Chapter 6General Building Requirements – Setback, Marginal Distance, Height and Permissible FSI
6.0 General
Following regulations shall be applicable for the lands included in congested area (or core area) as shown on the Development Plan. These regulations shall also be applicable for the gaothan areas in Regional Plans (including the areas of Local Bodies and Special Planning Authorities where Development Plan or Planning Proposal is not sanctioned).
However, in congested area, if the original land holding is more than 0.40 Hectare, then regulations of non-congested area, except FSI, shall apply. FSI in such cases shall be as per the Regulation No.6.1.1
6.2.2Other Buildings
The Provision in respect of minimum road width, minimum marginal distances etc., as given in Table No.6E below shall apply for different categories of other buildings.
Table No.6 E
Table No.6 E
Table No.6 E
Table No.6 E
Table No.6 E
Sr. No
Type of building
Minimum road width required
Minimum marginal distances
Other stipulations
1
2
3
4
5
1
Medical buildings
Medical buildings
Medical buildings
Medical buildings
a) Hospital, Maternity Homes, Health Club, Clinics etc. buildings not being special buildings
9 m. in case of A, B, C class Municipal Corporation, Metropolitan Authority Area and 7.5 m. in case of other areas.
Margins as per Table No. 6 D subject to side marginal distance of minimum3m.
NIL
b) Hospital, Maternity Homes, Health Club etc. buildings under category of special building.
Road width as required for Special Buildings. (RegulationNo.3.3.9)
6 m. on all sides
Height of building subject to provisions of Maharashtra Fire Prevention and Life Safety Measures Act 2006.
2.
Educational buildings
Educational buildings
Educational buildings
Educational buildings
a) Pre-primary School
On any road.
Margins as per Table No. 6 D
Other requirements shall be as mentioned in the Table No.7A of Regulation No. 7.1. Height of building subject to provisions of Maharashtra Fire Prevention and Life Safety Measures Act 2006.
b) Primary School not being special building.
6 m.
--do--
Other requirements shall be as mentioned in the Table No.7A of Regulation No. 7.1. Height of building subject to provisions of Maharashtra Fire Prevention and Life Safety Measures Act 2006.
c) Other Educational Buildings not being special building.
9 m.
3 m. on all sides
Other requirements shall be as mentioned in the Table No.7A of Regulation No. 7.1. Height of building subject to provisions of Maharashtra Fire Prevention and Life Safety Measures Act 2006.
d) Any building of category a, b, c above being special building.
Road width as required for Special Buildings
6 m. on all sides
Other requirements shall be as mentioned in the Table No.7A of Regulation No. 7.1. Height of building subject to provisions of Maharashtra Fire Prevention and Life Safety Measures Act 2006.
3.
Public-Semi Public Building
Public-Semi Public Building
Public-Semi Public Building
Public-Semi Public Building
a) Public-Semi Public Building not being special building.
9 m.
Margins as per Table No.6D subject to side marginal distance of minimum 3 m
.--
a) Public-Semi Public Building being special building.
Front - 12m.(only on one major road).6m. on all remaining sides
i) In case of cities having population more than 2.5 lakhs as per latest census, redevelopment of existing cinema theatre on plots shall be allowed subject to the condition that at least 1/3rd of the existing seats shall be retained, which shall not be below 150 seats and may be developed in combination with user permissible in R2 zone.ii) For redevelopment of existing theatre, marginal distances including front margin as per these regulations shall not be insisted. Redevelopment shall be allowed as per existing set back distances. Parking area required as per these regulations shall not be insisted; however existing parking area shall be maintained.iii) In cases where redevelopment of existing Cinema Theatre is carried out on the same place with the capacity more than existing capacity in the form of single or multiscreen cinemas, then owner / developer shall be allowed FSI potential mentioned in column 6 or 9, as the case may be, of Table No.6-G at the rate of 20% land rate mentioned in Annual Rates of Statement without considering guidelines therein, for the additional capacity.iv) The existing Cinema Theatre shall be allowed to be relocated and constructed at some other place within a distance of 5 km. In such case, original site shall be allowed to be developed as per uses permissible in adjoining zone. Construction of Cinema Theatre / Multiplex shall conform to the provisions of Maharashtra Cinema (Regulations) Rules, 1966 and as amended from time to time, except the provisions mentioned above.
v) For redevelopment of Cinema plot having area less than 1000 Sq.m., and if redevelopment of existing cinema theatre on such plot is not possible considering the other requirements in these regulations, the condition of providing atleast 1/3 of the existing seats or minimum 150 seats for cinema theatre shall not be insisted. In such case users permissible in adjoining predominant zone shall be permissible with special permission of sanctioning authority.
