21.1 Applicability
The quality control and inspection shall apply to all high-rise residential building and all non-residential buildings.
The owner / developer / occupants and registered appointed Person on Record shall have to certify the inspection and safety report as per Schedule No. 3.
Page No 164
Schedules & Forms
Page No 165
Page No 166
| No. | Schedules |
|---|---|
| 1 | Minimum Qualification, Experience and Document Requirements for being considered for Registering with the Competent Authority as Persons on Record |
| 2 | Procedures for Ascertaining Whether a Person on Record has failed in Discharging his Responsibilities and Penalties |
| 3 | Technical Audit Report |
| 4 | Buildings requiring Fire Protection Consultant on Record and Inspection by Fire Officer |
| 5A | Fees and Charges for Grant of a Development Permission / Revised Development Permission / Revalidation of Development Permission |
| 5B | Fees and Charges for Grant of Occupancy Certificate / Change of Occupancy Certificate |
| 5C | Fees for Temporary Construction |
| 5D | Penalties |
| 6A | Drawings, Specifications and Documents to be Submitted with Application for Obtaining / Revising Development Permission for Building and for Sub- division & Amalgamation of Building Unit / Plot |
| 6B | Drawings, Specifications and Documents to be Submitted with Application for Obtaining / Revising / Revalidating Development Permission for Brick Kiln, Mining and Quarrying |
| 6C | Format for submission of Documents, Drawings and Specifications |
| 6D | Drawing, Specification and Documents to be Submitted with Application for Obtaining Permission for Temporary Construction |
| 7A | Information to be Displayed on Site |
| 7B | Documents and Drawings to be Maintained on Site During Period of Construction |
| 7C | Stages of Construction Work for which Notice for Progress of Construction to be Submitted to the Competent Authority |
| 8 | Inspection Requirements |
| 9 | Documents and Drawings to be Submitted along with the Application for Occupancy Certificate |
| 10 | Schedule for Maintenance and Inspection for Structural Stability and Fire Safety |
| 11 | Documents and Fees Required with Application for Advertising Display & Communication Infrastructures |
| 12 | List of Recommended Trees |
| 13 | Standalone Multi-Level Public Parking |
Page No 167
Page No 168
Forms:
| No. | Forms |
|---|---|
| 1 | Application for Registering as Person on Record |
| 2 | Certificate of Undertaking for Persons on Record |
| 3 | Notice to the Competent Authority of Non-Compliance of Building to Sanctioned Design and Specifications |
| 4 | Notice to the Competent Authority of Discontinuation as Person on Record |
| 5 | Notice of Cancellation of Development Permission |
| 6 | Notice to Stop Unauthorized Development |
| 7 | Direct Development Permission |
| 8 | Application for Registering Issue of Direct Development Permission |
| 9 | Registration or Cancellation of Direct Development Permission / Revised Direct Development Permission / Revalidated Direct Development Permission |
| 10A | Application for Development Permission for Building / Layout / Subdivision / Amalgamation |
| 10B | Application for Development Permission for Brick Kiln, Mining and Quarrying |
| 10C | Application for Development Permission for Temporary Construction |
| 11A | Area Statement for Buildings |
| 11B | Area Statement for Subdivision / Amalgamation / Layout of Land |
| 11C | Area Statement for Temporary Construction |
| 12 | Grant / Refusal of Development Permission / Revised Development Permission / Revalidated Development Permission |
| 13 | Application for Revised Direct Development Permission |
| 14 | Application for Registering Issue of Revised Direct Development Permission |
| 15 | Application for Revising Development Permission for Building / Layout / Sub - division / Amalgamation |
| 16 | Application for Revalidating Direct Development Permission / Revised Direct Development Permission |
| 17 | Application for Registering Revalidated Direct Development Permission / Revised Direct Development Permission |
| 18 | Application for Revalidating a Lapsed / Suspended Development Permission / Revised Development Permission |
| 19 | Notice for Commencement of Construction |
| 20 | Notice for Progress of Construction |
| 21 | Notice for Completion and Compliance Certification |
| 22A | Application for Occupancy Certificate |
Page No 169
Page No 170
Tables
| Table No. S1-1 | SEOR Qualification and Experience |
|---|---|
| Table No. S1-2 | COWOR Qualification and Experience |
| Table No. S1-3 | SOR Qualification and Experience |
| Table No. S2-1 | Penalties for Person on Record |
| Table No. S3-1 | Details of Technical Audit Report |
| Table No. S4-1 | (Deleted) |
| Table No. S5A-1 | Scrutiny Fees for Buildings |
| Table No. S5A-2 | Fees for Subdivision/ Amalgamation / Layout of Building Unit / Plot |
| Table No. S5A-3 | Charges for Change of Land Use |
| Table No. S5A-4 | Development Charges for Buildings |
| Table No. S5A-5 | Charges for Stacking Building Material on Public Roads |
| Table No. S5B-1 | Fees for Occupancy Certificate |
| Table No. S5B-2 | Fees for Change of Occupancy |
| Table No. S5C-1 | Fees for Applying for Temporary Construction |
| Table No. S5D-1 | Penalties for Unauthorized Construction and Occupancy |
| Table No. S5D-2 | Penalties Applicable for Regularizing Unauthorised Construction for Residential Use |
| Table No. S6C-1 | Drawing Sizes |
| Table No. S6C-2 | Colours and Notations for Drawings and Documents |
| Table No. S8A-1 | Principles of Risk Categorization (Definition of Consequence Class) and Inspection Requirements |
| Table No. S12-1 | List of Trees |
| Table No. F10A-1 | Information Sheet with Application for Development Permission for Building / Layout / Amalgamation/ Subdivision |
| Table No. F10B-1 | Application for Development Permission for Brick Kiln, Mining and Quarrying |
| Table No. F10C-1 | Information Sheet with Application for Development Permission for Temporary Construction |
| Table No. F11A-1 | Area Statement for Buildings |
| Table No. F11B-1 | Area Statement for Subdivision / Amalgamation / Layout of Land |
| Table No. F11C-1 | Area Statement for Temporary Construction |
| Table No. F26-1 | Details of Structural Inspection Report (Part 1) |
| Table No. F26-2 | Details of Structural Inspection Report (Part 2) |
| Table No. F26-3 |
Page No 171
Page No 172
Schedule
Page No 173
Minimum Qualification, Experience and Document Requirements for being considered for Registering with the Competent Authority as Persons on Record
(Refer Rule No. 3.2.1, 3.2.2, 3.2.3)
The procedure for registering persons with the Competent Authority is given in Rule No. 3.2.1. The registration shall be renewed annually. The following are the minimum qualifications and experience requirements for all persons to be considered for registering with the Competent Authority as Persons on Record, in order to determine their competence to fulfil their responsibilities as specified in Rule No. 3.2.2.
Minimum qualifications and experience requirements for architects, for being considered for registration with the Competent Authority, as Architects on Record shall be as follows:
(a) Architect must hold a valid registration with the Council of Architecture, India, issued as per the provisions of the Architects Act, 1972 or Bachelor’s Degree in Architecture / Diploma in Architecture Equivalent to B. Arch; and
(b) Architect must have a minimum of two years of experience in practice of architecture.
B Scope Work and Competence:
(a) Preparation & planning of all types of layouts; submission of drawings; submission of certificate of supervision, progress reports and submission of certificate of completion for all types of buildings in accordance with the provisions of these building Rules.
(b) Supervision & execution of construction work as per specifications & drawings prepared by authorised registered structural designer & engineer.
Minimum qualifications and experience requirements for engineers, for being considered for registration with the Competent Authority, as Engineers on Record shall be as follows:
(a) Master’s Degree in Civil Engineering, a bachelor’s degree in Civil Engineering or Building construction or its equivalent qualification recognized by the All-India Board of Technical Education, or, a Diploma in Civil Engineering or Diploma in Building Construction recognized by State Board of Technical Examination of any State of India or Associate Membership (Civil Engineering) of the Institute of Engineers, India (AMIE), and
(b) Engineer having bachelor’s degree, or its equivalent qualification must have minimum of two years of experience and Diploma holder/or AMIE must have minimum of five years of experience in professional work.
(a) Preparation & planning of all types of layouts except special structures / special buildings as per these Rules; submission of drawings and submission of certificate of supervision & completion for all types of buildings. A person having qualification of a Diploma in Civil Engineering shall be permitted to undertake low rise buildings only.
Page No 174
(b) Supervision & execution of construction work as per specifications & drawings prepared by authorized registered structural designer.
(c) He / she can prepare & submit structural details & calculations for buildings of load bearing structures.
Minimum qualifications and experience requirements for structural engineers, for being considered for registration with the Competent Authority as Structural Engineer on Record shall be as follows:
Table No. S1 – 1: SEOR Qualifications and Experience
| Grade | Scope of Work | Qualification | Minimum Years of Experience* |
| SEOR 1 | 1 Building with height above 25 m 2 Total proposed built-up area for a building unit is more than10000 sqm 3 Mercantile - 2, 3; Educational -1, 2, 3; Assembly - 1, 2, 3; Health - 2, 3, 4; Hospitality - 2, 3, Utility; Public Office; Special Buildings | Category 1 | 10 |
| Category 2 | 3 | ||
| SEOR 2 | 1 Building with height above 15 m /17.5 m (with Stilt) and up to 25 m 2 Total proposed built-up area for a building unit is more than 2000 sqm and up to 10000 sqm | Category 1 | 5 |
| Category 2 | 2 | ||
| SEOR 3 | 1 Building with height up to 15 m /17.5 m (with Stilt). 2 Total proposed built-up area for building unit up to 2000 sqm | Category 1 | 2 |
| Category 2 | ----- | ||
| Notes: 1 *Minimum years of experience of preparing structural design, detailed drawings, and specifications after attaining the degree/ Diploma. 2 Category 1: B.E/ B. Tech Civil or equivalent degree recognized by the AICTE. 3 Category 2: M.E/ M. Tech Civil, or a Ph. D in Structural Engineering. 4 Person holding Higher grade license can also work for Lower Grade Work | |||
Minimum qualifications and experience requirements for construction engineers, for being considered for registration with the Competent Authority as Clerk of Works on Record qualified for certifying the construction of buildings shall be as follows:
Table No. S1 – 2: COWOR Qualifications and Experience
| Grade | Scope of Work | Qualification | Minimum Years of Experience* |
| COWOR 1 | 1 Building with height above 25 m 2 Total proposed built-up area for a building unit is | Category 1 | 3 |
| Category 2 | 5 |
Page No 175
| Grade | Scope of Work | Qualification | Minimum Years of Experience* |
| more than 10000 sqm. 3 Mercantile - 2, 3; Educational -1, 2, 3; Assembly - 1, 2, 3; Health - 2, 3, 4; Hospitality - 2, 3; Utility; Public Office; Special Buildings | Category 3 | 3 | |
| COWOR 2 | 1 Building with height above 15 m /17.5 m (with Stilt) and up to 25 m. 2 Total proposed built-up area for a building unit is more than 2000 sqm and up to 10000 sqm. | Category 1 | 2 |
| Category 2 | 4 | ||
| Category 3 | 2 | ||
| COWOR 3 | 1 Building with height up to 15 m /17.5 m (with Stilt). 2 Total proposed built-up area for building-unit up to 2000 sqm | Category 1 | 1 |
| Category 2 | 2 | ||
| Category 3 | 1 | ||
| Notes: 1 *Minimum years of experience (after attaining the degree/ Diploma) in Construction work at a responsible position in any organization 2 Category 1: A Degree in Civil Engineering / Architecture or Diploma in Architecture equivalent to degree Architecture, or its equivalent qualification recognized by All India Board of Technical Education 3 Category 2: Diploma in Civil Engineering recognized by State Board of Technical Examinations of any State in India 4 Category 3: Bachelor's Degree with specialized training in building in construction technology or Diploma in Building Construction Technology from a recognized institute. 5 Person holding Higher grade license can also work for Lower Grade Work | |||
Minimum qualifications and experience requirements for construction engineers, for being considered for registration with the Competent Authority as Supervisor of Works on Record qualified for certifying the construction of buildings shall be as follows:
Table No. S1 – 3: SOR Qualifications and Experience
| Grade | Scope of Work | Qualification | Minimum Years of Experience* |
| SOR 1 | 1 Building with height above 25 m 2 Total proposed built-up area for a building unit is more than 10000 sqm 3 Mercantile - 2, 3; Educational -1, 2, 3; Assembly - 1, 2, 3; Health - 2, 3, 4; Hospitality - 2, 3; Utility; Public Office; Special Buildings | Category 1 | 3 |
| Category 2 | 5 | ||
| Category 3 | 3 | ||
| SOR 2 | 1 Building with height above 15 m /17.5 (with Stilt) m and up to 25 m 2 Total proposed built-up area for a building unit is more than 2000 sqm and up to 10000 sqm | Category 1 | 2 |
| Category 2 | 4 | ||
| Category 3 | 2 | ||
| SOR 3 | 1 Building with height up to 15 m /17.5 (with Stilt) m 2 Total proposed built-up area for building-unit up to 2000 | Category 1 | 1 |
| Category 2 | 2 |
Page No 176
| Grade | Scope of Work | Qualification | Minimum Years of Experience* |
| sqm | Category 3 | 1 | |
| SOR 4 | 1 Building with height up to 10 m 2 Total proposed built-up area for building-unit up to 200 sq m | Category 1 | 0 |
| Category 2 | 1 | ||
| Note: 1 *Minimum years of experience (after attaining the degree/ Diploma) in Construction work at a responsible position in any organization 2 Category 1: A Degree in Civil Engineering / Architecture or Diploma in Architecture equivalent to degree Architecture, or its equivalent qualification recognized by All India Board of Technical Education 3 Category 2: Diploma in Civil Engineering recognized by State Board of Technical Examinations of any State in India 4 Category 3: Bachelor's Degree with specialized training in building in construction technology or Diploma in Building Construction Technology from a recognized institute. 5 Person holding Higher grade license can also work for Lower Grade Work | |||
Fees and Charges for Grant of a Development Permission / Revised Development Permission / Revalidation of Development Permission
(Refer Rule No. 4.10.2, 4.11.2, 4.12.2, 4.13.2, 4.14.2, 4.15.2, 5.3, 5.4.1, 6.6.2)
A person applying for a Development Permission / Revised Development Permission / Revalidation of Permission shall have to pay the following Fees and Charges along with the application to the Competent Authority at the following rates:
The fees shall be paid for both – Direct Development Permission and Development Permission. The scrutiny fees shall be levied at the time of making an application for Development Permission.
Table No. S5A – 1: Scrutiny Fees for Building
| No | Type of Use | Rate per sq m of Built-Up Area (Subject to minimum fees of Rs. 1000/-) | |
| Building upto 15m height | Building more than 15m height | ||
| 1 | Residential | Rs. 5.00 | Rs. 10.00 |
| 2 | Commercial | Rs. 8.00 | Rs. 13.00 |
| 3 | Residential Cum Commercial | Rs. 6.00 | Rs. 11.00 |
| 4 | Industrial | Rs. 7.00 | Rs. 12.00 |
| 5 | Public Offices, Utilities | Rs. 4.00 | Rs. 9.00 |
| 6 | Others | Rs. 5.00 | Rs. 10.00 |
(*others: includes Health, Education, etc. and other than the above-mentioned type of land use)
• In case of a revised development permission, these shall be paid again.
In case of revalidation of lapsed / suspended development permission, these shall not be paid again, only a revalidation fee will be paid which will be 25% of the Scrutiny Fee already paid.
In case of cancellation of development permission, these shall be forfeited.
A One-time payment shall be made for approval of subdivision / amalgamation / layout of land. It shall be valid for a period of 5 years.
Table No. S5A – 2: Fees for Subdivision /Amalgamation / Layout of Building Unit / Plot
| No | Type of land Use | Rate per sq m of land (Subject to minimum fees of Rs. 1000/-) | |
| Amalgamation | Subdivision / Layout of Building Unit / Plot | ||
| 1 | Residential | Rs. 3.00 | Rs. 6.00 |
| 2 | Commercial | Rs. 4.00 | Rs. 8.00 |
| 3 | Residential Cum Commercial | Rs. 3.50 | Rs. 7.00 |
| 4 | Industrial | Rs. 5.00 | Rs. 10.00 |
| 5 | Public Offices, Utilities | Rs. 3.00 | Rs. 6.00 |
| 6 | Others | Rs. 4.00 | Rs. 8.00 |
(*others: includes Health, Education, etc. and other than the above-mentioned type of land use)
Page No 186
In case of a revised development permission, these shall be paid again.
In case of revalidation of lapsed / suspended development permission, these shall not be paid again, only a revalidation fee will be paid which will be 25% of the Scrutiny Fee already paid.
