Chapter 5Structural Safety, Water Supply, Drainage & Sanitary Requirements, Outdoor Display and Other Services
26.0 Structural Design
26.1. The structural design of foundations, elements made of masonry, timber, plain concrete; reinforced concrete, pre-stressed concrete and structural steel shall be carried out in accordance with Part 6. Structural design Section 1-Loads, courses and effects, Section 2- Soils and Foundation, Section 3— Timber and Bamboo, Section 4- Masonry, Section 5- Concrete, Section 6- Steel, Section-7 Prefabrication systems building and mixed / composite construction of National Building Code of India, amended from time to time.
27.0Quality of Materials and Workmanship
27.1. All materials and workmanship shall be of good quality conforming generally to accepted standards of Public Works Department of Maharashtra and Indian Standard Specifications and Codes as included in Part 5 - Building Materials and Part 7 - Construction Practices and Safety of National Building Code of India, amended from time to time.
27.2. All borrow pits dug in the course of construction and repair of buildings, roads, embankments etc. shall be deep and connected with each other in the formation of a drain directed towards the lowest level and properly stopped for discharge into a river, stream, channel or drain and no person shall create any isolated borrow pit which is likely to cause accumulation of water which may breed mosquitoes.
28.0Alternative Materials, Methods of Design and Construction and Tests
28.1. The provision of the regulations are not intended to prevent the use of any material or method of design or construction not specifically prescribed by the regulations, provided any such alternative has been approved.
28.1.1. The provision of these regulations is also not intended to prevent the adoption for architectural planning and layout conceived as an integrated development scheme.
28.2. The authority may approve any such alternative provided it is found that the proposed alternative is satisfactory and conforms to the provisions of relevant parts regarding material, design, and construction and that material, method or work offered is, for the purpose intended, at least equivalent to that prescribed in the rules in quality, strength, compatibility, effectiveness, fire rating and resistance, durability and safety.
28.3 Tests: Whenever there is insufficient evidence of compliance with the provisions of the regulations of evidence that any material or method of design or construction does not conform to the requirements of the rules or in order to substantiate claims for alternative materials, design or methods of construction, the Authority may require tests sufficient in advance as proof of compliance. These tests shall be made by an approved agency at the expense of the owner.
7 (可.何.y.)----84
HER T, - , T , 3 3-, R0/ R-, T 30
28.3.1 Test method shall be as specified by the regulations for the materials or design or construction in question. If there are no appropriate test methods specified in the regulations, the Authority shall determine the test procedure. For methods of tests for building materials; reference may be made to relevant Indian standards as given in the National Building Code of India published by the Bureau of Indian Standards. The latest version of the National building Code of India shall be taken into account at the time of enforcement of these rules.
28.3.2 Copies of the results of all such tests shall be retained by the authority for a period of not less than two years after the acceptance of the alternative material.
29.0 BUILDING SERVICES
29.1. The planning, design and installation of electrical installations, air-conditioning and heating works shall be carried out in accordance with Part 8 - Building Services, Section 2- Electrical and allied Installations, Section 3 - Air Conditioning, heating and mechanical ventilation of National building Code of India, amended from time to time.
29.2. The planning design including the number of lifts, type of lifts, capacity of lifts depending on occupancy of building; population on each floor based on occupant load, height of building shall be in accordance with Section - 5 installation of Lifts and Escalators of National Building Code of India, amended from time to time. In existing buildings, in case of proposal for one additional floor, existing lift may not be raised to the additional floor.
29.2.1 Maintenance of Lift in working order: The lifts shall be maintained in working order.
30.0 WATER SUPPLY, DRAINAGE AND SANITARY REQUIREMENTS.
30.1. The planning, design, construction and installation of water supply, drainage and sanitation and gas supply systems shall be in accordance with the provisions of Part 9 - Plumbing Services - Section 1 Water Supply, Drainage and Sanitation, Section 2 – Gas supply of National Building Code of India as amended from time to time.
