8.0 Procedure for Obtaining Development Permission / Commencement Certificate.
8.1 Application : - Every person who intends to carry out development and erect, re-erect or make alterations in any place in a building or demolish any building, shall make an application in writing to the Authority of his intention in the prescribed form (See Annexure A1 or A2) and such application shall be accompanied by the payment receipt of required scrutiny fee and any other fee/ charges prescribed by the Authority from time to time and the plans and statements in sufficient copies (See Clause No. 8.1.1), as required under Clauses 8.2 and 8.3. The plans may be ordinary prints on Ferro paper or any other type (prints only), one set of plans shall be retained in the office of the Authority for record after the issue of Commencement Certificate or its refusal. For the sake of scrutiny, the plans may be submitted in a digital format (soft copy) as may be specified by the Authority from time to time.
8.1.1 Copies of Plans and Statements : - A minimum of four copies of plans and statements shall be made available along with the application. In the case of building schemes, where the clearance is required from other agencies like Fire Services and other authorities, the number of copies of plans required shall be as decided by the Authority.
Information Accompanying Application : - The application shall be accompanied by the key (location) plan, site plan, sub-division plan, layout plan, building plan, services plans, specifications and certificate of supervision and ownership title as prescribed below:
8.2.1 Size of drawing sheets, colouring of plans and Dimensions.
8.2.1.1 The sizes of drawing sheets shall be any of those specified in Table 1 below.
| Sr. No. | Designation | Trimmed Size, mm |
|---|---|---|
| (1) | (2) | (3) |
| 1 | AO | 841 x 1189 |
| 2 | A1 | 594 x 841 |
| 3 | A2 | 420 x 594 |
| 4 | A3 | 297 x 420 |
| 5 | A4 | 210 x 297 |
Note : Submission of plans on sheets larger than A0 size is permissible.
(.f.y.)----3
RC ER T, T- a , T T , 3 3-, R0/ -, T 3
8.2.1.2 Colouring Notations for Plans : - The Plans shall be coloured as
specified in ‘Principal Regulations’. Prints of plans shall be on one side of paper.
Note : - For land development/ sub-division/ layout suitable colouring notations shall be used which shall be indexed.
8.2.1.3 Dimensions: All dimensions shall be indicated in metric units.
8.2.2 Ownership title and area : - Every application for development permission shall be accompanied by such of the following documents as may be relevant, for verifying the ownership and area etc. of the land: -
(a) 7/12 extract or property register card of a date not older than six months at the date of submission, attested copy of original registered deed for sale / lease / power of attorney etc. indicating ownership, whichever is applicable.
(b) A certified copy of the Measurement Plan of the property under development proposal.
(c) Statement of area of the holding by triangulation method from the qualified licensed technical person or architect with an affidavit from the owner about the area in the form prescribed by the Authority.
(d) Any other document prescribed by the Authority.
(e) Wherever a third party interest is created by way of agreement to sale or mortgage etc., the registered consent of such third party interests.
(f) A certified copy of approved sub-division / amalgamation / layout of land.
(g) In the case of leased land, the no-objection certificate of the Lessor.
(h) No-objection certificate from the ’ Developer ’.
8.2.3 Key Plan or Location Plan : - A key plan drawn to a scale of not less than 1:10,000 showing the boundary and location of the site with respect to neighbourhood landmarks.
8.2.4 Site Plan : - A site plan drawn to a scale not smaller than 1:500 and, where the plot is more than 10 hectares, to a scale not smaller than 1:2500, showing in addition the following details :
(a) Boundaries of the site along with disposition of contiguous land belonging to the owner and the position of site in relation to neighbouring streets ;
(b) The name of the street, if any, from which the building is proposed to derive access ;
R , , T , 3-, 2/ -,
(c) All existing buildings contained in the site with their names (where the buildings are given names) and their numbers;
(d) The position of the building and of other buildings, if any, which the applicant intends to erect, upon his land in relation to : -
(i) The boundaries of the site and, in a case where the site has been partitioned, the boundaries of the portions owned by others;
(ii) All adjacent streets, buildings (with number of storeys and height) and premises within a distance of 12 m. of the work site and of the contiguous land (if any) referred to in (a) above.
(e) The means of access from the street to the building and to all other buildings (if any) which the applicant intends to erect.
8.2.6.1 Building Plans for Multistoreyed and Special Buildings and Mixed
Occupancies : -
For the categories of buildings
(i) multistoreyed buildings which are more than 15m. height ;
(ii) special buildings for uses like educational, assembly, mercantile, institutional, industrial, storage and hazardous ;
(iii) mixed occupancies having area more than 500 sqm consisting of any one or more of the occupancies in (ii) above ;
in addition to the items (a) to (i) of Clause No. 8.2.6., following additional information shall be furnished and / or indicated in their Building Plans : -
R , , T , 3-, / -,
(a) access to fire appliances/ vehicles with details of vehicular turning circle and clear motorable access way around the building ;
(b) size (width) of main and alternate staircases along with balcony approach, corridor, ventilated lobby approach ;
(c) location and details of lift enclosures ;
(d) location and size of fire lift ;
(e) smoke stop lobby/door, where provided ;
(f) refuse chutes, refuse chambers, service ducts, etc .;
(g) vehicular parking spaces ;
(h) refuge area, if any ;
(i) details of building services :- air-conditioning system with position of fire dampers, mechanical ventilation system, electrical services, boilers, gas pipes etc .,
(j) details of exits including provision of ramps, etc. for hospitals and buildings requiring special fire protection measures,
(k) location of generator, transformer and switch gear room ;
(l) smoke exhauster system, if an y ;
(m) details of fire alarm system network ;
(n) location of centralized control, connecting all fire alarm systems, built in fire protection arrangements and public address system etc.
(o) location and dimensions of static water storage tank and pump room along with fire service inlets for mobile pump and water storage tank ;
(p) location and details of fixed fire protection installations such as sprinklers, wet risers, hose reels, drenchers, CO2 installation etc.;
(q) location and details of first aid, fire fighting equipments / installations.
(r) All provisions related to Active and Passive Fire Protection requirements adhering to Part 4 of National Building Code of India, 2005 i.e. Fire & Life Safety.
(s) Proof Checking of Structural Designs including Construction Process: The designs should be proof-checked by Proofing consultant appointed by the applicant. (The design consultant shall be required to submit all the design calculations and provide all necessary technical assistance in getting the designs proof checked). The Proofing Consultant shall also be responsible for proofing of maintenance of quality in construction process.
8.2.7. Service Plan : - Plans, elevations and sections of water supply, sewage disposal system and details of building services including rainwater harvesting, solar energy etc., as required by the Authority, shall be made available on a scale not less than 1:100 and for layouts at 1:1000.