Chapter 6General Building Requirements – Setback, Marginal Distance, Height and Permissible FSI
6.0 General
Following regulations shall be applicable for the lands included in congested area (or core area) as shown on the Development Plan. These regulations shall also be applicable for the gaothan areas in Regional Plans (including the areas of Local Bodies and Special Planning Authorities where Development Plan or Planning Proposal is not sanctioned).
However, in congested area, if the original land holding is more than 0.40 Hectare, then regulations of non-congested area, except FSI, shall apply. FSI in such cases shall be as per the Regulation No.6.1.1
6.1Regulations for Congested Area in Development Plans / Gaothans of Village Settlements in Metropolitan Region Development Authorities and Regional Plans.
(Note - In Nashik Municipal Corporation, the term ‗Core Area‘ is synonymous to ‗Congested Area‘.)
6.1.1 Residential Buildings/ Residential Buildings with mixed-use
i) Floor Space Index:-
The maximum permissible basic floor space index, FSI on payment of premium, permissible TDR loading shall be as per the following Table No. 6A.
Note for Table No. 6 A :
In addition to what is mentioned in Table No. 6 A, ancillary area FSI upto the extent of 60%of the proposed FSI in the development permission (including Basic FSI, Premium FSI, TDR but excluding the area covered in Regulation No.6.8) shall be allowed with the payment of premium at the rate as specified below on the land rate in Annual Statement of Rates of the said land without considering the guidelines therein. This shall be applicable to all buildings in all zones.
Sr. No.
Authority / Area
Rate of Premium.
1
Pune and Thane Municipal Corporation.
15%
2
Nagpur, Nashik Municipal Corporation and Municipal Corporations in MMR (except Thane) and Metropolitan Development Authority area (<sup>1</sup>) and CIDCO as Planning Authority by virtue of NTDA.
10%
3
All other Municipal Corporations.
10%
4
Municipal Councils, Nagar Panchayats and R.P. area.
10%
Provided that in case of non-residential use, the extent of ancillary area FSI shall be upto 80%.No separate calculation shall be required to be done for this ancillary area FSI. Entire FSI in the development permission shall be calculated and shall be measured with reference to permissible FSI, premium FSI, TDR, additional FSI including ancillary area FSI added therein.
(1) Inserted vide Notification u/s 37 (1AA)(c) No. CR 236/18 (Part 6), dt. 12th October 2022.
Provided further that, the above mentioned rates shall not exceed the rate of premium mentioned in column 4 of Table 7 A under Chapter-7 where the development permission is sought for the uses mentioned in the said table.
Provided further that, this ancillary area FSI shall be applicable to all other schemes like TOD, PMAY, ITP, IT, MHADA, etc. except (1) Rehabilitation component in SRA. In the result, free of FSI items in the said schemes, if any, other than mentioned in UDCPR, shall stand deleted.
All notes mentioned below Table 6-G of Regulation No. 6.3 shall be applicable, mutatismutandis.
Utilisation of ancillary area FSI is optional. It can be used fully/ partly.
In case of composite building of mixed users premium and ancillary area FSI shall be on prorate basis.
Table No.6 A
Sr. No.
Road width in meter
Basic FSI
For all Municipal Corporations and (2)CIDCO as Planning Authority by Virtue of NTDA
For remaining authorities/areas
FSI on payment of premium
Maximu m permissib le TDR loading
Maximum building potential on plot
FSI on payment of premium
Maximu m permissi ble TDR loading
Maxi mum build ing pote ntial on plot
1
2
3
4
5
6
7
8
9
1
Below 9.0 m.
1.50
--
--
1.50
--
--
1.50
2
9.00 m. and below 18.00 m.
2.00
0.30
0.30
2.60
0.30
0.10
2.40
3
18.00 m. and below 30.00 m.
2.00
0.30
0.50
2.80
0.30
0.20
2.50
4
30.00 m. and above
2.00
0.30
0.70
3.00
0.30
0.20
2.50
ii) Front Marginal Distances/Setback/ Roadside Margin/s in Congested Area
The minimum front setback from the existing or proposed road/ roads shall be as per the following Table No. 6B.