30.2. Requirements of water supply in building.
The total requirements of water supply shall be calculated based on the population as given in Table 20 below:
Table 20Occupancy Type & Occupant Load
Occupancy
Basis
Residential Building
5 persons per tenement
Other Buildings
No. of persons on occupant load and area of floors given in Error! Reference source not found.
30.2.1 The requirements of water supply for various occupancies shall be as given in Table 21 to Table 23 or as specified by the Authority from time to time.
Table 21Per Capita Water Requirements for Various Occupancies/Uses
Sr. No.
Type of Occupancy
Consumption per head per day (in liters)
1
Residential:
(a) in living units
135
(b) Hotels with lodging accommodation (per bed)
180
R , , T , 3 3-, 2/ -, 3
Sr. No.
Type of Occupancy
Consumption per head per day (in liters)
2
Educational:
(a) Day Schools
45
(b) Boarding Schools
135
3
Institutional (Medical Hospitals):
(a) No. of beds not exceeding 100
340
(b) No. of beds exceeding 100
450
(c) Medical quarters and hostels
135
4
Assembly-Cinema theatres, auditorium etc. (per seat of accommodation)
15
5
Government and Semi-public business
45
6
Mercantile (Commercial):
(a) Restaurants (per seat)
70
(b) Other business buildings
45
7
Industrial:
(a) Factories where bathrooms are to be provided
45
(b) Factories where no bath-rooms are required to be provided
30
8
Storage (including warehousing)
30
9
Hazardous
30
10
Intermediate / Stations (excluding mail and express stops)
45 (25)*
11
Junction Stations
70 (45)*
12
Terminal / Stations
45
13
International and domestic Airports
70
(i) * The value in parenthesis is for stations where bathing facilities are not provided.
(ii) The number of persons for Sr. No. (10) to (13) shall be determined by the average number of passengers handled by the station daily. Due consideration may be given to the staff and workers likely to use the facilities
Table 22Flushing Storage Capacities
Sr. No.
Classification of building
Storage capacity
(1)
(2)
(3)
1
Tenements having common convenience
900 liters per W.C. seat
2
Residential premises other than tenements having common convenience
270 liters for one W.C. seat and 180 liters for each additional seat in the same flat
3
Factories and Workshops
900 liters per W.C. seat and 180 liters per urinal seat
4
Cinemas, public assembly halls, etc.
900 liters per W.C. seat and 350 liters per urinal seat
(可..-843
HER T, - , T , 3 3-, R0/ R-, T 30
Table 23Domestic Storage Capacities
Sr. No.
No. of Floors
Storage Capacity
Remarks
(1)
(2)
(3)
(4)
For premises occupied as tenements with common conveniences
1
Floor (Ground)
NIL
Provided no down take fittings are installed
2
Floors 1, 2, 3, 4, 5 and upper floors
500* liters per tenement
For premises occupied as Flats or blocks
1
Floor (Ground)
NIL
Provided no down take fittings are installed
2
Floors 1, 2, 3, 4, 5 and upper floors
500* liters
Subject to provisions of water supply and drainage rules.
NOTE 1: If the premises are situated at a place higher than the road level in the front of the premises, storage at ground level shall be provided on the same line as on floor 1.
NOTE 2: The above storage may be permitted to be installed provided that the total domestic storage calculated on the above basis is not less than the storage calculation on the number of down take fittings according to the scales given below:
Down take taps - 70 liters each
Bathtubs - 200 liters each
31.0 Drainage and Sanitation Requirements
31.2For Residences
(a) Dwelling with individual convenience shall have at least the following fitments:
i) One bathroom provided with a tap and a floor trap;
ii) One water-closet with flushing apparatus with an ablution tap; and
iii) One tap with a floor trap or a sink in kitchen or washing place.
(b) Dwelling without individual conveniences shall have the following fitments:
i) One water tap with floor trap in each tenement;
ii) One water closet with flushing apparatus and one ablution tap, bath for every two tenements; and
iii) One bath with water tap and floor trap for every two tenements.