5.
Mangal Karyalaya
Mangal Karyalaya
Mangal Karyalaya
Mangal Karyalaya
a) Mangal karyalaya and like buildings not under the category of special building.
Road width as required for R-2 zone.
3 m. on all sides.
-
b) Mangal karyalaya and like buildings under the category of special building.
12 m.
6 m. on all sides.
-
6.
(#) Fuel Stations
(#) Fuel Stations
(#) Fuel Stations
(#) Fuel Stations
Fuel Filling Stations/including Petrol/ Ethanol /LPG / CNG /etc., Public Charging Stations for Electric Vehicles with or without service bays
9 m.
4.5m. on all sides
i) In case the plot is located on any Classified road in Regional Plan area, the distance from the junction of roads as may be specified by Indian Road Congress/ Ministry of Road, Transport and Highway, shall be followed. (IRC guideline 2009 and MORTH Letter No.RW/NH-33023/19/99- DOIII, Dated: 25.09.2003 as amended from time to time) ii) NOC from Chief Controller of Explosives shall be necessary.
(#) Clarification issued vide letter No. CR 68/2021 dt., 10thMay, 2021.
(#) Clarification issued vide letter No. CR 68/2021 dt., 10thMay, 2021.
(#) Clarification issued vide letter No. CR 68/2021 dt., 10thMay, 2021.
(#) Clarification issued vide letter No. CR 68/2021 dt., 10thMay, 2021.
(#) Clarification issued vide letter No. CR 68/2021 dt., 10thMay, 2021. iii) In a plot of Fuel Filling Station, other building or composite building for sales office, snack bars, restaurant, public conveniences or like activities may be permitted. The FSI shall not exceed 0.25 and underground structures along with kiosks shall not be counted towards FSI.
7.
Mercantile Buildings.
Mercantile Buildings.
Mercantile Buildings.
Mercantile Buildings.
a) Mercantile/ Business/ Hotel/ Commercial building under the category of special buildings.
Road width as required for Special Building.
Front 6m. Side & rear 6m.
i) Shops may also face on side and rear of a plot. ii) Minimum width and area of Shop shall be as per convenience of the owner / developer. iii) In case of construction of shops / offices only on ground floor (not being special building) side and rear marginal distance shall be as per Table No. 6-D.
b) Mercantile/ Business/ Hotel/ Commercial building not under category of special buildings
Road width as required for R-2 zone.
Margins as per Table No. 6-D subject to side marginal distance of minimum3m.
i) Shops may also face on side and rear of a plot. ii) Minimum width and area of Shop shall be as per convenience of the owner / developer. iii) In case of construction of shops / offices only on ground floor (not being special building) side and rear marginal distance shall be as per Table No. 6-D.
c) Convenience shopping in R-1 zone.
On any road.
Margins as per Table No. 6-D.
--
8.
Stadium
Stadium
Stadium
Stadium
Stadium with Pavilion
12m.
6m. on all sides
The covered portion of spectator's gallery shall not exceed 25%of plot area, which shall not be counted towards FSI. Shops below spectator's gallery may be permitted which shall not be counted towards FSI. In addition to this, ancillary office, sportspersons accommodation, public convenience like structures may also be permitted which shall not consume more than 0.10 FSI on gross plot area.