In case of cancellation of development permission, it shall be forfeited.
Mining, quarrying and brick kiln with or without chimney and processing of lime, sagol etc. without construction‐ Rs.1,00,000 per 0.1 hectare or part thereof.
• In case of a revised development permission, these shall be paid again.
In case of revalidation of lapsed / suspended development permission, these shall not be paid again, only a revalidation fee will be paid which will be 25% of the Scrutiny Fee already paid.
In case of cancellation of development permission, it shall be forfeited.
Charges for change in land use shall be paid every time there is a change of use of land.
Page No 187
Table No. S5A – 3: Charges for Change of Land Use
| No | Type of land Use | Rate per sq m of land (Subject to minimum fees of Rs. 1000/-) |
|---|---|---|
| 1 | Residential | Rs. 25.00 |
| 2 | Commercial | Rs. 40.00 |
| 3 | Residential Cum Commercial | Rs. 40.00 |
| 4 | Industrial | Rs. 50.00 |
| 5 | Public Offices, Utilities | Rs. 10.00 |
| 6 | Others | Rs. 40.00 |
(*others: includes Health, Education, etc. and other than the above-mentioned type of land use)
The Development Charges for infrastructure shall be paid for both – Direct Development Permission and Development Permission.
The development charges for infrastructure shall be levied at the time of making an application for Development Permission.
Table No. S5A – 4: Development Charges for Buildings
| No | Type of land Use | Rate per sq m of Built up (Subject to minimum fees of Rs. 1000/-) |
|---|---|---|
| 1 | Residential | Rs. 50.00 |
| 2 | Commercial | Rs. 80.00 |
| 3 | Residential Cum Commercial | Rs. 80.00 |
| 4 | Industrial | Rs. 100.00 |
| 5 | Public Offices, Utilities | Rs. 20.00 |
| 6 | Others | Rs. 80.00 |
(*others: includes Health, Education, etc. and other than the above-mentioned type of land use)
• In case of a revision of development permission, the differential shall be paid.
• In case of revalidation of lapsed / suspended development permission, these shall not be paid again.
In case of cancellation of development permission, it shall be forfeited.
Stacking Charges shall be levied during grant of commencement certificate and charges will be taken per week.
Table No. S5A – 5: Charges for Stacking Building Material on Public Roads
Other Charges / Fees shall be levied under the provisions of other Act and or instructed by Government.
Note: All Charges and Fees may be revised by MS PDA from time to time.
Page No 188
Fees and Charges for Grant of Occupancy Certificate / Change of Occupancy Certificate
(Refer Rule No. 6.5.2)
A person applying for an Occupancy Certificate shall have to pay Fees along with the application to the Competent Authority at the following rates:
Table No. S5B – 1: Fees for Occupancy Certificate
| No. | Description | Fees equal to |
|---|---|---|
| (1) | (2) | (3) |
| 1 | If the Occupancy is in conformity with these Rules and no change from the permission granted. | 10% of the Development Permission Scrutiny Fees that is leviable on the building unit, as the case may be |
If the development use is in conformity with the General Development Rules but there is change of use, then a fee equal to two times of the Scrutiny Fees paid shall be paid. The Development Charges as per the new proposed use shall be paid – the earlier shall be forfeited.
Table No. S5B – 2: Fees for Change of Occupancy
| No. | Description | Fees equal to |
|---|---|---|
| (1) | (2) | (3) |
| 1 | In conformity with these Rules but with internal modification without any change in overall location and/or overall dimension or margins of the building. | Two times of the Development Permission Scrutiny Fees that is leviable on the building unit, as the case may be. |
Page No 189
(Refer Rule No. 4.4.4, 4.6, 4.7.2, 4.10.4, 4.11.4, 4.12.4, 4.13.4, 4.14.4, 4.15.4, 4.16.4, 6.5.4, 6.6.4)
Table No. S5D – 1: Penalties for Unauthorised Construction and Occupancy
| No. | Type | Penalty (Rs/ Sq m) | Remarks | |
| 1 | Construction / Occupancy started / completed before applying for permission. | Applicable to total proposed built up area or total occupied or constructed area, whichever is higher. | ||
| 1.1 | For Residential | 300 | ||
| 1.2 | For Commercial | 500 | ||
| 1.3 | For Industrial | 800 | ||
| 1.4 | For Others use | 600 | ||
| 2 | Construction / Occupancy started / completed before granting permission but had applied for permission. | Applicable to total proposed built up area or total occupied or constructed area, whichever is higher | ||
| 1.1 | For Residential | 200 | ||
| 1.2 | For Commercial | 300 | ||
| 1.3 | For Industrial | 500 | ||
| 1.4 | For Others use | 400 | ||
| 3 | Minor Deviation from the approved construction plan, but within these Rules. | Twice the scrutiny fees | Deviation in this respect would be only for minor alteration within the approved building plan without deviation in approved built up area | |
B Other Penalites
Lift auditor shall provide certificate at interval not more than 2 years that the lifts and escalator in the building are kept in good working condition. For not doing so penalties will be levied as decided by Competent Authority.
In cases where misuse of parking space is noticed, the use of the entire building shall be discontinued by the Competent Authority. Building use shall be permitted only after the required parking spaces are provided. High penalty shall be levied considering the period of misuse of the parking space and the benefit derived out of misuse as decided by the Competent Authority from time to time.
Page No 191
(Refer Rule No. 4.16.2)
Table No. S5C – 1: Fees for Applying for Temporary Construction
| No. | Type of Temporary Construction | Rate per sq m of land (Subject to minimum fees of Rs. 1000/-) | |
| 1 | Pandals for fair, ceremonies, religious functions or for vendors | Rs 100 | |
| 2 | Temporary Monsoon Shed of bamboo (May to September) | Rs 75 | |
| 3 | Temporary construction like tent city, camping ground or base camp. | Rs 500 | |
| 4 | a) | Structures of exhibitions/ circuses etc | Rs 100 |
| b) | Structures for ancillary works for quarrying operations in conforming zones. | ||
| c) | Government booths and temporary shelters. | ||
| d) | Transit accommodation for persons to be rehabilitated in a new construction. | ||
| e) | Structures for educational and medical facilities within the site of the proposed building during the phase of planning and constructing the said permanent buildings. | ||
| f) | Ready mix concrete plant. | ||
Equal amounts of fees shall be payable as deposit, which will be refundable provided by end of the stipulated period, such temporary structures are removed without fail by the owner / applicant.
Failure to remove such temporary sheds will be liable for forfeiture of the deposit and any such failure continuing beyond the said period shall be liable for imposition of penalty which will, be three times the rate of 100/ per sq m per week.
Page No 190
Drawings, Specifications and Documents to be Submitted with Application for Obtaining Revising Development Permission for Building and for Sub- division & Amalgamation of Building Unit / Plot
(Refer Regulation No. 4.10.1, 4.11.1, 4.12.1, 4.13.1, 4.14.1, 4.15.1)
The owner / developer shall submit to the Competent Authority the following documents, drawings, and specifications along with application for obtaining and revising a development permission. These are common documents for obtaining / revising development permission for buildings and for subdivision & amalgamation of building unit / plot.
1 Five copies of all plans and statements shall be made available along with the notice. Soft copy of the drawings in cad format shall also be submitted.
2 All documents, drawings, and specifications to be submitted along with the notice shall be duly signed by the Owner and the appropriate Person on Record and shall indicate their names, contact information and registration number.
3 Every drawing, document and report shall be signed by the Owner and the Architect on Record or Civil Engineer on Record, the Structural Engineer on Record, and the Clerk of Works on Record as the case may be and in accordance with the General Development Rules.
Satisfactory documentary legal evidence of the Right to Develop or Build on the Building Unit, including original copies of the relevant extract from the Property Register for City Survey Lands or Record of Rights for Revenue Lands as applicable.
2 Certified copies of approved sub‐divisions or layout of the final plot from the concerned Authority as the case may be showing:
a City Survey No. or Revenue No.
b Area and measurements of the building unit. Authority may dispense with this requirement in the cases where it is satisfied regarding the ownership of land on the basis of any documentary evidence or proof produced by the applicant.
3 Copy of Sanctioned Layout including date of sanction and Reference No.
4 Certified part plan and zoning certificate from the Authority.
5 Form No 10A/13: Application for obtaining / revising a development permission.
6 Form No. 2: Certificate of Undertaking by the Persons on Record or Engineer on Record as applicable.
7 Form No. 11A: Area Statement for Buildings or Form No. 11B: Area Statement for Sub- division and Amalgamation or Form No. 11C: Area Statement for Temporary Construction (whichever is applicable)
8 NOC from Appropriate Authority as per Rules as applicable.
9 Calculation statement for payment of all relevant Development Permission Fees / Charges or any other charges.
10 Photographic Identity Proof of Owner or Developer and person on records.
11 Photograph of Building Unit
12 Certificate, NOC, opinions as may be required by Competent Authority.
13 In case of application for buildings, in addition to above, the following shall be submitted:
a) Soil Test Report for buildings with more than 3 floors or frame structures.
b) Form No. 2: Certificate of Undertaking by the Structural Engineer on Record.
c) Form No. 2: Certificate of Undertaking by the Clerk of Works on Record.
d) Form No. 2: Certificate of Undertaking by the FPCOR, if applicable.
e) Form No. 2: Certificate undertaking for Hazard Safety
Page No 192
1 Key Plan for both Building Plan and Sub-division & Amalgamation shall be as under:
a) Minimum Scale: 1:8000 and
b) The plan should explain the boundary and location of the site with respect to neighbourhood landmarks.
2 Site Plan for buildings shall be drawn as under:
a) Minimum Scale: 1:500 for plots less than 100 hectares and 1:1000 for others.
b) Boundaries of the plot and of any contiguous plots belonging to the owner.
c) Position of the building unit / plot in relation to the neighbouring streets and street names.
d) Direction of north point relative to the plan of buildings.
e) Building unit level in relation to the neighbouring street level.
f) Building unit number or plot number of the plot on which the building is intended to be erected.
g) All existing buildings standing on, over or under the building unit / plot.
h) Any existing natural or manmade physical features, such as wells, drains, trees, high tension line, gas pipeline, railway line, etc.
i) Proposed use of every building.
j) The position of building(s) and construction which the applicant intends to erect in relation to:
i The boundaries of the plot and in case where the plot has been partitioned, the boundaries of the portion owned by the applicant and also of the portions owned by others.
ii All buildings (with number of storeys and height) and premises adjacent to the plot and of the contiguous land, if any, referred to in (a), and.
iii Any street prescribed under the Act and passing through the building unit/s clearly indicating the regular line of streets.
iv The area within the regular line of the street not to be built upon but to be added to the street, hatched in green together with its measurements.
v Building lines and margins of streets.
k) The width and level of the street in front, and of the street, if any, at the side or rear of building clearly indicating the regular line of streets.
l) The means of access from the street to the site and all existing and proposed buildings.
m) Open space to be left around the building to secure free circulation of air, admission of light and access.
n) Open space to be provided under these rules.
o) The area of the whole plot and the break‐up of Total built‐up area on each floor
p) Area classified for exemption of built-up area calculations.
q) Dimensions and areas of common plot, as required under these rules,
r) Parking layout, indicating the parking spaces, access lane, driveway, or ramp.
s) Layout and details of rainwater harvesting required under the Development Rules, if any.
The position of every water closet, privy, urinal, bathrooms, cess pool, well or cistern in connection with the building other than those shown in the building plan.
1 Detailed Drawings shall be submitted showing the boundary walls and gates.
Minimum Scale: 1:100 for plots less than 500 sq m and 1:500 for others and shall contain the following:
a) Space for circulation and parking.
b) Paved pathways.
c) Existing trees.
d) Proposed tree plantation.
e) Green areas.
f) Unpaved areas.
The plans, elevations and sections of the proposed building shall be drawn to a scale of 1:100 showing the following details, wherever applicable:
a) All floor plans together with the covered area, size and spacing of framing members, size of rooms and the position and width of staircases, ramps and other exit ways, lift wells, lift machine room and lift pit details.
b) Built‐up area of each dwelling unit, or shop or office space at every floor level.
c) Use or occupancy of all parts of the building.
d) Exact location of essential services, like WC, sink, bathroom, kitchen, cesspool, water tank, cistern, etc.
e) Section drawings clearly showing the size of the footings, thickness of basement wall, wall construction, sizes and spacing of structural members, floor slabs and roof slabs with their materials. The section shall indicate the heights of building and rooms and also the height of the parapet, and the drainage and the slope of the roof. At least one section should be taken through the staircase. Access to the various parts of the building and its appurtenances also should be shown in one section.
f) Levels of the site and all floors in relation to the datum or crown level of the access street.
g) All elevations.
h) Details of service privy, if any.
i) Dimensions of the projected portions beyond the permissible building line.
j) Terrace plan including cabin structure.
k) Parking spaces provided and the parking layout.
l) Direction of north point relative to the plan of buildings.
Page No 194
m) Such other particulars as may be required to explain the proposed building clearly.
4 Additional Fire Prevention and Safety Provisions:
Additional fire prevention and safety provisions to be provided in buildings eligible for a Development Permission are specified in Schedule No.4 according to different uses and the height of the building. Details of these shall be indicated in the drawings as required.
5 Services Plans:
The outside service pipe for sewerage that is to say from where will they connect with sewerage line if and when sewerage will be provided and from where the rain water coming from back of the plot shall go and to which drain shall be shown. The buildings shall be required to have adequate amount of soak pit and septic tank.
1 Detailed drawing shall be submitted showing the boundary walls and gates.
2 Landscape plan
a The space for circulation and parking;
Page No 195
b Paved pathways.
Existing trees.
d Proposed tree plantation.
e Green areas.
Receipt of development permission fees and charges paid as per Schedule No. 5A and of other charges leviable on the building unit shall be attached with the application.
Drawings, Specifications and Documents to be Submitted with Application for Obtaining Revising / Revalidating Development Permission for Brick Kiln, Mining and Quarrying
(Refer Rule No. 4.11.1, 4.13.1, 4.15.1)
The owner / developer shall submit to the Competent Authority the following documents, drawings, and specifications along with application for obtaining and revising a development permission.
Every drawing, document and report shall be signed by the owner and the Clerk of Works on Record as the case may be and in accordance with these rules.
An extract of the record of rights or any other document showing the ownership of the land for this purpose. If the applicant is not the owner of the land, necessary documentary proof shall be provided.
2 Zoning Certificate from the Competent Authority
3 Form No. 10B: Application for Obtaining / Revising a Development Permission
4 True Copies of previous year’s development permission
5 Form No. 2: Certificate of Undertaking by the Architect on Record or Engineer on Record as applicable.
6 Form No. 2: Certificate of Undertaking by the Structural Engineer on Record, as applicable
7 Form No. 2: Certificate of Undertaking by the Clerk of Works on Record
8 NOC from Appropriate Authority as applicable.
9 Calculation statement for payment of all relevant development permission fees or any other charges.
10 Photographic identity proof of owner or developer.
1 A certified site plan showing the land in question along with surrounding area shall be attached.
2 Sketch site plan showing:
a Area of site presently used.
b Area of site proposed to be used.
Receipt of Development Permission Fees and Charges paid as per Schedule No. 5A and of other charges leviable on the plot shall be attached with the application.
Page No 196
(Refer Rule No. 4.10.1, 4.11.1, 4.12.1, 4.13.1, 4.14.1, 4.15.1, 4.16.1, 6.6.1)
1 Copies of Plan and Documents.
2 Submission of all documents, certificates, reports, and drawings to the Competent Authority: a Shall represent all facts accurately,
b Shall be as per formats and forms prescribed by the Competent Authority,
c Shall be neat, clean, and fully legible, and, on durable paper folded in the manner prescribed by the Competent Authority,
d Shall be free of any scratches or corrections – small, initiated corrections shall be permitted.
3 Standard sizes of all drawings and documents
Page No 197
All drawings and documents shall be of standard sizes as prescribed below:
Table No. S6C – 1: Drawing Sizes
| No | Standard Sizes | Trimmed Size (mm) |
|---|---|---|
| 1 | A0 | 841 X 1189 |
| 2 | A1 | 594 X 841 |
| 3 | A2 | 420 X 594 |
| 4 | A3 | 297 X 420 |
| 5 | A4 | 210 X 297 |
| 6 | A5 | 148 X 210 |
All drawings and documents shall follow standard colours and notations as prescribed below:
Table No. S6C – 2: Colours and Notations for Drawings and Documents
| No. | Item | Site Plan | Building Plan |
|---|---|---|---|
| 1 | Plot lines | Thick Black | Thick Black |
| 2 | Existing street | Green | |
| 3 | Future street, if any | Green dotted | |
| 4 | Permissible building line | Thick dotted Black | |
| 5 | Open spaces | No colour | No colour |
| 6 | Existing works | Blue | Blue |
| 7 | Work proposed to be demolished | Yellow hatched | Yellow hatched |
| 8 | Proposed work | Red | Red |
| 9 | Drainage and sewerage work | Red dotted | Red dotted |
| 10 | Water supply work | Black dotted thin | Black dotted thin |
| 11 | Work without permission if started on site | Grey | Grey |
| 12 | Approved work | Yellow | Yellow |
Drawings, Specifications and Documents to be Submitted with Application for Obtaining Permission for Temporary Construction
(Refer Regulation No. 4.10.1, 4.11.1, 4.12.1, 4.13.1, 4.14.1, 4.15.1, 4.16.1)
The owner / developer shall submit to the Competent Authority the following documents, drawings, and specifications along with application for obtaining and revising a development permission. These are common documents for obtaining permission for Temporary Construction.
