10.1.4 No piece of land shall be used as site for the construction of building,
(a) If the land is within a prohibited distance (currently of seventy five meters) from the crest of the outer parapet of the Armament Research and Development Establishment (ARDE), Range Pashan, Pune;
(b) If the land is within a prohibited distance of approximately 457.2 m. (500 yards) from the crest of the outer parapet of the High Energy Materials Research Laboratory (HEMRL), Sutarwadi, Pune as shown on Development Plan;
10.2Thane Municipal Corporation Area.
($)10.2.1 Development along Ram Maruti Road and Gokhale Road.
Front set-backs for development on above roads shall be as below :-
In the case of plots fronting on Ram Maruti Road, only ground floor of the structure shall be set back by 3.05 m. from the road line and rest of the floors shall be set back at a distance of 4.5 m. (1) The front terrace so formed shall be allowed to be accessible.
ii) In case of any plot fronting on Gokhale Road, from the portion between Ashok Talkies and its junction with M.G. Road, the ground floor of the building shall be set back by 2.3 m. from the road line and the upper floors shall be set back at a distance of 4.5 m. subject to condition that the owner of the plot shall pave the front open space. (1) The front terrace so formed shall be allowed to be accessible.
10.2.2 Setbacks from Eastern Express Highway and Roads more than 52.5 m. in width.
No construction of building shall be undertaken within 7.5 m. from the boundary of the Eastern Express Highway and other roads having prescribed width more than 52.5 m.
186
10.2.3a) Development of Multi Storey Public Parking Lot (PPL) near Metro Stations.
For development of Multi-storied PPL on any plot abutting a road of minimum width of 18 m., additional FSI ( hereinafter referred to as ―Incentive FSI‖ ) as specified below on built up parking area, created and handed over to the Thane Municipal Corporation (TMC) free of cost with amenities required for parking area as prescribed by the Commissioner such PPL shall be allowed, on the land belonging to a private owner/Lease hold plots of Govt. and TMC with prior consent, which is not reserved for any public purpose, subject to the conditions contained herein below:
I. The minimum area of plot shall be 1000 Sq.m. in sector - 1, 2, 3 and 2000 Sq.m. in remaining sectors. The minimum number of Motor Vehicle public parking spaces provided shall not be less than 50. The location of parking spaces can be in 2 level basement, ground floor or upper 2 floors maximum, with access through ramp/lift or combination of both subject to clearance from CFO with special emphasis on fire hazard.
II. A Committee under the Chairmanship of Municipal Commissioner, TMC shall earmark/ select the plots for public parking, on the basis of their suitability. The Committee shall comprise the following or their representatives (i) Metropolitan Commissioner, MMRDA. (ii) Dy. Commissioner of Police (Traffic), (iii) Joint Director of Town Planning, Konkan Division (iv) Assistant Director of Town Planning, TMC (Member Secretary).
III. The incentive FSI given on this account will be over and above the base FSI permissible under any other provisions of UDCPR. This incentive FSI shall be allowed to be used on the same plot in conformity with UDCPR/ DP, within the overall cap/ limit of total maximum permissible FSI as given at (vii) below.
IV. The proposed development shall be subject to any other conditions prescribed by the Municipal Commissioner.
V. Concerned land owner/ developer/ society/ company shall not be allowed to operate the public parking lot.
VI. Area covered under parking shall not be counted towards FSI consumption.
VII. The incentive FSI permissible under this Regulation against BUA of the PPL shall be 50% of the BUA of the PPL, such that the total permissible FSI including the incentive FSI under this Regulation does not exceed the limit as per Regulation 6.3.
VIII. The maximum cap on BUA per parking shall be 50 Sq.m. for LMVs, 65 Sq.m. for LCVs and 120 Sq.m. for HMVs/Buses. Incentive FSI shall be calculated as per BUA of the PPL, based on these norms or the actual BUA of the PPL, whichever is less.
IX. The developer of the PPL shall pay ‗premium‘, worked out as per the following formula:-
Premium = 60% of [ Value of the additional BUA corresponding to the incentive FSI admissible under this Regulation, as per A.S.R. – (Cost of construction of PPL + cost of any extra amenities/facilities provided + cost of construction of BUA corresponding to the incentive F.S.I. admissible under this Regulation) ]
For the purpose of calculating premium as above, the cost of construction of PPL including amenities/ facilities and the cost of construction of BUA corresponding to the Incentive FSI admissible under this Regulation shall be 75% and 125% respectively of the rate of RCC construction as per ASR.
X. The Premium shall be paid before the issuance of building permission for the incentive FSI admissible under this Regulation.
Upon Payment of 100% premium as aforesaid, building permission shall be issued in respect of 50% of incentive FSI. In no case, Incentive FSI be released without handing over of the PPL, complete in all respects, to TMC.
The year in which premium is paid before the issuance of building permission for the PPL shall be taken as the year for determination of construction cost as well as ASR for calculation of the premium. Out of the total premium payable, 50% shall be paid to the GoM and the remaining 50% to TMC.
Provision of this Regulation may also be applicable to lease hold plots of Govt. and TMC with prior approval from Government/ Municipal Corporation.
XI. The land owner/ developer/ Society/ company shall hand over PPL with separate entrance and exit for the dedicated use of TMC by way of registered conveyance deed. Such PPL will not be part of proposed society/ apartment/ owners association.
XII. The PPL shall not be permissible in combination with other regulations.
XIII. Public Parking shall be developed in independent building as far as possible, but it may permissible in composite buildings subject to compliance of these regulations.
XIV. The Commissioner may hand over such PPL to any agency to transparent bidding procedures for its operations and maintenance upon such terms and conditions as deem fit and proper. However in any condition such PPL shall not be allotted to concerned land owners/ housing society/ association of apartment owners of occupiers in the plot of PPL.
