24 Compliance of zoning plan or standard design or architectural control sheets and master plan/ zonal plan.- In addition to these rules, the erection or re-erection of any building(s) and uses thereof as well as activities permissible therein shall comply with the provisions of the Zoning Plan or Standard Design or Architectural Control Sheets; schedule of clauses appended thereto and use of the site shall conform to the Master Plan or Zonal Plan of the area.
25 Compliance to Special Area development and control as per Master Plan or Zonal Plan.- For the planned and regulated development of all ‘Special Areas’ with specific emphasis on harmonious development with Public spaces, the planning and development shall be undertaken by specially formulated Form Based Codes (FBCs) for each such ‘Special Area’, namely:-
(1) Planning authority to delineate “Form Based Zoning Districts” within the Master or Zonal Plan for special consideration of planning with integrated Public spaces;
(2) Form Based Zoning Districts (FBCs) to be formulated for each such Form Based Zoning Districts (FBZDs) with Single or Multiple Regulating Plans as necessary to cover the entire delineated special area;
(3) Space Use matrix along with Form Based Codes (FBC) development standards, for each Form Based Zoning District (FBZD) as formulated in the Form Based Codes (FBC) are to be used for site layouts and building designs for all types of buildings; and
(4) Form Based Codes (FBC) standards of flexible and adaptive designs shall be superseding, overriding all stipulations from rule 3 to rule 8 of these rules for all types of buildings in the respective Form Based Zoning Districts (FBZDs).
26General Planning/ Development Norms.-
(1) Setbacks and Height of other buildings.– For buildings other than residential plotted or independent floors or row type buildings or crèche or pre nursery or nursery school or farm house, the set back around the building(s) or outer open spaces shall be as given in the Table below: -
Minimum Setback or Open Space Around Buildings
Serial Number
Height of building (m)
Setback all around building (m)
I.
10
3
II.
14.99
5
III.
18
6
IV.
21
7
V.
24
8
VI.
27
9
VII.
30
10
VIII.
35
11
IX.
40
12
X.
45
13
XI.
50
14
XII.
55
16
XIII.
70
17
XIV.
120
18
XV.
Above 120
20
Notes:
(a) In case of industrial buildings (except I.T. buildings), the open spaces around the building shall not be less than 4.5m for height upto 15 m, with an increase of the open spaces of 0.25 m for every increase of 1 m or fraction thereof in height above 15m. However, for industrial plots (including I.T Buildings) upto 2025 sq.m area where width of the plot is less than 30.50 m (100'-0"), the front and rear set back shall be ¼ of the height or 2m whichever is more are mandatory. The side setbacks may be relaxed subject to the condition that the owner has to submit a fire safety certificate from the competent authority in this regard.
(b) Where rooms do not derive light and ventilation from the exterior open space, the width of such exterior open space as given above may be reduced by 1 m subject to a minimum of 3m and a maximum of 8m.
(c) In case of Residential Group Housing, if the length or depth of the building exceeds 40 m, add to the above Table ten percent of length or depth of building minus 4.0 m subject to maximum requirement of 20 m.
(d) For high rise buildings and special buildings as specified in rule 30(11) (see Part4 Fire and Life Safety' of the National Building Code of India, 2016 as amended from time to time), the approach to the building and open spaces on all sides shall not be less than 6 m.
(e) For buildings other than residential plotted or independent floors, industrial plotted or general industrial buildings, or hazardous building, minimum setback from the boundary shall be 6 m or as shown in zoning plan whichever is more. However, for the plots upto 2025 sq.m area where width of the plot is less than 30.50m (100'-0") and the maximum height of building is below 15m excluding the architectural and symbolism element of religious building like dome, minarets, sikharas, crucifix etc. from building height then one side setback may be relaxed subject to the condition that the owner has to submit a fire safety certificate from the competent authority in this regard.
However, if the corner plot upto 2025sq.m in size, the side setback adjoining to the side road may be relaxed and shall not be less than 3 m from the boundary subject to the following conditions, namely:
(i) Minimum road width of side road shall not less than 9m.
(ii) Minimum setback of the building shall be governed as per table above from the centre of the adjoining side road for this side.
(iii) This relaxation shall be applicable only for one time for one side and not applicable for front and rear side.
(iv) The height of the boundary wall including railing for this side shall not be more than 2m.
(v) No objection certificate from Fire Department is required for this relaxation.
(f) In Tower like/ recessed building(s) deficiency of setbacks shall be achieved through additional setbacks at upper levels.
(2) Setback of projected portion of roof level.- The projected portion of parapet, flues, ducts, water storage tanks, mumties, minarets, domes, water cooling tanks, lift rooms exceeding 2.75 meters in height shall be receded from the facade by a minimum distance equal to their height above roof level, failing which these shall be counted in calculating the height of the building as well as covered area.