3Section (A) RESIDENTIAL.- For planning and architectural control of residential 180 (2) buildings, the norms shall be specified in the following tables, namely;-
(1) Residential Plots or Villas; (Except Affordable and Economical Weaker Section Housing)
| Serial Number | Parameter | Permissible Limits as per Plot Size (sq.m) | |||||
| Category of Plots | Minimum 60 to 100 | Above 100 to 150 | Above 150 to 250 | Above 250 to 350 | Above 350 to 450 | Above 450 | |
| 1. | Minimum Set back required:- | As per Uniform Zoning Plan Drawing no. 01/2020 CTP(Pb) Dated 28.07.2020 issued vide letter no. 2910-42 CTP (Pb)/SP-28 Dated 17.08.2020 | |||||
| 2. | Ground Coverage (Max. Permissible) | 0.70 x Plot Area | 0.70 x Plot Area | 0.65 x (Plot Area-150) + 105 | 0.60 x (Plot Area-250) + 170 | 0.50 x (Plot Area-350) + 230 | 0.40 x (Plot Area-450) + 280 |
| 3. | Maximum Permissible Floor Area Ratio | 2.1 x Plot Area | 2.1 x Plot Area | 2.1 x Plot Area | 2.1 x Plot Area | 2.1 x Plot Area | 2.1 x Plot Area |
| 4. | Plinth Level | 900mm (from the crown of adjoining road in front) | |||||
| 5. | Height (maximum Permissible) | 11m from the plinth level of the building. | |||||
| 6. | Maximum numbers of Storeys allowed | Ground + 2 Floors (excluding basement) | |||||
| 7. | Minimum requirements of different component of a building | Component of Building | Min. area (SQ.M) | Min. Width (M) | Min. Clear Height(M) | ||
| Habitable room | 9.5 | 2.4 | 2.75 | ||||
| Kitchen | |||||||
| • where separate dining | 5 | 1.8 | |||||
2298 PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA)
| Serial Number | Parameter | Permissible Limits as per Plot Size (sq.m) | |||||
| Category of Plots | Minimum 60 to 100 | Above 100 to 150 | Above 150 to 250 | Above 250 to 350 | Above 350 to 450 | Above 450 | |
| area is provided | |||||||
| • where separate store is provided | 4.5 | 1.8 | 2.75 | ||||
| • where dinning included | 7.5 | 2.1 | |||||
| Bathroom | 1.8 | 1.2 | 2.1 | ||||
| Water Closet (W.C.) | 1.2 | 0.9 | 2.1 | ||||
| Combined Bath and W.C. | 2.8 | 1.2 | 2.1 | ||||
| Store | 3.0 | 1.2 | 2.2 | ||||
| Garage | 18.0 | 3.0 | 2.4 | ||||
| Single Occupancy Servant Room | 7.5 | 2.1 | 2.75 | ||||
| 8. | Light and Ventilation | (a) one or more openings, such as windows and ventilators, opening directly to the external air or into an open Verandah.(b) such openings, excluding doors inclusive of frames, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 precent. | |||||
| 9. | Ventilation Shaft | the size of ventilation shaft shall not be less than the values given below: | |||||
| Height of building | Size | Min. one dimension | |||||
| 10m | 1.2 sq.m | 0.9 m | |||||
| Above 10m | 2.8 sq.m | 1.2 m | |||||
| 10. | Interior Courtyard | Minimum area: | 9 sq.m | ||||
| Minimum width: | 2.4m or 1/5 of the average height of the building, whichever is more. | ||||||
| 11. | Verandah for Light & Ventilation | Minimum width 2.4 m | |||||
PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 2299 (BHDR 19, 1943 SAKA)
| Serial Number | Parameter | Permissible Limits as per Plot Size (sq.m) | |||||
| Category of Plots | Minimum 60 to 100 | Above 100 to 150 | Above 150 to 250 | Above 250 to 350 | Above 350 to 450 | Above 450 | |
| 12. | Staircase requirement: | ||||||
| Minimum Width | 900mm | 1000mm | |||||
| Minimum Tread | 250mm | 250mm | |||||
| Maximum Riser | 190mm | 190mm | |||||
| Minimum Clear Head Height | 2200mm | 2200mm | |||||
| 13. | Construction in Back courtyard | Not allowed | |||||
| 14. | Lift | Allowed as per the provisions of the National Building Code of India, 2016. | |||||
| 15. | Mumty | Allowed upto 2.75 m, otherwise counted towards the height of the building as well as Floor Area Ratio. | |||||
