3Section (A) RESIDENTIAL.- For planning and architectural control of residential 180 (2) buildings, the norms shall be specified in the following tables, namely;-
(1) Residential Plots or Villas; (Except Affordable and Economical Weaker Section Housing)
Serial Number
Parameter
Permissible Limits as per Plot Size (sq.m)
Category of Plots
Minimum 60 to 100
Above 100 to 150
Above 150 to 250
Above 250 to 350
Above 350 to 450
Above 450
1.
Minimum Set back required:-
As per Uniform Zoning Plan Drawing no. 01/2020 CTP(Pb) Dated 28.07.2020 issued vide letter no. 2910-42 CTP (Pb)/SP-28 Dated 17.08.2020
2.
Ground Coverage (Max. Permissible)
0.70 x Plot Area
0.70 x Plot Area
0.65 x (Plot Area-150) + 105
0.60 x (Plot Area-250) + 170
0.50 x (Plot Area-350) + 230
0.40 x (Plot Area-450) + 280
3.
Maximum Permissible Floor Area Ratio
2.1 x Plot Area
2.1 x Plot Area
2.1 x Plot Area
2.1 x Plot Area
2.1 x Plot Area
2.1 x Plot Area
4.
Plinth Level
900mm (from the crown of adjoining road in front)
5.
Height (maximum Permissible)
11m from the plinth level of the building.
6.
Maximum numbers of Storeys allowed
Ground + 2 Floors (excluding basement)
7.
Minimum requirements of different component of a building
(a) one or more openings, such as windows and ventilators, opening directly to the external air or into an open Verandah.(b) such openings, excluding doors inclusive of frames, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 precent.
9.
Ventilation Shaft
the size of ventilation shaft shall not be less than the values given below:
Height of building
Size
Min. one dimension
10m
1.2 sq.m
0.9 m
Above 10m
2.8 sq.m
1.2 m
10.
Interior Courtyard
Minimum area:
9 sq.m
Minimum width:
2.4m or 1/5 of the average height of the building, whichever is more.
Allowed as per the provisions of the National Building Code of India, 2016.
15.
Mumty
Allowed upto 2.75 m, otherwise counted towards the height of the building as well as Floor Area Ratio.
16.
Services in terrace
Solar Photo Voltaic installation, Water tank, Rain water pipes with drainage, mumty, machine room and screening parapet to hide services or as per the provisions of the National Building Code of India, 2016.
17.
Gate
Allowed as per zoning plan
18.
Boundary wall
Maximum height allowed: -Front: upto 0.9m solid wall with 0.9m high perforated Grill/Jali.Side & Rear: upto 1.83m.Minimum Turning Radius for corner plot: -5'-0".
19.
Basement
Single story basement is allowed upto zoned area subject to the condition that the owner shall leave minimum 2.44 m (8'-0") setback from the boundary wall of the plot:
Provided that the above condition of 2.44 m (8'-0") setback from the adjoining plot shall not be mandatory if adjoining plot does not have a building upto 2.44m from the plot line.The area of the basement should not be more than the ground coverage.Minimum clear height for basement shall be as below:Non-Habitable use: 2.40 mHabitable Use: 2.75 m
20.
Ramp
Not required
21.
Minimum Parking Space required
2 numbers Two-wheeler
1 Car and 2 numbers Two-wheeler
1 Car and 2 numbers Two-wheeler
2 Car and 2 numbers Two-wheeler
2 Car and 2 numbers Two-wheeler
upto plot size500 sq.m: 2 Car and 2 numbers Two-wheeleravove plot size500 sq.m: 3 Car and 2 numbers Two-wheeler
22.
Allowable Projection
0.91m or 1/3 corresponding depth of front or rear setback whichever is less
1.83 m wide
23.
Allowable Balcony
1.22 m or 1/3 corresponding depth of front or rear setback whichever is less
Residential buildings are also recommended to meet its hot water demand from solar water heaters, as far as possible
26.