Table No. 6B.
Sr. No.
Road width
For Residential building
For Residential Buildings with mixed-use
(i)
For streets/lane less than 4.5 m. width
2.25m. from the centre of the street/ lane
2.25m. + 1.50 m from the centre of the street/lane
(ii)
For streets 4.5m. to less than 6.00 m. in width
NIL
1.50 m.
(1) Inserted Vide Addendum No.CR 236/18, dt. 14th January, 2021.
(iii)
For streets 6 m. to less than 12 m. in width
1.00 m.
2.00 m.
(iv)
For streets 12 m. in width and above
2.00 m.
2.50 m.
iii) Side and Rear Marginal Distances in Congested Area
The minimum side and rear marginal distances shall be as per the following Table No. 6C.
Table No. 6C.
Plot Area
Side
Rear
Up to 1000 Sq.m.
0.00
0.00
Above 1000& upto 4000 Sq.m.
1.00 m.
1.00 m.
Above 4000 Sq.m.
As per Regulation for non-congested area
Note:-
For light and ventilation, provisions about interior & exterior chowks shall apply.
Irrespective of the area of a plot, if the width thereof is 7m. or less, then the side margin shall be nil.
For the lanes having width less than 4.5m. abutting to any side of plot, a setback of 2.25m. from the centre of lane shall be provided to make such lane 4.5m. wide. No projections shall be permissible on such widened lane.
v) Excepting the FSI and its maximum loading limit & marginal distances as prescribed above, all other regulations shall be applicable for development permission in congested area.
vi) Height: Above setback and marginal distances shall be applicable for buildings less than 15m. in height. Marginal distances shall be increased by 1m.for buildings having height 15m. and more but less than 24m. For buildings having height 24m. and more, marginal distances shall be as per regulations of non-congested area.
6.1.2 Other buildings like Public/ Semi-Public, Educational, Medical, Institutional, Commercial, Mercantile, etc.
(a) Floor Space Index, – The FSI permissible for these buildings shall be as per Regulation No.6.1.1.
(b) Marginal Distances - For these buildings marginal distances shall be 3m. on all sides including front up to 24m. height.
Provided that for building more than 24 m. height, regulations of non-congested area shall apply.
Provided further that, for buildings like cinema theatres, multiplex, assembly buildings, shopping malls etc., regulations for outside congested area, except FSI, shall apply.
6.1.3 Pathway for access to internal building or interior part of the building shall not be less than 3.6 m. in width.
6.1.4 Front setback (marginal distance) as prescribed under highway or any other rules shall be applicable if they are over and above as prescribed in these regulations.
6.2Regulations for Outside Congested Area (non-congested Area).
6.2.1 Marginal Distances and set-back for Residential Buildings and mixed use with Height up to 15 m. or as mentioned in the Table No. 6-D.
The provisions for minimum marginal distances as given in Table No. 6-D below shall apply for the Residential buildings, Residential with mixed uses permissible in Residential Zone and Residential buildings permissible in other zones.
Table No.6-D
Table No.6-D
Table No.6-D
Table No.6-D
Table No.6-D
Table No.6-D
Table No.6-D
Table No.6-D
Sr. No
Description of the road
Min Plot Size in Sq.m.
Min width of plot in meters
Min setback from road side in meters
Min. side margins in meters
Min. rear margi ns in meters
Remarks
1
2
3
4
5
6
7
8
1
Roads of width 30 m. and above in local authority area.
450
15
6.0in case of A, B, C class Municipal Corporations and 4.50 in case of other areas.
3.0
3.0
Side and Rear Margins for building upto 15m. height (excluding parking floor upto 6m. height)
2
In case of Regional Plan area. NH/SH
450
15
4.5m.or as specified by Highway rules whichever is more.
3.0
3.0
Side and Rear Margins for building upto 15m. height (excluding parking floor upto 6m. height)
3
Roads of width 18 m. and above but below 30 m.
250
10
4.5
2.0
2.0
Side and Rear Margins for building upto 10m. height (excluding parking floor upto 6m. height)
4
Roads of width 15 m. and above but below 18m.