1 Two copies of all plans and statements shall be made available along with the notice. Soft copy of the drawings in cad format shall also be submitted.
2 All documents, drawings, and specifications to be submitted along with the notice shall be duly signed by the Owner and the appropriate Person on Record and shall indicate their names, contact information and registration number.
3 Every drawing, document and report shall be signed by the Owner and the Architect on Record or Civil Engineer on Record, the Structural Engineer on Record, and the Clerk of Works on Record as the case may be and in accordance with the General Development Rules.
Satisfactory documentary legal evidence of the Right to Develop or Build Temporary Construction, including original copies of the relevant extract from the Property Register for City Survey Lands or Record of Rights for Revenue Lands as applicable.
2 If the applicant is not the owner of the land, necessary documentary proof shall be provided.
4 Certified part plan and zoning certificate from the Authority.
5 Form No 10A/13: Application for obtaining / revising a development permission.
6 Form No. 2: Certificate of Undertaking by the Persons on Record or Engineer on Record as applicable.
8 NOC from Appropriate Authority as per Rules as applicable.
9 Calculation statement for payment of all relevant Development Permission Fees / Charges or any other charges.
10 Photographic Identity Proof of Owner or Developer and person on records.
12 Certificate, NOC, opinions as may be required by Competent Authority.
13 In case of application for buildings, in addition to above, the following shall be submitted:
a Form No. 2: Certificate of Undertaking by the Structural Engineer on Record.
b Form No. 2: Certificate of Undertaking by the Clerk of Works on Record.
c Form No. 2: Certificate of Undertaking by the FPCOR, if applicable.
d Form No. 2: Certificate undertaking for Hazard Safety
1 Key Plan for temporary construction shall be as under:
a Minimum Scale: 1:8000 and
b The plan should explain the boundary and location of the site with respect to neighbourhood landmarks.
2 Site Plan for buildings shall be drawn as under:
Minimum Scale: 1:500 for plots less than 100 hectares and 1:1000 for others.
b Boundaries of the plot and of any contiguous plots belonging to the owner.
c Position of the building unit / plot in relation to the neighbouring streets and street names.
d Direction of north point relative to the plan of buildings.
e Building unit level in relation to the neighbouring street level.
f Building unit number or plot number of the plot on which the temporary construction is intended to be erected.
Page No 198
g Any existing natural or manmade physical features, such as wells, drains, trees, high tension line, gas pipeline, railway line, etc.
h Proposed use of temporary construction.
i The width and level of the street in front, and of the street, if any, at the side or rear of temporary construction clearly indicating the regular line of streets.
j The means of access from the street to the site and all existing and proposed temporary construction.
k Open space to be left around the temporary construction to secure free circulation of air, admission of light and access.
l Open space to be provided under these rules.
m The area of the whole plot and the break‐up of Total temporary construction area
Receipt of development permission fees and charges paid as per Schedule No. 5C and of other charges leviable on the building unit shall be attached with the application.
Page No 199
(Refer Rule No. 3.2.5)
1 Procedure for Ascertaining whether a Person on Record has failed to Discharge his Responsibility.
A four-member Professional Oversight Committee shall be established by the Union Territory / PDA to ascertain whether a Person on Record has failed to discharge his responsibilities.
The Professional Oversight Committee shall comprise of the following four members:
1 Chairman PDA
2 MS, PDA (respective)
3 Associate Town Planner of the PDA
4 Expert Architect / Engineer from the Private Sector
The Professional Oversight Committee shall undertake scrutiny of each case on an individual basis and shall provide at least one opportunity to the Person on Record under scrutiny to be heard. Its proceedings shall be recorded in writing.
The cost(s) incurred for conducting the scrutiny shall be borne by the PDA.
The Professional Oversight Committee shall ascertain whether the Professional on Record has failed in discharging his responsibilities and shall determine and administer penalties for the same.
Page No 178
Table No. S2 – 1: Penalties for Person on Record
| Violation of Reg. No.: | Financialpenalty<sup>1</sup> | Financialpenalty<sup>1</sup> | Financialpenalty<sup>1</sup> | Financial penalty<sup>1</sup> and delisting for 6 months | Delisting for 12 months and registration of complaint with professional body | Permanent delisting and prosecution<sup>1</sup> |
|---|---|---|---|---|---|---|
| Rule Nos. 4.4: Person on Record undertake construction on plot without revalidating a Lapsed Development Permission or when a Development Permission has been cancelled | 1<sup>st</sup> offence (Rs. 10,000) | 2<sup>nd</sup> offence (Rs.15,000) | 3<sup>rd</sup> offence (Rs.20,000) | 4<sup>th</sup> offence (Rs.25,000) | 5<sup>th</sup> offence (Rs.30,000) | |
| Rule No. 5.4: Negligence of Person on Record leading to structural failure of a building | 1<sup>st</sup> offence (Rs.50,000) | |||||
| Rule Nos. 4.10.1, 4.12.1 and 4.14.1: Architect on Record fails to register the Issue of Direct Development Permission / Revision of Direct Development Permission / Revalidation of Direct Development Permission with the Commissioner within the stipulated period | 1<sup>st</sup> offence (Rs. 10,000) | 2<sup>nd</sup> offence (Rs.15,000) | 3<sup>rd</sup> offence (Rs.20,000) | 4<sup>th</sup> offence (Rs.25,000) | 5<sup>th</sup> offence (Rs.30,000) | |
| Rule Nos. 4.10, 4.11, 4.12, 4.13, 4.14, 4.15, 4.16: Person on Record submits incomplete or inadequate drawings, document, and specifications along with application to register Issue of Direct Development Permission / Revision of Direct Development Permission / Revalidation of Direct Development Permission to the Commissioner | 1<sup>st</sup> offence (Rs. 10,000) | 2<sup>nd</sup> offence (Rs.15,000) | 3<sup>rd</sup> offence (Rs.20,000) | 4<sup>th</sup> offence (Rs.25,000) | 5<sup>th</sup> offence (Rs.30,000) | |
| Rule Nos. 4.10, 4.11, 4.12, 4.13, 4.14, 4.15, 4.16: Person on Record intentionally and fraudulently misrepresents or hides material facts from the Commissioner in the application to register issue of or grant of Development Permission / Revised Development Permission / Revalidation of Development Permission | 1<sup>st</sup> offence (Rs. 15,000) | 2<sup>nd</sup> offence (Rs.25,000) | 3<sup>rd</sup> offence (Rs.35,000) | |||
| Rule No. 5.2: Construction Engineer on Record fail to display necessary information on the Notice Board at site | 1<sup>st</sup> offence (Rs.10,000) | 2<sup>nd</sup> offence (Rs.15,000) | 3<sup>rd</sup> offence (Rs.20,000) | 4<sup>th</sup> offence (Rs.25,000) | 5<sup>th</sup> offence (Rs.30,000) |
1 Prosecution under section 140 (y) and 141 of the Dadra and Nagar Haveli and Daman and Diu Town & Country Planning Act, 1974
Page No 179
| Violation of Reg. No.: | Financialpenalty<sup>1</sup> | Financialpenalty<sup>1</sup> | Financialpenalty<sup>1</sup> | Financial penalty<sup>1</sup> and delisting for 6 months | Delisting for 12 months and registration of complaint with professional body | Permanent delisting and prosecution<sup>1</sup> |
|---|---|---|---|---|---|---|
| Rule No. 5.3: Construction Engineer on Record fails to maintain necessary drawings and documents at site during Period of Construction | 1<sup>st</sup> offence (Rs.10,000) | 2<sup>nd</sup> offence (Rs.15,000) | 3<sup>rd</sup> offence (Rs.20,000) | 4<sup>th</sup> offence (Rs.25,000) | 5<sup>th</sup> offence (Rs.30,000) | |
| Rule No. 5.4.1: Construction Engineer on Record stack, store or dispose building material on public space or street without obtaining Permit to Use Abutting Street for Construction | 1<sup>st</sup> offence (Rs.10,000) | 2<sup>nd</sup> offence (Rs.15,000) | 3<sup>rd</sup> offence (Rs.20,000) | 4<sup>th</sup> offence (Rs.25,000) | 5<sup>th</sup> offence (Rs.30,000) | |
| Rule No. 5.4.2: Construction Engineer on Record does not provide barricading or provides inadequate barricading of the plot during period of construction | 1<sup>st</sup> offence (Rs.10,000) | 2<sup>nd</sup> offence (Rs.15,000) | 3<sup>rd</sup> offence (Rs.20,000) | 4<sup>th</sup> offence (Rs.25,000) | 5<sup>th</sup> offence (Rs.30,000) | |
| Rule No. 5.4.3: Construction Engineer on Record causes or fails to prevent damage or inconvenience during construction | 1<sup>st</sup> offence (Rs.10,000) | 2<sup>nd</sup> offence (Rs.15,000) | 3<sup>rd</sup> offence (Rs.20,000) | 4<sup>th</sup> offence (Rs.25,000) | 5<sup>th</sup> offence (Rs.30,000) | |
| Rule Nos. 5.5.1: Architect on Record or Construction Engineer on Record fail to notify the Commissioner before commencing construction on the plot within the stipulated period | 1<sup>st</sup> offence (Rs. 15,000) | 2<sup>nd</sup> offence (Rs.20,000) | 3<sup>rd</sup> offence (Rs.25,000) | 4<sup>th</sup> offence (Rs.30,000) | 5<sup>th</sup> offence (Rs.40,000) | |
| Rule Nos. 5.5.3: Architect on Record and Construction Engineer on Record fail to notify the PDA of Progress of Construction, Compliance Certification and obtaining Permission to Proceed with Further Construction within the stipulated period | 1<sup>st</sup> offence (Rs. 15,000) | 2<sup>nd</sup> offence (Rs.20,000) | 3<sup>rd</sup> offence (Rs.25,000) | 4<sup>th</sup> offence (Rs.30,000) |
Page No 180
| Violation of Reg. No.: | Financialpenalty<sup>1</sup> | Financialpenalty<sup>1</sup> | Financialpenalty<sup>1</sup> | Financial penalty<sup>1</sup> and delisting for 6 months | Delisting for 12 months and registration of complaint with professional body | Permanent delisting and prosecution<sup>1</sup> |
|---|---|---|---|---|---|---|
| Development Use Permission or Permission to Change Sanctioned Use of Development | ||||||
| Rule Nos. 3.3.2: If there is any deviation from building sanction plan the AOR blacklisted for 10 years | 1<sup>st</sup> offence (Rs.50,000) | |||||
| Rule Nos. 5.1.4: Fire Protection Consultant on Record (FPCOR) shall inspect the building at intervals not more than 12 months to ascertain and certify to competent authority that the building's fire safety has not been compromised due to lack of adequate maintenance. For not doing so penalties will be taken | 1<sup>st</sup> offence (Rs.1,00,000) |
All financial penalties are to be decided by the Professional Oversight Committee of the PDA to ascertain whether a Person on Record has failed to discharge his responsibilities and to determine penalties for the same.
2 If the penalties imposed in the 1st offence are not complied with by the Person on Record within 1 month of the date of imposing the penalty, the penalty for 2nd offence shall apply and so forth.
3 If the penalties imposed in the 1st offence are not complied with by the Person on Record within 6 months of the date of imposing the penalty, the Person on Record shall be unregistered from the records of the PDA for 1 year and complaint filed with his professional body.
Page No 181
(Refer Rule No. 3.3)
Table No. S3 – 1: Details of Technical Audit Report
| 1 | Design | Comments | |
| 1.1 | Design / Drawings available? | Y/N | |
| 1.2 | Design Category | ||
| 1.2.1 | Type Design? | Y/N | |
| 1.2.2 | Specific Design | Design to be collected to refer to Design Consultant /H.O. | |
| 1.3 | Drawings prepared / checked by competent Authority? | Y/ N | |
| 1.3 | Design Drawing/ Details | Y/ N | |
| 1.5 | Structural details included | Y/ N | |
| 1.6 | Earthquake/cyclone resistant features Included? | Y/ N | |
| 1.7 | Design verified/vetted by Dept./Govt. approved agency/competent authority? | Y/N | |
| 1.8 | Design changes approved by Dept./Govt. approved agency/competent authority | Y/N | |
| 2 | Foundation | ||
| 2.0 | Foundation used | Existing/ New | |
| 2.1 | If existing foundation used | ||
| 2.1.1 | Depth of foundation below ground | <50 cm @ 50-70/> 70cm | |
| 2.1.2 | Type of masonry | Stone / Bricks / PCC Blocks | |
| 2.1.3 | Thickness of masonry (above ground) | 23cin /35 />35 | |
| 2.1.4 | Mortar used | Cement - Sand | |
| 2.1.5 | Mix of cement mortar | As per NBC Indicate | |
| 2.1.6 | Height up to Plinth | _____m, as per GDCR Y/N | |
| 2.1.7 | If stone masonry | ||
(Refer Rule No. 3.3.7, 5.1.4)
Fire Officer (FO) shall be required in all cases in which the provisions of Fire Chapter (Part 2) of these GDR related to fire safety are applicable within the meaning of clause 14.1.1 of the GDR. Fire Protection Consultant on Record (FPCOR) shall be required in all cases where either the building is High Rise or for the non-residential uses, the total built up area is more than 4000 sq m.
Page No 185
(Refer Rule No. 5.3)
It shall be the responsibility of the Owner or Developer and the Clerk of Works on Record to keep all the documents and drawings which are listed below at the site at all times during the entire Period of Construction from commencement to completion. These documents should be made available to any authorised officer of the Competent Authority inspecting the site for the purpose of enforcing the General Development Rules.