Solar Photo Voltaic
Plot size
Minimum requirement
400yd² (334m²) to 499yd² (417m²) :
1 KWp SPV
500yd² (418m²) to 999yd² (835m²) :
2 KWp SPV
1000yd² (836m²) to 1999yd² (1671m²) -:
3 KWp SPV
2000yd² (1672m²) and above :
5 KWp SPV
27.
Flushing System
Provision of dual button type flushing cistern in each water closet.
28.
Parapet or Railing
Minimum Height: 1.0 m Maximum Height: 1.4 m from the finished floor level
29.
Minimum passage or corridor
1050 mm.
30.
Amalgamation or Fragmentation
Amalgamation allowed. Fragmentation not allowed.
a) Basement, if constructed, may be used for parking, household storage, habitable and consultancy service purposes. Basement shall be counted towards Floor Area Ratio, if used for habitable purposes.
b) Front boundary wall shall be optional for providing easy access for parking in front setback within plot area for which approval from the concerned Competent Authority shall be obtained.
c) No opening is allowed on party wall of properties.
d) The maximum permissible ground coverage and Floor Area Ratio is subjected to the fulfilment of the setback, height and parking norms, and
e) In small size plot upto 105 sq.m (125 sq.yd) area, front setback may be relaxed upto 1.5m irrespective of building height.
(a) one or more openings, such as windows and ventilators, opening directly to the external air or into an open Verandah.(b) such openings, excluding doors inclusive of frames, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 precent.
9.
Ventilation Shaft
the size of ventilation shaft shall not be less than the values given below:
Height of building
Size
Min. one dimension
10m
1.2 sq.m
0.9 m
Above 10m
2.8 sq.m
1.2 m
10.
Interior Courtyard
Minimum area: 9 sq.mMinimum width: 2.4m or 1/5 of the average height of the building, whichever is more.
Allowed as per the provisions of the National Building Code of India, 2016.
14.
Mumty
Allowed upto 2.75 m, otherwise counted towards the height of the building as well as Floor Area Ratio.
15.
Services in terrace
Allowed as specified in the National Building Code of India, 2016
16.
Gate
Maximum height shall not more than 1.83 m
17.
Boundary wall
Maximum height allowed: -Front: upto 0.9m with 0.9m high perforated Grill/Jali.Side & Rear: upto 1.83m.Minimum Turning Radius for corner plot: -5'-0".
18.
Basement
Single story basement is allowed if plot area is 800 sq.m or more, upto zoned area subject to the condition that the owner shall leave minimum 2.44 m (8'-0") setback from the boundary wall of the plot:Provided that the above condition of 2.44 m (8'-0") setback from the adjoining plot shall not be mandatory if adjoining plot does not have a building upto 2.44m from the plot line.The area of the basement should not be more than the ground coverage.Minimum clear height for basement shall be as below:Non-Habitable use: 2.40 mHabitable Use: 2.75 m
19.
Ramp
Not required
20.
Stilt, if provided (Non-habitable height)
Clear Height shall be 7'-6".Parking provided under stilts shall not be counted towards Floor Area Ratio but shall be counted toward height of building.
Provision of dual button type flushing cistern in each water closet.
28.
Parapet or Railing
Minimum Height: 1.0 mMaximum Height: 1.4 m from the finished floor level
29.
Minimum passage or corridor
1050 mm for single loaded and 1500 mm for double loaded.This width shall increase with increase in the occupant load of the building and shall provide as per the National Building Code of India, 2016.
30.