XV. No public parking lots shall generally be more than 500 vehicles. However in exceptional cases Commissioner may permit PPL for 1000 vehicles for the reasons to be recorded in writing.
XVI. PPL connectivity to nearest station of Local/ Mono/ Metro/ BRTS etc. may also be insisted if propose PPL is within 250 m. by skywalk and underground connectivity within 100 m. These area shall also be counted for giving incentive FSI and shall not be included for calculating limits of vehicles.
XVII. For every sectors Commissioner shall endeavour to evaluate total need of PPL and shall cause it to be declared in local newspaper within three months of promulgation of these regulation for every 5 years. Total PPL sanctioned in any sector shall not increase beyond that for next 5 years. PPL shall be allowed only after studying traffic impact analysis of area with the periphery of 250 m. of PPL.
10.2.4Development around Hazardous Industries (Chemical Zone Areas).
a) Green Belt -
i) There shall be green belt of 100 m. around the boundary of the Hazardous Chemical Industries as shown on plan attached with the report of authority.
ii) The creation of the green belt, its development and maintenance as per report of authority will be the responsibility of Municipal Corporation.
iii) The cost of acquisition of land for the green belt, around the Hazardous Chemical Industries will be borne by the Industry / Industry Association. The private land owner will be given Transfer of Development Rights based on FSI for the present land usage. The cost of acquisition to be borne by industry will be exclusive of the value of TDR.
The existing authorised structures should be tolerated. However, only repairs to such existing structures should be allowed in future and no reconstruction or new construction should be allowed in the Green Belt.
v) Unauthorised structures should be removed or relocated by the Thane Municipal Corporation as per the existing Public Policy.
b) Creation of Low Density Zone
i) Beyond the Green Belt, another belt of 150 m. should be created as "Low Density Zone" as shown on plan, attached with the report of the Authority.
ii) The FSI in the Low Density Zone shall be 0.5 and only Ground plus two storey structures should be allowed.
iii) The existing buildings if already authorised with the higher FSI and plan of the proposed building already approved by the Thane Municipal Corporation and Commencement Certificate have been given to such structure should be allowed to continue, be completed and occupied by the issuing Occupation Certificate. Where the plans have been approved by the Thane Municipal Corporation but commencement certificates have not been issued, they should be reviewed and the permission should be revised in accordance with the Low Density Zone Regulation, now be prescribed.
iv) The development proposals in Low Density Zone shall be scrutinised and permission shall be granted as per these UDCPR.
c) Development between 250 and 1000 Meters.
The Development proposals beyond the area of 250 m. shall be scrutinised and permissions shall be granted as per these UDCPR.
Other Stipulations -
i) The original land under Chemical Industry, which has been certified by the Director of Industries/ Director of Industrial Safety and Health/ Competent Authority as permanently closed or having shifted elsewhere shall be allowed to be developed as per the relevant provisions in the prevailing Development Control Regulations.
Upon certification by the Director of Industries/ Director of Industrial Safety and Health/ Competent Authority that the Chemical Industry has been permanently closed or has shifted elsewhere, the 100 m. Green belt and the further 150 m. low density belt around the plot boundary of such Chemical Industry shall suo-moto cease to exist.
10.2.5Development around Air Force Stations.
i) As per Government of India, MoD SRO No. 4, dated 13 January, 2010 which was published in Part-II Section 4 of Gazette Notification dated 23 January, 2010. Air Force Station Thane falls within the 100 m. restriction zone. As per notification, no construction should be permitted within the restricted zone of 100 m. from the outer parapet of the Air Force boundary. Similarly, live hedges, tree/rows or clumps of trees or orchards shall not be maintained, planted, added to or altered within the 100 m. restricted zone. The restriction is equally applicable for construction of underground structure, wherein no digging and/ or change in the level of ground is permitted within the notified zone.
ii) Beyond the notified zone of 100 m., no restriction is required to be imposed as per the Works of Defence Act 1903 and no NOC from Air Force Station, Thane is necessary. (1) (--)
(2)10.2.6 Development around Defence Establishment.
Following restrictions are imposed in and around the land in the vicinity of the said unit as per the plan enclosed with Notification No.TPS-1203/1254/C.R.193/05/UD-12, Dt.30/12/2006.
Village : Kolshet/Kavesar/Waghbil (within the limit of Thane Corporation)
Circle / Taluka : Thane, District : Thane, State: Maharashtra
Height Restrictions:-
(a) The height restrictions to any of the future constructions on North, North-West, West and South-West sides will be as follows:-
Sr. No.
Height Limiting zones from unit boundary (Zones indicated by colours)
(2)(b) The height restrictions to any of the future constructions on North East, East and South-East sides will be as follows :-
Sr. No.
Height Limiting zones from unit boundary (Zones indicated by colours)
Permissible height in meters
Remarks.
A
Red
Nil
Unit Area
B
Brown
Nil
Buffer Zone (No Dev. Zone)
C
Orange
15
--
D
Pink
20
--
E
Yellow
35
--
F
Violet
40
--
G
Sky Blue
45
--
Other Restrictions :- In addition to the above restrictions, following general restrictions are also enforced :-
a) No high tension power line up to 22 KV is to be setup within 1500 meters from unit boundary.
b) Open wires, overhead lines, including telephone cables are to be outside 500 meters from unit boundary. However, UG cables. (below 5 meters) are permissible.
c) No rail line with electric traction is permitted within two kilometers from the unit.
d) Area within one kilometer radius from unit boundary is to be clear of all metallic structures including bridges.
e) Ground water level is to remain constant. No efforts are to be made to change the electrical conductivity of the designated zone.
f) No industry/equipment, which generates any kind of RG noise, are permitted to operate within 1 km. Radius from unit boundary.