R T, , T , 3 3-, 2/ -, 3
31.1General
There should be at least one water tap and arrangement for drainage in the vicinity of each water closet or group of water closets in all the buildings.
(a) Each family dwelling unit on premises (abutting on a sewer or with a private sewage disposal system) shall have, at least, one water closet and one kitchen type sink. A bath or shower shall also be installed to meet the basic requirement of sanitation and personal hygiene.
(b) All other structures for human occupancy or use on premises, abutting on a sewer or with a private sewage disposal system, shall have adequate sanitary facilities, but in no case less than one water-closet and one other fixture for cleaning purposes.
32.0Signs and Outdoor Display Structures
32.1 In addition to Appendix IV of the ’Principal Regulations’ (except item IX that contains the provision for deposit and fees), the display of advertising signs on buildings and land shall be in accordance with Part 10, Section 2 "Signs and outdoor display structures" of National Building Code of India as amended from time to time.
HER T, - , T , 3 3-, R0/ R-, T 30
32.2. Prohibition of advertising signs and outdoor display structure in certain cases: - No advertising sign or outdoor display structures shall be permitted on buildings of architectural, aesthetical, historical or heritage importance as may be decided by the Authority. In the case of Government buildings, advertising signs or outdoor display structures may be permitted only if they relate to the activities carried out in the building, or are for own purposes or related programmes.
32.3 ’Developer’ shall be free to decide, levy and recover suitable fees for advertisements and hoardings and any deposit therefor.
महाराष्ट्र शासन राजपत्र, भाग एक-कोकण विभागीय पुरवणी, गुरुवार ते बृधवार, ऑंगस्ट १३-१९, २०१५/शावण २२-२८, जके १९३७
31.3For Buildings Other than Residences
31.3.1 The requirements for fitments for drainage and sanitation in the case of buildings other than residences shall be in accordance with Table to Table . In addition, the following shall be taken into consideration:
a) The figures shown are based upon one (1) fixture being the minimum required for the number of persons indicated or part thereof.
b) Building categories not included in the tables shall be considered separately by the Authority.
c) Drinking fountains shall not be installed in the toilets.
d) Where there is a danger of exposure to skin contamination with poisonous, infectious or irritating material, washbasin with eye wash jet and an emergency shower located in an area accessible at all times by a passage / right of way, suitable for access to a wheel chair, shall be provided.
e) When applying the provision of these tables for providing the number of fixtures, consideration shall be given to the accessibility of the fixtures. Using purely numerical basis may not result in an installation suited to the needs of a specific building. For example, schools should be provided with toilet facilities on each floor. Similarly toilet facilities shall be provided for temporary workmen employed in any establishment according to the needs; and in any case one W.C. and one washbasin shall be provided.
f) All buildings used for human habitation for dwelling, work, occupation, medical care or any purpose detailed in the various tables, abutting a public sewer or a private sewage disposal system, shall be provided with minimum sanitary facilities as per the schedule in the tables. In case the disposal facilities are not available, they shall be provided as a part of the building design for ensuring high standards of sanitary conditions.
g) Workplaces where crèches are provided, they shall be provided with one W.C. for 10 persons or part thereof, one washbasin for 15 persons or part thereof, for preparing food / milk preparations, one kitchen sink with floor trap. The sink provided shall be with a drinking water tap.
h) In all types of buildings, individual toilets and pantry should be provided for executives and for meeting / seminar / conference rooms, etc. as per the user requirement.
j) Where food is consumed indoors, water stations may be provided in place of drinking water fountains.
28C
HER T, - , T , 3 3-, R0/ R-, T 30
Table 24Office Buildings
Sr. No.
