(a) Open Ramps with minimum width of 6m may also be provided in the setbacks which can be sloped considering unhindered movement of fire engine and in no case, the gradient shall be less than 1:10.
(b) The ramp to basement and parking floors shall not be less than 7.2 m wide for two way traffic and 4 m wide for one way traffic, provided with gradient of 1:8 for cars and 1:15 for heavy vehicles. At curved portions of the ramp or for circular ramps, the slope should not be more than 1:12.
(c) After a 40 m length of continuous ramp, a flat surface of minimum 6.0 m length shall be provided.
(d) All and structural design or safety aspects as per latest Bureau of Indian Standard Codes and the National Building Code of India, 2016 shall be complied along with consideration of weight of Fire Engine and its maneuverings.
(13) Exit Requirements.- In respect of width and travel distance, all aspects of exit requirements for corridors, doors, staircases, ramps shall be as per Part 4- Fire and Life Safety of the National Building Code of India, 2016.
(14) Roofs.- (i) The roof of a building shall be so designed and constructed as to effectively drain water by means of sufficient rain water pipes of size as specified in the National Building Code of India, 2016, as amended from time to time wherever required, so arranged, jointed and fixed as to ensure that the rain water is carried away from the building without causing dampness in any part of the walls, roof or foundations of the building or an adjacent building.
(ii) The rain water pipes shall be connected to a drain or a sewer which connects the rain-water pipe to the road gutter or in any other approved manner.
(iii) The rain-water pipes shall be affixed to the outside of the external walls of the building or in recesses or chases cut or formed in such external walls or in such other manner as may be approved by the Authority.
(iv) It is desirable to conserve rain water using suitable rain water harvesting techniques including by roof water collection. For this purpose, the provisions made in Part 9- Plumbing Services (including Solid Waste Management), Section 2 Drainage and Sanitation of the National Building Code of India, 2016 shall be followed.
(15) Sunken courtyard.- Sunken courtyard up to 3 m in depth from the ground level and minimum 2 m width and minimum 10 sq.m. area as ‘light well’ within zoned area shall be permitted for light and ventilation for basement area provided that it does not interfere with the movement of fire tenders and adequate arrangements for drainage shall be provided.
However, for plot size upto 2025 sq.m area, sunken courtyard may be allowed upto the boundary wall of the plot in rear courtyard subject to the fulfillment of parking and fire tender movement as required.
(16) Fitments for drainage and sanitation.- (i) For Residences.- Dwelling with individual convenience shall have at least the following fitments, namely:-
(a) one bath room provided with a tap and a floor trap;
(b) one water closet with flushing apparatus with an ablution tap or health faucet; and
(c) one tap with a floor trap or a sink in kitchen.
(ii) The requirements for fitments for drainage and sanitation in the case of buildings other than residences shall be in accordance with Tables as below.
Office Building
| Serial Fixtures | Public Toilets | Staff Toilets | |||
| Number | Male | Female | Male | Female | |
| Executive Rooms and Conference Halls in Office Buildings | |||||
| I. | Toilet suite comprising one Water Closets (WC), one wash basin (with optional shower stall if building is used round the clock at user's option) | Unit could be common for male/female or separate depending on the number of user of each facility | For individual officer rooms | ||
| Pantry optional as per user requirement | |||||
| Main Office Toilets for Staff and Visitors | |||||
| II. | Water Closets (WC) | 1 per 25 | 1 per 15 | ||
| III. | Ablution tab with each water closet | 1 in each water closet | |||
| IV. | Urinals | Nil up to 6 | - | ||
| see note | see note | 1 for 7 to 20 | |||
| 2 for 21 to 45 | |||||
| 3 for 46 to 70 | |||||
| 4 for 71 to 100 | |||||
| From 101 to 200, add @ 3 percent; for over 200, add @ 2.5 percent | |||||
| V. | Wash Basins | 25 | 25 | ||
| VI. | Drinking Water Fountain | 1 per 100 persons | |||
| VII. | Cleaner's sink | 1 per floor | |||
Note:- Staff and public toilet utilities are generally common in office buildings. Where public toilets are to be provided separately, similar requirements as that of staff toilet may be provided.
