Annexure A1 Form for Application for Construction of Building or Layout of Building / Group Housing Application for Permission for Construction of Building or Layout of Building / Group Housing under Section 44 of the Maharashtra Regional and Town Planning Act, 1966. (requisite Court Fee Stamp)
To,
The Authority,
Special Planning Authority for .... ... ... ... ... Integrated Industrial Area.
I intend to carry out the under mentioned development in the site to erect/ to re-erect/ to demolish/ to make material alteration in the building on/ in Plot No. ...., at .... Integrated Industrial Area situated at Road/ Street .... in accordance with Section 44 of the Maharashtra Regional and Town Planning Act, 1966.
I forward herewith the following plans and statements, whichever applicable (Item 1 to 6), in quadruplicate, signed by me (Name in block letters) .... ... ... ... ... ... and the Architect / Licensed Engineer / Structural Engineer / Supervisor, (License No.... ... ... ... ), who has prepared the plans, designs and a copy of other statements /documents as applicable (Item 7 to 10).
(1) Key Plan (Location Plan);
(2) Site Plan (in quadruplicate) of the area proposed to be developed;
(3) Sub-division/Layout Plan
(4) a detailed building plan showing the plan, section and elevations of the proposed development work;
(5) Service Plan
(6) Particulars of development in Form enclosed (to be submitted for development other than individual buildings);
(7) An extract of record of rights, property register card (any other document showing ownership of land to be specified) along with consent of co-owners where third party interest is created.
(8) Attested copy of receipt of payment of scrutiny fees;
(9) Latest property tax receipt;
(10) No Objection Certificate, wherever required.
I request that the proposed development/ construction may be approved and permission accorded to me to execute the work.
Signature and Name Signature of
of the Licensed Owner
Surveyor/Architect Name of Owner
Address of Owner
Dated
भाग एक (को.वि.पु.)----१७अ
महाराष्ट्र शासन राजपत्र, भाग एक-कोकण विभागीय पुरवणी, गुरुचार ते बुथवार, ऑगस्ट १३-१९, २०१९/श्रावण २२-२८, शके १९३७
Form Giving Particulars of Development (construction of Building or Layout of Building / Group Housing) (part of Annexure A-1, Item 6)
01 (a) (i) Full Name of Applicant .... .... .... ....
(ii) Address of applicant .... .... .... ....
(iii) e-mail ID .... .... .... ....
(iv) Mobile No. .... .... .... ....
(b) Name and address of Architect/ Licensed Engineer/ Structural Engineer/ Supervisor employed .... .... .... ....
(c) No. and date of issue of License .... .... .... ....
02 Is the plot affected by any designations or road lines? If yes, are these correctly and clearly marked on the block plan? .... .... ....
03 *(a) What is the total area of the plot according to the document for property transfer (Lease Deed/ Conveyance Deed)? .... .... ....
*(b) Does it tally with the Record of Rights? .... .... ....
*(c) What is the actual area available on site as measured by the Architect/ Licensed Engineer/ Structural Engineer/ Supervisor? .... .... ....
(d) Is there any deduction in the original area of the plot on account of road lines or designations? .... .... ....
State the total area of such deductions. .... .... ....
(e) If so, what is the net area? .... .... ....
NOTE: ABOVE DETAILS SHALL ALSO BE MENTIONED ON BUILDING PLAN SUBMITTED FOR APPROVAL
04 Are all plans enclosed as required under Regulation No.8.2? .... .... ....
05 (a) What is the plot number in the approved layout? .... .... ....
(b) State the sanction number and date of sub-division / layout .... .... ....
06 (a) In what zone does the plot fall? .... .... ....
(b) What is the permissible Floor Space for the plot as per deed of transfer of property? .... .... ....
07 (a) Is the use of every room in the proposed work marked on the plans? .... .... ....
(b) Is it in accordance with the regulations? .... .... ....
(c) What industrial classification does it fall under? Give reference to relevant 'Principal Regulations' number. .... .... ....
(c) Does the use of the building, fall in the category of Special Types of buildings like, cinema halls, theatres assembly halls, stadia, buildings for religious purpose, hospital buildings, educational buildings, markets and exhibition halls etc.? .... ....
08 If the work is in connection with an industry: -
(a) Please briefly describe the main and accessory process. .... .... ....
* The permission shall be based on the area whichever is minimum.
महाराष्ट्र शासन राजपत्र, भाए एक-कोकण विभागीय पुरवणी, गुरुवार ते बुधवार, ऑगस्ट १३-१९, २०१५/शावण २२-२८, शके १९३७
(b) Please state the maximum number of workmen and the total horse power likely to be employed per shift in the factory.
Form of Certificate to BE Signed by the Architect/ Licensed Engineer/ Structural Engineer/ Supervisor Employed by the Applicant
Certificate
I, (… … … … Name … … … … ...) have been employed by the applicant as his Architect / Licensed Engineer / Structural Engineer / Supervisor. I have examined the boundaries and the area of the plot and I do hereby certify that I have personally verified and checked all the statements made by the applicant (who is the owner/ lessee in possession of the plot) as in the above form and found them to be correct.
