Chapter 6General Building Requirements – Setback, Marginal Distance, Height and Permissible FSI
6.0 General
Following regulations shall be applicable for the lands included in congested area (or core area) as shown on the Development Plan. These regulations shall also be applicable for the gaothan areas in Regional Plans (including the areas of Local Bodies and Special Planning Authorities where Development Plan or Planning Proposal is not sanctioned).
However, in congested area, if the original land holding is more than 0.40 Hectare, then regulations of non-congested area, except FSI, shall apply. FSI in such cases shall be as per the Regulation No.6.1.1
6.1Regulations for Congested Area in Development Plans / Gaothans of Village Settlements in Metropolitan Region Development Authorities and Regional Plans.
(Note - In Nashik Municipal Corporation, the term ‗Core Area‘ is synonymous to ‗Congested Area‘.)
6.1.1 Residential Buildings/ Residential Buildings with mixed-use
i) Floor Space Index:-
The maximum permissible basic floor space index, FSI on payment of premium, permissible TDR loading shall be as per the following Table No. 6A.
Note for Table No. 6 A :
In addition to what is mentioned in Table No. 6 A, ancillary area FSI upto the extent of 60%of the proposed FSI in the development permission (including Basic FSI, Premium FSI, TDR but excluding the area covered in Regulation No.6.8) shall be allowed with the payment of premium at the rate as specified below on the land rate in Annual Statement of Rates of the said land without considering the guidelines therein. This shall be applicable to all buildings in all zones.
Sr. No.
Authority / Area
Rate of Premium.
1
Pune and Thane Municipal Corporation.
15%
2
Nagpur, Nashik Municipal Corporation and Municipal Corporations in MMR (except Thane) and Metropolitan Development Authority area (<sup>1</sup>) and CIDCO as Planning Authority by virtue of NTDA.
10%
3
All other Municipal Corporations.
10%
4
Municipal Councils, Nagar Panchayats and R.P. area.
10%
Provided that in case of non-residential use, the extent of ancillary area FSI shall be upto 80%.No separate calculation shall be required to be done for this ancillary area FSI. Entire FSI in the development permission shall be calculated and shall be measured with reference to permissible FSI, premium FSI, TDR, additional FSI including ancillary area FSI added therein.
(1) Inserted vide Notification u/s 37 (1AA)(c) No. CR 236/18 (Part 6), dt. 12th October 2022.
Provided further that, the above mentioned rates shall not exceed the rate of premium mentioned in column 4 of Table 7 A under Chapter-7 where the development permission is sought for the uses mentioned in the said table.
Provided further that, this ancillary area FSI shall be applicable to all other schemes like TOD, PMAY, ITP, IT, MHADA, etc. except (1) Rehabilitation component in SRA. In the result, free of FSI items in the said schemes, if any, other than mentioned in UDCPR, shall stand deleted.
All notes mentioned below Table 6-G of Regulation No. 6.3 shall be applicable, mutatismutandis.
Utilisation of ancillary area FSI is optional. It can be used fully/ partly.
In case of composite building of mixed users premium and ancillary area FSI shall be on prorate basis.
Table No.6 A
Sr. No.
Road width in meter
Basic FSI
For all Municipal Corporations and (2)CIDCO as Planning Authority by Virtue of NTDA
For remaining authorities/areas
FSI on payment of premium
Maximu m permissib le TDR loading
Maximum building potential on plot
FSI on payment of premium
Maximu m permissi ble TDR loading
Maxi mum build ing pote ntial on plot
1
2
3
4
5
6
7
8
9
1
Below 9.0 m.
1.50
--
--
1.50
--
--
1.50
2
9.00 m. and below 18.00 m.
2.00
0.30
0.30
2.60
0.30
0.10
2.40
3
18.00 m. and below 30.00 m.
2.00
0.30
0.50
2.80
0.30
0.20
2.50
4
30.00 m. and above
2.00
0.30
0.70
3.00
0.30
0.20
2.50
ii) Front Marginal Distances/Setback/ Roadside Margin/s in Congested Area
The minimum front setback from the existing or proposed road/ roads shall be as per the following Table No. 6B.
Table No. 6B.
Sr. No.
Road width
For Residential building
For Residential Buildings with mixed-use
(i)
For streets/lane less than 4.5 m. width
2.25m. from the centre of the street/ lane
2.25m. + 1.50 m from the centre of the street/lane
(ii)
For streets 4.5m. to less than 6.00 m. in width
NIL
1.50 m.
(1) Inserted Vide Addendum No.CR 236/18, dt. 14th January, 2021.
(iii)
For streets 6 m. to less than 12 m. in width
1.00 m.
2.00 m.
(iv)
For streets 12 m. in width and above
2.00 m.
2.50 m.
iii) Side and Rear Marginal Distances in Congested Area
The minimum side and rear marginal distances shall be as per the following Table No. 6C.
Table No. 6C.
Plot Area
Side
Rear
Up to 1000 Sq.m.
0.00
0.00
Above 1000& upto 4000 Sq.m.
1.00 m.
1.00 m.
Above 4000 Sq.m.
As per Regulation for non-congested area
Note:-
For light and ventilation, provisions about interior & exterior chowks shall apply.
Irrespective of the area of a plot, if the width thereof is 7m. or less, then the side margin shall be nil.
For the lanes having width less than 4.5m. abutting to any side of plot, a setback of 2.25m. from the centre of lane shall be provided to make such lane 4.5m. wide. No projections shall be permissible on such widened lane.
v) Excepting the FSI and its maximum loading limit & marginal distances as prescribed above, all other regulations shall be applicable for development permission in congested area.
vi) Height: Above setback and marginal distances shall be applicable for buildings less than 15m. in height. Marginal distances shall be increased by 1m.for buildings having height 15m. and more but less than 24m. For buildings having height 24m. and more, marginal distances shall be as per regulations of non-congested area.
6.1.2 Other buildings like Public/ Semi-Public, Educational, Medical, Institutional, Commercial, Mercantile, etc.
(a) Floor Space Index, – The FSI permissible for these buildings shall be as per Regulation No.6.1.1.
(b) Marginal Distances - For these buildings marginal distances shall be 3m. on all sides including front up to 24m. height.
Provided that for building more than 24 m. height, regulations of non-congested area shall apply.
Provided further that, for buildings like cinema theatres, multiplex, assembly buildings, shopping malls etc., regulations for outside congested area, except FSI, shall apply.
6.1.3 Pathway for access to internal building or interior part of the building shall not be less than 3.6 m. in width.
6.1.4 Front setback (marginal distance) as prescribed under highway or any other rules shall be applicable if they are over and above as prescribed in these regulations.