Note :
i) In case of plots fronting on National Highways, State Highways and Major District Roads in Regional Plan area, the building line shall be as per Ribbon Development Rules or as given in Table above, whichever is more.
ii) Side and rear marginal distances mentioned in above Table shall be subject to Regulation No.6.2.3, whichever is more.
iii) In case of special buildings, marginal distances shall be as per regulations for special buildings.
iv) A stadium should desirably accommodate 400 m. running track.
v) For above buildings, permissible FSI shall be as per Regulation No.6.3, unless otherwise specified above.
vi) Point access (approach by dead end road) to a plot shall be considered for the minimum road width requirement mentioned in above table. In such case, front margin shall be applicable for the width of point access road.
vi) The provisions about Cinema Theatre in column 5 of Table No. 6 E shall be applicable to Cinema Theatres in congested area also.
6.1Regulations for Congested Area in Development Plans / Gaothans of Village Settlements in Metropolitan Region Development Authorities and Regional Plans.
(Note - In Nashik Municipal Corporation, the term ‗Core Area‘ is synonymous to ‗Congested Area‘.)
6.1.1 Residential Buildings/ Residential Buildings with mixed-use
i) Floor Space Index:-
The maximum permissible basic floor space index, FSI on payment of premium, permissible TDR loading shall be as per the following Table No. 6A.
Note for Table No. 6 A :
In addition to what is mentioned in Table No. 6 A, ancillary area FSI upto the extent of 60%of the proposed FSI in the development permission (including Basic FSI, Premium FSI, TDR but excluding the area covered in Regulation No.6.8) shall be allowed with the payment of premium at the rate as specified below on the land rate in Annual Statement of Rates of the said land without considering the guidelines therein. This shall be applicable to all buildings in all zones.
Sr. No.
Authority / Area
Rate of Premium.
1
Pune and Thane Municipal Corporation.
15%
2
Nagpur, Nashik Municipal Corporation and Municipal Corporations in MMR (except Thane) and Metropolitan Development Authority area (<sup>1</sup>) and CIDCO as Planning Authority by virtue of NTDA.
10%
3
All other Municipal Corporations.
10%
4
Municipal Councils, Nagar Panchayats and R.P. area.
10%
Provided that in case of non-residential use, the extent of ancillary area FSI shall be upto 80%.No separate calculation shall be required to be done for this ancillary area FSI. Entire FSI in the development permission shall be calculated and shall be measured with reference to permissible FSI, premium FSI, TDR, additional FSI including ancillary area FSI added therein.
(1) Inserted vide Notification u/s 37 (1AA)(c) No. CR 236/18 (Part 6), dt. 12th October 2022.
Provided further that, the above mentioned rates shall not exceed the rate of premium mentioned in column 4 of Table 7 A under Chapter-7 where the development permission is sought for the uses mentioned in the said table.
Provided further that, this ancillary area FSI shall be applicable to all other schemes like TOD, PMAY, ITP, IT, MHADA, etc. except (1) Rehabilitation component in SRA. In the result, free of FSI items in the said schemes, if any, other than mentioned in UDCPR, shall stand deleted.
All notes mentioned below Table 6-G of Regulation No. 6.3 shall be applicable, mutatismutandis.
Utilisation of ancillary area FSI is optional. It can be used fully/ partly.
In case of composite building of mixed users premium and ancillary area FSI shall be on prorate basis.
Table No.6 A
Sr. No.
Road width in meter
Basic FSI
For all Municipal Corporations and (2)CIDCO as Planning Authority by Virtue of NTDA
For remaining authorities/areas
FSI on payment of premium
Maximu m permissib le TDR loading
Maximum building potential on plot
FSI on payment of premium
Maximu m permissi ble TDR loading
Maxi mum build ing pote ntial on plot
1
2
3
4
5
6
7
8
9
1
Below 9.0 m.
1.50
--
--
1.50
--
--
1.50
2
9.00 m. and below 18.00 m.
2.00
0.30
0.30
2.60
0.30
0.10
2.40
3
18.00 m. and below 30.00 m.
2.00
0.30
0.50
2.80
0.30
0.20
2.50
4
30.00 m. and above
2.00
0.30
0.70
3.00
0.30
0.20
2.50
ii) Front Marginal Distances/Setback/ Roadside Margin/s in Congested Area
The minimum front setback from the existing or proposed road/ roads shall be as per the following Table No. 6B.