Fixtures
Public Toilets
Staff Toilets
Male
Female
Male
Female
1
2
3
4
5
6
i)
Executive Rooms and Conference Halls in Office Buildings Toilet suite comprising one W.C., one washbasin (with optional shower stall at user's option if building is used round the clock) Pantry optional as per user requirement
Unit could be common for Male / Female or separate depending on the number of users of each facility
For individual officer rooms
ii)
Main Office Toilets for Staff and Visitors
a) Water-closet
1 per 25
1 per 15
1 per 25
1 per 15
b) Ablution tap with each water-closet
1 in each water-closet
c) Urinals Add @ 3% for Add @ 2.5 %
Nil up to 6 1 for 7 to 20 2 for 21 to 45 3 for 46 to 70 4 for 71 to 100 101 to 200 Over 200
-
Nil up to 6
-
d) Washbasins
1 per 25
1 per 25
1 per 25
1 per 25
e) Drinking water fountain
1 per 100
1 per 100
1 per 100
1 per 100
f) Cleaner's sink
1 per floor
Table 25Factories
Sr. No.
Fixtures
Offices / Visitors
Workers
Male
Female
Male
Female
1
2
3
4
5
6
i)
Water-closets (Workers & Staff)
1 for up to 25 2 for 16 to 35 3 for 36 to 65 4 for 66 to 100
1 for up to 15 2 for 16 to 25 3 for 26 to 40 4 for 41 to 57 5 for 58 to77 6 for 78 to 100
1 for up to 15 2 for 16 to 35 3 for 36 to 65 4 for 66 to 100
1 for up to 12 2 for 13 to 25 3 for 26 to 40 4 for 41 to 57 5 for 58 to 77 6 for 78 to 100
For persons 101 to 200 add
3 %
5 %
3 %
5 %
For persons over 200 add
2.5 %
4 %
2.5 %
4 %
ii)
Ablution tap
1 in each water-closet
1 in each water-closet
1 in each water-closet
1 in each water-closet
iii)
Urinals For persons 101 to 200 add For persons over 200 add
Nil up to 6 1 for 7 to 20 2 for 21 to 45 3 for 46 to 70 4 for 71 to 1003 %2.5 %
-
Nil up to 6 1 for 7 to 20 2 for 21 to 45 3 for 46 to 70 4 for 71 to 1003 %2.5 %
-
iv)
Washbasins Washbasins in rows or troughs and taps spaced 750 mm c/c
1 per 25 or part thereof
1 per 25 or part thereof
1 per 25 or part thereof
1 per 25 or part thereof
R T, , T , 3 3-, 2/ -, 3
Sr. No.
Fixtures
Offices / Visitors
Workers
Male
Female
Male
Female
1
2
3
4
5
6
v)
Drinking water fountain
1 per every 100 or part thereof with minimum one on each floor
1 per every 100 or part thereof with minimum one on each floor
vi)
Cleaner's sink
1 on each floor
1 on each floor
1 on each floor
1on each floor
vii)
Showers /Bathing rooms
As per trade requirements
viii)
Emergency shower and eye wash fountain
-
-
1 per every shop floor per 500 persons
NOTE – For factories requiring workers to be engaged in dirty and dangerous operations or requiring them to being extremely clean and sanitized conditions additional and separate (if required so) toilet facilities and if required by applicable Industrial and Safety Laws and the Factories Act must be provided in consultation with the user.
Table 26Cinema, Multiplex Cinema, Concerts and Convention Halls, Theatres
Sr. No.
Fixtures
Public
Staff
Male
Female
Male
Female
1
2
3
4
5
6
i
Water-closets
1 per 100 up to 400 Over 400, add 1 per 250 or part thereof
3 per 100 up to 200 Over 200, add 2 per 100 or part thereof
1 for up to 15
1 for up to 12
ii
Ablution tap
1 in each water-closet
iii
Urinals
1 per 25 or part thereof
-
Nil up to 6 1 for 7 to 20 2 for 21 to 45
-
iv
Washbasins
1per 200 or part thereof
1 for up to 15 2 for 16 to 35
1 for up to 12 2 for 13 to 25
v
Drinking water fountain
1 per 100 persons or part thereof
vi
Cleaner's sink
1 per floor
vii
Showers/ Bathing rooms
As per trade requirements
NOTES – (1) Some WC’s may be European style if desired.