Amalgamation or Fragmentation
Amalgamation allowedFragmentation not allowed
NOTES:-
a) Basement, if constructed, may be used for parking, household storage, habitable and consultancy service purposes. Basement shall be counted towards Floor Area Ratio if used for habitable purposes.
b) Front boundary wall shall be optional for providing easy access for parking in front setback within plot area for which approval from the concerned Competent Authority shall be obtained.
c) No opening is allowed on party wall of properties.
d) The maximum permissible ground coverage and Floor Area Ratio is subjected to the fulfillment of the setback, height and parking norms.
e) *Maximum height is excluding mumty, parapet, and architectural features.
f) The stilts shall be compulsory and shall be counted towards height of the building.
g) In case of Independent floors, plots shall be in a block of row housing and earmarked for independent floors in the Layout Plan or Zoning Plan.
h) No individual plot in any block which is not earmarked in the Layout Plan or Zoning Plan for independent floors shall be allowed to be constructed as an independent floor unless the building is detached having minimum plot area 800 square meters.
i) The parking required in case of independent floors shall compulsorily be under stilts. However, in case of an independent plot having minimum area of 800 square meters used for independent floors, the parking under stilts shall be optional, provided that the promoter provides surface/ basement parking as per norms within the plot.
(3) Group Housing
Serial Number
Parameter
Permissible Limits
1.
Minimum Set back around building required
6m minimum from site boundary and as per sub rule (1) of rule 26 of these building rules.
2.
Maximum Permissible Ground Coverage
30 percent of Site area
3.
Maximum Permissible Floor Area Ratio
Minimum approach road 18 m
1:2.0
Minimum approach road 24 m
1:2.5
Minimum approach road 30 m
1:3.0
Minimum approach road 45 m & above
Unlimited*
4.
Maximum Permissible Height
No Restriction subject to the fulfilment of norms such as setbacks around building, ground coverage, Floor Area Ratio, structural safety and fire safety norms.
However, clearance from Airport Authority of India or Indian Air Force is required in case the height of the building is 15m or more or site falls in the red colour of home grid of Colour Coded Zoning Map issued by Airports Authority of India or Indian Air Force.
5.
Plinth Level
450mm or as specified by competent authority (from the crown of adjoining road in front).Provided that for a detached building, the plinth level may be more than 450mm:Provided further that the level of front courtyard of any building shall not exceed 450 mm and the ramp from the front road to the courtyard shall be within the plot boundary.
6.
Minimum requirements of different component of a building
Component of Building
Min. area (SQ.M)
Min.Width (M)
Min.Clear Height (M)
Habitable room
9.5
2.4
2.75
Kitchen
• where separate dining area is provided
5
1.8
• where separate store is provided
4.5
1.8
2.75
• where dinning included
7.5
2.1
Bathroom
1.8
1.2
2.1
Water Closet (W.C.)
1.2
0.9
2.1
combined bath and w.c
2.8
1.2
2.1
Store
3
1.2
2.2
Single occupancy Servant Room
7.5
2.1
2.75
Serial Number
Parameter
Permissible Limits
7.
Light and Ventilation
(a) one or more openings, such as windows and ventilators, opening directly to the external air or into an open Verandah.(b) such openings, excluding doors inclusive of frames, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 percent.
8.
Ventilation Shaft
the size of ventilation shaft shall not be less than the values given below:
Height of building
Size (sq.m)
Min. one dimension
10m
1.2
0.9 m
12m
2.8
1.2 m
18m
4.0
1.5 m
24m
5.4
1.8 m
30m
8.0
2.4 m
Above 30m
9.0
3.0 m
Notes:(a) For buildings of height above 30 m, a mechanical ventilation system shall be installed besides the provision of minimum ventilation shaft.(b) For fully air conditioned the ventilation shaft need not be insisted upon, provided the air conditioning system works in an uninterrupted manner, also, provided there is an alternative source of power supply.(c) Mechanical ventilation in building shall be as per the provision of the National Building Code of India, 2016, as amended from time to time.
9.
Interior Courtyard for Light and Ventilation
Minimum area: 9 sq.mMinimum width: 2.4m or 1/5 of the average height of the building, whichever is more.
10.
