21.1 Applicability
The quality control and inspection shall apply to all high-rise residential building and all non-residential buildings.
The owner / developer / occupants and registered appointed Person on Record shall have to certify the inspection and safety report as per Schedule No. 3.
Page No 164
Schedules & Forms
Page No 165
Page No 166
| No. | Schedules |
|---|---|
| 1 | Minimum Qualification, Experience and Document Requirements for being considered for Registering with the Competent Authority as Persons on Record |
| 2 | Procedures for Ascertaining Whether a Person on Record has failed in Discharging his Responsibilities and Penalties |
| 3 | Technical Audit Report |
| 4 | Buildings requiring Fire Protection Consultant on Record and Inspection by Fire Officer |
| 5A | Fees and Charges for Grant of a Development Permission / Revised Development Permission / Revalidation of Development Permission |
| 5B | Fees and Charges for Grant of Occupancy Certificate / Change of Occupancy Certificate |
| 5C | Fees for Temporary Construction |
| 5D | Penalties |
| 6A | Drawings, Specifications and Documents to be Submitted with Application for Obtaining / Revising Development Permission for Building and for Sub- division & Amalgamation of Building Unit / Plot |
| 6B | Drawings, Specifications and Documents to be Submitted with Application for Obtaining / Revising / Revalidating Development Permission for Brick Kiln, Mining and Quarrying |
| 6C | Format for submission of Documents, Drawings and Specifications |
| 6D | Drawing, Specification and Documents to be Submitted with Application for Obtaining Permission for Temporary Construction |
| 7A | Information to be Displayed on Site |
| 7B | Documents and Drawings to be Maintained on Site During Period of Construction |
| 7C | Stages of Construction Work for which Notice for Progress of Construction to be Submitted to the Competent Authority |
| 8 | Inspection Requirements |
| 9 | Documents and Drawings to be Submitted along with the Application for Occupancy Certificate |
| 10 | Schedule for Maintenance and Inspection for Structural Stability and Fire Safety |
| 11 | Documents and Fees Required with Application for Advertising Display & Communication Infrastructures |
| 12 | List of Recommended Trees |
| 13 | Standalone Multi-Level Public Parking |
Page No 167
Page No 168
Forms:
| No. | Forms |
|---|---|
| 1 | Application for Registering as Person on Record |
| 2 | Certificate of Undertaking for Persons on Record |
| 3 | Notice to the Competent Authority of Non-Compliance of Building to Sanctioned Design and Specifications |
| 4 | Notice to the Competent Authority of Discontinuation as Person on Record |
| 5 | Notice of Cancellation of Development Permission |
| 6 | Notice to Stop Unauthorized Development |
| 7 | Direct Development Permission |
| 8 | Application for Registering Issue of Direct Development Permission |
| 9 | Registration or Cancellation of Direct Development Permission / Revised Direct Development Permission / Revalidated Direct Development Permission |
| 10A | Application for Development Permission for Building / Layout / Subdivision / Amalgamation |
| 10B | Application for Development Permission for Brick Kiln, Mining and Quarrying |
| 10C | Application for Development Permission for Temporary Construction |
| 11A | Area Statement for Buildings |
| 11B | Area Statement for Subdivision / Amalgamation / Layout of Land |
| 11C | Area Statement for Temporary Construction |
| 12 | Grant / Refusal of Development Permission / Revised Development Permission / Revalidated Development Permission |
| 13 | Application for Revised Direct Development Permission |
| 14 | Application for Registering Issue of Revised Direct Development Permission |
| 15 | Application for Revising Development Permission for Building / Layout / Sub - division / Amalgamation |
| 16 | Application for Revalidating Direct Development Permission / Revised Direct Development Permission |
| 17 | Application for Registering Revalidated Direct Development Permission / Revised Direct Development Permission |
| 18 | Application for Revalidating a Lapsed / Suspended Development Permission / Revised Development Permission |
| 19 | Notice for Commencement of Construction |
| 20 | Notice for Progress of Construction |
| 21 | Notice for Completion and Compliance Certification |
| 22A | Application for Occupancy Certificate |
Page No 169
Page No 170
Tables
| Table No. S1-1 | SEOR Qualification and Experience |
|---|---|
| Table No. S1-2 | COWOR Qualification and Experience |
| Table No. S1-3 | SOR Qualification and Experience |
| Table No. S2-1 | Penalties for Person on Record |
| Table No. S3-1 | Details of Technical Audit Report |