10.2.7Regulations for G-1 Zone (Yeur village Section-VII only)
Following uses shall be permitted in G-1 Zone.
The residential Building on the lands which are actually under cultivation and the holiday homes for weekend stay and the Rest Houses subject to following conditions :-
The plot to be permitted for such development shall be not less than 4000 Sq.m. with the maximum FSI of 0.025.
Each building to be not more than ground plus one storey with height not exceeding 9.75 m. including the height of stilt portion if any, subject to maximum built up area 100 Sq.m. excluding stilt.
To permit Club House, open play Grounds and other recreational purposes as normally permissible under green zone with permissible FSI as per these Regulations.
To insist plantation at the rate of two fast growing trees per 100 Sq.m. of land under development.
10.2.8 Regulations for G-3 Zone for Forest Area.
No development of any sort shall be allowed in this zone except the project of the Forest Department. In case of pockets of private lands in G-3 zone, development shall be permitted as per the provisions of Green Zone / as per the provisions of G-1/G-2 Zone subject to concurrence of Forest Department.
10.2.9 (1) For the sake of Regulations No.1.3.74, No. 1.3.93 (xiv)(i) and No.6.2.3(b) High Rise Building / Special Building means any multi-storied Residential Building, which is under redevelopment, and which is more than 25 m. in height above average surrounding ground level.
10.2.10(2) Redevelopment of Old Dilapidated / Dangerous Buildings
Reconstruction / Redevelopment in whole or in part of any building which has ceased to exist in consequence of accidental fire / natural collapse or demolition for the reasons of the same having been declared dangerous or dilapidated or unsafe by or under a lawful order of the Authority or building having age of more than 30 years, shall be allowed subject to following conditions.
Redevelopment of multi-dwelling buildings of society/ Co-Operative Housing Societies / Apartments -
i) The FSI allowed for redevelopment of such building shall be FSI permissible under Regulation No.6.1 or 6.3 including FSI on payment of premium and maximum permissible TDR loading as per Table 6-A or 6-G, or the FSI consumed by the existing authorized building including TDR, premium FSI etc., whichever is more. (Such TDR, Premium FSI etc. utilised in existing building shall be treated as a basic FSI for redevelopment.) In addition to this, incentive FSI to the extent of 50% of the existing authorised built up area or 15 Sq.m. per tenement, whichever is more, shall be allowed. Provided that in cases where carpet area occupied by residential tenement in the existing building is less than the carpet area of 27.87 Sq.m. then such tenement shall be entitled for minimum carpet area of 27.87 Sq.m. and difference of these areas shall be allowed as additional FSI without any premium. In case of non-residential occupier the area to be given in the reconstructed building shall be equivalent to the area occupied in the old building. Such incentive FSI shall not be applicable for redevelopment of existing bunglow.
ii) This regulation shall be applicable only when existing members of the societies are proposed to be re-accommodated.
iii) If tenanted building/s and building/s of co-operative housing society/non-tenanted building/s coexist on the plot under development, then proportionate land component as per existing authorized built up area of existing tenanted building on the plot shall be developed as per Regulation No.7.6.2. and remainder notional plot shall be developed as per this regulation.
191
iv) Notes below Regulation No.7.6 shall be applicable to this regulation.
(1) Inserted Vide Corrigendum / Addendum No.CR 79/2021, dt. 02nd December 2021.
(2) Inserted Vide Order No.CR 236/18 (Part 3), dt. 02nd December 2021.
10.2.11(1) Height of Building Permissible for Re-development Proposals / SRA Proposals
For all re-development proposals and slum-rehabilitation schemes in Municipal Corporation area, the building height upto 70.0 m. shall be permissible on roads having width between 9.0 to 12.0 m. subject to minimum front margin as per these regulations or minimum 6.0 m., whichever is less and subject to condition that such road shall be widened to 12.0 m. under the provisions of the Municipal Corporation Act, by prescribing line of street before granting occupation certificate to such buildings of re-development or slum-rehabilitation schemes. This shall be subject to Fire prevention, protection and life safety requirements and Fire NOC from Chief Fire Officer.
10.2.12(1) Podium
Podium for parking alongwith ramp may be permitted with side and rear marginal distance of 1.5 m. from plot boundary, subject to following conditions :-
a) Top of the Podium shall be accessible for Fire Engine by 7.5 m. Ramp with gradient 1:10.
b) Structural Stability Certificate regarding such Podium and Ramp shall be submitted with respect to stand Fire Engine over it & sustain load of Fire Engine.
c) Minimum 6 m. marginal distances with required turning circle over the Podium shall be provided for manoeuvring of Fire Engine.
Provided that, if the podium is not accessible for Fire Engine then 6.0 m. marginal open space shall be provided all around the building excluding front margin. Turning circle shall not be less than 9.0 m. The refuge area in such cases shall be facing front road and shall be connected to Fire Tower as per Clause 2.24 of Part 4 of NBC 2016.
d) Provisions mentioned in Regulation No.9.13 shall be applicable except (ii).
10.2.13
(1) Front Marginal Distances / Set-back / Road side margin/s in congested area minimum front marginal distance for buildings under re-development proposal shall be 1.5 m. for roads having width 6 m. or more.
10.2.14
(1) Off street parking requirement - For Redevelopment Projects in Thane Municipal Corporation area, multiplying factor for off street parking requirement as per regulation no.8.2.2 shall be 0.8.
10.2.15
(a) For Redevelopment of smaller plots having area upto 1500 Sq.m. with multistoried building upto 24.0 m. height plus height of parking upto 6.0 m., side / rear margin of 6.0 m. shall be relaxed upto 3.0 m. subject to Fire NOC, in case of bonafide hardship and such building shall not be considered as special building.