Date: ....
Signature of Architect/ Licensed Engineer/ Structural Engineer/ Supervisor
EXISTING BUILDINGS TO BE RETAINED [SR. No. 10 (A) (iii)]
Existing Building No.
Floor No.
Area
Total Floor Area of Existing Building
Use / Occupancy of Floors.
(1)
(2)
(3)
(4)
(5)
FORM OF STATEMENT 2PROPOSED BUILDING [SR. No. 10 (b)]
Building No.
Floor No.
Area
Total Floor Area of Proposed Work
Use / Occupancy of Floors.
(1)
(2)
(3)
(4)
(5)
महाराष्ट्र शासन राजपत्र, भाग एक-कोकण विभागीय पुरवाणी, गुरुवार ते बुथवार, ऑगस्ट १३-१९, २०१५/शावण २२-२८, शके १९३७
Proforma 1
(at Right Hand Top Corner of Site/ Building Plan at Floor 1 Level)
Square Meters
A
AREA STATEMENT
1
Area of plot
2
Floor Space Permissible as per Base F.S.I.
3
Additional Floor Space allotted by 'Developer'
4
Permissible Total Floor Space = (2+3)
(c) Does the proposal constitute relocation of an existing industry? If so, give the name and address of existing industry
(d) Will the building be at 23 m. away from the boundary of a residential and commercial zone?
(e) Nature and quantum of industrial waste/ effluents and method of disposal
09 (a) What is the: -
(i) prescribed width of road on which plot is fronting?
(ii) If the plot abuts on two or more streets, give information in respect of all the streets.
(b) What is the height of the building above the average ground level of the plot?
(c) Does it comply with the Regulation No.17.5?
10 (a) If there are existing structures on the plot: -
(i) Are they correctly marked and numbered on the site plan?
(ii) Are those proposed to be immediately demolished hatched in yellow colour?
(iii) What is the plinth area and total floor area of all existing structures to be retained?
(Please give details conforming to the plan submitted)
(b) What is the plinth area and total floor area of the proposed work? (Please give details conforming to the plan submitted)
11 (a) Please state the plinth area and total floor area, existing and proposed
(total of Item No. 10 (a) (iii) and 10 (b))
(b) Please state the overall F.S.I. (shall not exceed 1.0) (Item 11 (a) divided by Item 6 (b))
(c) Is the Building proposed with setbacks on upper floors?
12 (a) What is the width of the front open space?
If the building abuts two or more streets, does the front open space comply with Regulation No.25?
(b) Which sub-regulation of Regulation No.25 is applicable for the front open spaces?
Does the front open space comply with that regulation?
13 What is the distance from the centre line of the street? Does it comply with the rules
14 (a) What is: -
(i) the width of the side open space (s)?
(ii) the width of the rear open space (s)?
(iii) the distance between buildings?
(b) Are there two or more wings to the buildings?
If so, are the open spaces according to that required for the highest wing?
15 (a) What are the dimensions of the inner or outer chowk?
महाराष्ट्र शासन राजपत्र, भाग एक-कोकेण विधानीय पूरवणी, गुल्दार ते बृथवार, ऑगस्ट १३-१९, २०९५/श्राण २२-२८, शके १९३७
(b) (i) Is (are) room (s) dependent for its (their) light and ventilation on the chowk?
If so, are the dimensions of the chowk as required for the highest wing of the building?
(ii) If not, is the area equal to the square of 1/5th of the height of the highest wall abutting the chowk as per Regulation No.17.2.1 (c)?
16 If the height of the building is more than 15 meters above the average ground level, is provision for lifts made?
(a) If so, give details of lift: -
Type Passenger Capacity No. of Lifts Type of Doors
(1) (2) (3) (4)
(b) Details of Fire Lift .... .... .... ....
17 (a) Does the building fall under purview of Regulation No.8.2.6.1?
(b) If so, do the proposed fire protection requirements conform to Part III of the 'Principal Regulations'?
(c) If not, give reasons for non conformity: -
(i)
(ii)
(iii)
18 (a) (i) What are the requirements of parking spaces under the Regulations?
(ii) How many are proposed?
(iii) How many lock up garages are proposed?
(b) (i) Are loading-unloading spaces necessary?
(ii) If so, what is the requirement?
(iii) How many are proposed?
19 (a) (i) What are the maximum widths of balconies?
(ii) Will they reduce the required open spaces to less than the provisions of Regulations?
(iii) Do they serve as a passage to any part of the building?
(iv) What is their total area?
(b) What is the maximum width of weather frames, Sunshades (Chajja), Sun breakers, cornice, eaves or other projection?
(c) (i) Are any porches / Canopies proposed?
(ii) Are they in compliance with Regulation No.17.4.1(c)?
