22.0 Fire Protection Requirements
Provisions of Regulation no. 40 of the ‘Principal Regulations’ shall apply.
23.0 SPECIAL REQUIREMENTS OF OTHER BUILDINGS :-
23.1 Educational buildings.
(a) Educational buildings shall not be permissible within 60 m from any assembly building and 90 m from any petrol pump.
(b) Area and Width of Classroom: - No classroom shall admeasure less than 38 sqm with a minimum dimension of 5.50 m.
(c) Height of Classroom: - This shall not be less than 3.60 m.
(d) Exit Requirements: - These shall conform to Regulation No. 21.0 Exit Requirements.
(e) Water Supply, Drainage and Sanitation: - These shall conform to requirements of Regulations Error! Reference source not found. and Error! Reference source not found. of these regulations.
(f) Parking spaces: - These shall conform to regulation no. 18.0 Parking, Loading and Unloading Spaces.
(g) Playground: - At least 40 per cent of plot area shall be kept open for playground.
23.2. Institutional Buildings (Hospitals, Maternity Homes, Health Centres and Sanatoria).
(a) Hospitals and Sanatoria shall be constructed on independent plot.
(b) Any Special ward in the hospital building shall not admeasure less than 9.0 sqm in area with no side less than 3 m.
(c) Area of the general wards shall not admeasure less than 40 sqm with no side less than 5.5 m.
(d) Refuse collection area shall have a minimum size of 7.50 sqm. This shall not be allowed in marginal open spaces. Modern methods of incineration of refuse may be adopted.
(e) Exit Requirements-This shall conform to regulation No. 21.0 Exit Requirements
(f) Water Supply, Drainage and Sanitation: - This shall conform to requirements of regulations no. Error! Reference source not found.and Error! Reference source not found. of these regulations.
R , , T , 3-, 2/ -,
(g) Parking Spaces: - This shall conform to Regulation No.18.0 Parking, Loading and Unloading Spaces.