The following documents shall be kept on site during construction:
1 A set of the sanctioned drawings.
2 A copy of the valid Development Permission
Page No 201
Stages of Construction Work for which Notice for Progress of Construction to be Submitted to the Competent Authority
(Refer Rule No. 5.5.3)
The Architect on Record or Engineer on Record and the Owner or Developer shall be responsible for notifying the Competent Authority of construction having been completed up to the stages specified below. They shall also certify that the construction has been carried out in compliance with sanctioned drawings and to the Development Rules, using the format as prescribed in Form No. 20:
1 Lower Basement Slab Level
2 Plinth level
3 Ground Floor
4 Middle storey (in case of high-rise buildings)
5 Last storey (when the last structural roof has been completed)
Page No 202
Schedule No. 8 Inspection Requirements
(Refer Rule No. 5.6, 6.5.3)
Table No. S8A – 1: Principles of Risk Categorization (Definition of Consequence Class) and Inspection Requirements
| No. | Consequences Class | Description | Use and Building type | Design Super-vision Level | Supervision Requirements | Minimum recommended requirements for checking of calculations, drawings, and specifications. | Minimum requirements for Inspection of implementations and the insurance requirements. | Minimum Experience required |
|---|---|---|---|---|---|---|---|---|
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) |
| 1 | CC1 | • Low consequence for loss of human life. • Negligible economic, social, or environmental consequences, • Developed, owned, and maintained by single owner | Following development carried out in all areas other than Seismic Zone 5: Dwelling 1 Agro-Based Storage (Agriculture 2) | SL1 | Supervision by the owner and POR | Self-checking: Checking performed by the person who has prepared the design. Self-certification of design by the architect and the structural engineer appointed by the owner. | Self-certification by the architect and the structural engineer appointed by the owner for carrying out the construction as per drawings and specifications and for which the plans are approved. The POR shall for all levels submit the reports and submission of completion plan. No inspection to be carried out by the Inspector of the competent authority and shall issue the building use permission based on the documents supplied by the owner and POR The competent authority shall not insist on the insurance for the building. | As per regulation no. AOR, EOR and SEOR registration |
Page No 203
| No. | Consequences Class | Description | Use and Building type | Design Super-vision Level | Supervision Requirements | Minimum recommended requirements for checking of calculations, drawings, and specifications. | Minimum requirements for Inspection of implementations and the insurance requirements. | Minimum Experience required |
|---|---|---|---|---|---|---|---|---|
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) |
| 2 | CC2 | Low consequence for loss of human life; small or negligible economic, social, or environmental consequences, but the developer, owner or the person who may maintain may not the same person. | For the following development where the building height does not exceed 13.5m: Dwelling 2 Mercantile 1 | SL2 | Normal supervision by POR and the Competent Authority | Self-checking: Checking performed by the person who has prepared the design. Self-certification of design by the architect and the structural engineer appointed by the owner. | Self-certification by the architect and the structural engineer appointed by the owner for carrying out the construction as per drawings and specifications and for which the plans are approved. The POR shall for all levels submit the reports and submission of completion plan. Inspection to be carried out by the Inspector of the competent authority at the plinth level and at time when the owner makes an application for getting building use permission. The building use permission shall issue based on the inspection report and the documents supplied by the owner and POR. The competent authority shall not insist on the insurance for the building. | One year after registration as AOR, EOR, SEOR for respective task |
| 3 | CC3 | Medium consequence for loss of human life; considerable economic, | For the following development | SL3 | Normal supervision by POR and the | Checking by different persons in | Certification by the architect and the structural engineer appointed by the | Two years after registration as AOR for respective task |
Page No 204
| No. | Consequences Class | Description | Use and Building type | Design Super-vision Level | Supervision Requirements | Minimum recommended requirements for checking of calculations, drawings, and specifications. | Minimum requirements for Inspection of implementations and the insurance requirements. | Minimum Experience required |
|---|---|---|---|---|---|---|---|---|
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) |
| social, or environmental consequences | where the building height does not exceed 25m: Dwelling 3 Dwelling 4 Hospitality 2 Mercantile 1 Mercantile 2 Mercantile 3 Assembly 4 Health 2 | Competent Authority | accordance with the procedure prescribed in these rules no 3, 5, 6 and 7. Plinth and occupancy inspection and certification by structure designer. | owner for carrying out the construction as per drawings and specifications and for which the plans are approved. The POR shall for all levels submit the reports and submission of completion plan. Inspection to be carried out by the Inspector of the competent authority at the at all levels as required in regulation no 4, 5 and 6. The building use permission shall issue based on the inspection reports and the documents supplied by the owner and POR. The competent authority shall ask the owner to seek insurance coverage for the building for minimum 5 years and then only issue the building use permission. | ||||
| 4 | CC4 | High consequence for loss of human life; High consequences for economic, social, or | For the following development where the | SL4 | Extended supervision | Checking by different persons in accordance with | Certification by the architect and the structural engineer appointed by the owner for carrying out the | Three year after registration as AOR for respective task |
Page No 205
| No. | Consequences Class | Description | Use and Building type | Design Super-vision Level | Supervision Requirements | Minimum recommended requirements for checking of calculations, drawings, and specifications. | Minimum requirements for Inspection of implementations and the insurance requirements. | Minimum Experience required |
|---|---|---|---|---|---|---|---|---|
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) |
| environmental consequences | building height exceeding 25m but up to 45m: Hospitality 1 Hospitality 2 Hospitality 3 For the following development where the building height exceeding 13.5m but up to 45m: Service Establishment1Service Establishment2Mercantile 1 Mercantile 2 Storage For the following development having up to 45m: Education 1 | the procedure prescribed in these rules no 3, 5, 6 and 7. Plinth and occupancy inspection and certification by structure designer. | construction as per drawings and specifications and for which the plans are approved. The POR shall for all levels submit the reports and submission of completion plan. Inspection to be carried out by the Inspector of the competent authority at the at all levels as required in regulation no 4, 5 and 6. The building use permission shall issue based on the inspection reports and the documents supplied by the owner and POR The competent authority shall ask the owner to seek insurance coverage for the building for minimum 15 years and then only issue the building use permission. |
Page No 206
| No. | Consequences Class | Description | Use and Building type | Design Super-vision Level | Supervision Requirements | Minimum recommended requirements for checking of calculations, drawings, and specifications. | Minimum requirements for Inspection of implementations and the insurance requirements. | Minimum Experience required |
|---|---|---|---|---|---|---|---|---|
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) |
| Education 2 Education 3 Assembly 1 Assembly 2 Assembly 3 Assembly 4 Religious Recreation 1 Recreation 2 Sports and Leisure Industrial 1 Industrial 2 Industrial 3 Agriculture 1 Agriculture 2 Temporary Use Utility Public office Health 1 Health 2 Health 3 Health 4 Transport Storage Environmental Preservation 1 Environmental Preservation 2 Environmental |
Page No 207
| No. | Consequences Class | Description | Use and Building type | Design Super-vision Level | Supervision Requirements | Minimum recommended requirements for checking of calculations, drawings, and specifications. | Minimum requirements for Inspection of implementations and the insurance requirements. | Minimum Experience required |
|---|---|---|---|---|---|---|---|---|
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) |
| Preservation 3 Cremation and Burial All others not specified. |
Page No 208
Page No 209
Schedule No. 9
(Refer Rule No. 5.2)
It shall be the responsibility of the Owner or Developer and the Clerk of Works on Record to erect a notice board on the site of development displaying the key information pertaining to the Building Unit.
Information that shall be displayed on the Notice Board:
1 Name and address of the proposed building.
2 Sanctioned Use of the Building (use as sanctioned in the Development Permission).
3 Survey No, City Survey No, Block No., Final Plot No., Sub Plot/ Property No., and complete address of the plot.
4 Name of the Owner(s) / Developer(s)
5 Names and Registration Numbers of duly appointed Persons on Record on the project:
a Architect on Record/ Engineer on Record
b Structural Engineer on Record, and
c Clerk of Works on Record
d Supervisor of works on Record
e Fire Protection Consultant on Record, as applicable
Failure to comply with the above requirements may result in cancellation of the Development Permission
Page No 200
(Refer Rule No. 6.5.1)
The following documents and drawings shall be submitted along with the Application for Occupancy Certificate for a building:
Schedule No. 10
1 One set of Completion Plans and as‐built drawings, duly certified by POR.
2 Form No. 2: Certificates of Undertaking by the Architect on Record or Engineer on Record.
3 Form No. 2: Certificates of Undertaking by the Structural Engineer on Record.
4 Form No. 2: Certificates of Undertaking by the Clerk of Works on Record.
5 Form No. 2: Certificates of Undertaking by the FPCOR.
6 Clearance from Fire Officer, as applicable and mentioned in Schedule No. 4.
7 Certificate of Lift Inspector for buildings taller than 15 m.
8 A copy of valid Registration Certificate of the Persons on Record issued by the Competent Authority.
Receipt of Occupancy Certificate Fees and Charges paid as per Rule No.6.5.2 and Schedule No. 5B and of other charges leviable on the building‐unit shall be attached with the application.
(Refer Rule No. 16.2, 16.7.2, 19.1.2)
Class 1 Buildings: All types of framed structures, factory buildings, special buildings, buildings for educational use such as schools, colleges, etc; hostels and other public buildings.
Class 2 Buildings: Masonry walled residential buildings with height more than 10 m.
The interval at which buildings are to be examined and a Structural Inspection Report in Format as per Form 15 submitted to Competent Authority shall be as under:
For Class 1 buildings which are erected fifteen years earlier from the date on which these Rules has come into force or which becomes five years old thereafter:
1 Within three years from the coming into force of these Rules
2 Thereafter at the interval of every fifteen years from the date of submission of the first report
For Class 2 buildings which are erected fifteen years earlier from the date on which these Regulation has come into force or which become fifteen years old thereafter:
1 Within five years from the coming into force of these Rules
2 Thereafter at the interval of every fifteen years from the date of submission of the first report
The interval at which buildings are to be examined by Fire Officer or FPCOR and a Fire Safety Certificate as stipulated in Form 27 be submitted to Competent Authority shall be as under:
1 Within one year from the coming into force of these Rules
2 Thereafter at the interval not more than 12 months from the date of submission of the first certificate.
Page No 210
Page No 211
(Refer Rule Nos. 3.3.2, 3.3.3, 3.3.4, 3.3.5, 3.3.6, 3.3.7)
To,
The Competent Authority
Proposed Development:
(Title of the work)
Plot No /Sub Plot No.: ____
Survey No.: ____
Area of the Plot / Sub Plot: ____ (sq m)
Final Plot No.: ____
Area of Survey No.: ____ (sq m)
Area of Final Plot No.: ____ (sq m)
Full Address of Proposed Development: ____ ____
Name of the Owner / Developer: ____
Sir / Madam,
This is to bring to your notice that I have been relieved of my responsibility / have relieved myself of my responsibility as (Architect / Civil Engineer / Structural Engineer / Clerk of Works / Supervisor of Works/ Fire Protection Consultant on Record for the proposed building, with effect from ____(date).
I wish to place on record that with effect from the said date, I shall neither be associated with this building nor be responsible for its compliance to the sanctioned design and specifications and to the Development Rules.
Name:
Registration No.:
Address:
____
Tel. No.:
Email:
Signature:
Date: ____
Page No 222
Form No. 5 Notice of Cancellation of Development Permission
Page No 223
General Development Rules- Part 3(I), 2023
(Refer Rule No. 4.4.3)
To
____
File No: ____
Dated: ____
Proposed Development:
(Title of the work)
Plot No /Sub Plot No.: ____
Survey No.: ____
Area of the Plot / Sub Plot: ____ (sq m)
Area of Survey No.: ____ (sq m)
Final Plot No.: ____
Area of Final Plot No.: ____ (sq m)
Full Address of Proposed Development:
____
Name of the Owner / Developer: ____
Sir,
This is to notify you that the Direct / Development Permission No. ____ issued /granted on date: ____ by ____ AOR / CEA / PDA been cancelled by the Chief Executive Authority / Member Secretary on the following grounds:
Please note that no further construction may be undertaken on the plot. A new Development Permission has to be obtained before undertaking any further construction on the plot.
Yours faithfully
The Competent Authority
Form No. 6 Notice to Stop Unauthorized Development
(Refer Rule No. 4.7.2)
To
(1) (y)/(x) = (x)/(y) + 1
File No: ____
Dated: ____
Proposed Development:
(Title of the work)
Plot No /Sub Plot No.: ____
Survey No.: ____
Area of the Plot / Sub Plot: ____ (sq m)
Final Plot No.: ____
Area of Survey No.: ____ (sq m)
Area of Final Plot No.: ____ (sq m)
Full Address of Proposed Development:
____ ____
Name of the Owner / Developer: ____
Sir,
This is to notify you the development constructed on the plot is Unauthorized Development on the following grounds:
1
2
Please ensure that such development is stopped with immediate effect and that no use may be made of the development.
OR
This is to notify you that part of the development specified below, constructed on the plot is Unauthorized Development on the following grounds:
(Description of part of the development that is Unauthorized Development)
2
Please ensure that such construction is stopped with immediate effect and that no use may be made of the part of the development specified above.
OR
This is to notify you that the development being undertaken on the plot is Unauthorized.
Development on the following grounds:
1
2
I hereby order that the development on the plot be stopped with immediate effect.
Yours faithfully
The Competent Authority
Page No 224
Form No. 7 Direct Development Permission
(See Rule No. 4.10.1)
To,
The Competent Authority
Proposed Development:
(Title of the work)
Plot No /Sub Plot No.: ____
Survey No.: ____
Area of the Plot / Sub Plot: ____ (sq m)
Area of Survey No.: ____ (sq m)
Final Plot No.: ____
Area of Final Plot No.: ____ (sq m)
Page No 225
Full Address of Proposed Development: ____ ____
Name of the Owner / Developer: ____
Form No. 8
I am currently registered as Architect on Record with Competent Authority and am fully conversant with the General Development Rules. I have been appointed as the Architect on Record of the proposed development. I hereby certify that I have verified the designs and specifications of the proposed development and certify that they comply with the General Development Rules.
I hereby issue a Direct Development Permission for construction of the proposed Development. This Direct Development Permission is to be read in conjunction with all other documents and drawings which are enclosed as per the provisions of Rule No 4.10.1 and its Schedules, and that all such documents, drawings, and specifications form part of this Direct Development Permission.
I further assure that the owner shall:
1 Comply all Rules required for safety
2 Submit the plans and documents to the Competent Authority.
3 Commence development only after the registration of this permission.
I fully understand that in case my certificate is found to be false, or if it is found that the Direct Development Permission issued by me is inconsistent with the General Development Rules or that I have not fulfilled my responsibilities as prescribed therein, the PDA / CA shall be at liberty to penalize me / revoke my registration as per the provisions of the Act and Rules.
Name of the AOR: ____
Registration No.: ____
Address: ____
Tele. No.: ____
Signature: ____
Date: ____
Documents and Fees Required with Application for Advertising Display & Communication Infrastructures
(Refer Rule No. 12.1)
The Owner / Developer shall submit to the Competent Authority the following documents for erecting Advertising Display:
A List of Documents
1 Receipt of Fees paid and of other charges leviable shall be attached with the application.
2 Certificate from Registered Structural Engineer for the stability, safety of display structure to be erected.
3A For tender cases the documents to be submitted are:
a Shop Establishment Number
b Sale tax number
c Income tax clearance certificate.
3B For Private property cases:
a Lay‐out plan.
b Structural detail plan.
c NOC from property holder.
d 2 copies of photograph of the actual site.
e Electricity Bill of last month.
f Property Tax Bill.
g Agreement copy.
h 1/14 nakal
i Ekrarnama
The fees for erection and maintenance of the Advertising Display shall be charged as decided by Competent Authority. The fees shall be paid by the applicant in advance, for the calendar year or part thereof as may be prescribed by the Competent Authority.
2 Competent authorities may also decide penalty norms for non‐compliance of Rules specified for Advertising Display Structures of various types.
The Owner / Developer shall submit to the Competent Authority the following documents for erecting Communications Infrastructure:
1 Receipt of Fees paid and of other charges leviable shall be attached with the application.
2 Structural Stability Certificate from Registered Structural Engineer for the stability, safety of display structure to be erected which shall be the liability of the Owner and the Registered Structural Engineer
3 Permission from the “Standing Advisory Committee on Radio Frequency Allocation” (SACFA) issued by Ministry of Telecommunications.
The fees for erection of the Communication Infrastructure shall be charged as revised by Competent Authority from time to time.
Schedule No. 12
List of Recommended Trees
(Refer Regulation No. 17.5)
Following list of trees are recommended for their suitability regarding shade and foliage:
Table No. S12 – 1: List of Trees
| No. | Common Name |
|---|---|
| 1 | Cocous Nucifera |
| 2 | Mangifera Indica |
| 3 | Palm Oil Tree |
| 4 | Polyalthia |
| 5 | Phoenix Sylvestris |
| 6 | Terminalia tomentosa |
| 7 | Butea Frondosa |
| 8 | Tectona Grandis |
| 9 | Bridelia Retusa |
| 10 | Anogeissus Latifolia |
| 11 | Lannea Coromandelica |
| 12 | Diospyros Melanoxylon |
| 13 | Madhuca Indica |
| 14 | Borassus Flabellifer |
| 15 | Cascabela thevetia |
| 16 | Ficus Benghalensis |
| 17 | Azadirachta Indica |
| 18 | Delonix Regia |
| 19 | Saraca Asoca |
| 20 | Ficus Religiosa |
| 21 | Syzygium Cumini |
| 22 | Tamarindus Indica |
| 23 | Abizia Saman |
| 24 | Madhuca Longifolia |
| 25 | Terminalia Catappa |
| 26 | Erythrina Variegata |
| 27 | Casuarina Equisetifolia |
| 28 | Ziziphus Jujuba |
| 29 | Ficus Virens |
| 30 | Tectona grandis |
| 31 | Dalbergia Sissoo |
| 32 | Santalum Album |
| 33 | Senegalia Catechu |
| 34 | Swoetenia |
Page No 212
Standalone multi-level public parking may be permissible in residential, mercantile, public office, industrial, recreational, assembly and transportation land use classification. 5% of the built-up area of the parking structure may be used for commercial activity. Other planning norms for such standalone parking buildings shall be as below:
1 Front / Road Margin: 12 metres.
2 All other three sides: 7.5 metres.
3 Building height: To be determined in each case by the Competent Authority.
4 Parking floors: Where the plot size is not less than 1000 sq m cover parking with a clear height of not more than 2.4 metres may be permitted on any floor of the building according to the requirement of the FAR. If such parking is provided on the entire floor area, then such parking floor would not be included in the height of the building.