2412 PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA)
Cinema, Multiplex Cinema, Concert and Convention Halls, Theatres and Stadia
| Serial Fixtures | Public Toilets | Staff Toilets | |||
| Number | Male | Female | Male | Female | |
| I. | Water Closets | 1 per 100up to 400;Over 400add at 1per 250or partthereof | 3 per 100up to 200;Over 200add at 2per 100or partthereof | 1 for upto 152 for 16to 35 | 1 for upto 122 for 13to 25 |
| II. | Ablution tab | 1 in each water closet1 water tap with draining arrangements shall be provided forevery 50 persons or part thereof in the vicinity of water closetsand urinals | |||
| III. | Urinals | 1 per 25or partthereof | - | 1 for 1 to 202 for 21 to45 | - |
| IV. | Wash Basins | 1 per 200 or partthereof | 1 for upto152 for 16to 35 | 1 for upto122 for 13 to25 | |
| V. | Drinking Water Fountain | 1 per 100 | |||
| VI. | Cleaner's sink | 1 per floor | |||
| VII. | Showers/bathing rooms | As per trade requirements | |||
Notes :-
(a) Some Water Closets (WC) may be Indian style, if desired.
(b) Male population may be assumed as two-third and female population as one-third.
| Art Galleries, Libraries and Museums | |||||
| Serial Number | Fixtures | Public Toilets | Staff Toilets | ||
| Male | Female | Male | Female | ||
| I. | Water Closets | 1 per 200up to 400;Over 400add at 1per 250or partthereof | 1 per 100up to 200;Over 200add at 1per 150or partthereof | 1 for upto 152 for 16to 35 | 1 for upto 122 for 13to 25 |
| II. | Ablution tab | 1 in each water closet1 water tap with draining arrangements shall be provided forevery 50 persons or part thereof in the vicinity of water closetsand urinals | |||
| III. | Urinals | 1 per 25or partthereof | - | 1 for 1 to 202 for 21to 45 | - |
| IV. | Wash Basins | 1 per 200up to 400;Over 400add at 1per 250or partthereof | 1 per 100up to 200;Over 200add at 1per 150or partthereof | 1 for upto 152 for 16to 35 | 1 for upto 122 for 13to 25 |
| V. | Drinking Water Fountain | 1 per 100 | |||
| VI. | Cleaner's sink | 1 per floor | |||
| VII. | Showers/bathing rooms | As per trade requirements | |||
Notes :-
(a) Some Water Closets (WC) may be Indian style, if desired.
(b) Male population may be assumed as two-third and female population as one-third.
2414 PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA)
| Restaurants | |||||
| Serial | Fixtures | Public Toilets | Staff Toilets | ||
| Number | Male | Female | Male | Female | |
| I. | Water Closets | 1 per 50 seats up to 200; Over 200 add at 1per 100 or part thereof | 2 per 50 seats up to 200; Over 200 add at 1 per 100 or part thereof | 1 for up to 15 2 for 16 to 35 3 for 36 to 65 4 for 66 to 100 | 1 for up to 12 2 for 13 to 25 3 for 26 to 40 4 for 41 to 57 5 for 58 to 77 6 for 78 to 100 |
| II. | Ablution tab | 1 in each water closet1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals | |||
| III. | Urinals | 1 per 50 persons or part thereof | - | 1 for 1 to 20 2 for 21 to 45 3 for 46 to 65 4 for 66 to 100 | - |
| IV. | Wash Basins | 1 per Water Closets (WC) | 1 per Water Closets (WC) | 1 per Water Closets (WC) | 1 per Water Closets (WC) |
| V. | Cleaner's sink | 1 per restaurant | |||
| VI. | Kitchen sink/dish washer | 1 per kitchen | |||
Notes :-
(a) Some Water Closets (WC) may be Indian style, if desired.