(b) Other provisions mentioned in Regulation No.6.2.3 shall be applicable.
(1) Inserted Vide Corrigendum / Addendum No.CR 79/2021, dt. 02nd December 2021
10.3
NAGPUR MUNICIPAL CORPORATION The following regulations shall be applicable
10.3.1
Buildings in Commercial Zone : (a) In non-congested area : FSI for buildings outside congested area in commercial zone - the basic FSI permissible shall be 2.00 for commercial cum residential use or purely residential use and 2.50 for purely commercial use. (b) In congested area : The permissible FSI for commercial use shall be 1.50 for the plots fronting on the road having width less than 9 m. and 2.00 for the plots fronting on the road having width 9 m. or more.
10.3.2
Buildings in Industrial Zone a) In congested area, the permissible FSI for industrial use shall be 1.00. b) In non-congested area, the permissible FSI for industrial use shall be 2.5.
10.3.3
I to R provisions - Allowing Residential/ Commercial uses in Industrial Zone. The Regulation No. 4.8.1 in these regulations shall be applicable to Nagpur Municipal Corporation area with following modifications. i) Any open land or lands of closed Industrial unit/ units in the Industrial Zone (Excluding the leased out plots by NIT/ NMC) may be permitted to be utilized for all the users permissible in the Residential zone with permissible FSI in Residential Zone, subject to payment of premium to be paid equal to 15% of the rate of developed land as given in the Annual Statement of Rates published by IGR every year. However, for the Industrial Plots leased out by Planning Authority, (NIT / NMC) while granting I to R permission on these plots, FSI of 2.5 for purely commercial use and 2.00 for Mix use shall be permissible subject to payment of premium at the rate of 15% for Residential and 20% for Commercial use. Premium charges shall be as per rate of developed lands as given in the Annual Statement of Rates published by IGR every year. ii) Provisions of Regulation No. 4.8.1 (b) (iv) shall not be applicable where the Industrial layout has already been approved, and where in amenity space has already been provided in the approved layout.
10.3.4
For Plots admeasuring 1000 Sq.m. and above (including amalgamated plots) in Residential Zone, basic FSI shall be 1.25, in congested and non-congested area, irrespective of road width. In cases covered in Regulation No. 10.3.1 and 10.3.4 maximum building potential on plot including in-situ FSI shall remain the same, as mentioned in Table No. 6 A and 6 G. However, the owner shall be at liberty to avail, the difference of potential if any, out of column 4 or/ and 5.
10.4
NAGPUR METROPOLITAN REGION DEVELOPMENT AUTHORITY
10.4.1
(#) Development along Ring Road: 250 m. Residential Zone/ Residential Belt proposed along the 60 m. wide Outer Ring Road as a corridor development is sanctioned, subject to payment of premium. The development in this 250 m. corridor is permitted on payment of premium as decided by the Government on the total area of land under development or building permission. Such premium shall be deposited with the concerned Authority. (#)Clarification issued vide Order No. CR 236/18 (Part 2), dt., 23<sup>rd</sup>December, 2021
10.4.2Special Regulations for the Improvement Schemes :
The improvement schemes by Public participation which are sanctioned by the Government under the provisions of the Nagpur Improvement Act 1936 and which comes under the jurisdiction of the NMA area shall be valid and continue to be valid for the said purpose under the said Act. The Special Development Control Regulations for these schemes shall be as mentioned below :-
Any changes/ Modifications/ Amendments in the details layout or in the master plan shall be carried out by the Metropolitan Commissioner at his own level. However the Public Amenity/ Public Utility Areas and their percentage as per original sanction shall not be changed while making Modifications/ Amendments in the Schemes.
i) Improvement Scheme - The scheme is prepared under the NIT Act 1936 for the notified area and is duly approved by the State Government and which is now included in NMRDA area.
ii) Original Plot - A plot consisting of nearby khasras calculated as a single record in a village which is under same ownership and has the same tenure status as defined in the respective 7 / 12 documents of the khasras.
iii) Final Plot - The plot which is reconstituted or reshaped from the Original Plot within a draft/ sanctioned Improvement Scheme in a manner appropriate for development and given access from the public right of way. The Final Plots is reconstituted as per the relevant regulations/ Act as Final plots for Authorities share and owners share.
iv) Owner - An owner is a person who has legal title for land or building. The definition also includes :-
a) An agent or trustee who receives the rent on behalf of the owner;
b) An agent or trustee who receives the rent of a or is entrusted with or is concerned with any building devoted to religious or charitable purposes;
c) A receiver, executor or administrator or a manager appointed by any court of competent jurisdiction to have the charge of, or to exercise the rights of the owner; and
d) A mortgage in possession.
v) Permissible FSI For Final Plot –
i) The Metropolitan Commissioner may allow the owner to develop the final plot in possession of the owner subject to handing over to the Planning Authorities share as independent plot free of cost as per norms prescribed by Metropolitan Commissioner.
ii) The owner shall thereafter be entitled to develop his final plot for the uses permissible in adjoining zone as per the this DCPR with full permissible FSI of the entire Plot alongwith Additional FSI/TDR potential permissible for his Final plot share as per Chapter No. 6 of this DCPR .
iii) The Metropolitan Commissioner shall develop the Final Plot in his possession (Authorities Share) for the purpose for which the scheme is sanctioned. This plot shall be entitled to be developed as per potential permissible for Authorities Final plot share as per Chapter No. 6 of this UDCPR.
10.4.4
vi) Net Plot area for Computation of FSI - For the purpose of computing FSI/Built - up area, the net area of the plot shall be as defined in these regulations.
vii) Special Regulations For Inclusive Housing - The provision regarding inclusive housing in development proposal shall be not made applicable in Improvement scheme if the Final Plot in the possession of Authority is to be designed and develop for the purpose of any affordable housing scheme.
viii) Height of Building - The maximum height of building for all users shall be as per Chapter No. 6 of this UDCPR.