(2) Male population may be assumed as two-third and female population as one-third.
HER T, - , T , 3 3-, R0/ R-, T 30
Table 27Art Galleries, Libraries and Museums
Sr. No.
Fixtures
Public
Staff
Male
Female
Male
Female
1
2
3
4
5
6
i)
Water-closets
1 per 200 up to400Over 400 add at 1 per 250 or part thereof
1 per 100 up to200Over 200 add at 1 per 150 or part thereof
1 for up to 15 2 for 16 to 35
1 for up to 12 2 for 13 to 25
ii)
Ablution tap
One in each W.C.
One in each W.C.
One in each W.C.
One in each W.C.
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals
iii)
Urinals
1 per 50
-
Nil up to 6 1 per 7 to 20 2 per 21 to 45
-
iv)
Wash basins
1 for every 200 or part thereof. For over 400, add 1 per 250 persons or part thereof
1 for every 200 or part thereof. For over 200, add 1 per 150 persons or part thereof
1 for up to 15 2 for 16 to 35
1 for up to 12 2 for 13 to 25
v)
Drinking water fountain
1 per 100 persons or part thereof
vi)
Cleaner's sink
1 per floor, Minimum
vii)
Showers/ Bathing rooms
As per trade requirements
NOTES: - 1) Some W.C.s may be European style if desired.
Male population may be assumed as two-third and female population as one-third.
Table 28Hospitals with Indoor Patient Wards
Sr. No.
Fixtures
Patient Toilets
Staff Toilets
Male
Female
Male
Female
1
2
3
4
5
6
i)
Toilet suite comprising one W.C., one wash basin and shower stall
Private room with up to 4 patients
For individual doctor's/officer's rooms
For General Wards, Hospital Staff and Visitors
ii)
Water-closets
1 per 8 beds or part thereof
1 per 8 beds or part thereof
1 for up to 15 2 for 16 to 35
1 for up to 12 2 for 13 to 25
iii)
Ablution tap
One in each W.C.
One in each W.C.
One in each W.C.
One in each W.C.
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals
iv)
Urinals
1 per 30 beds
-
Nil up to 6 1 for 7 to 20 2 for 21 to 45 2 for 21 to 45
-
R , , T , 3 3-, 2/ -, 3
v)
Wash basins
2 for every 30 beds or part thereof. Add 1 per additional 30 beds or part thereof
1 for up to 15 2 for 16 to 35
1 for up to 12 2 for 13 to 25
vi)
Drinking water fountain
1 per ward
1 per 100 persons or part thereof
vii)
Cleaner's sink
1 per ward
-
viii)
Bed pan sink
1 per ward
-
ix)
Kitchen sink
1 per ward
-
NOTES: - 1) Some W.C.s may be European style if desired.
Male population may be assumed as two-third and female population as one-third.
Provision for additional and special hospital fittings where required shall be made.
Table 29Hospitals - Outdoor Patient Department
Sr. No
Fixtures.
Patient Toilets
Staff Toilets
Male
Female
Male
Female
1
2
3
4
5
6
i)
Toilet suite comprising one WC and one washbasin (with optional shower stall if building used for 24 h)
For up to 4 patients
For individual doctor's/officer's rooms
ii)
Water-closets
1per 100 persons or part thereof
2 per 100 persons or part thereof
1 for up to 15 2 for 16 to 35
1 for up to 12 2 for 13 to 25
iii)
Ablution tap
One in each water-closet
One in each water-closet
One in each water-closet
One in each water-closet
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals
iv)
Urinals
1 per 50 persons or part thereof
-
Nil up to 6 1 per 7 to 20 2 per 21 to 45
-
v)
Wash basins
1per 100 persons or part thereof
2 per 100 persons or part thereof
1 for up to 15 2 for16 to 35
1 for up to 12 2 for13 to 25
vi)
Drinking water fountain
1 per 500 persons or part thereof
1 per 100 persons or part thereof
NOTES - 1) Some W.C.s may be European style if desired.