200
10
3.0
1.5
1.5
Margins for buildings G+2 or stilt +3 structure
5
Roads of width less than 15m.
80
6
3.0
1.5(in case of semi-detached building, only one side marginal distance shall be permissible
1.5
Margins for buildings G+2 or stilt+ 3structure
6
Row Housing on roads of 12m. and below
30
3.5
2.25
0.0(In case of corner plot, 1.50 or building line of adjoining road whichever is more)
1.5
--do--
7
Row Housing for EWS/ LIG/ by public authority / private individual / Slum Upgradation etc. by public authority
20
3.0
0.9 from pathway or 2.25 from road boundary
0.0(In case of corner plot, 1.5 or building line of adjoining road whichever is more)
0.9
G+1 or stilt+ 2structure only
Notes:-
(1) The width of the road in above table shall govern the requirements in column 3 to 8.
(2) In case of Sr. No. 1 to 6 structures having higher height may be permitted subject to marginal distance mentioned in Regulation No.6.2.3.
(3) The minimum area of plots fronting on service roads along highways shall be with reference to the actual width of the service road.
(4) For semi-detached buildings, side margin shall be on one side only. Plots for semi-detached buildings shall be in pairs.
(5) Row-housing plots at the junction of two roads shall be larger to maintain the setback from both roads. Not more than 12 and not less than 3 plots shall be allowed in each block of row housing. Each block shall be separated from the other by a 4.5 m. wide road / pathway
or 4.5m. side marginal distance within the plot or space including side marginal distance of the plot.
(6) No garage shall be permitted in a building having stilt or basement provided for parking.
(7) Construction of ottas, railings, barricades or supporting columns for canopy or porch shall not be allowed in minimum front marginal distances. However, steps may be permitted within 1.2m. from the building line. Also supporting columns for canopy or porch may be allowed within building line.
(8) In case of Regional Plan areas, ribbon development rules shall not be relaxed without consent of the Highway Authority.
(9) In case of special building, marginal distances shall be as per regulations for such buildings.
(10) The plot width to depth ratio shall be 1:1.5 to 1:2.5, as far as possible in plotted layout.
(11) In Public Housing Schemes for E.W.S. undertaken by government or semi-government organizations, marginal distances shall be as per the respective schemes and rules.
(12) The front setback set-out in already approved and partially developed layouts/ schemes, may be retained as per original approval, so as to maintain the building line.
(13) The pattern of development like semi-detached, row housing etc. in already approved layout shall be as per said approved layout.
(14) Where commencement certificate is granted prior to publication of draft development plan or sanction of Development Plan and the plot gets affected by new road / road widening, proposed in the development plan, the front margin shall stand relaxed to that extent.
(15) In case of redevelopment proposal affected by line of street up to 9 m. width under Municipal Council or Municipal Corporation Act or development plan road of up to 9 m. width, the front margin shall stand relaxed to the extent of land affected by such proposal (1) subject to minimum setback of 1.0 m. for roads having width 12.0 m. or less and 2.0 m. for roads having width more than 12.0 m., from the final line of the street.
(16) Subsidiary structure such as garage (limited to one), outhouse and independent sanitary block may be permitted only in plots having area 250sq.m.or more.
(17) Rear or side marginal distances for development along nallah or watercourses shall be subject to Regulation regarding ―Sites Not Eligible for Construction of Building‖ and ―Construction Within Flood Line‖.(Chapter 3)
(18) The plots which are substandard in area shall be developed as per marginal distances mentioned in the above table with reference to road width.
118
(19) In case of plots having approach by dead-end road, (point access) front margin shall be limited to width of point access.
(2) (20) Building Line along classified roads as mentioned in regulation no.3.1.6 shall be applicable for residential buildings defined in Regulation No.1.3.93 (i) and Control Line along classified roads shall be applicable for other uses or for commercial uses as mentioned in regulation no.3.1.6 or for mixed use buildings where non-residential uses are proposed at least 50 % or more of total proposed built-up area.
(1) Inserted Vide Corrigendum / Addendum No.CR 79/2021, dt. 02nd December 2021.