Page No 213
Page No 214
Forms
Page No 215
Page No 216
Page No 217
Form No. 1 Application for Registering as Person on Record
(Rule No. 3.2.1)
To,
The Competent Authority
1 Name:
2 Local Address:
3 Permanent Address:
4 Telephone/Fax No:
Qualification:
6 Membership of Professional:
7 Associations (Indicate appropriate professional affiliations)
8 Experience (No. of years):
9 Previous year’s Registration No.
10 Name of Employer: (if employed)
11 PAN Number:
12 Aadhar Number:
13 Bank Account Details:
Kindly register me as (Architect on Record / Civil Engineer on Record / Structural Engineer on Record / Clerk of Works on Record / Supervisor on Record / Developer) of the Competent Authority. I meet with the minimum qualifications and competence requirements as specified in Rule No. 3.2.1 and Schedule No. 1. Relevant documents attesting to the same are attached herewith.
I hereby undertake to abide by all rules, regulations, standing orders, requisitions and instructions given by the Competent Authority and shall carry out my responsibilities as prescribed in the General Development Rules. I also understand that if I fail to perform my responsibilities as above, the Competent Authority reserves the right to de‐ register me, forfeit my security deposit and take other appropriate action as defined in the General Development Rules as per the provisions of the Act.
Name of the Applicant:
Date:
Signature:
Form No. 2 Certificate of Undertaking for Persons on Record
(Refer Rule No. 3.3.2, 3.3.3, 3.3.4, 3.3.7)
To,
The Competent Authority
Proposed Development:
(Title of the work)
Plot No /Sub Plot No.: ____
Survey No.: ____
Area of the Plot / Sub Plot: ____ (sq m)
Area of Survey No.: ____ (sq m)
Final Plot No.: ____
Area of Final Plot No.: ____ (sq m)
Full Address of Proposed Development: ____ ____
Name of the Owner / Developer: ____
Sir / Madam,
A I am currently registered as Architect on Record with the Competent Authority as per Rule Nos. 3.3.1 and 3.3.2.
I, hereby certify that I am appointed as the Architect on Record to prepare the plans, sections and details as required under the General Development Rules for the above-mentioned project and that I have prepared and signed the same and that the execution of the project shall be carried out under my direction and supervision of supervisor or owner, as per the approved drawings. I am fully conversant with the provisions of the Rules, which are in force, and about my duties and responsibilities under the same and I undertake to fulfil them in all respects, except under the circumstances of natural calamities.
I fully understand that in case my certificate/s is found to be false, or if it is found that I have not fulfilled my responsibilities as prescribed therein, the Competent Authority shall be at liberty to penalize me as per the provisions of the Act.
Dadra and Nagar Haveli Planning and Development Authority
B I am currently registered as Civil Engineer on Record with the Competent Authority as per Rule Nos. 3.3.1 and 3.3.3.
I, here by certify that I am appointed as the Civil Engineer on Record to prepare the plans, sections and details as required under the General Development Rules for the above-mentioned project and that I have prepared and signed the same and that the execution of the project shall be carried out under my direction and supervision of supervisor or owner, as per the approved drawings. I am fully conversant with the provisions of the Rules, which are in force, and about my duties and responsibilities under the same and I undertake to fulfil the min all respects, except under the circumstances of natural calamities.
Notice to the Competent Authority of Non-Compliance of Building to Sanctioned Design and Specifications
(Refer Rule Nos. 3.3.2, 3.3.3, 3.3.4, 3.3.5, 3.3.6, 3.3.7)
To,
The Competent Authority
Proposed Development:
(Title of the work)
Plot No /Sub Plot No.: ____
Survey No.: ____
Area of the Plot / Sub Plot: ____ (sq m)
Final Plot No.: ____
Area of Survey No.: ____ (sq m)
Area of Final Plot No.: ____ (sq m)
Full Address of Proposed Development: ____ ____
Name of the Owner / Developer: ____
Sir / Madam,
I am currently registered as (Architect / Civil Engineer / Structural Engineer / Clerk of Works Supervisor of Works / Fire Protection Consultant on Record with the Competent Authority. I have been appointed as (Architect / Civil Engineer / Structural Engineer / Clerk of Works / Supervisor of Works / Fire Protection Consultant on Record) on Record for the proposed building.
This is to bring to your notice that construction of the building is not being undertaken in accordance with the sanctioned design and specifications and/or with the following General Development Rules. Details of non-compliance are as follows:
1
2
3
Name:
Registration No.:
Address:
____
Tel. No.:
Email:
____
Signature:
Date:
(Refer Rule No. 4.16.1)
Application for development permission under sections 44, 49 and 66 of The Dadra and Nagar Haveli and Daman & Diu Town & Country Planning Act, 1974, as the case may be.
To,
The Competent Authority
I / We hereby apply for permission for the Development Permission for Temporary Construction
The information sheet is enclosed with this application. All drawings and documents as per Schedule No. 6D are enclosed with this application.
The names of the persons on record are as under:
a) The plans are prepared by Registered Architect / Civil Engineer:
(Please specify the license number and date of expiry)
b) The structural report, details and drawings are prepared and supplied by Registered Structural Engineer: (if Applicable)
(Please Specify the license number and date of expiry)
c) The site supervision of the construction work will be done by Registered Clerk of Work: (if Applicable)
(Please Specify the license number and date of expiry)
I shall be responsible for ensuring that the development complies with the Development Rules framed by the Competent Authority under the provisions of the Act. I shall fulfil my duties and responsibilities in accordance with the provisions of the Development Rules.
Signature of Owner / Developer or Authorized Agent of Owner Date:
Page No 232
Table No. F10C – 1: Information Sheet with Application for Development Permission for Temporary Construction
| No. | Title | Details | |||
| 1 | Ownership Details | ||||
| 1.1 | Applicant's Name | ||||
| 1.2 | Postal Address for correspondence | ||||
| 1.3 | Address of Land in Question | ||||
| 1.4 | Applicants interest / title in land with respect of record of rights | ||||
| 2 | Land Details - Legal | ||||
| 2.1 | Land Description | ||||
| 2.2 | Village Name | ||||
| 2.3 | TPS/Revenue village / Gamtal | ||||
| 2.4 | FP No/ Revenue Survey No./ C S No | ||||
| 2.5 | Sub-Plot No/Tenement No | ||||
| 2.6 | Ward | ||||
| 2.7 | Zone | ||||
| 2.8 | Details of Approval before taken | ||||
| 3 | Was land in question used for temporary construction in the past? | ||||
| 3.1 | Yes/ No | If YES, please specify details | |||
| 4 | Land Occupancy Type Existing | Tick as applicable | Land Occupancy Type- Proposed | Tick as applicable | |
| 4.1 | Vacant | Vacant | |||
| 4.2 | Partly - Built | Partly - Built | |||
| 4.3 | Fully - Built | Fully - Built | |||
| 5 | Site Details | ||||
| A Width of Road Abutting the Site | TP Road | Non-TP Road/DP Road/Other Road | BRTS Corridor | ||
| 5.1 | Road 1: Front Side | ||||
| 5.2 | Road 2: Other than Front Side | ||||
| 5.3 | Road 3: Other than Front Side | ||||
| 5.4 | Road 4: Other than Front Side | ||||
| B Seismic Details | Yes/ No | Zone No. | Details | ||
| 5.5 | Seismic Zone | ||||
| C Water Supply | Available by Local Government/Authority | Bore Well | |||
| 5.6 | Water Supply Facility in Building-unit | ||||
| D Drainage | Available by Local Government/Authority | Not Available | |||
| 5.7 | Drainage Facility in Building- unit | ||||
| E Storm Water | City Network | Percolation Pit/ Percolating Well/ Recharge Pit | |||
| 5.8 | Storm Water Facility in Building-unit | ||||
| F Solid Waste Disposal | Local Government/Authority | None | |||
| 5.9 | Solid Waste Disposal Facility in Building-unit | ||||
| G Electricity | Available by Torrent/GEB/Other | None | |||
| 5.10 | Electricity facility in Building- unit | ||||
| 6 | Land-Use Details | ||||
| A Existing Use | Details | ||||
Page No 233
| No. | Title | Details | ||||
| Use Sub-type | Total Units | Max. Height. | Total Area | |||
| 6.1 | Residential | |||||
| 6.2 | Commercial | |||||
| 6.3 | Mixed Use | |||||
| 6.4 | Industrial | |||||
| 6.5 | Others (please specify) | |||||
| B Proposed Use | Details | |||||
| 6.6 | Residential | |||||
| 6.7 | Commercial | |||||
| 6.8 | Mixed Use | |||||
| 6.9 | Industrial | |||||
| 6.10 | Others (please specify) | |||||
| Attachments: Annexure as above | ||||||
Page No 234
Form No. 11A Area Statement for Buildings
(See Schedule No. 6A)
Table No. F11A – 1: Area Statement for Buildings
| No | Title | Details (Area in sq m) | Supporting Documents Provided Yes / No / Not required | ||||
| A | Building-unit Area | ||||||
| A.1 | (a) | As per Revenue Record | |||||
| A.2 | (b) | As per TPS Record | |||||
| A.3 | (c) | Per site condition | |||||
| B | Deduction Area | ||||||
| B.1 | (a) | Roads (Proposed or under process) | |||||
| B.2 | (b) | Reservations (under TP or DP or any other Statutory Plans / Under provision of GDR) | |||||
| B.3 | Area- not in possession | ||||||
| B.4 | Other | ||||||
| C | Net Area | ||||||
| Existing | |||||||
| No | Title | Details (Area in sq m/ Nos./ m) | Supporting Documents Provided Yes / No / Not required | ||||
| Required | Provided | ||||||
| 1 | Common Plot | ||||||
| 2 | Width of Roadside Margin | ||||||
| 2.1 | Width of Other than Roadside Margin | ||||||
| 2.2 | Total Marginal Area | ||||||
| 3 | Width of Internal Road | ||||||
| 3.1 | Internal Road Area | ||||||
| 4 | Total Permissible Ground-coverage | ||||||
| 5 | Permissible FSI - Base (as per old DP) | ||||||
| 6 | Permissible FSI - Chargeable | ||||||
| 7 | FSI Consumed | ||||||
| 8 | Ground Coverage | ||||||
| 9 | Use | Use Sub-type | Total Built- up Area (in sq m) | No. of Units | |||
Page No 235
| No | Title | Details (Area in sq m) | Supporting Documents Provided Yes / No / Not required | ||
| 10.6 | Total of all buildings | ||||
| 10.7 | Building | Building Height in mt | Number of Floors | ||
| 11 | Dwelling Units | Numbers of Units | Total Unit Area (In sq m) | Details of unit area (Size)of Individual Unit (in sq m) | |
| Provide Details for individual Building | |||||
| 11.1 | 1BHK | ||||
| 11.2 | 2BHK | ||||
| 11.3 | 3BHK | ||||
| 11.4 | 4BHK | ||||
| 11.6 | More than 4BHK | ||||
| 11.7 | Others (e.g., Studio units, penthouse etc.) | ||||
| 11.8 | Other than Dwelling Units | ||||
| 11.9 | Total | ||||
| 11.10 | Total of all buildings | ||||
| 12 | Basement | Number of Basement | Area per Basement (in sq m) | Total Basement Area | |
| 12.1 | Basement 1: Area | ||||
| 12.2 | Basement 2: Area | ||||
| 12.3 | Others | ||||
| Existing Area Statement for Parking | |||||
| 13 | Parking | Area (in sq m) | Percentage (%) | ||
| 13.1 | Area under parking (including visitors parking) | % of Total Built-up Area | |||
| 13.2 | Visitors Parking | % of Total Parking Area | |||
| 13.3 | Covered Parking | % of Total Parking Area | |||
| 13.4 | Open Parking | % of Total Parking Area | |||
| 13.5 | Sports & Leisure | ||||
| 13.6 | Parks | ||||
| 13.7 | Service establishment | ||||
| 13.8 | Industrial | ||||
| 13.9 | Storage | ||||
| 13.10 | |||||
Page No 236
| No | Title | Details (Area in sq m) | Supporting Documents Provided Yes / No / Not required | ||||
| 15.1 | 1BHK | ||||||
| 15.2 | 2BHK | ||||||
| 15.3 | 3BHK | ||||||
| 15.4 | 4 BHK | ||||||
| 15.5 | More Than 4BHK | ||||||
| 15.6 | Others (e.g., Studio units, penthouse etc.) | ||||||
| 15.7 | Other than Dwelling Units | ||||||
| 15.8 | Total | ||||||
| 15.9 | Total of all buildings | ||||||
| 16 | Dwelling Units | Carpet Area of each Unit (in sq m) | Details of Balcony & Verandah area (Size) of Individual Unit (in sq m) | Proportionate Common Amenities area in sq m | Total Built up Area (sq m) | ||
| 16.1 | Ground Floor | ||||||
| 16.2 | First Floor | ||||||
| 17 | Building | Building Height in meters | Number of Floors | ||||
| 18 | Floor Level | Each Dwelling Unit (DU) No. | Carpet Area of Each DU (in sq m) | Total Carpet Area of Each Type (In sq m) | Total Carpet Area on Each Floor (in sq m) | ||
| Ground Floor | |||||||
| First Floor | |||||||
| Proposed Area Statement for Parking | |||||||
| 19 | Parking | Area (in sq m) | Percentage (%) | ||||
| 19.1 | Parking Area required as per Regulation (please specify in % as well as area) | %Of Total Built-up Area | |||||
| 19.2 | Proposed Parking Area (please specify in % as well as area) | % Of Total Built-up Area | |||||
| 19.3 | Visitors parking area required at Ground Level (please specify in % as well as area) | ||||||
Page No 237
| No | Title | Details(Area in sq m) | Supporting Documents Provided Yes / No / Not required | |||
| Description of proposed property | ||||||
| List of Drawings | No. of Copies | North | Scale of drawing | Remarks | ||
| Plans | ||||||
| Layout Plan | ||||||
| Site plan | ||||||
| Detailed Plan | ||||||
| Sections | ||||||
| Elevations | ||||||
| Services & Amenities Plan | ||||||
| Landscape Plan | ||||||
| Ref Description of last approved plans (If any) | Date | |||||
Page No 238
Form No. 11B
Area Statement for Subdivision / Amalgamation / Layout of Land
(See Schedule No. 6B)
Table No. F11B – 1: Area Statement for Subdivision / Amalgamation / Layout of Land
| No. | Area Statement Particular | Sq m | ||||
| 1 | Area of Plot/Plots | 1. List of Drawing attached | No. of copies | |||
| 1.1 | Internal Road Area | |||||
| 1.2 | Common plot/ Plots | |||||
| 1.3 | Amalgamated Area (in case of amalgamation) | |||||
| 2 | Deduction for: | |||||
| 2.1 | Proposed roads | 2. Ref. & Description of Last approved plans if any | Date | |||
| 2.2 | Any reservation | |||||
| 2.3 | Not in Possession | |||||
| 2.4 | Other | |||||
| Total: (a+b+c+d) | ||||||
| 3 | Net area of plot (1-2) | |||||
| 4 | (In case of Sub-Division) Common plot / Plots Internal Roads | 3. Description of proposed development and property | ||||
| 5 | Balance area of Sub plot/sub plots (3-4) | |||||
| Permissible F.S.I. | ||||||
| Total Built-up area permissible | 4. | |||||
| 6 | Existing floor area | North line | Scale | Remarks | ||
| F.S.I. | ||||||
| Notes: | ||||||
| 5. Certificate | ||||||
| Certified that the plot under reference was surveyed by me on and the dimensions of sides etc. of plot state on plan are as measure on site and the area so worked out tallies with the area stated in document of ownership / T.P. record. Architect/Engineer Signature. | ||||||
| 6. Signatories | ||||||
| Signatory, Name, and address with | ||||||
| Regn. No. | ||||||
| Owner/ Developer/ | ||||||
| Architect/ | ||||||
| Engineer/Clerk of works/Site supervisor | ||||||
| A | Area Statement | Sq m | |||
| For Subdivision/ Amalgamation/ Layout of Land | 1 | Area of Plot/Plots | I. List of Drawing attached | No. of copies | |
| Internal Road Area | |||||
| Common plot/ Plots | |||||
| Amalgamated Area (in case of amalgamation) | |||||
| 2 | Deduction for: | ||||
| (a) Proposed roads | II. Ref. & Description of Last approved plans if any | Date | |||
| (b) Any reservation | |||||
| (c) Not in Possession | |||||
Page No 239
| A | Area Statement | Sq m | ||||
| (d) Other | ||||||
| SITE PLAN (Under regulation no. 4.10.1/4.11.1/4.16.1) | 3 | Total: (a+b+c+d) | ||||
| Net area of plot (1-2) | ||||||
| Layout Plan (under regulation no. 4.12, 4.13, 4.14, 4.15) | 4 | (In case of Sub-Division) Common plot/ Plots Internal Roads | III. Description of proposed development and property | |||
| 5 | Balance area of Sub plot/sub plots (3-4) | |||||
| Permissible F.S.I. | ||||||
| Total Built-up area permissible | IV. | |||||
| Existing floor area | North line | Scale | Remarks | |||
| F.S.I. | ||||||
| Notes: | ||||||
| V. Certificate | ||||||
| Certified that the plot under reference was surveyed by me on and the dimensions of sides etc. of plot state on plan are as measure on site and the area so worked out tallies with the area stated in document of ownership / T.P. record.Architect/Engineer Signature. | ||||||
| VI. Signatories | ||||||
| Signatory, Name, and address with | ||||||
| Regn. No. | ||||||
| Owner/ Developer/ | ||||||
| Architect/ | ||||||
| Engineer/Clerk of works/Site supervisor | ||||||
Page No 240
Form No. 11C Area Statement for Temporary Construction
(See Schedule No. 6D)
Table No. F11C-1: Area Statement for Temporary Construction
| No. | Area Statement Particular | Sq m | ||||
| 1 | Area of Plot/Plots | 1. List of Drawing attached | No. of copies | |||
| 1.1 | Internal Road Area | |||||
| 1.2 | Common plot/ Plots | |||||
| 1.3 | Amalgamated Area (in case of amalgamation) | |||||
| 2 | Deduction for: | |||||
| 2.1 | Proposed roads | 2. Ref. & Description of Last approved plans if any | Date | |||
| 2.2 | Any reservation | |||||
| 2.3 | Not in Possession | |||||
| 2.4 | Other | |||||
| Total: (a+b+c+d) | ||||||
| 3 | Net area of plot (1-2) | |||||
| 4 | (In case of Sub-Division) Common plot / Plots Internal Roads | 3. Description of proposed development and property | ||||
| 5 | Balance area of Sub plot/sub plots (3-4) | |||||
| Permissible F.S.I. | ||||||
| Total Built-up area permissible | 4. | |||||
| 6 | Existing floor area | North line | Scale | Remarks | ||
| F.S.I. | ||||||
| Notes: | ||||||
| 5. Certificate | ||||||
| Certified that the plot under reference was surveyed by me on and the dimensions of sides etc. of plot state on plan are as measure on site and the area so worked out tallies with the area stated in document of ownership / T.P. record. Architect/Engineer Signature. | ||||||
| 6. Signatories | ||||||
| Signatory, Name, and address with | ||||||
| Regn. No. | ||||||
| Owner/ Developer/ | ||||||
| Architect/ | ||||||
| Engineer/Clerk of works/Site supervisor | ||||||
Page No 241
(See Rule No. 4.10.1)
To,
The Competent Authority
Proposed Development:
(Title of the work)
Plot No /Sub Plot No.: ____
Survey No.: ____
Area of the Plot / Sub Plot: ____ (sq m)
Final Plot No.: ____
Area of Survey No.: ____ (sq m)
Area of Final Plot No.: ____ (sq m)
Full Address of Proposed Development:
Name of the Owner / Developer: ____
Form No. 9
I am currently listed as Architect on Record with Competent Authority. I am fully conversant with the General Development Rules.
