| III. | Urinals | - | - | 1 for 1 to 202 for 21to 453 for 46to 704 for 71to 100 | - | 1 per -50 |
|---|
PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021
(BHDR 19, 1943 SAKA)
| Serial Number | Fixtures | Shop Owners | Common toilets in market building | public toilet for floating population | |||
| Males | Females | Males | Females | Males | Females | ||
| IV. | Wash Basins | 1 per 8 or part thereof | 1 for up to 152 for 16 to 353 for 36 to 654 for 66 to 100 | 1 for up to 122 for 13 to 253 for 26 to 404 for 41 to 57 | - | - | |
| V. | Bath or showers | 1 per 8 or part thereof | 1 per 6 or part thereof | - | - | 1 per 50 persons | 1 per 50 persons |
Notes :-
(a) Toilet facilities for individual buildings in a market should be taken same as that for office buildings.
(b) Common toilets in the market buildings provide facilities for persons working in shops and their regular visitors.
(c) Special toilet facilities for a large floating population of out-of-town buyers/ sellers, labour, drivers of vehicles for whom special toilet (public toilets).
Bus Stations, Airports and Railway Stations
| Serial Number | Fixtures | Junction Stations, Intermediate Stations and Bus Stations | Terminal Railway and Bus Stations | Domestic and International Airports | |||
| Males | Females | Males | Females | Males | Females | ||
| I. | Water | 3 for | 4 for | 4 for | 5 for | for | for |
| Closets | up to | up to | up to | up to | 200: 5 | 200: 8 | |
| 1000 | 1000 | 1000 | 1000 | for | for | ||
| add 1 | add 1 | add 1 | add 1 | 400: 9 | 400: 15 | ||
| per | per | per | per | for | for | ||
| additio- nal | additio- nal | additio- nal | additio- nal | 600:12 | 600:20 | ||
| 1000 | 1000 | 1000 | 1000 | for | for | ||
| or part thereof | or part thereof | or part thereof | or part thereof | 800:16 | 800:26 | ||
| for | for | ||||||
| 1000: 18 | 1000: 29 | ||||||
2426 PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA)
| Serial Number | Fixtures | Junction Stations, Intermediate Stations and Bus Stations | Terminal Railway and Bus Stations | Domestic and International Airports | |
| Males Females | Males Females | Males Females | |||
| II. | Ablution tab | 1 in each water closet | |||
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals | |||||
| III. | Urinals | 4 for - to up 1000 add 1 per additional 1000 | 6 for up to 1000 add 1 per additional 1000 | 1 per - 40 or part thereof | |
| IV. | Wash Basins | 1 per WC | |||
| V. | Bath or showers | 2 per 1000 or part thereof | 3 per 1000 or part thereof | 4 per 1000 or part thereof | |
| VI. | Drinking Water Fountain or taps (in common lobby for male/female) | 2 per 1000 or part thereof | 3 per 1000 or part thereof | 4 per 1000 or part thereof | |
| VII. | Cleaner's sink | 1 per toilet compartment with 3 WCs | |||
Notes :-
(a) Some Water Closets (WC) may be Indian style, if desired.
(b) Male population may be assumed as three-fifth and female population as two-fifth.
(c) Separate provision shall be made for staff and workers.
Section 108 (2)
Section 108 (2)
Section 108 (2)
Section 108 (2)
31
2427
Section 35 108 (2)