(2) Male population may be assumed as two-third and female population as one-third.
(3) Provision for additional and special hospital fittings where required shall be made.
(可...)---8
HER T, - , T , 3 3-, R0/ R-, T 30
Table 30Hospitals’ Administrative Buildings
Sr. No.
Fixtures
Staff Toilets
Male
Female
1
2
3
4
i)
Toilet suite comprising one W.C. and one wash basin (with optional shower stall if building used for 24 hours)
For individual doctor's/officer's rooms
ii)
Water-closets
1per 25 persons or part thereof
1per 15 persons or part thereof
iii)
Ablution tap
One in each W.C.
One in each W.C.
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of W.C.s and urinals
iv)
Urinals
Nil up to 6 1 per 7 to 20 2 per 21 to 45
-
v)
Wash basins
1per 25 persons or part thereof
1per 25 persons or part thereof
vi)
Drinking water fountain
1 per 100 persons or part thereof
vii)
Cleaner's sink
1 per floor, minimum
viii)
Kitchen sink
1 per floor, minimum
Table 31 : Hospitals’ Staff Quarters and Nurses Homes
NOTE - Some W.C.s may be European style if desired.
Sr. No.
Fixtures
Staff Quarters
Nurses Homes
Male
Female
Male
Female
1
2
3
4
5
6
i)
Water-closets
1 per 4 persons or part thereof
1per 4 persons or part thereof
1 per 4 persons or part thereof 2 for 16 to 35
1per 4 persons or part thereof 2 for 16 to 35
ii)
Ablution tap
One in each W.C.
One in each W.C.
One in each W.C.
One in each W.C.
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of W.C.s and urinals
iii)
Wash basins
1 per 8 persons or part thereof
1 per 8 persons or part thereof
iv)
Bath (shower)
1 per 4 persons or part thereof
1 per 4 persons or part thereof
v)
Drinking water fountain
1 per 100 persons or part thereof, minimum 1 per floor
1 per 100 persons or part thereof, minimum 1 per floor
vi)
Cleaner's sink
1 per floor
1 per floor
NOTES - 1) Some WC’s may be European style if desired.
For independent housing units fixtures shall be provided as for residences.
(.f)---3
R T, , T , 3 3-, 2/ -, 3
Table 32Hotels
Sr. No.
Fixtures
Public Rooms
Non-Residential Staff
Male
Female
Male
Female
1
2
3
4
5
6
i)
Toilet suite comprising one W.C., wash basin with shower or a bath tub
Individual guest rooms with attached toilets
-
Guest Rooms with Common Facilities
ii)
Water-closets
1 per 100 persons up to 400 Over 400 add 1 per 250 or part thereof
2 per 100 persons up to 200 Over 200 add 1 per 100 or part thereof
1 for up to 15 2 for 16 to 35 3 for 36 to 65 4 for 66 to 100
1 for up to 12 2 for 13 to 25 3 for 26 to 40 4 for 41 to 57 5 for 58 to 77 6 for 78 to 100
iii)
Ablution tap
One in each W.C.
One in each W.C.
One in each W.C.
One in each W.C.
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals
iv)
Urinals
1 per 50 persons or part thereof
-
Nil up to 6 1 for 7 to 20 2 for 21 to 45 3 for 46 to 70 4 for 71 to 100
-
v)
Wash basins
1 per W.C./Urinal
1 per W.C.
1 for up to 15 2 for 16 to 35 3 for 36 to 65 4 for 66 to 100
1 for up to 12 2 for 13 to 25 3 for 26 to 40 4 for 41 to 57
vi)
Bath (shower)
1 per 10 persons or part thereof
-
-
vii)
Cleaner's sink
1 per 30 rooms, minimum 1 per floor
viii)
Kitchen sink
1 per kitchen
NOTES– (1) Some W.C.s may be European style if desired.
