6.1 Main Building :
The plinth of any part of a building or house shall be located with respect to average road level of site so that adequate drainage of the site is assured but not at a height less than 45 cm.—
(a) Habitable rooms shall have minimum plinth height of 0.45 m from the ground level.
The J&K Official Gazette, 24th Dec., 2021/3rd Agra., 1943. 109
(b) Parking garage may have no plinth.
(c) The ground floor of a building may be permitted on stills/pillars instead of a solid plinth with a height of 2.4 m. In case of slabs with beams height should not exceed 2.8 m. and further that this space shall at all the time be kept free from any enclosure except for genuine stair-case :
Provided further that an electric m room, room for telephone D.B. bath-room, watch room, stair case room, pump room, water closet, servant room, security cabin may be permitted subject to maximum built up area of 15 Sq. m. allowed with a minimum plinth height of 30 cm and this area shall not be considered towards computation of FAR.
6.2 Interior courtyards, covered parking spaces and garages :
These shall be raised at least 15 cm above the surrounding ground level and shall satisfactorily drained.
6.3 Habitable room size and width :
The minimum size and width shall be as given NBC-2016.
6.4 Non –residential Buildings :
The minimum area for office/room/shop or any other space to be used as workspace shall not be less than 6.0 sq. m. with a minimum width of 2.1 m.
6.5 Kitchen :
Any room to be used as kitchen shall have :
(a) Unless separately provided in pantry, means for washing of kitchen utensils, which shall lead directly or through a sink to a grated and trapped -connection to the waste pipe ;
(b) An impermeable floor ;
(c) At least a window not less than 1 Sq.m in area open directly to an interior or exterior open space, but not into a shaft ; and
(d) In residential building 15 m. or more in height refuse chutes.