| 16. | Services in terrace | Solar Photo Voltaic installation, Water tank, Rain water pipes with drainage, mumty, machine room and screening parapet to hide services or as per the provisions of the National Building Code of India, 2016. | |||||
| 17. | Gate | Allowed as per zoning plan | |||||
| 18. | Boundary wall | Maximum height allowed: -Front: upto 0.9m solid wall with 0.9m high perforated Grill/Jali.Side & Rear: upto 1.83m.Minimum Turning Radius for corner plot: -5'-0". | |||||
| 19. | Basement | Single story basement is allowed upto zoned area subject to the condition that the owner shall leave minimum 2.44 m (8'-0") setback from the boundary wall of the plot: | |||||
2300 PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA)
| Serial Number | Parameter | Permissible Limits as per Plot Size (sq.m) | |||||
| Category of Plots | Minimum 60 to 100 | Above 100 to 150 | Above 150 to 250 | Above 250 to 350 | Above 350 to 450 | Above 450 | |
| Provided that the above condition of 2.44 m (8'-0") setback from the adjoining plot shall not be mandatory if adjoining plot does not have a building upto 2.44m from the plot line.The area of the basement should not be more than the ground coverage.Minimum clear height for basement shall be as below:Non-Habitable use: 2.40 mHabitable Use: 2.75 m | |||||||
| 20. | Ramp | Not required | |||||
| 21. | Minimum Parking Space required | 2 numbers Two-wheeler | 1 Car and 2 numbers Two-wheeler | 1 Car and 2 numbers Two-wheeler | 2 Car and 2 numbers Two-wheeler | 2 Car and 2 numbers Two-wheeler | upto plot size500 sq.m: 2 Car and 2 numbers Two-wheeleravove plot size500 sq.m: 3 Car and 2 numbers Two-wheeler |
| 22. | Allowable Projection | 0.91m or 1/3 corresponding depth of front or rear setback whichever is less | 1.83 m wide | ||||
| 23. | Allowable Balcony | 1.22 m or 1/3 corresponding depth of front or rear setback whichever is less | 1.83 m wide | ||||
| 24. | Rain Water Harvesting System | Not required | Required | ||||
PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 2301 (BHDR 19, 1943 SAKA)
| Serial Number | Parameter | Permissible Limits as per Plot Size (sq.m) | |||||
| Category of Plots | Minimum 60 to 100 | Above 100 to 150 | Above 150 to 250 | Above 250 to 350 | Above 350 to 450 | Above 450 | |
| 25. | Solar Water Heating System | Residential buildings are also recommended to meet its hot water demand from solar water heaters, as far as possible | |||||
| 26. | Solar Photo Voltaic | Plot size | Minimum requirement | ||||
| 400yd² (334m²) to 499yd² (417m²) : | 1 KWp SPV | ||||||
| 500yd² (418m²) to 999yd² (835m²) : | 2 KWp SPV | ||||||
| 1000yd² (836m²) to 1999yd² (1671m²) -: | 3 KWp SPV | ||||||
| 2000yd² (1672m²) and above : | 5 KWp SPV | ||||||
| 27. | Flushing System | Provision of dual button type flushing cistern in each water closet. | |||||
| 28. | Parapet or Railing | Minimum Height: 1.0 m Maximum Height: 1.4 m from the finished floor level | |||||
| 29. | Minimum passage or corridor | 1050 mm. | |||||
| 30. | Amalgamation or Fragmentation | Amalgamation allowed. Fragmentation not allowed. | |||||
a) Basement, if constructed, may be used for parking, household storage, habitable and consultancy service purposes. Basement shall be counted towards Floor Area Ratio, if used for habitable purposes.
b) Front boundary wall shall be optional for providing easy access for parking in front setback within plot area for which approval from the concerned Competent Authority shall be obtained.
c) No opening is allowed on party wall of properties.
d) The maximum permissible ground coverage and Floor Area Ratio is subjected to the fulfilment of the setback, height and parking norms, and
e) In small size plot upto 105 sq.m (125 sq.yd) area, front setback may be relaxed upto 1.5m irrespective of building height.