Staircase requirement:
Minimum Width: Minimum Tread: Maximum Riser: Minimum Clear Head Height:
Lift is mandatory in buildings 15m or more in height and basement provided more than one level as per the provision of the National Building Code of India, 2016.Ramp requirement for pedestrians, differently-abled, elderly and children upto Plinth Level :-Min. Width - 1800mmMin. Slope - 1:12
12.
Mumty
Allowed upto 2.75 m, otherwise counted towards the height of the building as well as Floor Area Ratio.
13.
Services in terrace
Solar Photo Voltaic installation, Rain water pipes with drainage, Water Tank, cooling towers for air conditioning plants, mumty, machine room and screening parapet to hide services or as per the provisions of the National Building Code of India, 2016.
14.
Gate and post check
Watch and ward cabins upto 100 sq.ft along each entry gate exempted from Ground Coverage and Floor Area Ratio (FAR).
15.
Boundary wall
Maximum height allowed:-Facing road or open area: upto 0.9m solid wall with 0.9m high perforated Grill/Jali.Facing other property: upto 1.83m solid wallMinimum Turning Radius for corner plot:-5'-0" or 1/8th of the adjoining road width, whichever is more and maximum upto 20'-0".
16.
Basement
The multi-level basement in plots of an area above 2025 sq.m shall be allowed below the ground and beyond the building line at ground level subject to a clear minimum front margin of 4.5 m and side and rear margins of 3 m, subject to the provision of mechanical ventilation and all safety provisions and drainage.Basement shall not be allowed in the case of No construction Zone/Area or Master Plan Green area or any other restricted area/zone under the provision of any other Act/policy of the State or Central Government.
Serial Number
Parameter
Permissible Limits
Minimum clear height for basement shall be as below:Non-Habitable use: 2.40 mHabitable Use: 2.75 m
17.
Stilt, if provided (Non-habitable height)
Clear Height shall be 7'-6".Parking provided under stilts shall not be counted towards Floor Area Ratio and height.
18.
Vehicular Ramp
Ramps are mandatory.Minimum width: 7.2m for two way trafficSlope: (i) Cars 4m for one way traffic(ii) Heavy vehicles not less than 1:8 and at curve 1:12not less than 1:15
19.
Minimum Parking required as per size of Dwelling Unit size
Provision of dual button type flushing cistern in each water closet.
26.
Parapet or Railing
Minimum Height: 1.0 mMaximum Height: 1.4 m from the finished floor level
27.
Minimum passage or corridor
1350 mm for single loaded and 1800 mm for double loaded.This width shall increase with increase in the occupant load of the building and shall provide as per the National Building Code Of India, 2016.
28.
Economically Weaker Section (EWS)
As per the government policy dated 24.05.2016 or as amended from time to time.
29.
Green Area requirement
Minimum 25 percent of site area in which 15 percent of site area shall be in the form of organized park or playground with minimum width of 15m.
30.
Convenient Shopping
Maximum upto 1 percent of the total Floor Area Ratio area shall be allowable for convenient shopping such as grocery shop, vegetable shop, laundry and dry cleaning, medical store, confectionery, bakery, hair cutting saloon, stationery shop, milk booth excluding Club Building.
31.
Amalgamation or Fragmentation
Amalgamation not allowedFragmentation not allowed
Notes:-a) The Floor Area Ratio above 1:2 in case of Group Housing will be chargeable on pro-rata basis. However, the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter.b) *Unlimited Floor Area Ratio shall be subject to fulfillment of building controls such as ground coverage, setbacks around the building, parking norms, light and ventilation, height, fire and structural safety.c) Access to commercial building in group housing may be allowed from external road subject to the fulfillment of parking, setback and road width etc.d) The Net Residential Density shall be permissible as per the provisions of the respective Master Plans, government notifications as amended from time to time whichever is applicable.e) For calculation of infrastructure required for the project, the population for group housing shall be @ 4.5 persons per Dwelling Unit.
(4) Studio Apartment
Serial Number
Parameter
Permissible Limits
1.