I have been appointed as the Architect on Record of the proposed development. I hereby certify that I have verified the design and specifications of the proposed development and certify that they comply with the General Development Rules of the PDA.
I have issued a Direct Development Permission for construction of the proposed Development and hereby apply for registration of the same on the records of the PDA.
I fully understand that in case my certificate is found to be false, or if it is found that the Direct Development Permission issued by me is inconsistent with the General Development Rules of the PDA shall be at liberty to penalize me.
Name of the AOR: ____
Registration No.: ____
Address: ____
Tele. No.: ____
Signature: ____
Date: ____
Page No 226
Page No 227
(See Reg. No. 4.12.1)
To,
The Competent Authority
Proposed Development:
(Title of the work)
Full Address of Proposed Development: ____ ____
Name of the Owner / Developer: ____
I am currently registered as Architect on Record with Competent Authority and am fully conversant with the General Development Rules. I have been appointed as the Architect on Record of the proposed development. I hereby certify that I have verified the revisions made to the designs and specifications of the proposed development and certify that they comply with the General Development Rules.
I hereby issue a Revised Direct Development Permission for construction of the proposed Development. This Revised Direct Development Permission is to be read in conjunction with all other documents and drawings which are enclosed as per the provisions of Rule No 4.14.1 and its Schedules, and that all such documents, drawings and specifications form part this Revised Direct Development Permission.
I fully understand that in case my certificate is found to be false, or if it is found that the Revised Direct Development Permission issued by me is inconsistent with the General Development Rules or that I have not fulfilled my responsibilities as prescribed therein, the PDA / CA shall be at liberty to penalize me / revoke my registration as per the provisions of the Act and Rules.
Name of the AOR: ____
Registration No.: ____
Address: ____
Tele. No.: ____
Signature: ____
Date: ____
Page No 244
Page No 245
(See Rule No. 4.12.1)
To,
The Competent Authority
Proposed Development:
(Title of the work)
Full Address of Proposed Development: ____ ____
Name of the Owner / Developer: ____
Sir,
I am currently listed as Architect on Record with Competent Authority. I am fully conversant with the General Development Rules.
I have been appointed as the Architect on Record of the proposed development. I hereby certify that I have verified the revisions to the design and specifications of the proposed development and certify that they comply with the General Development Rules of the PDA.
I have issued a Revised Direct Development Permission for construction of the proposed Development and hereby apply for registration of the same on the records of the PDA.
Grant / Refusal of Development Permission / Revised Development Permission / Revalidated Development Permission
(Refer Rule No. 4.11.3, 4.15.3)
Permission is hereby granted/refused under Section 44(3a) (i)/ 44(3a) (ii) / 44(3a) (iii)/ 44(3b) (1)/ 44(3b) (ii), 49, 66 of The Dadra and Nagar Haveli and Daman & Diu Town & Country Planning Act, 1974, as the case may be.
To
(Name of person)
Proposed Development:
(Title of the work)
Full Address of Proposed Development:
Name of the Owner / Developer: ____
Sir
With reference your application dated ____, for Development Permission for:
• Development on building unit
• Development of layout
• Subdivision of building unit
• Amalgamation of building unit
Has been
A Granted on following conditions before commencement of work (if any):
1 ____
2 ____ ____
Dadra and Nagar Haveli Planning and Development Authority
Development may be undertaken as per sanctioned design and specifications. This Development Permission is to be read in conjunction with all other document and drawings which enclosed as per the provision of Rule 4 and Schedule 6A, 6B, 6C & 6D, and that all such documents, drawings and specifications form a part of this Development Permission.
Page No 242
1 Documents /NOC etc.:
Following documents /plans /NOC / undertakings as mentioned in Form No. 1 are not submitted.
i) Site is not cleared as per the provisions of the Outline Development Plan with respect to
- Road line
- Reservations
- Zone
Page No 243
- Other (specify)
ii) Site is not cleared as per the provision of TP Scheme ____ with respect to - Road
- Reservation
- Final plot
- Other (specify)
iii) Proposed use is not permissible according to the width of road as per the Provision No.7.7.
Following provisions are not as per the Development Rules:
- Set back
- Margin
- Common plot
- Internal roads
- Parking space
- Ground coverage
(See Rule. No. 4.10.3, 4.12.3, 4.14.3)
To
____
File No: ____
Dated: ____
Proposed Development:
(Title of the work)
Plot No /Sub Plot No.: ____
Survey No.: ____
Area of the Plot / Sub Plot: ____ (sq m)
Final Plot No.: ____
Area of Survey No.: ____ (sq m)
Area of Final Plot No.: ____ (sq m)
Full Address of Proposed Development:
Name of the Owner / Developer: ____
Sir,
With reference to your application for registering issue of ____ (Direct Development Permission / Revised Direct Development Permission / Revalidated Direct Development Permission) on ____ (date), I am directed to inform you that the Issue of Direct Development Permission / Revised Direct Development Permission / Revalidated Direct Development Permission has been registered on the records of the PDA on ____ (date).
OR
With reference to your application for registering issue of ____ (Direct Development Permission / Revised Direct Development Permission/ Revalidated Direct Development Permission) on ____ (date), I am directed to inform you that the Direct Development Permission/ Revised Direct Development Permission/ Revalidated Direct Development Permission issued by you, has been cancel on the following grounds:
Yours faithfully
The Competent Authority
| 22B | Application for Occupancy of Temporary Construction |
| 23 | Grant / Refusal of Occupancy Certificate |
| 24 | Cancellation of Occupancy Certificate |
| 25 | Change in the Sanctioned Occupancy of Building / Development |
| 26 | Structural Inspection Report |
| 27 | Fire Safety Certificate |
| Details of Structural Inspection Report (Part 3) |
Page No 177
| No | Type of land Use | Rate per sq m of Building Unit (Subject to minimum fees of Rs. 1000/-) |
|---|---|---|
| 1 | Residential | Rs. 4.00 |
| 2 | Commercial | Rs. 8.00 |
| 3 | Residential Cum Commercial | Rs. 6.00 |
| 4 | Industrial | Rs. 10.00 |
| 5 | Public Offices, Utilities | Exempted |
| 6 | Others | Rs. 4.00 |
(*others: includes Health, Education, etc. and other than the above-mentioned type of land use)
A person applying for permission to carry out any development shall have to pay tree plantation deposit (Rs. 500 / tree required to be planted) along with his application to the Competent Authority. This deposit shall be refundable after the period of five years with the condition that trees planted on the site shall be grown up and maintained properly, otherwise the deposit shall be forfeited.
u) The lines of drainage of the building, the size, depth and inclination of every drain and the means to be provided for the ventilation of the drains.
v) The position and level of the outfall of the drain, any existing facilities regarding water supply, sewerage etc, diameter and gradient of water supply line, drainage lines for the disposal of storm water as well as for sewerage.
3 Site Plan for Subdivision and Amalgamation:
a) Minimum scale: 1:500 for building units / plots less than 100 hectares and 1:1000 for others.
b) Boundaries of the building unit / plot and of any contiguous plots belonging to the owner, position of the plot in relation to the neighbouring streets and street names and direction of north point relative to the plan of building.
c) Building unit level in relation to the neighbouring street level; all existing buildings standing on, over or under the plot.
Page No 193
d) The position of the building, and of all other buildings (if any) which the applicant intends to erect upon the contiguous land and referred to in (b) in relation to:
The boundaries of the building unit / plot and in case where the building unit / plot has been partitioned, the boundaries of the portion owned by the applicant and also of the portions owned by others.
ii All streets, buildings (with number of stories and height) and premises adjacent to the building unit / plot and of the contiguous land, if any, referred to in (b), and.
iii If there is no street within a distance of 12 m of the plot, the nearest existing street.
iv Any street prescribed under the Act and passing through the plot/s.
v Building lines and margins of streets
e) Sub‐division of the land or plot or building unit with dimension and area of each of the proposed sub‐divisions and their use according to these rules.
f) The width and length of the proposed streets and internal roads.
g) Dimensions and Areas of Open space to be left as per the Development Rules
h) Any existing natural or manmade physical features, such as wells, drains, trees, high tension line, gas pipeline, railway line, etc.
i) The area of the whole plot and the break‐up of covered area on each floor with the calculations for percentage covered as required under the Development Rules,
j) Dimensions and areas of common plot, as required under these rules, provided in the layout / sub‐division of plot.
6 Specifications
General specifications of the proposed building giving type and grade of material shall be signed by the Architect on Record and the Structural Engineer on Record.
| 5<sup>th</sup> offence (Rs.40,000) |
| Rule No. 6.5.1 and 6.6.1: Person on Record submits incomplete or inadequate drawings, document, and specifications to the PDA along with application to register Issue or grant of Development Use Permission or Permission to Change Sanctioned Use of Development | 1<sup>st</sup> offence (Rs. 10,000) | 2<sup>nd</sup> offence (Rs.15,000) | 3<sup>rd</sup> offence (Rs.20,000) | 4<sup>th</sup> offence (Rs.25,000) | 5<sup>th</sup> offence (Rs.30,000) |
| Rule Nos. 6.5 and 6.6: Person on Record intentionally and fraudulently misrepresents or hides material facts from the PDA in the application to register issue or grant of | 1<sup>st</sup> offence (Rs. 15,000) | 2<sup>nd</sup> offence (Rs.25,000) | 3<sup>rd</sup> offence (Rs.35,000) |
| 2.1.7.1 | Through Stones | Yes / No. If Yes Adequate/Inadequate |
| 2.1.7.2 | Corner Stones | Yes / No. If Yes Adequate/Inadequate |
| 2.2 | If a new foundation used |
| 2.2.1 | Depth of foundation below ground | <50/50-70/>70 cm |
| 2.2.2 | Type of masonry blocks | Stone / bricks / PCC |
| 2.2.3 | Thickness of Masonry above plinth - | 23cm/35/>35cm |
| 2.2.4 | Mortar used | Cement-sand / lime / mud |
| 2.2.5 | Mix of cement mortar (1:4)/As Per NBC | Yes/No |
| 2.2.6 | Height up to plinth | _____m, as per GDCR Y/N |
| 2.2.7 | If stone masonry |
| 2.2.7.1 | Through Stones | Yes / No. If Yes Adequate/Inadequate |
| 2.2.7.2 | Comer Stones | Yes / No. If Yes Adequate/Inadequate |
| 2.3 | Vertical reinforcement in foundation | Yes / No |
| 3 | Walls | ||
| 3.1 | Type of masonry | Stone/ Brick / PCC Blocks |
| 3.2 | Mortar used | Cement- Sand / Lime /Mud |
| 3.3 | Mix of cement mortar | 1:4 /1:1.6/Leaner |
| 3.4 | Thickness of wall | >23cm/23cm/23cm |
| 3.5 | Mixing of mortar | OK /Not OK |
| 3.6 | Join property filled | OK /Not OK |
Page No 182
| 3.7 | Wetting of bricks | Good / Medium / Poor | |
| 3.8 | Stone masonry | ||
| 3.8.1 | Through Stones | Yes/No | |
| 3.8.2 | Corner Stones | Yes / No | |
| 3.9 | Overall workmanship | Good / Medium / Poor | |
| 4 | Roofing | ||
| 4.1 | Type of roof | Flat / Sloping | |
| 4.2 | If sloped | Morbid tiles / AC sheet / G.I. sheet | |
| 4.3 | Purlins | Angle - | |
| Material - Iron/ Timber/ NA | |||
| 4.4 | Truss type | ||
| 4.5 | Anchorage with wall | Adequate / Inadequate /NA | |
| 5 | Materials | Specifications must be conforming to NBC/Relevant IS Codes | |
| 5.1 | Cement | ||
| 5.1.1 | Source | Authorized Dealer / Market OPC/PPC/ PSC | |
| 5.1.2 | Type of cement | Grade (33 / 43 / 53) | |
| 5.1.3 | If OPC | OPC / PPC/ PSC | |
| 5.2 | Sand | ||
| 5.2.1 | Type of sand | Fine / Coarse | |
| 5.2.2 | Presence of deleterious materials | Mild / Moderate / High | |
| 5.3 | Coarse Aggregates | ||
| 5.3.1 | Type coarse Aggregates | Gravel / Crushed Stone | |
| 5.3.2 | Presence of deleterious material | Mild / Moderate / High | |
| 5.4 | P.C.C. Blocks (Applicable for onsite production) | ||
| 5.4.1 | Type of P.C.C. Blocks | Solid blocks / Hollow blocks | |
| 5.4.2 | Ratio of concrete in block | ||
| 5.4.3 | Interlocking feature | Yes / No | |
| 5.4.4 | Coarse aggregates used | Natural / Crushed stone | |
| 5.5 | Bricks Blocks, Stone etc. | ||
| 5.5.1 | Strength (field assessment) | Low / Medium / High | |
| 5.5.2 | Dimensional accuracy | Yes / No | |
| 5.6 | Concrete | ||
| 5.6.1 | Mix of concrete | (1:1 1/2:3)/ (1:2:4)/ Design Mix | |
| 5.6.2 | Batching | Weight batching/ Volume batching | |
| 5.6.3 | Compaction | Vibrators / Thappies and rods | |
| 5.6.4 | Workability | Low / Medium / High | |
| 5.6.5 | Availability of water | Sufficient / Insufficient | |
| 5.6.6 | Curing | Satisfactory/ unsatisfactory | |
| 5.7 | Reinforcing Steel | ||
| 5.7.1 | Type of Steel | Plain mild steel HYSD bars | |
| 5.7.2 | Source | Authorized Dealer /Market | |
| 5.7.3 | Whether IS Marked | Yes/No | |
| 5.7.4 | Conditions of bars | Clean / Corrugated | |
| 5.7.5 | Fixing of reinforcement as per drawing | Yes / No | |
| 5.7.6 | Suitable cover | Yes/No | |
| 5.7.7 | Spacing of bars | Regular / Irregular | |
| 5.7.8 | Overlaps as per specifications | Yes / No | |
| 5.8 | Form Work | Timber/ Play board /Steet | |
| 5.8.1 | Type of form work | Yes/No | |
| 5.8.2 | Use of mould oil | ||
| 5.8.3 | Leakage of cement slurry | Observed / Not | |
| 5.9 | Source | ||
| 5.9.1 | Cement | ||
| 5.9.2 | Sand | ||
| 5.9.3 | Coarse Agg. | ||
Page No 183
| 5.9.4 | Bricks | ||
| 5.9.5 | PCC Blocks | ||
| 6 | Seismic Resistance Features for Masonry Structures | ||
| 6.1 | Provision of seismic band provided Adequate | Yes/No | |
| 6.1.1 | Plinth level | Yes/No | |
| 6.1.2 | Stilt level | Yes/No | |
| 6.1.3 | Lintel level | Yes/No | |
| 6.1.4 | Roof level (if applicable) | Yes/No | |
| 6.2 | If sloped roof, whether seismic bands are provided at | Yes/No | |
| 6.2.1 | Gable wall top | Yes/No | |
| 6.2.2 | Eaves level | Yes/No | |
| 6.3 | Provision of vertical street in masonry at | Yes/No | |
| 6.3.1 | Each corner | Yes/No | |
| 6.3.2 | Each T-junction | Yes/No | |
| 6.3.3 | Each door joint | Yes/No | |
| 6.3.4 | Around each window | Yes/No | |
| 6.4 | Openings | Yes/No | |
| 6.4.1 | Total width of openings (*-42% for double storey) | <50%/50*-60%/>60% | |
| 6.4.2 | Clearance from corner | Ok/ Not Ok | |
| 6.4.3 | Pier width between two opening | Ok/ Not Ok | |
| 7 | Workmanship | Specifications must be conforming to | |
| NBC/Relevant IS Codes | |||
Name of AOR Registration No.: Address: Tel. No.: Signature: Date:
Name of SEOR Registration No.: Address: Tel. No.: Signature: Date:
Name of SOR: Registration No.: Address: Tel. No.: Signature: Date:
Name of EOR:
Registration No.:
Address:
Tel No.:
Signature:
Date:
Name of COWOR:
Registration No.:
Address:
Tel No.:
Signature:
Date:
Page No 184
Page No 218
I fully understand that in case my certificate/s is found to be false, or if it is found that I have not fulfilled my responsibilities as prescribed therein, the Competent Authority shall be at liberty to penalize me as per the provisions of the Act.