| Table No. S4-1 | (Deleted) |
| Table No. S5A-1 | Scrutiny Fees for Buildings |
| Table No. S5A-2 | Fees for Subdivision/ Amalgamation / Layout of Building Unit / Plot |
| Table No. S5A-3 | Charges for Change of Land Use |
| Table No. S5A-4 | Development Charges for Buildings |
| Table No. S5A-5 | Charges for Stacking Building Material on Public Roads |
| Table No. S5B-1 | Fees for Occupancy Certificate |
| Table No. S5B-2 | Fees for Change of Occupancy |
| Table No. S5C-1 | Fees for Applying for Temporary Construction |
| Table No. S5D-1 | Penalties for Unauthorized Construction and Occupancy |
| Table No. S5D-2 | Penalties Applicable for Regularizing Unauthorised Construction for Residential Use |
| Table No. S6C-1 | Drawing Sizes |
| Table No. S6C-2 | Colours and Notations for Drawings and Documents |
| Table No. S8A-1 | Principles of Risk Categorization (Definition of Consequence Class) and Inspection Requirements |
| Table No. S12-1 | List of Trees |
| Table No. F10A-1 | Information Sheet with Application for Development Permission for Building / Layout / Amalgamation/ Subdivision |
| Table No. F10B-1 | Application for Development Permission for Brick Kiln, Mining and Quarrying |
| Table No. F10C-1 | Information Sheet with Application for Development Permission for Temporary Construction |
| Table No. F11A-1 | Area Statement for Buildings |
| Table No. F11B-1 | Area Statement for Subdivision / Amalgamation / Layout of Land |
| Table No. F11C-1 | Area Statement for Temporary Construction |
| Table No. F26-1 | Details of Structural Inspection Report (Part 1) |
| Table No. F26-2 | Details of Structural Inspection Report (Part 2) |
| Table No. F26-3 |
Page No 171
Page No 172
Schedule
Page No 173
Minimum Qualification, Experience and Document Requirements for being considered for Registering with the Competent Authority as Persons on Record
(Refer Rule No. 3.2.1, 3.2.2, 3.2.3)
The procedure for registering persons with the Competent Authority is given in Rule No. 3.2.1. The registration shall be renewed annually. The following are the minimum qualifications and experience requirements for all persons to be considered for registering with the Competent Authority as Persons on Record, in order to determine their competence to fulfil their responsibilities as specified in Rule No. 3.2.2.
Minimum qualifications and experience requirements for architects, for being considered for registration with the Competent Authority, as Architects on Record shall be as follows:
(a) Architect must hold a valid registration with the Council of Architecture, India, issued as per the provisions of the Architects Act, 1972 or Bachelor’s Degree in Architecture / Diploma in Architecture Equivalent to B. Arch; and
(b) Architect must have a minimum of two years of experience in practice of architecture.
B Scope Work and Competence:
(a) Preparation & planning of all types of layouts; submission of drawings; submission of certificate of supervision, progress reports and submission of certificate of completion for all types of buildings in accordance with the provisions of these building Rules.
(b) Supervision & execution of construction work as per specifications & drawings prepared by authorised registered structural designer & engineer.
Minimum qualifications and experience requirements for engineers, for being considered for registration with the Competent Authority, as Engineers on Record shall be as follows:
(a) Master’s Degree in Civil Engineering, a bachelor’s degree in Civil Engineering or Building construction or its equivalent qualification recognized by the All-India Board of Technical Education, or, a Diploma in Civil Engineering or Diploma in Building Construction recognized by State Board of Technical Examination of any State of India or Associate Membership (Civil Engineering) of the Institute of Engineers, India (AMIE), and
(b) Engineer having bachelor’s degree, or its equivalent qualification must have minimum of two years of experience and Diploma holder/or AMIE must have minimum of five years of experience in professional work.
(a) Preparation & planning of all types of layouts except special structures / special buildings as per these Rules; submission of drawings and submission of certificate of supervision & completion for all types of buildings. A person having qualification of a Diploma in Civil Engineering shall be permitted to undertake low rise buildings only.
Page No 174
(b) Supervision & execution of construction work as per specifications & drawings prepared by authorized registered structural designer.
(c) He / she can prepare & submit structural details & calculations for buildings of load bearing structures.