20 (a) What is the width of the means of access?
(b) Will it be paved, drained & kept free of encroachment?
21 (a) Is recreational open space provided as required under Regulation No.15.3.1 & 15.4.1?
(b) Is any structure proposed in the recreational open space? If so, is it as per regulation?
महाराष्ट्र शासन राजपत्र, भाए एक-कोकण विभागीय पुरवणी, गुरुवार ते बुधवार, ऑगस्ट १३-१९, २०१५/शावण २२-२८, शके १९३७
22 (a) Are any accessory buildings proposed? If so, for what purpose?
(b) What are their heights?
(c) Are they 7.5 m away from the street or front boundary and if located within the open spaces, 1.5 m from other boundary?
(Regulation no. 17.4.1 (e) and 19.7)
(d) Is their area calculated in F.S.I.? .... .... .... ....
23 (a) What is the proposed height of the compound / boundary wall?
(b) Is it at a junction?
(c) Is it in compliance with Regulation No.19.14? .... .... .... ....
24 (a) Does the proposal fall under the category of tower like structures vide Regulation No. 25.5? If so, does it comply with the requirements thereof?
(b) Is the proposal in the Air Port Zone? If yes, does it conform to restrictions?
(c) Is a "No. Objection certificate" for height obtained?
25 Does the proposal fall in any of the restricted zones?
26 (a) Does any natural watercourse pass through the land under development?
(b) Is necessary set back provided as per Regulation No. 13.1(b)? .... .... ....
27 Is the plinth level proposed to be above the level of the surrounding ground?
28 The details of the materials to be used in construction with specifications as below:
Roofs .... .... .... ....
Floors .... .... .... ....
Walls .... .... .... ....
Columns .... .... .... ....
Any other material .... .... .... ....
29 The number of water closet, urinals, kitchen sinks, wash basins, both to be provided are as follows:
Waterclosets
Baths
Urinals
WashBasins
KitchenSinks
Existing
....
....
....
....
....
Proposed
....
....
....
....
....
30 Details of the source of water to be used in the construction .... .... .... ....
31 Distance from the sewer .... .... .... ....
32 How much land belonging to 'Developer' will be used for stacking building material?
33 Has provision of tenements for EWS / LIG been made as required under regulation no. 15.6 (3)?
34 Please explain in detail in what respect the proposal does not comply with the Development Control Regulations and the reasons therefor, attaching a separate sheet, if necessary. .... .... ....
I hereby declare that I am the owner / lessee in possession of the plot on which the work is proposed and that the statements made in this form are true and correct to the best of my knowledge.
महाराष्ट्र शासन राजपत्र, भाग एक-कोकण विभागीय पुरवणी, गुक्वार ते बृथवार, ऑगस्ट १३-१९, २०१५/श्रावण २२-२८, शके १९३७
5
Existing Floor Space
6
Proposed Floor Space
7
Excess Balcony Area included in Floor Space(As per B (c) Below)
*8
Total Floor Space consumed = (5 + 6 + 7)
*9
F.S.I. Consumed (8 / 4) (shall not exceed 1.0)
B
BALCONY AREA STATEMENT
(a)
Permissible Balcony Area on all Floors (see regulation no.17.4.1 (c))
(b)
Proposed Balcony Area on all Floors
(c)
Excess Balcony Area on all Floors = [(b) - (c)]
C
PARKING STATEMENT
(a)
Garages Permissible .... ... ... ... ...
Garage Proposed .... ... ... ... ... ... ...
(b)
Type
Parking Required
Parking Proposed
Car
Scooter/ Motorcycle
Cycle
Visitors
*D
LOADING/ UNLOADING SPACES
(a)
Loading/ Unloading required
(b)
Total Loading / Unloading Provided
E
Provision of tenements for EWS / LIG
भाग एक (को.वि.पु.)---१८
महाराष्ट्र शासन राजपत्र, भाग एक-कोकण विभागीय पुरवणी, गुरुचार ते बुधवार, ऑगस्ट १३-१९, २०१५/श्रावण २२-२८, शके १९३७
PROFORMA 2
(AT RIGHT HAND BOTTOM CORNER OF PLANS / BELOW PROFORMA 1)
Contents of Sheet
Stamps of Approval of Plans
*CERTIFICATE OF AREACertified that the plot under reference was surveyed by me on ... ... ... and the dimensions of sides etc. of plot stated on plan are as measured on site and the area so worked out tallies with the area stated in document of Ownership.Signature of Architect/Licensed Engineer/ Structural Engineer/ Supervisor.
Description of Proposal & property:Name of Owner:
Job No.
Drawing No.
Scale
Drawn By
Checked By
North Line
महाराष्ट्र शासन राजपत्र, भाग एक-कोकण विभागीय पुतुवणी, गुरुवार ते बृधवार, ऑगस्ट १३-१९, २०१५/शावण २२-२८, जके १९३७