(2) Male population may be assumed as two-third and female population as one-third.
(3) Provision for additional and special hospital fittings where required shall be made.
HER T, - , T , 3 3-, R0/ R-, T 30
Table 33Restaurants
Sr. No.
Fixtures
Public Rooms
Non-Residential Staff
Male
Female
Male
Female
1
2
3
4
5
6
i)
Water-closets
1 per 50 seats up to 200 Over 200 add at 1 per 100 or part thereof
2 per 50 seats up to 200 Over 200 add at 1 per 100 or part thereof
1 for up to 15 2 for 16 to 35 3 for 36 to 65 4 for 66 to 100
1 for up to 12 2 for 13 to 25 3 for 26 to 40 4 for 41 to 57 5 for 58 to 77 6 for 78 to 100
ii)
Ablution tap
One in each water-closet
One in each water-closet
One in each water-closet
One in each water-closet
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals.
iii)
Urinals
1 per 50 persons or part thereof
----
Nil up to 6 1 for 7 to 20 2 for 21 to 45 3 for 46 to 70 4 for 71 to 100
----
iv)
Washbasins
1 per WC
1 per WC
1 per WC
1 per WC
v)
Cleaner's sink
1 per restaurant
vi)
Kitchen sink /Dish washer
1 per kitchen
NOTES: 1) Some W.C.s may be European style if desired.
Provision for additional and special fittings where required shall be made.\
Male population may be assumed as two-third and female population as one-third.
7 (...)--3
R , , T , 3 3-, 2/ -, 3
Table 34Schools and Educational Institutions
Sr. No.
Fixtures
Nursery School
Non-Residential
Residential
Boys
Girls
Boys
Girls
1
2
3
4
5
6
7
i)
Water closets
1 for 15 pupils or part thereof
1 for 40 pupils or part thereof
1 per 25 pupils or part thereof
1 per 8 pupils or part thereof
1 per 6 pupils or part thereof
ii)
Ablution tap
One in each W.C.
One in each W.C.
One in each W.C.
One in each W.C.
One in each W.C.
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals.
iii)
Urinals
----
1 per 20 pupils or part thereof
----
1 per 25 pupils or part thereof
----
iv)
Wash basins
1 per 15 pupils or part thereof
1 per 60 pupils or part thereof
1 per 40 pupils or part thereof
1 per 8 pupils or part thereof
1 per 6 pupils or part thereof
v)
Bath/ Showers
1 per 40 pupils or part thereof
----
----
1 per 8 pupils or part thereof
1 per 6 pupils or part thereof
vi)
Drinking water fountain or taps
1 for 50 pupils or part thereof
1 for 50 pupils or part thereof
1 for 50 pupils or part thereof
1 for 50 pupils or part thereof
1 for 50 pupils or part thereof
vi)
Cleaner's Sink
1 per floor
NOTES: - 1) Some W.C.s may be European style if desired.
For teaching staff, the schedule of fixtures to be provided shall be the same as in case of office building.
Table 35Hostels
Sr. No.
Fixtures
Resident
Non-Resident
Visitor/ Common Rooms
Male
Female
Male
Female
Male
Female
1
2
3
4
5
6
7
8
i)
Water closet
1 per 8 or part thereof
1 per 6 or part thereof
1 for upto 15 2 for 16 to 35 3 for 36 to 65 4 for 66 to 100
1 for upto 12 2 for 13 to 25 3 for 26 to 40 4 for 41 to 57 5 for 58 to 77 6 for 78 to 100
1 per 100 up to 400 Over 400 add 1 per 250
1 per 200 up to 200 Over 200 add 1 per 100
ii)
Ablution tap
One in each W.C.