195
ix) Amenities Space - If the Amenity space has already provided in the scheme at the time of approval of scheme/ layout, in such cases the amenity space as required under this UDCPR shall not be insisted.
x) Land Use Permissible - All land uses mentioned in this UDCPR shall be permissible in the Improvement Schemes.
xi) Development Charges - The Development charges shall be recovered as mentioned in these regulations.
xii) Power to Authority - For the smooth implementation of the schemes, the Metropolitan Commissioner with the Approval of the Authority, makes / amends the rule in consistent to the relevant Act and Regulations assigned to it with prior approval of by the Government.
xiii) UDCPR - All regulations of UDCPR shall apply except above special regulations.
(#) 10.4.3 The following regulation shall be applicable only for the reference of Regulation No. 25.6 (xxxx) mentioned in the notification of sanctioning the Development Plan of Nagpur Metropolitan Region Development Authority.
In Agriculture zone, Residential use shall be allowed subject to following conditions.
a) Minimum area of land shall be 15.0 hect.
b) Land shall front on minimum 12 m. wide existing road.
c) Permissible FSI/ TDR shall be as that of Residential zone.
d) The offsite infrastructure like road, water supply, sewerage treatment plant having zero discharge shall be developed by land owner at his own cost, unless this infrastructure is provided by Authority.
e) 10% of the entire holding area shall be handed over to the Authority free of cost, without any FSI/ TDR and free of all encumbrances for sale by Authority for residential, commercial or industrial use depending upon the nature of development. This 10% area shall be over and above recreational open space and amenity space to be provided as per regulation. This 10% area shall front on minimum 12 m. wide road.
f) Premium on gross area at the rate of 5% of land rate in Annual Statement of Rates of the said land without considering the guidelines therein shall be paid to the Authority.
(1)The following regulation shall be applicable only for the reference of Regulation No. 25.6 (xxxxiii) mentioned in the notification of sanctioning the Development Plan of Nagpur Metropolitan Region Development Authority.
(#) Clarification issued vide letter No. CR 67/2022, dt. 6th September, 2022.
(1) Development permission around the periphery of Gaothan boundary -
Development permission around the periphery of Gaothan boundary shall be allowed as per the Regulation mentioned as below. This regulation shall be applicable only for the Rural centre and rural area (excluding nine urban centre area). Regulation for residential zone and other regulation shall be applicable.
The peripheral residential area shown along the Gaothan village is deleted and land thereunder included in Agriculture Zone. The development along the periphery of the Gaothan shall be allowed subject to following:
a) In the villages in Rural area / Rural Centre excluding the area under nine urban centres, Residential Development or development allowed in Residential Zone, may be permitted within the periphery of Gaothan boundary as per the criteria given below. The regulations in respect of residential zone specified in these UDCPR shall be applicable.
Sr. No.
Category of Village (Populations as per latest census)
Development allowed from Gaothan boundary
1
Up to 5000
750 M
2
Above 5000
1000 M
Such development may be permitted on payment of premium of the total area of land. Such premium shall be calculated considering 15 % rate of the said land as prescribed in the Annual Statement of Rates of the year granting such developments. Such premium shall be deposited in the concerned Authority.
Provided that, where more than 50% of area of the Survey Number/ Gat Number is covered within the above peripheral distance then the remaining whole of such Survey number/Gat number within one ownership shall be considered for development on payment of premium as above.
Provided further that, the premium charges shall be recovered at the time of tentative approval of the Development permission. Where tentative development permission is already granted before publication of this Development Plan and final approval is yet to be granted, then in such cases premium charges shall not be recovered at the time of final approval.
Provided further that, such payment of premium shall not be applicable in cases where development permission is already granted or layout is already approved by the authority before publication of Development Plan. Such premium shall also be not applicable for revision of such already approved permissions.
However, such development should not be permitted on lands which deserve preservation or protection from Environmental considerations viz. Hills and Hill tops and within the required Buffer Zone / prohibited Zone from river, lakes and reservoirs of minor and major project of water resource department.
10.5
NASHIK MUNICIPAL CORPORATION
10.5.1
Applicability of Regulations for some areas.i) The special Regulations framed by the Arbitrator for some final plots in TP Scheme No.1 (First Varied) shall remain in force.(2) (--)
(1) Inserted Vide Addendum No.CR 236/18 (Part-1), dt. 23<sup>th</sup> June, 2021.(2) Sr. No (ii) deleted vide Corrigendum / Addendum No. CR 121/21, dt. 02<sup>nd</sup> December, 2021.
10.5.2Development of Cycle Track Along River and Nallah
A cycle track shall be developed in green belt areas earmarked on Development Plan along the rivers. Also, cycle track proposal is shown on canal land in the Development Plan.
A distance of 6 m. from the edge of minor water course (nallah) is to be left as marginal distance for construction of any building. A 3 m. strip of land from the edge of such water course out of this 6 m. distance to be left shall be available for use as cycle track for general public. The compound wall shall be constructed excluding this distance of 3 m. strip for cycle track. The owner shall be entitled for FSI of this strip of land for cycle track, in-situ. This 3 m. wide strip shall be handed over to Municipal Corporation for which, owner shall be entitled for TDR or insitu FSI equivalent to 35% of the area of 3 m. wide strip. This regulation shall be applicable for development of land along Nallahs specified in Plan-A annexed with this UDCPR. Where development is already taken place and it is not possible to make provision for such 3 m. wide cycle track, then Municipal Commissioner shall be empowered to decide not to apply this regulation for particular stretch of nallah. In such cases, normal marginal distances under these regulations shall apply.
