19.1.1 Main Building : The height of plinth of a building or out house, including the floor surface of a stilt floor, shall not be less than 60 cm above both, the surrounding
R T, , T , 3 3-, R/ R-, 3
ground level and the road/roads abutting the site, and shall ensure adequate.drainage of the site. In areas subject to flooding, the height of the plinth shall be at least 60 cm. above the high flood level. In the case of a storage building, the plinth height shall be that required for loading purposes.
19.1.2 Interior Courtyards/ Inner Chowks: - Every interior Courtyard shall be raised at least 15 cm. above the surrounding ground level and shall be satisfactorily drained.
19.2.1 Size and Width : - The minimum size and width shall be as given in Table 8 hereunder.
| Sr. No. | Occupancy | Minimum size (sqm) | Minimum width (m) |
| (1) | (2) | (3) | (4) |
| 1 | Any habitable room | 9.5(other than those provided for below in this table and in Notes) | 2.4 |
| 2. | Single-roomed tenement | 12.5 | 2.4 |
| 3. | Rooms in a two-room tenement - (a) one of the rooms (b) other room | 9.57.5 | 2.42.4 |
| 4. | Rooms in a two-room tenement of a site and services project - (a)one of the rooms (b)other room | 9.35.6 | 2.42.3 |
| 5. | Single-bedded room in a hostel of a recognised educational institution | 7.5 | 2.4 |
| 6. | Shop | 6.0 | |
| 7. | Class room in an educational building | 38.0 or area at the rate of 0.8 sqm per student, whichever is more | 5.5 |
| 8. | Institutional building - (a) special room (b) general ward | 9.540.0 | 3.05.5 |
| 9. | Cinema hall, theatre, auditorium, assembly hall, etc. | In conformity with the Maharashtra Cinema Rules | |
Note : - (i) An additional bedroom for occupancy of a single person shall be of a size of 5.5 sqm with a minimum width of 1.8 m.
(ii) Other requirements - One full side of a habitable room must abut an exterior open space or an inner chowk as provided in Regulation 17.2.1.
ER , - , , 3 3-, R/ -, 3
19.2.2 Height : - The minimum and maximum height of a habitable room shall be as given in Table 9 below.
| Serial No. | Occupancy | Minimum height (m) | Maximum Height (m) |
| (1) | (2) | (3) | (4) |
| 1 | Flat Roof - | ||
| (a) Any habitable room | 2.75 | 4.2 | |
| (b) Habitable room in High Density Housing | 2.6 | 4.2 | |
| (c) Air-conditioned habitable room | 2.4 | 4.2 | |
| (d) Assembly halls, residential hotels of 3-star category and above, institutional, educational, industrial, hazardous or storage occupancies, department stores, entrance halls and lobbies to department stores and assembly halls | 3.6 | 4.2greater height may be permitted subject to written permission of the Chief Executive Officer, MIDC. | |
| 2 | Pitched Roof - | ||
| (a) Any habitable room | 2.75 average 2.1 at the lowest point | 4.2 average 3.2 at the lowest point | |
| (b) Habitable room in High Density Housing | 2.6 average 2.0 at the lowest point | 4.2 average 3.2 at the lowest point | |
Notes: (i) The minimum clear headroom under any beam shall be 2.4 m.
(ii) Room for ITE or any telematic equipment can have a height as required for effective functioning of that system.
(iii) In all occupancies, except those included in serial no. 1(d) in the Table 9 above, any height in excess of 4.2 m. shall be deemed to have consumed an additional F.S.I. of 50 per cent of the relevant floor area.
19.3.1 Size : The area of the kitchen shall not be less than 3.3 sq. m. with a minimum width of 1.5 m.
19.3.1.1 No provision for kitchen is necessary in a scheme of single-roomed tenements (item 2 in Table 8). However, an alcove (a cooking space having direct access from the main room without any inter-communicating door) of a size not less than 2.4 sqm with a minimum width of 1.2 m shall be provided.
ER T, T- a , T , 3 3-, RO/ -, T 3
19.3.2 Height : The room height of a kitchen measured from the surface of the floor to the lowest point in the ceiling (bottom of slab) shall not be less than 2.75 m or according to item 2 in Table 9.
19.3.3 Other Requirements : Every room to be used as a kitchen shall have -
(a) Means for washing of kitchen utensils, which shall lead directly or through a sink to grated and trapped connection to the waste pipe;
(b) Impermeable floor;
(c) A window of not less than 1.0 sq. m. area, opening directly on to an inner or outer chowk, but not into a ventilation shaft; and
(d) Refuse chutes, in the case of multi-storeyed residential buildings more than 24 m in height.