(b) Male population may be assumed as two-third and female population as one-third.
(c) Provision for additional and special fittings where required shall be made.
Notes :-
PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 2415 (BHDR 19, 1943 SAKA)
| Shopping Malls and Retail Buildings | |||||
| Serial Number | Fixtures | Public Toilets for floating population | Staff Toilets in Shopping Building | ||
| Male | Female | Male | Female | ||
| I. | Water Closets | 1 per 50(min. 2) | 1 per 50(min. 2) | 1 for up to 152 for 16 to 353 for 36 to 654 for 66 to 100 | 1 for up to 122 for 13 to 253 for 26 to 404 for 41 to 575 for 58 to 776 for 78 to 100 |
| II. | Ablution tab | 1 in each water closet | |||
| III. | Urinals | 1 per 50 | - | 1 for 1 to 202 for 21 to 453 for 46 to 654 for 66 to 100 | - |
| IV. | Wash Basins | 1 perWaterClosets(WC) | 1 perWaterClosets(WC) | 1 perWaterClosets(WC) | 1 perWaterClosets(WC) |
| V. | Cleaner's sink | 1 per floor | |||
| VI. | Bath/showers | 1 per 100 persons | |||
(a) Toilet facilities for individual facilities in a shopping building should be taken same as that for office buildings.
(b) Staff toilets in the shopping buildings provide facilities for persons working in shops and building, as well as for maintenance staff.
(c) The number of persons against the fixture bath/showers represent the maintenance staff requiring such facility.
(d) Public toilet facilities are provided for a large floating population for buyers and visitors.
(e) Some Water Closets (WC) may be Indian style, if desired.
(f) Male population may be assumed as two-third and female population as one-third.
(g) Provision for additional and special fittings where required shall be made.
2416 PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA)
| Hotel | |||||
| Serial Number | Fixtures | Public Room | Non Residential Staff | ||
| Male | Female | Male | Female | ||
| I. | Toilet suite comprising one Water Closets (WC), wash basin with shower or a bath tub | Individual guest rooms with attached toilets | - | ||
| Guest room with common facilities | |||||
| II. | Water Closets | 1 per 100 persons up to 400; over 400 add at 1 per 250 or part thereof | 1 per 100 persons up to 200; over 200 add at 1 per 100 or part thereof | 1 for up to 15 2 for 16 to 35 3 for 36 to 65 4 for 66 to 100 | 1 for up to 12 2 for 13 to 25 3 for 26 to 40 4 for 41 to 57 5 for 58 to 77 6 for 78 to 100 |
| III. | Ablution tab | 1 in each water closet 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals | |||
| IV. | Urinals | 1 per 50 person or part thereof | - | 1 for 1 to 20 2 for 21 to 45 3 for 46 to 65 4 for 66 to 100 | - |
| V. | Wash Basins | 1 per Water Closets (WC) | 1 per Water Closets (WC) | 1 for up to 15 2 for 16 to 35 3 for 36 to 65 4 for 66 to 100 | 1 for up to 12 2 for 13 to 25 3 for 26 to 40 4 for 41 to 57 |
PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 2417 (BHDR 19, 1943 SAKA)
| Serial Number | Fixtures | Patient Toilets Staff Toilets |
| Male Female Male Female | ||
| VI. | Bath (showers) | 1 per 10 person or part thereof |
| VII. | Cleaner's sink | 1 per 30 rooms, minimum 1 per floor |
| VIII. | Kitchen sink | 1 per kitchen |
Notes :-
(a) Some Water Closets (WC) may be Indian style, if desired.
(b) Male population may be assumed as two-third and female population as one-third.
(c) Provision for additional and special fittings where required shall be made.