10.5.3Set back and marginal distances for 36 m. wide D.P. road passing through village Gangapur and Ambad.
Notwithstanding anything contained in Regulation No. 6.2.1, following set back and marginal distance shall be applicable for road mentioned below.
Description of the road
Min Plot Size in Sq.m.
Min width of plot in meters
Min set back from road side in meters
Min. side margins in meters
Min. rear margins in meters
Remarks
36 m. wide D.P. road from Gangapur S.No. 12 to AmbadS.No.199
300
12
3.00(for commercial use also)
2.00
2.00
Margins for buildings G+2 or stilt + 3 structure. Higher height permissible subject to marginal distances in Regulation No.6.2.3.
Vasai Virar City Municipal Corporation
Following regulations shall be applicable for the low intensity development areas in the Vasai Virar City Municipal Corporation.
The basic and total permissible FSI with DR/TDR on the plot shall be as under :-
Table No. 10 A
Sr. No.
Land use Zone
Base FSI
Additional FSI on payment of premium
Admissible TDR including Road widening FSI if any
Maximum permissibl e FSI
1
Low Density Residential Zone
0.3
0.2
--
0.5
(1)(--)
(1) Deleted vide Notificatio27n No.CR 121/21, dt. 27/10/2021.
10.7
MIRA BHAYANDAR MUNICIPAL CORPORATION -
10.7.1
Uses permissible in Agriculture Zone. The lands along 45m., 30 m. wide roads upto a depth of 30 m. may be developed for residential purpose on condition that the owner should provide infrastructural facilities such as septic tank, drainage, water supply etc. at his own cost.
10.7.2
Manori-Gorai-Uttan Notified Area Special Development Control Regulations sanctioned for the Manori-Gorai-Uttan Notified Area as amended from time to time shall be applicable for the development/ redevelopment in the said notified area being a special Tourism Development Plan sanctioned for this notified area.
10.8
ULHASNAGAR CITY MUNICIPAL CORPORATION Regulations of unauthorised development in Ulhasnagar City Municipal Corporation shall be governed by the Regularisation of Unauthorised Developments in the City of Ulhasnagar Act, 2006.
10.910.9.1
KOLHAPUR MUNICIPAL CORPORATION Open spaces, area, FSI and height limitations for characteristic specified areas in Kolhapur. For characteristic specified areas in Kolhapur, listed herein below, shall have the open spaces and regulations for FSI and height limitations as given in table No. 10 B. below :-
TABLE NO - 10 B.
TABLE NO - 10 B.
TABLE NO - 10 B.
TABLE NO - 10 B.
TABLE NO - 10 B.
TABLE NO - 10 B.
TABLE NO - 10 B.
Sr. No.
Particulars of Areas
Minimum size of plot
Marginal distance to be observed
Marginal distance to be observed
Marginal distance to be observed
Permissible Max. built-up area
Sr. No.
Particulars of Areas
Minimum size of plot
Front
Rear
Side
Permissible Max. built-up area
1
2
3
4
5
6
7
1
Rajarampuri almost all plots are of 40 x 78 except corner plots of 80 x 78
40 x 78 = 3120 Sq.ft. (12.16 m. x 23.77 m.) 294 Sq.m.
10.0(3.05 m.)
2.0(0.60 m.)
2.6(0.76 m.)
-
2
Shahupuri Commercial lane 30 x 75 (9.12 m. x 22.86 m.) or 40 x 75 (12.16 m. x 22.86 m.) Part of old cantonment (new Shahupuri) Shown as ABCDE on Development Plan.
30 x75 = 2250 Sq.ft. ( 9.12 m. x 22.86 m.)
1.0(0.305m)
1.0(0.305m)
1.06
-
Shahu Road
40 x 75 = 3000 Sq.ft. (12.216m. x 22.86 m)
1.0(0.305m)
1.0(0.305m)
2.6
-
Other lanes (12.16 m. x 24.30 m.)
40 x80 = 3200 Sq.ft. ( 0.305 m.)
1.0(0.305m)
1.0(0.305m)
2.6
-
3
Laxmipuri
80 x160 = 12800 Sq.ft. ( 24.3m x48.64m)
20.0(6.00m)
5.0(1.52 m)
5.0(1.52 m)
-
50 x100 = 5000 Sq.ft.( 15.2 m x 30.48m)
10.0(3.05m)
2.6(0.76 m)
2.6(0.76 m)
-
40 x80 = 3200 Sq.ft. (12.16m x 24.3m)
5.0(1.52m)
2.6(0.76 m)
2.6(0.76 m)
4
Subhash road (South side Uma Talkies
40 x100 = 4000 Sq.ft. ( 12.16 m x 30.4 m)
10.0(3.05m)
3.0(0.91 m)
5.0(1.52 m)
-
Gokhale College
Upto 3000 Sq.ft.
10.0(3.05m)
3.0(0.91m)
5.0(1.52m)
-
5
Balbag Vashant
80 x 120 = 9600 Sq.ft. ( 24.32 m x 36.48m)
15.0(4.56 m )
10.8(3.04 m)
5.0(1.52 m)
-
6
Muskuti Talao
40 x 80 = 3200 Sq.ft. ( 12.16 m x 24.32 m )
5.0(1.52m)
2.6(0.76 m)
2.6(0.76 m)
-
7
Old cantonment (New Shahupuri) Remaining part area excluding in Sr. No. 2
80 x 120 = 9600 Sq.ft. ( 24.32 m x 36.48m)
2.6(0.76m)
2.6 (0.76m)
2.6(0.76 m)
-
40 x 80 = 3200 Sq.ft. ( 12.16 m x 24.32 m )
2.6(0.76m)
2.6(0.76m)
2.6(0.76m)
8
Patankar Colony
80 x 120 = 9600 Sq.ft. ( 24.32 m x 36.48m)
-
-
-
-
Main Road
10.0(3.05m)
3.0(0.91m)
5.0(1.52m)
-
Other Roads
5.0(1.52m)
2.6(0.76 m)
2.6(0.76 m)
-
9
Rajarampur New vasahat East side of Tararani vidyapeeth
40 x 80 = 3200 Sq.ft. ( 12.16 m x 24.32 m )
10.0(3.05m)
3.0(0.91m)
5.0(1.52m)
-
10
Petala New Mahadwar Road
40 x100 = 4000 Sq.ft. ( 12.16 m x 30.4 m) Other plots interior roads.