C I am currently registered as Structural Engineer on Record with the Competent Authority as per Rule No. 3.3.1 and 3.3.4.
This is to certify that I am appointed as the Structural Engineer on Record to prepare the structural report, structural details, and structural drawings as required under the General Development Rules for the above-mentioned project. I am fully conversant with the Rules and of my duties and responsibilities under the Rules and assure that I shall fulfil them in all respects. I have prepared and signed the structural design and drawings of the proposed building as per the prevailing Indian Standard Specifications and further certify its structural safety and stability in design.
I fully understand that in case my certificate/s is found to be false, or if it is found that I have not fulfilled my responsibilities as prescribed therein, the Competent Authority shall be at liberty to penalize me as per the provisions of the Act.
D I, am currently registered as Clerk of Works on Record with the Competent Authority as per Rule Nos. 3.3.1 and 3.3.5.
This is to certify that I am appointed as the Clerk of Works on Record for the above-mentioned project. I am fully aware of my duties and responsibilities under the Rules and assure that I shall fulfil them in all respects. I shall undertake all necessary measures, including but not limited to adequate inspection during construction, to ensure that the construction of the building is undertaken in accordance with the detailed design and specifications provided by (name of the Architect on Record) and (name of the Structural Engineer on Record), and, with the sanctioned design and specifications.
• I undertake not to supervise more than ten works at a given time as provided in Development Rules.
- I undertake not to supervise work simultaneously at one point of time on any other sites during my supervision of the execution of this work.
I fully understand that in case my certificate/s is found to be false, or if it is found that I have not fulfilled my responsibilities as prescribed therein, the Competent Authority shall be at liberty to penalize me as per the provisions of the Act.
E I, am currently registered as Supervisor of Works on Record with the Competent Authority per Rule Nos. 3.3.1 and 3.3.6.
This is to certify that I am appointed as the supervisor of Works on Record for the above-mentioned project. I am fully aware of my duties and responsibilities under the Rules and assure that I shall fulfil the min all respects. I shall undertake all necessary measures, including but not limited to adequate inspection during construction, to ensure that the construction of the building is undertaken in accordance with the detailed design and specifications provided by (name of the Architect on Record) and (name of the Structural Engineer on Record), and, with the sanctioned design and specifications.
- I undertake not to supervise more than ten works at a given time as provided in Development Rules.
- I undertake not to supervise work simultaneously at one point of time on any other sites during my supervision of the execution of this work.
I fully understand that in case my certificate is found to be false, or if it is found that I have not fulfilled my responsibilities as prescribed therein, the Competent Authority shall be at liberty to penalize me as per the provisions of the Act.
Page No 219
F I, am currently registered as Fire Protection Consultant on Record with the Fire Officer per Rule Nos. 3.3.1 and 3.3.7
I is hereby certify that I have been appointed as the Fire Protection Consultant on Record of the proposed building. I am fully conversant with the Rules and of my duties and responsibilities under the Rules and as sure that I shall fulfil the min all respects. I have prepared and signed the fire safety drawings of the proposed building as per the Rules and further certify its fire safety.
I, is fully understand that in case my certificate is found to be false, or if it is found that I have not fulfilled my responsibilities as prescribed there in, the Competent Authority shall be at liberty to penalize me as per the provisions of the Act.
As per Rule No. 16 and Schedule 6A of these General Development Rules we all undersigned:
1 Certify that the building plans submitted for approval satisfy the safety requirements as stipulated under Rule No. 16 and the information given therein is factually correct to the best of our knowledge and understanding.
2 Certify that the structural design including safety from hazards based on soil conditions shall be duly incorporated in the design of the building and these provisions shall be adhered to during the construction.
Name of AOR
Registration No.:
Name of EOR:
Address:
Registration No.:
Tel. No.:
Address:
Signature:
Tel No.:
Date:
Signature:
Date:
Name of SEOR
Registration No.:
Name of COWOR:
Address:
Registration No.:
Tel. No.:
Address:
Signature:
Tel No.:
Date:
Signature:
Date:
Name of SOR:
Registration No.:
Name of FPCOR:
Address:
Registration No.:
Tel. No.:
Address:
Signature:
Tel No.:
Date:
Signature:
Date:
Signature of Owner /Developer with date:
Name:
Address:
Page No 220
Page No 221
| Drawings Provided Yes / No |
| Existing Use - as per old DP | ||||||
| 9.1 | Residential | |||||
| 9.2 | Commercial | |||||
| 9.3 | Mixed Use | |||||
| 9.4 | Industrial | |||||
| 9.5 | Others (please specify) | |||||
| 9.6 | Total | |||||
| 10 | Floors | Numbers of Units | Floor Area/ Built-up Area/FSI (in sq m) | Payment FSI (in sq m) | |||
| Provide Details for Individual Building |
| 10.1 | Hollow Plinth | |||||
| 10.2 | Ground Floor | |||||
| 10.3 | Typical Floor | |||||
| 10.4 | Floors other than Typical Floor | |||||
| 10.5 | Total | |||||
| Transport |
| 13.11 | Agriculture |
| 13.12 | Temporary Use |
| 13.13 | Public Utility |
| 13.14 | Public Institutional |
| 13.14 | Total |
| 14 | Floors/Levels | Numbers of Units | Floor Area/ Built-up Area/FSI (in sq m) | Payment FSI (in sq m) | |
| Provide Details for individual Building |
| 14.1 | Basement |
| 14.2 | Hollow Plinth |
| 14.3 | Ground Floor |
| 14.4 | Typical Floor |
| 14.5 | Floors other than Typical Floor |
| 14.6 | Total |
| 14.7 | Total of all buildings |
| 15 | Dwelling Units | Numbers of Units | Total Unit Area (in sqm) | Details of unit area (Size) of Individual Unit (in sqm) | |
| Provide Details for individual Building |
| % Of Total Built-up Area |
| 19.4 | Visitors parking area provided at Ground Level (please specify in % as well as area) | % Of Total Built-up Area | ||||
| 20 | Parking | Area (in sq m) | No. of Parking spaces for 2-heelers | No. of Parking spacesfor4- wheelers | |||
| 20.1 | Proposed Parking on Ground Level (including Hollow Plinth) | |||||
| 20.2 | Proposed Parking on Basement Level | |||||
| 20.3 | Proposed Parking on levels above Hollow Plinth | |||||
| 20.4 | Covered Parking | |||||
| 20.5 | Open Parking | |||||
| 20.6 | Total | |||||
| Build-to-line |
| *Building-Unit (Plot) as mentioned in Local Area Plan, please provide the following details. |
| 1 | Length of Build-to-Line | In meters | |||||
| 2 | Length of Build-to-Line coinciding the front façade of the building | In meters | |||||
| 3 | Percentage of length of Build-to- line coinciding the front façade of the building | % | |||||
| Proposal Details |
I fully understand that in case my certificate is found to be false, or if it is found that the Direct Development Permission issued by me is inconsistent with the General Development Rules of the PDA shall be at liberty to penalize me.
Name of the AOR: ____
Registration No.: ____
Address: ____
Tele. No.: ____
Signature: ____
Date: ____
Application for Revising Development Permission for Building / Layout / Sub-division / Amalgamation
(Refer Rule No. 4.13.1, 4.13.3)
To,
The Competent Authority
Proposed Development:
(Title of the work)
Full Address of Proposed Development:
Name of the Owner / Developer: ____
Sir/ Madam,
I am the Owner / Developer of the building unit / plot and wish to undertake:
• Development on building unit
• Development of layout
• Subdivision of building unit
- Amalgamation of building unit
Dadra and Nagar Haveli Planning and Development Authority
The Development Permission No. ____ has been granted to me by the Competent Authority vide Letter No. ____ dated ____. I wish to vary the sanctioned layout / design & specifications of the proposed building. I shall be responsible for ensuring that the building complies with the General Development Rules.
I request that the Revised Development Permission be granted to me.
Name of the Owner/Developer: ____
Address: ____
Tel. No.: ____
Signature: ____
Date: ____
Page No 246
Page No 247
Application for Revalidating Direct Development Permission / Revised Direct Development Permission
(Refer Rule No. 4.14.1)
To,
The Competent Authority
File No: ____
Dated: ____
Proposed Development:
(Title of the work)
Full Address of Proposed Development:
Name of the Owner / Developer: ____
Sir,
I am currently listed as Architect on Record with the PDA and am fully conversant with the General Development Rules of PDA. I have been appointed as the Architect on Record of the proposed Development. The Direct Development Permission that was issued on ____ (date) by ______________ (name of the Architect on Record) has lapsed /suspended due to ______________.
I hereby certify that I have verified the design and specifications of the proposed Development and certify that they comply with the General Development Rules. I hereby issue a Revalidated Direct Development Permission for construction of the proposed development. This Revalidated Direct Development Permission is to be read in conjunction with all other documents and drawings which are enclosed as per the provisions of Rule No 4.14.1 and its Schedules, and that all such documents, drawings, and specifications form part of this Revalidated Direct Development Permission.
I fully understand that in case my certificate is found to be false, or if it is found that the Revalidated Direct Development Permission issued by me is inconsistent with the General Development Rules the PDA shall be at liberty to penalize me as per the provisions of the Act and Rules.
Name of the AOR: ____
Registration No.: ____
Address: ____
Tele. No.: ____
Signature: ____
Date: ____
- Any other (specify)
Following provisions are not as per the Development Rules
- FSI.
- Height
- Ventilation
- Open air space
- Provisions for Fire protection
- Any other (specify)
Application for Registering Revalidating Direct Development Permission / Revised Direct Development Permission
(Refer Rule No. 4.14.1)
To,
The Competent Authority
Proposed Development:
(Title of the work)
Full Address of Proposed Development: ____ ____
Name of the Owner / Developer: ____
Sir,
I am currently listed as Architect on Record with Competent Authority. I am fully conversant with the General Development Rules.
I have been appointed as the Architect on Record of the proposed development. This is to notify you that the Direct Development Permission issued on ____ (date) by ____ (name of the Architect on Record) had lapsed on ____ (date) due to ____.
I hereby certify that I have verified the design and specifications of the proposed Development and certify that they comply with the General Development Rules of the PDA.
I have issued a Revalidated Direct Development Permission for construction of the proposed Development and hereby apply for registering the same on the records of the Corporation. I fully understand that in case my certificate is found to be false, or if it is found that the Revalidated Direct Development Permission issued by me is inconsistent with the General Development Rules of PDA, the PDA shall be at liberty to penalize me as per the provisions of the Act and Rules.
Name of the AOR: ____
Registration No.: ____
Address: ____
Tele. No.: ____
Signature: ____
Date: ____
Page No 248
Page No 249
Application for Revalidating a Lapsed / Suspended Development Permission / Revised Development Permission
(Refer Rule No. 4.15.1)
To,
The Competent Authority
Proposed Development:
(Title of the work)
Plot No / Sub Plot No.: ____ Area of the Plot / Sub Plot: ____ (sq m)
Full Address of Proposed Development: ____ ____
Name of the Owner / Developer: ____
Sir/ Madam,
I am the Owner/Developer of the plot and wish to undertake construction of the proposed building on the building-unit.
The Development Permission has been granted to me by the Competent Authority vide Letter No. ____ dated. The Development Permission that was issued on (date) by the Competent Authority shall lapse on / has lapsed / suspended on ____(date) due to ____
I shall be responsible for ensuring that the building complies with the General Development Control Rules. I request that the Revalidated Development Permission be granted to me.
Name of the Owner/Developer: ____
Address: ____
Tel. No.: ____
Signature: ____
Date: ____
(Refer Rule No. 5.5.1)
To,
The Competent Authority
File No: ____
Dated: ____
Proposed Development:
(Title of the work)
Full Address of Proposed Development: ____ ____
Name of the Owner / Developer: ____
Sir/ Madam,
This is to notify you that the construction of the proposed building / development has commenced on ____(date). The construction of the building / development shall be undertaken in compliance with the sanctioned design & specifications and the General Development Rules.
Signature of Owner with date: ____
Dadra and Nagar Haveli Planning and Development Authority
Name: ____
Address: ____
Signature of Architect on Record with date: ____
Name: ____
Address: ____
Page No 250
Form No. 20 Notice for Progress of Construction
(Refer Rule No. 5.5.3, 6.6.3)
To
The Competent Authority
File No: ____
Dated: ____
Proposed Development:
(Title of the work)
Full Address of Proposed Development: ____ ____
Name of the Owner / Developer: ____
Sir/ Madam,
This is to notify you that the construction of the proposed building has reached the following stage:
No Stage Date
1 Plinth level
2 Ground Floor
3 Middle storey
4 Last storey
The construction of the building / development is in compliance with the sanctioned drawings and the General Development Rules. We declare that the amended plan is not necessary at this stage.
Name of AOR/EOR
Name of Clerk of Works:
Registration No.:
Registration No.:
Address:
Address:
Tel. No.:
Tel. No.:
Signature:
Date:
Signature:
Date:
Signature of Owner with date: ____
Name: ____
Address: ____
____
Page No 251
(Refer Rule No. 6.5.1, 6.6.3)
To
The Competent Authority
File No: ____
Dated: ____
Proposed Development for Temporary Construction:
(Title of the work)
Full Address of Proposed Development for Temporary Construction:
Name of the Owner / Developer: ____
Sir / Madam,
This is to notify you that the proposed temporary construction has been completed in compliance with the sanctioned drawings and the General Development Rules.
Enclosed with this application are:
1 Notice of Completion of Construction and Compliance Certification as prescribed in Form No. 21.
2 One set of Completion Plans and as-built drawings, duly certified by the POR.
3 Form No. 2: Certificates of Undertaking by the Architect on Record or Engineer on
4 Record; and form No. 2: Certificates of undertaking by the FPCOR
5 Form No. 2: Certificates of Undertaking by the Structural Engineer on Record,
6 Form No. 2: Certificates of Undertaking by the Clerk of Works on Record,
7 Clearance from Fire Officer, as applicable & mentioned in Schedule No. 4
8 A copy of valid Registration Certificate of the Persons on Record issued by the Competent Authority.
9 Certificate of lift Inspector (Government of UT) for high-rise buildings.
We request that the Occupancy Certificate be granted to the building. Any subsequent change from the completion drawings will be our responsibility.
