27.1. All materials and workmanship shall be of good quality conforming generally to accepted standards of Public Works Department of Maharashtra and Indian Standard Specifications and Codes as included in Part 5 - Building Materials and Part 7 - Construction Practices and Safety of National Building Code of India, amended from time to time.
27.2. All borrow pits dug in the course of construction and repair of buildings, roads, embankments etc. shall be deep and connected with each other in the formation of a drain directed towards the lowest level and properly stopped for discharge into a river, stream, channel or drain and no person shall create any isolated borrow pit which is likely to cause accumulation of water which may breed mosquitoes.
Chapter 5Structural Safety, Water Supply, Drainage & Sanitary Requirements, Outdoor Display and Other Services
26.0 Structural Design
26.1. The structural design of foundations, elements made of masonry, timber, plain concrete; reinforced concrete, pre-stressed concrete and structural steel shall be carried out in accordance with Part 6. Structural design Section 1-Loads, courses and effects, Section 2- Soils and Foundation, Section 3— Timber and Bamboo, Section 4- Masonry, Section 5- Concrete, Section 6- Steel, Section-7 Prefabrication systems building and mixed / composite construction of National Building Code of India, amended from time to time.
31.1General
There should be at least one water tap and arrangement for drainage in the vicinity of each water closet or group of water closets in all the buildings.
(a) Each family dwelling unit on premises (abutting on a sewer or with a private sewage disposal system) shall have, at least, one water closet and one kitchen type sink. A bath or shower shall also be installed to meet the basic requirement of sanitation and personal hygiene.
(b) All other structures for human occupancy or use on premises, abutting on a sewer or with a private sewage disposal system, shall have adequate sanitary facilities, but in no case less than one water-closet and one other fixture for cleaning purposes.
31.2For Residences
(a) Dwelling with individual convenience shall have at least the following fitments:
i) One bathroom provided with a tap and a floor trap;
ii) One water-closet with flushing apparatus with an ablution tap; and
iii) One tap with a floor trap or a sink in kitchen or washing place.
(b) Dwelling without individual conveniences shall have the following fitments:
i) One water tap with floor trap in each tenement;
ii) One water closet with flushing apparatus and one ablution tap, bath for every two tenements; and
iii) One bath with water tap and floor trap for every two tenements.
R T, , T , 3 3-, 2/ -, 3
28.0Alternative Materials, Methods of Design and Construction and Tests
28.1. The provision of the regulations are not intended to prevent the use of any material or method of design or construction not specifically prescribed by the regulations, provided any such alternative has been approved.
28.1.1. The provision of these regulations is also not intended to prevent the adoption for architectural planning and layout conceived as an integrated development scheme.
28.2. The authority may approve any such alternative provided it is found that the proposed alternative is satisfactory and conforms to the provisions of relevant parts regarding material, design, and construction and that material, method or work offered is, for the purpose intended, at least equivalent to that prescribed in the rules in quality, strength, compatibility, effectiveness, fire rating and resistance, durability and safety.
28.3 Tests: Whenever there is insufficient evidence of compliance with the provisions of the regulations of evidence that any material or method of design or construction does not conform to the requirements of the rules or in order to substantiate claims for alternative materials, design or methods of construction, the Authority may require tests sufficient in advance as proof of compliance. These tests shall be made by an approved agency at the expense of the owner.
7 (可.何.y.)----84
HER T, - , T , 3 3-, R0/ R-, T 30
28.3.1 Test method shall be as specified by the regulations for the materials or design or construction in question. If there are no appropriate test methods specified in the regulations, the Authority shall determine the test procedure. For methods of tests for building materials; reference may be made to relevant Indian standards as given in the National Building Code of India published by the Bureau of Indian Standards. The latest version of the National building Code of India shall be taken into account at the time of enforcement of these rules.
28.3.2 Copies of the results of all such tests shall be retained by the authority for a period of not less than two years after the acceptance of the alternative material.
29.0 BUILDING SERVICES
29.1. The planning, design and installation of electrical installations, air-conditioning and heating works shall be carried out in accordance with Part 8 - Building Services, Section 2- Electrical and allied Installations, Section 3 - Air Conditioning, heating and mechanical ventilation of National building Code of India, amended from time to time.