5.0( 1.52m)
3.0( 0.91m)
5.0( 1.52m)
-
11
Tarabai Park
5000 Sq.ft. and above ( 460 Sq.m.)
15.0(4.56 m )
10.0(3.05)
10.0(3.05m)
-
3000 Sq.ft. to 5000 Sq.ft. ( 278.5 Sq.m. to 460 Sq.m.)
15.0(4.56 m )
10.0(3.05)
7.6(2.25 m)
-
12
Shahaji Nagar
5000 Sq.ft. ( 460 Sq.m.)
15.0(4.56 m )
10.0(3.05)
10.0(3.05m)
-
13
Sykes Extension
80 x 120 = 9600 Sq.ft. ( 24.32 m x 36.40m)
15.0(4.56 m )
10.0(3.05)
10.0(3.05m)
-
CTS no. 1143, E
60 x 70 = 3200 Sq.ft. ( 18.29 m x 21.33 m )
10.0(3.05m)
5.0(1.52m)
5.0(1.52m)
-
CTS no. 1141, E
40 x 80 = 3200 Sq.ft. ( 12.16 m x 24.32 m )
5.0(1.52m)
2.6(0.76 m)
2.6(0.76 m)
-
14
Old Gavat Mandai opposite Jijamata Girls High School
40 x 80 = 3200 Sq.ft. ( 12.16 m x 24.32 m ) and other Plots.
10.0( 3.04m)
2.6( 0.76 m)
2.6( 0.76 m)
-
15
Subhash Nagar
40 x60 = 2400 Sq.ft. (12.16 m x 10.24m)
5.0( 1.52m)
2.6( 0.76 m)
2.6( 0.76 m)
-
16
Jawahar Nagar
40 x60 =2400 Sq.ft. (12.16 m x 10.24m)
10.0( 3.05m)
5.0( 1.52m)
5.0( 1.52m)
-
17
Line Bazar near Masjid
40 x90= 3600 Sq.ft. (12.16 m x 27.42m))
10.0( 3.05m)
2.6( 0.60 m)
2.6( 0.76 m)
-
18
Shivaji Udyam Nagar (Industrial use only permitted except to residential use already in use)
80 x 120 = 9600 Sq.ft. ( 24.32 m x 36.48m)
20.0(6.10 m)
3.6(1.064m)
2.6(0.76m)
-
40 x 80 = 3200 Sq.ft. ( 12.16 m x 24.32 m )
5.0(1.52m)
2.6( 0.76 m)
2.6( 0.76 m)
-
On Rajaram Road 80 x80 = 6400 Sq.ft. ( 24.32 m x 24.32m)
5.0( 1.52m)
3.6(1.064m)
5.0( 1.52m)
-
40 x 80 = 3200 Sq.ft. ( 12.16 m x 24.32 m )
5.0( 1.52 m)
3.6( .064m)
5.0( 1.52m)
-
CTS No. 1325
40 x 80 = 3200 Sq.ft. ( 12.16 m x 24.32 m )
5.0(1.52m)
2.6( 0.76 m)
2.6( 0.76 m)
-
CTS No. 1243/2 to 1243/4 for foundry use. Power Nagar, Udyam nagar extension
20.0(6.10 m)
5.0( 1.52m)
5.0( 1.52m)
-
19
Dhor Vasahant
80x 160 = 12800 Sq.ft. ( 24.32 m x 48.64m)
15.0( 4.56 m)
10.0( 3.05 m)
5.0( 1.52 m)
-
20
Town Planning Scheme
Kolhapur No. 1 Special
-
-
-
-
For final Plots
Upto 2 Gunthas ( less than 2 area)
5.0( 1.52 m)
5.0( 1.52 m)
2.06(0.76m)
50%
For final Plot
2 Gunthas to 5 gunthas ( 2 Ares to 5 areas)
10.0( 3.05m)
5.0( 1.52m)
5.0( 1.52m)
50%
For final Plots
5 gunthas (5 Ares)
15.0( 4.5 m )
15.0(4.56 m )
10.0( 3.05 m)
33%
21
Town Planning Scheme Kolhapur No. II Special Regulations.
Town Planning Scheme Kolhapur No. II Special Regulations.
Town Planning Scheme Kolhapur No. II Special Regulations.
Town Planning Scheme Kolhapur No. II Special Regulations.
Town Planning Scheme Kolhapur No. II Special Regulations.
Town Planning Scheme Kolhapur No. II Special Regulations.
B)
Excepting above further final plots
15.0(4.56 m)
15.0(4.56 m)
5.0( 1.52m)
33%
22
Two planning Scheme Kolhapur No. III Special Regulations.