Minimum Site Area
2000 sq.m
2.
Maximum size of Unit
50 sq.m
3.
Minimum Set back around building required
6m minimum from site boundary and as per sub rule (1) of rule 26 of these building rules.
4.
Maximum Permissible Ground Coverage
30 percent of Site area
5.
Maximum Permissible Floor Area Ratio
Minimum approach road 18 m
1:2.0
Minimum approach road 24 m
1:2.5
Minimum approach road 30 m
1:3.0
Minimum approach road 45 m & above
Unlimited*
6.
Maximum Permissible Height
No Restriction subject to the fulfilment of norms such as setbacks around building, ground coverage, Floor Area Ratio, structural safety and fire safety norms.However, clearance from Airport Authority of India or Indian Air Force is required in case the height of the building is 15m or more or site falls in the red colour of home grid of Colour Coded Zoning Map issued by Airports Authority of India or Indian Air Force.
7.
Plinth Level
450mm or as specified by competent authority (from the crown of adjoining road in front).Provided that for a detached building, the plinth level may be more than 450mm:Provided further that the level of front courtyard of any building shall not exceed 450 mm and the ramp from the front road to the courtyard shall be within the plot boundary.
8.
Minimum requirements of different component of a building
(a) one or more openings, such as windows and ventilators, opening directly to the external air or into an open Verandah(b) such openings, excluding doors, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 percent.
10.
Ventilation Shaft
the size of ventilation shaft shall not be less than the values given below:-
Height of building
Size (sq.m)
Min. one dimension
10m
1.2
0.9 m
12m
2.8
1.2 m
18m
4.0
1.5 m
24m
5.4
1.8 m
30m
8.0
2.4 m
Above 30m
9.0
3.0 m
Notes:
(a) For buildings of height above 30 m, a mechanical ventilation system shall be installed besides the provision of minimum ventilation shaft.
(b) For fully air conditioned the ventilation shaft need not be insisted upon, provided the air conditioning system works in an uninterrupted manner, also, provided there is an alternative source of power supply.
Serial Number
Parameter
Permissible Limits
(c) Mechanical ventilation in building shall be as per the provision of the National Building Code of India, 2016, as amended from time to time.
11.
Interior Courtyard
Minimum area: 9 sq.mMinimum width: 2.4m or 1/5 of the average height of the building, whichever is more.
12.
Staircase requirement:
Minimum Width: 1350 mmMinimum Tread: 300 mmMaximum Riser: 150 mmMinimum Clear Head Height: 2200 mm
13.
Lift and Ramp requirement
Lift is mandatory in buildings 15m or more in height and basement provided more than one level as per the provision of the National Building Code of India, 2016. Ramp requirement for pedestrians, differently-abled, elderly and children upto Plinth Level :-Min. Width - 1800mmMin. Slope - 1:12
14.
Mumty
Allowed upto 2.75 m, otherwise counted towards the height of the building as well as Floor Area Ratio.
15.
Services in terrace
Solar Photo Voltaic installation, Rain water pipes with drainage, Water Tank, cooling towers for air conditioning plants, mumty, machine room and screening parapet to hide services or as per the provisions of the National Building Code Of India, 2016.
16.
Gate and post check
Watch and ward cabins upto 100 sq.ft along each entry gate exempted from Ground Coverage and Floor Area Ratio (FAR).
17.
Boundary wall
Maximum height allowed: -Facing road or open area: upto 0.9m solid wall with 0.9m high perforated Grill/Jali.Facing other property: upto 1.83m solid wall.Minimum Turning Radius for corner plot: -5'-0" or 1/8th of the adjoining road width, whichever is more and maximum upto 20'-0".
