The Provision in respect of minimum road width, minimum marginal distances etc., as given in Table No.6E below shall apply for different categories of other buildings.
| Table No.6 E | Table No.6 E | Table No.6 E | Table No.6 E | Table No.6 E |
| Sr. No | Type of building | Minimum road width required | Minimum marginal distances | Other stipulations |
| 1 | 2 | 3 | 4 | 5 |
| 1 | Medical buildings | Medical buildings | Medical buildings | Medical buildings |
| a) Hospital, Maternity Homes, Health Club, Clinics etc. buildings not being special buildings | 9 m. in case of A, B, C class Municipal Corporation, Metropolitan Authority Area and 7.5 m. in case of other areas. | Margins as per Table No. 6 D subject to side marginal distance of minimum3m. | NIL | |
| b) Hospital, Maternity Homes, Health Club etc. buildings under category of special building. | Road width as required for Special Buildings. (RegulationNo.3.3.9) | 6 m. on all sides | Height of building subject to provisions of Maharashtra Fire Prevention and Life Safety Measures Act 2006. | |
| 2. | Educational buildings | Educational buildings | Educational buildings | Educational buildings |
| a) Pre-primary School | On any road. | Margins as per Table No. 6 D | Other requirements shall be as mentioned in the Table No.7A of Regulation No. 7.1. Height of building subject to provisions of Maharashtra Fire Prevention and Life Safety Measures Act 2006. | |
| b) Primary School not being special building. | 6 m. | --do-- | Other requirements shall be as mentioned in the Table No.7A of Regulation No. 7.1. Height of building subject to provisions of Maharashtra Fire Prevention and Life Safety Measures Act 2006. | |
| c) Other Educational Buildings not being special building. | 9 m. | 3 m. on all sides | Other requirements shall be as mentioned in the Table No.7A of Regulation No. 7.1. Height of building subject to provisions of Maharashtra Fire Prevention and Life Safety Measures Act 2006. | |
| d) Any building of category a, b, c above being special building. | Road width as required for Special Buildings | 6 m. on all sides | Other requirements shall be as mentioned in the Table No.7A of Regulation No. 7.1. Height of building subject to provisions of Maharashtra Fire Prevention and Life Safety Measures Act 2006. | |
| 3. | Public-Semi Public Building | Public-Semi Public Building | Public-Semi Public Building | Public-Semi Public Building |
| a) Public-Semi Public Building not being special building. | 9 m. | Margins as per Table No.6D subject to side marginal distance of minimum 3 m | .-- | |
| a) Public-Semi Public Building being special building. | Road width as required for Special Buildings | 6 m. on all sides | -- | |
| 4. | Cinema Theatre | Cinema Theatre | Cinema Theatre | Cinema Theatre |
| Cinema Theatre/Drama Theatre/Assembly Hall/Multiplex /Shopping Malls | 12 m. | Front - 12m.(only on one major road).6m. on all remaining sides | i) In case of cities having population more than 2.5 lakhs as per latest census, redevelopment of existing cinema theatre on plots shall be allowed subject to the condition that at least 1/3rd of the existing seats shall be retained, which shall not be below 150 seats and may be developed in combination with user permissible in R2 zone.ii) For redevelopment of existing theatre, marginal distances including front margin as per these regulations shall not be insisted. Redevelopment shall be allowed as per existing set back distances. Parking area required as per these regulations shall not be insisted; however existing parking area shall be maintained.iii) In cases where redevelopment of existing Cinema Theatre is carried out on the same place with the capacity more than existing capacity in the form of single or multiscreen cinemas, then owner / developer shall be allowed FSI potential mentioned in column 6 or 9, as the case may be, of Table No.6-G at the rate of 20% land rate mentioned in Annual Rates of Statement without considering guidelines therein, for the additional capacity.iv) The existing Cinema Theatre shall be allowed to be relocated and constructed at some other place within a distance of 5 km. In such case, original site shall be allowed to be developed as per uses permissible in adjoining zone. Construction of Cinema Theatre / Multiplex shall conform to the provisions of Maharashtra Cinema (Regulations) Rules, 1966 and as amended from time to time, except the provisions mentioned above. | |