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals.
iii)
Urinals
1 per 25 or part thereof
----
Nil up to 6 1 for 7 to 20 2 for 21 to 45 3 for 46 to 70 4 for 71 to 100
----
1 per 50 or part thereof
----
HER T, - , T , 3 3-, R0/ R-, T 30
iv)
Wash basins
1 per 8 persons or part thereof
1 per 6 persons or part thereof
----
----
----
----
v)
Bath/Showers
1 per 8 persons or part thereof
1 per 6 persons or part thereof
----
----
----
----
vi)
Cleaner's Sink
1 per floor
NOTE: Some W.C.s may be European style if desired.
Table 36Fruit and Vegetable Markets
Sr. No.
Fixtures
Shop Owners
Common Toilets in Market Building
Public Toilet for Floating Population
Male
Female
Male
Female
Male
Female
1
2
3
4
5
6
7
8
i)
Water closets
1 per 8 persons or part thereof
1 for up to 15 2 for 16 to 35 3 for 36 to 65 4 for 66 to 100
1 for up to 12 2 for 13 to 25 3 for 26 to 40 4 for 41 to 57 5 for 58 to 77 6 for 78 to 100
1 per 50 (minimum 2)
1 per 50 (minimum 2)
ii)
Ablution tap
One in each water closet
1 water tap with draining arrangements shall be provided in receiving / sale area of each shop and for every 50 persons or part thereof in the vicinity of water-closets and urinals.
iii)
Urinals
----
----
Nil up to 6 1 for 7 to 20 2 for 21 to 45 3 for 46 to 70 4 for 71 to 100
----
1 per 50
----
iv)
Wash basins
1 per 8 persons or part thereof
1 for up to 15 2 for 16 to 35 3 for 36 to 65 4 for 66 to 100
1 for up to 12 2 for 13 to 25 3 for 26 to 40 4 for 41 to 57
----
----
v)
Bath / Showers
1 per 8 persons or part thereof
1 per 6 persons or part thereof
----
----
1 per 50 persons
1 per 50 persons
NOTES: (1) Toilet facilities for individual buildings in a market should be taken same as that for office buildings.
(2) Common toilets in the market buildings provide facilities for persons working in shops and their regular visitors.
(3) Special toilet facilities for a large floating population of out of town buyers/sellers, labour, drivers of vehicles for whom special toilet (public toilets).
R T, , T , 3 3-, 2/ -, 3
Table 37Airports and Railway Stations
Sr. No.
Fixtures
Junction Stations, Intermediate Stations and Bus Stations
Terminal Railway and Bus Stations
Domestic and International Airports
Male
Female
Male
Female
Male
Female
1
2
3
4
5
6
7
8
i)
Water closet
3 for up to1000Add 1 per additional 1000 or part thereof
4 for up to1000Add 1 per additional 1000 or part thereof
4 for up to1000Add 1 per additional 1000 or part thereof
5 for up to1000Add 1 per additional 1000 or part thereof
Minimum 2 For 200, 2 For 400, 9 For 600, 12 For 800, 16 For 1000, 18
Minimum 2 For 200, 2 For 400, 9 For 600, 12 For 800, 16 For 1000, 18
ii)
Ablution tap
One in each water closet
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals.
iii)
Urinals
4 for up to1000Add 1 per additional1000
----
6 for up to1000Add 1 per additional1000
----
1 per 40 or part thereof
----
iv)
Wash basins
1 per W.C. / Urinal
1 per W.C.
1 per W.C. / Urinal
1 per W.C.
1 per W.C. / Urinal
1 per W.C.
v)
Bath/Showers
2 per 1000
3 per 1000
4 per 1000
vi)
Drinking water fountain or taps (in common lobby for male/female)
2 per 1000 or part thereof
3 per 1000 or part thereof
4 per 1000 or part thereof
vii)
Cleaner's sink
1 per toilet compartment with 3 W.C.s
viii)
Toilet for Disabled
1 per 4000
NOTES: 1) Some WC’s may be European style if desired.
Male population may be assumed as three-fifth and female population as two-fifth.
Separate provision shall be made for staff and workers.