.1 Maintenance of Buildings
22.1.1 Responsibility for Maintenance of Buildings
It shall be the responsibility of the Owner of a building to ensure that the building is kept in good repair, such that its structural stability is not compromised.
For the purpose of this regulation, buildings will be classified in two categories:
Class 1: All types of framed structures, factory buildings, cinema, auditorium and other public institutional buildings, schools and college buildings, hostels.
Class 2: Masonry‐walled residential buildings constructed with height more than 9.00 m.
22.1.2 Periodic Inspection and Maintenance Certificate
All buildings in Class 1 and Class 2 shall require periodic inspection by a SEOR at intervals specified in Schedule 12. The SEOR shall inspect the building to ascertain and certify to the Competent Authority, that the building’s structural stability has not been compromised due to lack of adequate maintenance along with a Structural Inspection Report. It shall be the responsibility of the Owner to submit the certificate to the Competent Authority no later than one month after the date on which inspection is due.
22.2 Maintenance of Lifts and Escalators
22.2.1 Responsibility for Maintenance of Lifts and Escalators
It shall be the responsibility of the Owner of a building to ensure that lifts and escalators in the building are kept in good repair, such that their use is safe.
22.2.2 Maintenance Protocol
- Maintenance protocol for lifts and escalators shall be as per:
(a) IS: 1860 – 1980 Code of Practice for Installation, Operation and Maintenance of Electric Passenger and Goods Lift;
(b) IS: 6620 – 1972 Code of Practice for Installation, Operation and Maintenance of Electric Service Lifts; and
(c) IS: 4591 – 1968 Code of Practice for Installation and Maintenance of Escalators.
-
The lift installation should receive regular cleaning, lubrication adjustment and adequate servicing by authorised competent persons at such intervals as the type of equipment and frequency of service demand.
-
In order that the lift installation is maintained at all times in a safe condition, a proper maintenance schedule shall be drawn up in consultation with the lift manufacturer and rigidly followed.
-
A log book to record all items relating to general servicing and inspection shall be maintained.
-
The electrical circuit diagram of the lift with the sequence of operation of different components and parts shall be kept readily available for reference by persons responsible for the maintenance and replacement, where necessary, to the satisfaction of the Competent Authority.
-
Any accident arising out of operation of maintenance of the lifts shall be duly reported to the Competent Authority.
22.3 Maintenance of Fire Prevention and Safety Provisions
It shall be the responsibility of the Owner of a building to ensure that all the fire prevention and safety provisions in a building are kept in good working condition at all times. The fire prevention and safety provisions shall include all the fixed fire protection systems, installations, fire extinguishers, first aid kits, fire lifts and escape stairs provided in the building.
22.3.1 Periodic Inspection and Maintenance Certificate
For all buildings with height more than 15mts, the Fire Protection Consultant on Record shall inspect the building at intervals not more than 12 months to ascertain and certify to the Competent Authority that the building’s fire safety has not been compromised due to lack of adequate maintenance.