Table No. 6B.
Sr. No.
Road width
For Residential building
For Residential Buildings with mixed-use
(i)
For streets/lane less than 4.5 m. width
2.25m. from the centre of the street/ lane
2.25m. + 1.50 m from the centre of the street/lane
(ii)
For streets 4.5m. to less than 6.00 m. in width
NIL
1.50 m.
(1) Inserted Vide Addendum No.CR 236/18, dt. 14th January, 2021.
(iii)
For streets 6 m. to less than 12 m. in width
1.00 m.
2.00 m.
(iv)
For streets 12 m. in width and above
2.00 m.
2.50 m.
iii) Side and Rear Marginal Distances in Congested Area
The minimum side and rear marginal distances shall be as per the following Table No. 6C.
Table No. 6C.
Plot Area
Side
Rear
Up to 1000 Sq.m.
0.00
0.00
Above 1000& upto 4000 Sq.m.
1.00 m.
1.00 m.
Above 4000 Sq.m.
As per Regulation for non-congested area
Note:-
For light and ventilation, provisions about interior & exterior chowks shall apply.
Irrespective of the area of a plot, if the width thereof is 7m. or less, then the side margin shall be nil.
For the lanes having width less than 4.5m. abutting to any side of plot, a setback of 2.25m. from the centre of lane shall be provided to make such lane 4.5m. wide. No projections shall be permissible on such widened lane.
v) Excepting the FSI and its maximum loading limit & marginal distances as prescribed above, all other regulations shall be applicable for development permission in congested area.
vi) Height: Above setback and marginal distances shall be applicable for buildings less than 15m. in height. Marginal distances shall be increased by 1m.for buildings having height 15m. and more but less than 24m. For buildings having height 24m. and more, marginal distances shall be as per regulations of non-congested area.
6.1.2 Other buildings like Public/ Semi-Public, Educational, Medical, Institutional, Commercial, Mercantile, etc.
(a) Floor Space Index, – The FSI permissible for these buildings shall be as per Regulation No.6.1.1.
(b) Marginal Distances - For these buildings marginal distances shall be 3m. on all sides including front up to 24m. height.
Provided that for building more than 24 m. height, regulations of non-congested area shall apply.
Provided further that, for buildings like cinema theatres, multiplex, assembly buildings, shopping malls etc., regulations for outside congested area, except FSI, shall apply.
6.1.3 Pathway for access to internal building or interior part of the building shall not be less than 3.6 m. in width.
6.1.4 Front setback (marginal distance) as prescribed under highway or any other rules shall be applicable if they are over and above as prescribed in these regulations.
6.2Regulations for Outside Congested Area (non-congested Area).
6.2.1 Marginal Distances and set-back for Residential Buildings and mixed use with Height up to 15 m. or as mentioned in the Table No. 6-D.
The provisions for minimum marginal distances as given in Table No. 6-D below shall apply for the Residential buildings, Residential with mixed uses permissible in Residential Zone and Residential buildings permissible in other zones.
Table No.6-D
Table No.6-D
Table No.6-D
Table No.6-D
Table No.6-D
Table No.6-D
Table No.6-D
Table No.6-D
Sr. No
Description of the road
Min Plot Size in Sq.m.
Min width of plot in meters
Min setback from road side in meters
Min. side margins in meters
Min. rear margi ns in meters
Remarks
1
2
3
4
5
6
7
8
1
Roads of width 30 m. and above in local authority area.
450
15
6.0in case of A, B, C class Municipal Corporations and 4.50 in case of other areas.
3.0
3.0
Side and Rear Margins for building upto 15m. height (excluding parking floor upto 6m. height)
2
In case of Regional Plan area. NH/SH
450
15
4.5m.or as specified by Highway rules whichever is more.
3.0
3.0
Side and Rear Margins for building upto 15m. height (excluding parking floor upto 6m. height)
3
Roads of width 18 m. and above but below 30 m.
250
10
4.5
2.0
2.0
Side and Rear Margins for building upto 10m. height (excluding parking floor upto 6m. height)
4
Roads of width 15 m. and above but below 18m.