Minimum qualifications and experience requirements for structural engineers, for being considered for registration with the Competent Authority as Structural Engineer on Record shall be as follows:
Table No. S1 – 1: SEOR Qualifications and Experience
| Grade | Scope of Work | Qualification | Minimum Years of Experience* |
| SEOR 1 | 1 Building with height above 25 m 2 Total proposed built-up area for a building unit is more than10000 sqm 3 Mercantile - 2, 3; Educational -1, 2, 3; Assembly - 1, 2, 3; Health - 2, 3, 4; Hospitality - 2, 3, Utility; Public Office; Special Buildings | Category 1 | 10 |
| Category 2 | 3 | ||
| SEOR 2 | 1 Building with height above 15 m /17.5 m (with Stilt) and up to 25 m 2 Total proposed built-up area for a building unit is more than 2000 sqm and up to 10000 sqm | Category 1 | 5 |
| Category 2 | 2 | ||
| SEOR 3 | 1 Building with height up to 15 m /17.5 m (with Stilt). 2 Total proposed built-up area for building unit up to 2000 sqm | Category 1 | 2 |
| Category 2 | ----- | ||
| Notes: 1 *Minimum years of experience of preparing structural design, detailed drawings, and specifications after attaining the degree/ Diploma. 2 Category 1: B.E/ B. Tech Civil or equivalent degree recognized by the AICTE. 3 Category 2: M.E/ M. Tech Civil, or a Ph. D in Structural Engineering. 4 Person holding Higher grade license can also work for Lower Grade Work | |||
Minimum qualifications and experience requirements for construction engineers, for being considered for registration with the Competent Authority as Clerk of Works on Record qualified for certifying the construction of buildings shall be as follows:
Table No. S1 – 2: COWOR Qualifications and Experience
| Grade | Scope of Work | Qualification | Minimum Years of Experience* |
| COWOR 1 | 1 Building with height above 25 m 2 Total proposed built-up area for a building unit is | Category 1 | 3 |
| Category 2 | 5 |
Page No 175
| Grade | Scope of Work | Qualification | Minimum Years of Experience* |
| more than 10000 sqm. 3 Mercantile - 2, 3; Educational -1, 2, 3; Assembly - 1, 2, 3; Health - 2, 3, 4; Hospitality - 2, 3; Utility; Public Office; Special Buildings | Category 3 | 3 | |
| COWOR 2 | 1 Building with height above 15 m /17.5 m (with Stilt) and up to 25 m. 2 Total proposed built-up area for a building unit is more than 2000 sqm and up to 10000 sqm. | Category 1 | 2 |
| Category 2 | 4 | ||
| Category 3 | 2 | ||
| COWOR 3 | 1 Building with height up to 15 m /17.5 m (with Stilt). 2 Total proposed built-up area for building-unit up to 2000 sqm | Category 1 | 1 |
| Category 2 | 2 | ||
| Category 3 | 1 | ||
| Notes: 1 *Minimum years of experience (after attaining the degree/ Diploma) in Construction work at a responsible position in any organization 2 Category 1: A Degree in Civil Engineering / Architecture or Diploma in Architecture equivalent to degree Architecture, or its equivalent qualification recognized by All India Board of Technical Education 3 Category 2: Diploma in Civil Engineering recognized by State Board of Technical Examinations of any State in India 4 Category 3: Bachelor's Degree with specialized training in building in construction technology or Diploma in Building Construction Technology from a recognized institute. 5 Person holding Higher grade license can also work for Lower Grade Work | |||
Minimum qualifications and experience requirements for construction engineers, for being considered for registration with the Competent Authority as Supervisor of Works on Record qualified for certifying the construction of buildings shall be as follows:
Table No. S1 – 3: SOR Qualifications and Experience
| Grade | Scope of Work | Qualification | Minimum Years of Experience* |
| SOR 1 | 1 Building with height above 25 m 2 Total proposed built-up area for a building unit is more than 10000 sqm 3 Mercantile - 2, 3; Educational -1, 2, 3; Assembly - 1, 2, 3; Health - 2, 3, 4; Hospitality - 2, 3; Utility; Public Office; Special Buildings | Category 1 | 3 |
| Category 2 | 5 | ||
| Category 3 | 3 | ||
| SOR 2 | 1 Building with height above 15 m /17.5 (with Stilt) m and up to 25 m 2 Total proposed built-up area for a building unit is more than 2000 sqm and up to 10000 sqm | Category 1 | 2 |
| Category 2 | 4 | ||
| Category 3 | 2 | ||
| SOR 3 | 1 Building with height up to 15 m /17.5 (with Stilt) m 2 Total proposed built-up area for building-unit up to 2000 | Category 1 | 1 |
| Category 2 | 2 |
Page No 176
| Grade | Scope of Work | Qualification | Minimum Years of Experience* |
| sqm | Category 3 | 1 | |
| SOR 4 | 1 Building with height up to 10 m 2 Total proposed built-up area for building-unit up to 200 sq m | Category 1 | 0 |
| Category 2 | 1 | ||
| Note: 1 *Minimum years of experience (after attaining the degree/ Diploma) in Construction work at a responsible position in any organization 2 Category 1: A Degree in Civil Engineering / Architecture or Diploma in Architecture equivalent to degree Architecture, or its equivalent qualification recognized by All India Board of Technical Education 3 Category 2: Diploma in Civil Engineering recognized by State Board of Technical Examinations of any State in India 4 Category 3: Bachelor's Degree with specialized training in building in construction technology or Diploma in Building Construction Technology from a recognized institute. 5 Person holding Higher grade license can also work for Lower Grade Work | |||
| 22B | Application for Occupancy of Temporary Construction |
| 23 | Grant / Refusal of Occupancy Certificate |
| 24 | Cancellation of Occupancy Certificate |
| 25 | Change in the Sanctioned Occupancy of Building / Development |
| 26 | Structural Inspection Report |
| 27 | Fire Safety Certificate |
| Details of Structural Inspection Report (Part 3) |
Page No 177