Sakoli Vasahat to the South West of Rankala S.T. Stand
As per gaothan regulation
1.0(0.305m)
1.6(0.457m)
-
28
Timber Market
100x150 - 15000 Sq.ft. ( 30.48 m x 45.72m)
15.0(4.56 m)
15.0(4.56 m)
15.0 (4.56m)
-
29
Golibar Vasahat K Bavada
40 x 40 = 1600 Sq.ft. ( 12.16 m x 12.16m )
2.6( 0.76 m)
2.6( 0.76 m)
2.6( 0.76 m)
-
30
Patharvat Vasahat Near Daulat Nagar
30 x 50 = 1500 Sq.ft. ( 9.14 m x 15.24 m )
5.0( 1.52m)
2.6( 0.76 m)
2.6( 0.76 m)
-
31a) b)
Old Vasahats Dombar Wada Takala portion on Koti-tirth
Gaothan Regulation would be applicable
-
-
-
-
32
Sotewala Vasahat
5.0( 1.52m)
2.0( 0.60 m)
2.6( 0.76 m)
-
33
Nagala Area of Tarbai Park
5000 Sq.ft. and above ( 460 Sq.m.& above)
15.0(4.56 m)
10.0( 3.05 m)
10.0( 3.05 m)
33%
3000 Sq.ft. to 5000 Sq.ft. (278.5 Sq.m. to 460 Sq.m.)
15.0(4.56 m)
10.0( 3.05 m)
7.6(2.25 m)
33%
34
Hind co-Operative Housing Society (Ruikar Colony)
65 x 80 = 52000 Sq.ft. ( 19.81 m x 24.36 m )
10.0(3.05 m)
-
7.0(2.135m)
-
60 x 90 = 5400 Sq.ft. ( 18.91m x 27.42m )
15.0(4.56 m)
5.0(1.52 m)
7.0(2.135m)
-
35
Dinanath Mangeshkar Nagar - site No. 272 & 273
i) 1500 to below 2000 Sq.ft. (139.35 Sq.m. to 185.80 Sq.m.)
10.0 (3.05 m)
5.0(1.52 m)
5.0(1.52 m)
1/2
ii) 2000 to below 3000 Sq.ft. (185.0 Sq.m. to 278.7 Sq.ft.)
10.0( 3.05 m)
10.0( 1.52 m)
5.0( 1.52 m)
1/2
iii) 3000 to below 5000 Sq.ft. ( 278.7 Sq.m. to 464.5 Sq.m.)
15.0(4.56 m)
10.0( 3.05 m)
7.6(2.25 m)
1/2
36
Sagarmal ( S.No. 1330) E Ward, site No. 338)
do
do
do
do
do
37
R.S. No. 690 site No. 365
400 Sq.ft.( 37016 Sq.m.) 400 to 784 Sq.ft. ( 37016 to 67.03 Sq.m.)
Gaothan Regulatio n shall be applied5.0(1.52m)
-2.0(0.60m)
-2.6(0.76m)
-
38
Site No. 87 ( Housing the Dishoused)
AS mentioned in sr.no.l35
AS mentione d in sr.no.l35
-
-
-
39
R.S. No 711 K, Karveer
500 to 1000 Sq.ft. ( 46.45 to 92.90 sq.mt.)
5.0( 1.52m)
-
3.0( 0.9 m ) on one side2.6(Common distance ( 0.76m)
-
40
Remanmala Zopadpatti
1800 to 2000 Sq.ft. ( 1167.22 to 185.8 Sq.m.)
5.0(1.52 m)
2.6( 0.76 m)
2.6( 0.76 m)
1/2
41
Site No. 60
50 x 30 = 1500 Sq.ft. (15.24 m x 9.14 m)
5.0(1.52 m)
2.6(0.76 m)
2.6( 0.76 m)
1/2
42
Daulat Nagar
1500 Sq.ft. ( 139.35m)
5.0(1.52 m)
2.6(0.76 m)
2.6( 0.76 m)
1/2
Note 1 – Maximum permissible Basic FSI for Sr. No. 1 to 3 and 26, 27 and 31 shall be 1.5 for residential use and 2.0 for residential cum-Commercial use and for remaining areas, it shall be 1.1 and mix non-residential use to be allowed without any restriction of percentage.
Note 2 – The properties fronting on ― Mahadwar to Mahadwar Chowk Road ― shall be given building permission with a front set back of only 0.5 m.
Note 3 – The Maximum permissible Basic FSI, permissible TDR loading and additional FSI on payment of premium shall be as allowed as per these regulations.
Note 4 – Height of building
i) Height of building to be constructed on Kiranotsav Marg of Mahalaxmi Temple shall be determined by the Municipal Commissioner.
For Sr. No. 1, 2 & 3 – upto 21 m. height with marginal distances as per column No. 4, 5 & 6 of table above. Above 21 m. height - it shall be as per Regulation No. (1) 6.1.1(iii), (vi) or Regulation No.6.2.3, as the case may be.
iii) For Sr. No. 4 to 42 upto 15 m. as per column No 4, 5 & 6 of table above.
For height above 15 m., 1.0 m. set-back for every 3 m. height on all sides except front for open plot. For the existing structures and ongoing projects only front and rear set-back to be kept in addition to the marginal open spaces as per column No. 4, 5 & 6 of table above. This may be allowed in form of step margin. Side margin as mentioned in column No. 6 of table above, may be continued upto 21 m. height.
Above 21 m. height - it shall be as per Regulation No. (1) 6.1.1(iii), (vi) or Regulation No.6.2.3, as the case may be.
Note - 5 Other provisions excluding above, shall be as per UDCPR.
Note - 6 For parking spaces in basement and upper floor at least one vehicular ramp of 3.00m. width in side and rear margin for 4 wheeler ( )and for 2 wheeler or one vehicular ramp of 2 m. width for 2 wheeler shall be provided for plot area upto 1000 Sq.m. (2)or the owner may provide minimum 2 Car lifts instead of Ramp.
10.9.2 Height of building on Kiranotsav Marg other than specified area.
204
The height of building to be constructed along Kiranotsav Marg of Mahalaxmi Temple shall be determined by the Municipal Commissioner.