| Serial Number | Fixtures | Offices/Visitors | Workers | ||
| Male | Female | Male | Female | ||
| I. | Water Closets (workers and staff) | 1 for up to 15 | 1 for up to 12 | 1 for up to 15 | 1 for up to 12 |
| 2 for 16 to 35 | 2 for 13 to 25 | 2 for 16 to 35 | 2 for 13 to 25 | ||
| 3 for 36 to 65 | 3 for 26 to 40 | 3 for 36 to 65 | 3 for 26 to 40 | ||
| 4 for 66 to 100 | 4 for 41 to 57 | 4 for 66 to 100 | 4 for 41 to 57 | ||
| From 101 to 200, add @3 percent; for over 200, add @ 2.5 percent | 5 for 58 to 77 6 for 78 to 100 From 101 to 200, add @ 5 percent; for over 200, add @ 4 percent | From 101 to 200, add @3 percent; for over 200, add @ 2.5 percent | 5 for 58 to 77 6 for 78 to 100 From 101 to 200, add @ 5 percent; for over 200, add @ 4 percent | ||
PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 2421 (BHDR 19, 1943 SAKA)
| Serial Number | Fixtures | Offices/Visitors | Workers | ||
| Male | Female | Male | Female | ||
| II. | Ablution tab | 1 in each water closet | |||
| III. | Urinals | 1 for 1 to 20 | - | 1 for 1 to 20 | - |
| 2 for 21 | 2 for 21 | ||||
| to 45 | to 45 | ||||
| 3 for 46 | 3 for 46 | ||||
| to 70 | to 70 | ||||
| 4 for 71 | 4 for 71 | ||||
| to 100 | to 100 | ||||
| From 101 to 200, add @ 3 percent; for over 200, add @ 2.5 percent | From 101 to 200, add @ 3 percent; for over 200, add @ 2.5 percent | ||||
| IV. | Wash Basins (wash basins in rows or troughs and taps spaced 750 mm c/c) | 1 per 25 or part thereof | |||
| V. | Drinking Water Fountain | 1 per 100 persons or part thereof with minimum one on each floor | |||
| VI. | Cleaner's sink | 1 on each floor | |||
| VII. | Showers/bathing rooms | As per trade requirements | |||
| VIII. | Emergency shower and eye wash fountain | - | - | 1 per every shop floor per 500 persons | |
Notes :-
(a) For factories requiring workers to be engaged in dirty and dangerous operations or requiring them to being extremely clean and sanitized conditions, additional and separate (if required so) toilet facilities and if required by applicable Industrial and safety laws and the Factories Act shall be provided in consultation with the user.
(b) Depending on the type of disability of a person and the hazard posed by the type of activities in the factory for a person with disabilities, if a person with disabilities is decided to be engaged for a particular activity, the requirements of accessibility shall be guided by the provisions given in 13 of Part 3 -'Development Control Rules and General Building Requirements of the National Building Code of India, 2016' as amended from time to time.
Schools and Educational Institutions
| Serial Number | Fixtures | Nursery School | Non-Residential | Residential | ||
| Boys | Girls | Boys | Girls | |||
| I. | Water Closets | 1 per 15 pupils or part thereof | 1 per 40 pupils or part thereof | 1 per 25 pupils or part thereof | 1 per 8 pupils or part thereof | 1 per 6 pupils or part thereof |
| II. | Ablution tab | 1 in each water closet1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals | ||||
| III. | Urinals | - | 1 per 20 pupils or part thereof | - | 1 per 25 pupils or part thereof | - |
| IV. | Wash Basins | 1 per 15 pupils or part thereof | 1 per 60 pupils or part thereof | 1 per 40 pupils or part thereof | 1 per 8 pupils or part thereof | 1 per 6 pupils or part thereof |
| V. | Drinking Water Fountain | 1 per 50 pupils or part thereof | 1 per 50 pupils or part thereof | 1 per 50 pupils or part thereof | ||
| VI. | Cleaner's sink | 1 per each floor | ||||
| VII. | Bath or Showers | 1 per 40 pupils or part thereof | - | 1 per 8 pupils or part thereof | 1 per 6 pupils or part thereof | |
Notes :-
(a) Some Water Closets (WC) may be Indian style, if desired.
(b) For teaching staff, the schedule of fixtures to be provided shall be the same as in case of office building.
| Hostels | |||||||
| Serial Number | Fixtures | Resident | Non-Resident | Visitor/ Common Room | |||
| Males | Females | Males | Females | Males | Females | ||
| I. | Water Closets | 1 per 8 or part thereof | 1 per 6 or part thereof | 1 for upto 152 for 16 to 353 for 36 to 654 for 66 to 100 | 1 for up to 122 for 13 to 253 for 26 to 404 for 41 to 575 for 58 to 776 for 78 to 100 | 1 per 100 up to 400; add at 1 per 250 | 1 per 100 up to 200; add at 1 per 100 |
| II. | Ablution tab 1 in each water closet | ||||||
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals | |||||||
| III. | Urinals | 1 per 25 - or part thereof | 1 for 1 to 202 for 21 to 453 for 46 to 704 for 71 to 100 | - | 1 per 50 or part thereof | - | |
| IV. | Wash Basins | 1 per 8 or part thereof | 1 per 6 or part thereof | 1 for up to 152 for 16 to 353 for 36 to 654 for 66 to 100 | 1 for up to 122 for 13 to 253 for 26 to 404 for 41 to 575 for 58 to 776 for 78 to 100 | 1 per Water Closets (WC) | 1 per Water Closets (WC) |
2424 PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA)
| Serial Number | Fixtures | Resident | Non-Resident | Visitor/ Common Room | |||
| Males | Females | Males | Females | Males | Females | ||
| V. | Bath or showers | 1 per 8 or part thereof | 1 per 6 or part thereof | - | - | - | - |
| VI. | Cleaner's sink | 1 per each floor | |||||
Notes :-
(a) Some Water Closets (WC) may be Indian style, if desired.
Fruit and Vegetable Markets
| Serial Number | Fixtures | Shop Owners | Common toilets in market building | public toilet for floating population | ||
| Males Females | Males | Females | Males | Females | ||
| I. | Water | 1 per 8 or part thereof | 1 for up to 15 | 1 for up to 12 | 1 per 50 | 1 per 50(min 2) (min 2) |
| Closets | 2 for 16 to 35 | 2 for 13 to 25 | ||||
| 3 for 36 to 65 | 3 for 26 to 40 | |||||
| 4 for 66 to 100 | 4 for 41 to 57 | |||||
| 5 for 58 to 77 | ||||||
| 6 for 78 to 100 | ||||||