| v) For redevelopment of Cinema plot having area less than 1000 Sq.m., and if redevelopment of existing cinema theatre on such plot is not possible considering the other requirements in these regulations, the condition of providing atleast 1/3 of the existing seats or minimum 150 seats for cinema theatre shall not be insisted. In such case users permissible in adjoining predominant zone shall be permissible with special permission of sanctioning authority. | ||||
| 5. | Mangal Karyalaya | Mangal Karyalaya | Mangal Karyalaya | Mangal Karyalaya |
| a) Mangal karyalaya and like buildings not under the category of special building. | Road width as required for R-2 zone. | 3 m. on all sides. | - | |
| b) Mangal karyalaya and like buildings under the category of special building. | 12 m. | 6 m. on all sides. | - | |
| 6. | (#) Fuel Stations | (#) Fuel Stations | (#) Fuel Stations | (#) Fuel Stations |
| Fuel Filling Stations/including Petrol/ Ethanol /LPG / CNG /etc., Public Charging Stations for Electric Vehicles with or without service bays | 9 m. | 4.5m. on all sides | i) In case the plot is located on any Classified road in Regional Plan area, the distance from the junction of roads as may be specified by Indian Road Congress/ Ministry of Road, Transport and Highway, shall be followed. (IRC guideline 2009 and MORTH Letter No.RW/NH-33023/19/99- DOIII, Dated: 25.09.2003 as amended from time to time) ii) NOC from Chief Controller of Explosives shall be necessary. | |
| (#) Clarification issued vide letter No. CR 68/2021 dt., 10thMay, 2021. | (#) Clarification issued vide letter No. CR 68/2021 dt., 10thMay, 2021. | (#) Clarification issued vide letter No. CR 68/2021 dt., 10thMay, 2021. | (#) Clarification issued vide letter No. CR 68/2021 dt., 10thMay, 2021. | (#) Clarification issued vide letter No. CR 68/2021 dt., 10thMay, 2021. iii) In a plot of Fuel Filling Station, other building or composite building for sales office, snack bars, restaurant, public conveniences or like activities may be permitted. The FSI shall not exceed 0.25 and underground structures along with kiosks shall not be counted towards FSI. |
| 7. | Mercantile Buildings. | Mercantile Buildings. | Mercantile Buildings. | Mercantile Buildings. |
| a) Mercantile/ Business/ Hotel/ Commercial building under the category of special buildings. | Road width as required for Special Building. | Front 6m. Side & rear 6m. | i) Shops may also face on side and rear of a plot. ii) Minimum width and area of Shop shall be as per convenience of the owner / developer. iii) In case of construction of shops / offices only on ground floor (not being special building) side and rear marginal distance shall be as per Table No. 6-D. | |
| b) Mercantile/ Business/ Hotel/ Commercial building not under category of special buildings | Road width as required for R-2 zone. | Margins as per Table No. 6-D subject to side marginal distance of minimum3m. | i) Shops may also face on side and rear of a plot. ii) Minimum width and area of Shop shall be as per convenience of the owner / developer. iii) In case of construction of shops / offices only on ground floor (not being special building) side and rear marginal distance shall be as per Table No. 6-D. | |
| c) Convenience shopping in R-1 zone. | On any road. | Margins as per Table No. 6-D. | -- | |
| 8. | Stadium | Stadium | Stadium | Stadium |
| Stadium with Pavilion | 12m. | 6m. on all sides | The covered portion of spectator's gallery shall not exceed 25%of plot area, which shall not be counted towards FSI. Shops below spectator's gallery may be permitted which shall not be counted towards FSI. In addition to this, ancillary office, sportspersons accommodation, public convenience like structures may also be permitted which shall not consume more than 0.10 FSI on gross plot area. |
Note :
i) In case of plots fronting on National Highways, State Highways and Major District Roads in Regional Plan area, the building line shall be as per Ribbon Development Rules or as given in Table above, whichever is more.
ii) Side and rear marginal distances mentioned in above Table shall be subject to Regulation No.6.2.3, whichever is more.
iii) In case of special buildings, marginal distances shall be as per regulations for special buildings.
iv) A stadium should desirably accommodate 400 m. running track.
v) For above buildings, permissible FSI shall be as per Regulation No.6.3, unless otherwise specified above.
vi) Point access (approach by dead end road) to a plot shall be considered for the minimum road width requirement mentioned in above table. In such case, front margin shall be applicable for the width of point access road.
vi) The provisions about Cinema Theatre in column 5 of Table No. 6 E shall be applicable to Cinema Theatres in congested area also.