Plot size upto 2025 sq.m: single story basement is allowed upto zoned area or upto the boundary of the plot except front and rear side, as the case may be, subject to the condition that the owner shall leave minimum 2.44 m (8'-0") setback from the respective side of the boundary wall of the plot, if adjoining plot has a building upto 2.44m from the plot line.Plot size above 2025 sq.m: The multi-level basement shall be allowed below the ground and beyond the building line at ground level subject to a clear minimum front margin of 4.5 m and side and rear margins of 3 m, subject to the provision of mechanical ventilation and all safety provisions and drainage.Basement shall not be allowed in the case of No construction Zone/ Area or Master Plan Green area or any other restricted area/zone under the provision of any other Act/policy of the State or Central Government.Minimum clear height for basement shall be as below:Non-Habitable use: 2.40 mHabitable Use: 2.75 m
19.
Stilt, if provided (Non-habitable height)
Clear Height shall be 7'-6".Parking provided under stilts shall not be counted towards Floor Area Ratio and height.
20.
Vehicular Ramp
Ramps are mandatory.Minimum width: 7.2m for two way trafficSlope: (i) Cars 4m for one way traffic(ii) Heavy vehicles not less than 1:8 and at curve 1:12 not less than 1:15
21.
Minimum Parking Space required
2 Equivalent Car Space per 100 sq.m of total Floor Area Ratio area
22.
Projection (Free from Ground Coverage and Floor Area Ratio)
1.83 m wide
Serial Number
Parameter
Permissible Limits
23.
Balcony(Free from Ground Coverage and Floor Area Ratio)
1.83 m wide
24.
Rain Water Harvesting System
Mandatory requirement
25.
Solar Water Heating System
Residential buildings are also recommended to meet its hot water demand from solar water heaters, as far as possible
26.
Solar Photo Voltaic required as per plot size
Plot size
Requirement
(a) 0.5 acre to 1 acre(b) Above 1 acre to 2 acres(c) Above 2 acre to 5 acres(d) Above 5 acre
Minimum 10 Kilo Watt (KWp)Minimum 20 Kilo Watt (KWp)Minimum 30 Kilo Watt (KWp)Minimum 40 Kilo Watt (KWp)
27.
Flushing System
Provision of dual button type flushing cistern in each water closet.
28.
Parapet or Railing
Minimum Height: 1.0 mMaximum Height: 1.4 m from the finished floor level
29.
Minimum passage or corridor
1350 mm for single loaded and 1800 mm for double loaded. This width shall increase with increase in the occupant load of the building and shall provide as per National Building Code of India, 2016.
30.
Economically Weaker Section (EWS)
As per the government policy dated 24.05.2016 or as amended from time to time.
31.
Green Area requirement
Minimum 25 percent of site area in which 15 percent of site area shall be in the form of organized park or playground with minimum width of 15m.
32.
Amalgamation or Fragmentation
Amalgamation allowedFragmentation not allowed
Notes:-
a) The population density of Studio Apartments shall be counted as two persons per unit.
b) The Floor Area Ratio above 1:2 in case of Studio Apartments will be chargeable on pro-rata basis. However, the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter.
(BHDR 19, 1943 SAKA)
c) *Unlimited Floor Area Ratio shall be subject to fulfillment of building controls such as ground coverage, setbacks around the building, parking norms, light and ventilation, height, fire and structural safety.
d) The Net Residential Density shall be permissible as per the provisions of the respective Master Plans, government notifications as amended from time to time whichever is applicable.
j) Clear height of Stilt from the finished level of the ground floor to the under surface of the beam, joint girders or any other horizontal structure member shall be 7’-6”.
k) In case of independent floor, common staircase or common elevator is permissible maximum for two plots subject to the condition that the minimum clear width of staircases shall be 1350 mm.
l) Parking in independent floors under stilts shall be permissible beyond stilts within the plot area, if the parking under stilts is not sufficient as per norms, and
m) For calculation of infrastructure required for the project, the population of independent floors having S+4 or G+3 it shall be @ 20 persons per plot, where basement is used for habitable purpose then the density of five person per basement shall be added to the permissible density of the plot.