200
10
3.0
1.5
1.5
Margins for buildings G+2 or stilt +3 structure
5
Roads of width less than 15m.
80
6
3.0
1.5(in case of semi-detached building, only one side marginal distance shall be permissible
1.5
Margins for buildings G+2 or stilt+ 3structure
6
Row Housing on roads of 12m. and below
30
3.5
2.25
0.0(In case of corner plot, 1.50 or building line of adjoining road whichever is more)
1.5
--do--
7
Row Housing for EWS/ LIG/ by public authority / private individual / Slum Upgradation etc. by public authority
20
3.0
0.9 from pathway or 2.25 from road boundary
0.0(In case of corner plot, 1.5 or building line of adjoining road whichever is more)
0.9
G+1 or stilt+ 2structure only
Notes:-
(1) The width of the road in above table shall govern the requirements in column 3 to 8.
(2) In case of Sr. No. 1 to 6 structures having higher height may be permitted subject to marginal distance mentioned in Regulation No.6.2.3.
(3) The minimum area of plots fronting on service roads along highways shall be with reference to the actual width of the service road.
(4) For semi-detached buildings, side margin shall be on one side only. Plots for semi-detached buildings shall be in pairs.
(5) Row-housing plots at the junction of two roads shall be larger to maintain the setback from both roads. Not more than 12 and not less than 3 plots shall be allowed in each block of row housing. Each block shall be separated from the other by a 4.5 m. wide road / pathway
or 4.5m. side marginal distance within the plot or space including side marginal distance of the plot.
(6) No garage shall be permitted in a building having stilt or basement provided for parking.
(7) Construction of ottas, railings, barricades or supporting columns for canopy or porch shall not be allowed in minimum front marginal distances. However, steps may be permitted within 1.2m. from the building line. Also supporting columns for canopy or porch may be allowed within building line.
(8) In case of Regional Plan areas, ribbon development rules shall not be relaxed without consent of the Highway Authority.
(9) In case of special building, marginal distances shall be as per regulations for such buildings.
(10) The plot width to depth ratio shall be 1:1.5 to 1:2.5, as far as possible in plotted layout.
(11) In Public Housing Schemes for E.W.S. undertaken by government or semi-government organizations, marginal distances shall be as per the respective schemes and rules.
(12) The front setback set-out in already approved and partially developed layouts/ schemes, may be retained as per original approval, so as to maintain the building line.
(13) The pattern of development like semi-detached, row housing etc. in already approved layout shall be as per said approved layout.
(14) Where commencement certificate is granted prior to publication of draft development plan or sanction of Development Plan and the plot gets affected by new road / road widening, proposed in the development plan, the front margin shall stand relaxed to that extent.
(15) In case of redevelopment proposal affected by line of street up to 9 m. width under Municipal Council or Municipal Corporation Act or development plan road of up to 9 m. width, the front margin shall stand relaxed to the extent of land affected by such proposal (1) subject to minimum setback of 1.0 m. for roads having width 12.0 m. or less and 2.0 m. for roads having width more than 12.0 m., from the final line of the street.
(16) Subsidiary structure such as garage (limited to one), outhouse and independent sanitary block may be permitted only in plots having area 250sq.m.or more.
(17) Rear or side marginal distances for development along nallah or watercourses shall be subject to Regulation regarding ―Sites Not Eligible for Construction of Building‖ and ―Construction Within Flood Line‖.(Chapter 3)
(18) The plots which are substandard in area shall be developed as per marginal distances mentioned in the above table with reference to road width.
118
(19) In case of plots having approach by dead-end road, (point access) front margin shall be limited to width of point access.
(2) (20) Building Line along classified roads as mentioned in regulation no.3.1.6 shall be applicable for residential buildings defined in Regulation No.1.3.93 (i) and Control Line along classified roads shall be applicable for other uses or for commercial uses as mentioned in regulation no.3.1.6 or for mixed use buildings where non-residential uses are proposed at least 50 % or more of total proposed built-up area.
(1) Inserted Vide Corrigendum / Addendum No.CR 79/2021, dt. 02nd December 2021.