Name of the Owner/Developer: ____
Address: ____
Tel. No.: ____
Signature: ____
Date: ____
Page No 254
Page No 255
(Refer Rule No. 6.5.1, 6.6.3)
To,
The Competent Authority
File No: ____
Dated: ____
Proposed Development:
(Title of the work)
Full Address of Proposed Development:
Name of the Owner / Developer: ____
Sir/ Madam,
This is to notify you that the construction of the proposed building / development has been completed under our supervision.
We hereby certify that the construction of the building has been undertaken in compliance with the sanctioned drawings and the General Development Rules. We declare that the building is to be used for purpose as per approved plan and it shall not be changed without obtaining written permission.
Any subsequent change from the completion drawings will be our responsibility.
Name of AOR/EOR
Name of SEOR
Registration No.:
Address:
Registration No.:
Tel. No.:
Address:
Signature:
Tel. No.:
Date:
Dadra and Nagar Haveli Planning and Development Authority
Date:
Signature of Owner with date: ____
Name: ____
Address: ____
____
Page No 252
Form No. 22A Application for Occupancy Certificate
(Refer Rule No. 6.5.1, 6.6.3)
To
The Competent Authority
File No: ____
Dated: ____
Proposed Development:
(Title of the work)
Full Address of Proposed Development:
Name of the Owner / Developer: ____
Sir / Madam,
This is to notify you that the proposed building(s)/ fully built (No. of building blocks) out of the proposed building blocks has been completed in compliance with the sanctioned drawings and the General Development Rules.
Enclosed with this application are:
1 Notice of Completion of Construction and Compliance Certification as prescribed in Form No. 21.
2 One set of Completion Plans and as-built drawings, duly certified by the POR.
3 Form No. 2: Certificates of Undertaking by the Architect on Record or Engineer on
4 Record; and form No. 2: Certificates of undertaking by the FPCOR
5 Form No. 2: Certificates of Undertaking by the Structural Engineer on Record,
6 Form No. 2: Certificates of Undertaking by the Clerk of Works on Record,
7 Clearance from Fire Officer, as applicable & mentioned in Schedule No. 4
8 A copy of valid Registration Certificate of the Persons on Record issued by the Competent Authority.
9 Certificate of lift Inspector (Government of UT) for high-rise buildings.
We request that the Occupancy Certificate be granted to the building. Any subsequent change from the completion drawings will be our responsibility.
Name of the Owner/Developer: ____
Address: ____
Page No 253
Tel. No.: ____
Signature: ____
Date: ____
Application for Development Permission for Building / Layout / Subdivision / Amalgamation
(Refer Rule No. 4.11.1)
Application for development permission under sections 44, 49 and 66 of The Dadra and Nagar Haveli and Daman & Diu Town & Country Planning Act, 1974, as the case may be.
To,
The Competent Authority
I / We hereby apply for permission for the following:
Development on building unit
Development of layout
Subdivision of building unit
Amalgamation of building unit
The information sheet is enclosed with this application. All drawings and documents as per Schedule No. 6A are enclosed with this application.
The names of the persons on record are as under:
a) The plans are prepared by Registered Architect / Civil Engineer:
(Please specify the license number and date of expiry)
b) The structural report, details and drawings are prepared and supplied by Registered Structural Engineer: (if Applicable) (Please Specify the license number and date of expiry)
c) The site supervision of the construction work will be done by Registered Clerk of Work: (if Applicable)
Dadra and Nagar Haveli Planning and Development Authority
(Please Specify the license number and date of expiry)
I shall be responsible for ensuring that the development complies with the Development Rules framed by the Competent Authority under the provisions of the Act. I shall fulfil my duties and responsibilities in accordance with the provisions of the Development Rules.
Signature of Owner / Developer or Authorized Agent of Owner Date:
Page No 228
Table No. F10A – 1: Information Sheet with Application for Development Permission for Building / Layout / Amalgamation / Subdivision
| No. | Title | Details | |||
| 1 | Ownership Details | ||||
| 1.1 | Applicant's Name | ||||
| 1.2 | Postal Address for correspondence | ||||
| 1.3 | Address of Land in Question | ||||
| 1.4 | Applicants interest / title in land with respect of record of rights | ||||
| 2 | Land Details - Legal | ||||
| 2.1 | Land Description | ||||
| 2.2 | Village Name | ||||
| 2.3 | TPS/Revenue village / Gamtal | ||||
| 2.4 | FP No/ Revenue Survey No./ C S No | ||||
| 2.5 | Sub-Plot No/Tenement No | ||||
| 2.6 | Ward | ||||
| 2.7 | Zone | ||||
| 2.8 | Details of Approval before taken | ||||
| 3 | Type of Case for Application | ||||
| 3.1 | New / Revision / Reopen / Renewal/ Addition/Alteration | ||||
| 4 | Land Occupancy Type Existing | Tick as applicable | Land Occupancy Type- Proposed | Tick as applicable | |
| 4.1 | Vacant | Vacant | |||
| 4.2 | Partly - Built | Partly - Built | |||
| 4.3 | Fully - Built | Fully - Built | |||
| 5 | Site Details | ||||
| A Width of Road Abutting the Site | TP Road | Non-TP Road/DP Road/Other Road | BRTS Corridor | ||
| 5.1 | Road 1: Front Side | ||||
| 5.2 | Road 2: Other than Front Side | ||||
| 5.3 | Road 3: Other than Front Side | ||||
| 5.4 | Road 4: Other than Front Side | ||||
| B Seismic Details | Yes/ No | Zone No. | Details | ||
| 5.5 | Seismic Zone | ||||
| C Water Supply | Available by Local Government/Authority | Bore Well | |||
| 5.6 | Water Supply Facility in Building-unit | ||||
| D Drainage | Available by Local Government/Authority | Not Available | |||
| 5.7 | Drainage Facility in Building- unit | ||||
| E Storm Water | City Network | Percolation Pit/ Percolating Well/ Recharge Pit | |||
| 5.8 | Storm Water Facility in Building-unit | ||||
| F Solid Waste Disposal | Local Government/Authority | None | |||
| 5.9 | Solid Waste Disposal Facility in Building-unit | ||||
| G Electricity | Available by Torrent/GEB/Other | None | |||
| 5.10 | Electricity facility in Building- unit | ||||
| 6 | Land-Use Details | ||||
Page No 229
| No. | Title | Details | |||||
| A Existing Use | Details | ||||||
| Use Sub-type | Total Units | Max. No of Floor | Max. Building Height. | Total Built- up Area | |||
| 6.1 | Residential | ||||||
| 6.2 | Commercial | ||||||
| 6.3 | Mixed Use | ||||||
| 6.4 | Industrial | ||||||
| 6.5 | Others (please specify) | ||||||
| B Proposed Use | Details | ||||||
| 6.6 | Residential | ||||||
| 6.7 | Commercial | ||||||
| 6.8 | Mixed Use | ||||||
| 6.9 | Industrial | ||||||
| 6.10 | Others (please specify) | ||||||
| Attachments: Annexure as above | |||||||
Page No 230
Form No. 10B
Application for Development Permission for Brick Kiln, Mining and Quarrying
(Refer Rule No. 4.11.1)
Application for permission of Brick‐kiln, Mining and Quarrying under Section 44 The Dadra and Nagar Haveli and Daman & Diu Town & Country Planning Act, 1974
To,
I/We hereby apply for permission for development as described below. I/We are applying for development on this land for the first time. I/We certify that all terms and conditions laid down in the development permission granted during last year/previous years have been scrupulous observed.
Table No. F10B – 1: Application for Development Permission for Brick Kiln, Mining and Quarrying
| No | Title | Details | |
| 1 | Ownership Details | ||
| 1.1 | Applicant's Name | ||
| 1.2 | Postal Address for correspondence | ||
| 1.3 | Address of Land in Question | ||
| 1.4 | Applicants interest/title in land with respect of record of rights | ||
| 2 | Land Details - Legal | ||
| 2.1 | Land Description | ||
| 2.2 | Village Name | ||
| 2.3 | TPS/ Revenue Village/ Gamtal | ||
| 2.4 | FP No/ Revenue Survey No./ C S No | ||
| 2.5 | Sub-Plot No/Tenement No | ||
| 2.6 | Details of 1/14 attached | ||
| 2.7 | Ward | ||
| 2.8 | Zone as per sanctioned DP | ||
| 2.9 | Details of Approval before taken. | ||
| 3 | Was land in question used for brick-kiln/mining/quarrying in the past? | ||
| 3.1 | Yes/ No | If YES, please specify details | |
| 4 | Whether Development Permission and N.A. permission were obtained in past? | ||
| 4.1 | Yes/ No | If YES, please specify details | |
| 5 | Total area of land in question: | ||
| 6 | Present Use of Land: | ||
| 7 | Proposed Use of Land: | ||
| 8 | Mention the area of land used for above mentioned uses so far (sq m) Indicate the same on-site plan | ||
| 9 | Mention the proposed area to be used. (sqm) Indicate the same on-site plan | ||
| 10 | Mention the duration for which permission is sought (in month / year) | ||
| 10.1 | Mention time-limit for completion or termination of such use (in month / year) | ||
(Refer Rule No. 6.5.3)
To
(Name of person)
Proposed Development:
(Title of the work)
Full Address of Proposed Development:
Name of the Owner / Developer: ____
With reference to your Application No: ____ dated: ____ I am directed to inform you that the building unit has been inspected on date: ____ and the development is as per sanctioned design and specifications; and that Occupancy Certificate has been granted. The building / part of building may be used as per sanctioned drawings. This Occupancy Certificate is to be read in conjunction with all other documents and drawings which are enclosed as per the provisions of Rule No 7 and its Schedules, and that all such documents, drawings, and specifications form part of this Occupancy Certificate
OR
With reference to your Application No: ____ dated: ____ I am directed to inform you that the building-unit has been inspected on date ____ and that a Occupancy Certificate has not been granted on the following grounds:
Yours faithfully
For,
The Competent Authority
Form No. 24 Cancellation of Occupancy Certificate
(Refer Rule No. 6.3)
To ____ ____
File No: ____
Dated: ____
Proposed development:
(Title of the work)
Plot No.: Area of the Plot:
Address and location of proposed development:
Sir,
This is to notify you that the Occupancy Certificate No. ____ issued or granted on date: ____ by ____ (name of the Architect on Record)/ MS PDA/ Chief Executive Authority has been revoked by the MS PDA / Chief Executive Authority on the following grounds:
Please note that no further use may be made of the development. A new Occupancy Certificate has to be obtained before making use of the development.
For,
The Competent Authority
Page No 256
Change in the Sanctioned Occupancy of Building / Development
Page No 257
General Development Rules- Part 3(I), 2023
Form No. 25
(Refer Rule No. 6.6.1, 6.6.3)
To
The Competent Authority
Proposed Development:
(Title of the work)
Full Address of Proposed Development:
Name of the Owner / Developer: ____
Sir,
I am the Owner of the development to which the Occupancy Certificate has been granted by the MS PDA / Chief Officer vide Letter No. ____ dated ____. I wish to change the Sanctioned Use of the Development to a new use as specified below:
(Description of the new use to which the Development is proposed to be put to)
I shall be responsible for ensuring that the new use of the Development complies with the General Development Control Rules.
We hereby certify that in case the new use results in the Development being re-classified to a Higher Importance Factor (as defined in the IS: 1893-2002 "Criteria for Earthquake Resistant Design Structures - Fifth Revision)", the Development shall conform to seismic requirements for the Development with the Higher Importance Factor.
I request that the Permission to Change Sanctioned Use of the Development be granted.
Name of the Owner: ____
Address: ____
Tele. No.: ____
Signature: ____
Date: ____
Name of the SEOR: ____
Registration No.: ____
Address: ____
Tele. No.: ____
Signature: ____
Date: ____
(Maintenance of Building –Schedule No. 10)
(This form has to be completed by registered Structural Engineer on Record after his / her site inspection and verification regarding compliance of all recommendation by the owner, which in the opinion of the registered Structural Engineer on Record is necessary for safety of the structure)
Table No. F26-1: Details of Structural Inspection Report (Part 1)
| No | Description | Information | Notes | |
| 1 | Title, Location and Address of the building including T.P.No, F.P. No, etc | |||
| 2 | Name of Present Owner | |||
| 3 | Name of Structural Engineer on Record | |||
| 4 | Use of the building | |||
| 5 | Year of construction | |||
| Year of subsequent additions | ||||
| Nature of additions or alterations | ||||
| 6 | Date of Last Inspection Report | |||
| SEOR for Last Inspection Report | ||||
| 7 | Class1 -Building | |||
| 8 | Class2 -Building | |||
| 9 | Type of structure | |||
| i) | Load bearing walls | |||
| ii) | R.C.C frame | |||
| iii) | R.C.C frame and Shear walls | |||
| iv) | Steel Frame | |||
| 10 | Soil data | IS:1893Cl.6.3. 5.2IS:1904 | ||
| i) | Type of soil | |||
| ii) | Design safe bearing capacity | |||
| iii) | Any change subsequent to construction | |||
| iv) | Any open excavation pit | |||
| v) | Any water body nearby | |||
| vi) | Proximity of drain | |||
| vii) | Underground water tank | |||
| viii) | Outlets of rainwater pipes | |||
| ix) | Settlements | |||
Page No 258
Table No. F26 – 2: Details of Structural Inspection Report (Part 2)
| 11 | For Renewal of Permission | ||
| 11.1 | Case No. and Date of previous Permission |
| 11.2 | Amount of the Security Deposit |
| Attachments: Annexure as above |
Signature of Owner/Developer or Authorized agent of owner: Date:
Page No 231
| (a) Function | (b) Framed construction | |||||||
| Residence (with or without shops) | Apartments (with or Without shops) | Office Bldg. | Shopping center | School, College | Hostel | Auditoria | Factory | |
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
| A. Load bearing masonry wall construction | ||||||||
| Framed structure | ||||||||
| Construction and structural materials | Critical load bearing element | Brick | RCC | Stone | Timber | Steel | ||
| Roof Floor | RCC | Timber | RBC | Steel | Jack- arch | |||
Table No. F26 – 3: Details of Structural Inspection Report (Part 3)
| Part 1 Load bearing masonry buildings | |||
| Description | Information | Notes | |
| 1 | Building category | ||
| 2 | Any cracks in masonry walls | ||
| Extent of cracks | |||
| Location of cracks | |||
| Sketch of cracks, if necessary | |||
| 3 | Recommendations, if any | ||
| Part 2 Reinforced Concrete framed buildings | |||
| Description | Information | Notes | |
| 1 | Type of Building | ||
| 2 | Any cracks in beams | ||
| Extent of cracks | |||
| Probable causes | |||
| 3 | Any cracks in columns | ||
| Extent of cracks | |||
| Probable causes | |||
| 4 | Any cracks in slab | ||
| Extent of cracks | |||
| Probable causes | |||
| Spilling of concrete or plaster of slab | |||
| Corrosion of Reinforcement | |||
| 5 | Cover Spell | ||
| Part 3 Reinforced Concrete framed buildings | |||
| Description | Information | Notes | |
| 6 | Exposure of reinforcement | ||
| 7 | Subsequent damage by user for taking pipes, conduits, | ||
Page No 259
| hanging fans or any other fixtures, etc. | |||
| 8 | Loads in excess of design loads | ||
| 9 | Recommendations, if any | ||
| Part 4 Buildings in Structural Steel | |||
| Description | Information | Notes | |
| 1 | Building category | ||
| 2 | Painting | ||
| 3 | Corrosion | ||
| 4 | Joints, nuts, bolts, rivets, welds, gusset plates | ||
| 5 | Bending or buckling of members | ||
| 6 | Base plate connections with columns of pedestal | ||
| 7 | Loads in excess of design loads | ||
| 8 | Recommendations, if any | ||
This is to certify that the above is a correct representation of facts as given to me by the owner and as determined by me after Site Inspection to the best of my ability and judgment.
The recommendations made by me to ensure adequate safety of the structure are compiled with by the owner to my entire satisfaction.
Name of the SEOR: ____
Registration No.: ____
Address: ____
Tel. No.: ____
Signature: ____
Date: ____
Page No 260
Form No. 27 Fire Safety Certificate
(Refer Rules, Schedule No. 10)
To
The Competent Authority
Existing Building:
Survey No.:
Block No.:
City Survey No.:
Final Plot No.:
Sub Plot / Property No.:
Address and location of existing building:
Name of Owner: Type of Structure:
Sir / Madam,
I am currently registered as Fire Protection Consultant on Record for the above building.
This is to notify that I have inspected the above building on date ____ and to the best of my knowledge; I certify that the fire safety of the building has not been compromised due to lack of maintenance.
Name of the FPCOR: ____
Registration No.: ____
Address: ____
Tel. No.: ____
Signature: ____
Page No 261
Date: ____