29.2. The planning design including the number of lifts, type of lifts, capacity of lifts depending on occupancy of building; population on each floor based on occupant load, height of building shall be in accordance with Section - 5 installation of Lifts and Escalators of National Building Code of India, amended from time to time. In existing buildings, in case of proposal for one additional floor, existing lift may not be raised to the additional floor.
29.2.1 Maintenance of Lift in working order: The lifts shall be maintained in working order.
30.0 WATER SUPPLY, DRAINAGE AND SANITARY REQUIREMENTS.
30.1. The planning, design, construction and installation of water supply, drainage and sanitation and gas supply systems shall be in accordance with the provisions of Part 9 - Plumbing Services - Section 1 Water Supply, Drainage and Sanitation, Section 2 – Gas supply of National Building Code of India as amended from time to time.
30.2. Requirements of water supply in building.
The total requirements of water supply shall be calculated based on the population as given in Table 20 below:
Table 20Occupancy Type & Occupant Load
Occupancy
Basis
Residential Building
5 persons per tenement
Other Buildings
No. of persons on occupant load and area of floors given in Error! Reference source not found.
30.2.1 The requirements of water supply for various occupancies shall be as given in Table 21 to Table 23 or as specified by the Authority from time to time.
Table 21Per Capita Water Requirements for Various Occupancies/Uses
Sr. No.
Type of Occupancy
Consumption per head per day (in liters)
1
Residential:
(a) in living units
135
(b) Hotels with lodging accommodation (per bed)
180
R , , T , 3 3-, 2/ -, 3
Sr. No.
Type of Occupancy
Consumption per head per day (in liters)
2
Educational:
(a) Day Schools
45
(b) Boarding Schools
135
3
Institutional (Medical Hospitals):
(a) No. of beds not exceeding 100
340
(b) No. of beds exceeding 100
450
(c) Medical quarters and hostels
135
4
Assembly-Cinema theatres, auditorium etc. (per seat of accommodation)
15
5
Government and Semi-public business
45
6
Mercantile (Commercial):
(a) Restaurants (per seat)
70
(b) Other business buildings
45
7
Industrial:
(a) Factories where bathrooms are to be provided
45
(b) Factories where no bath-rooms are required to be provided
30
8
Storage (including warehousing)
30
9
Hazardous
30
10
Intermediate / Stations (excluding mail and express stops)
45 (25)*
11
Junction Stations
70 (45)*
12
Terminal / Stations
45
13
International and domestic Airports
70
(i) * The value in parenthesis is for stations where bathing facilities are not provided.
(ii) The number of persons for Sr. No. (10) to (13) shall be determined by the average number of passengers handled by the station daily. Due consideration may be given to the staff and workers likely to use the facilities
Table 22Flushing Storage Capacities
Sr. No.
Classification of building
Storage capacity
(1)
(2)
(3)
1
Tenements having common convenience
900 liters per W.C. seat
2
Residential premises other than tenements having common convenience
270 liters for one W.C. seat and 180 liters for each additional seat in the same flat
3
Factories and Workshops
900 liters per W.C. seat and 180 liters per urinal seat
4
Cinemas, public assembly halls, etc.
900 liters per W.C. seat and 350 liters per urinal seat
(可..-843
HER T, - , T , 3 3-, R0/ R-, T 30
Table 23Domestic Storage Capacities
Sr. No.
No. of Floors
Storage Capacity
Remarks
(1)
(2)
(3)
(4)
For premises occupied as tenements with common conveniences
1
Floor (Ground)
NIL
Provided no down take fittings are installed
2
Floors 1, 2, 3, 4, 5 and upper floors
500* liters per tenement
For premises occupied as Flats or blocks
1
Floor (Ground)
NIL
Provided no down take fittings are installed
2
Floors 1, 2, 3, 4, 5 and upper floors
500* liters
Subject to provisions of water supply and drainage rules.
NOTE 1: If the premises are situated at a place higher than the road level in the front of the premises, storage at ground level shall be provided on the same line as on floor 1.
NOTE 2: The above storage may be permitted to be installed provided that the total domestic storage calculated on the above basis is not less than the storage calculation on the number of down take fittings according to the scales given below: