a) A group or a group of persons or a co-operative society or firm intending to plot out an estate into more than 4 plots shall give notice in writing to the BPIA which will be accompanied by a layout plan of entire land showing the areas allotted for roads, open spaces, plot and public buildings, the specification of the roads, drains and other infrastructures.
b) Roads, drains, water mains and electric lines required for the colony shall be constructed by the developer at his own cost and no plot shall be eligible for any services and utilities by the govt. and/or Municipal Corporation unless the colony is developed properly and approved by the BPIA, and no building plan shall be considered by the municipality or prescribed authority in any plot of such a colony which has not received the prior approval of the BPIA. Developer in this case will mean the person, co-operative or the firm intending to plot out the land into more than 4 plots.
c) Land use of the layout plan approved by the BPIA shall not be changed unless with the prior consent of the BPIA.
d) Open spaces allocated for parks, playfields, utility sites/buildings in a colony shall be deemed to have been sold along with the plots as amenity of the colony by the developer to the plot holders of the colony. The development of such open spaces shall be the responsibility of the developer.
e) No permission shall be accorded for construction of a building in any notified area which shall cause nuisance by way of odour, smoke, noise or disturbance to inhabitants of the locality or be injurious to health of the residents of the buildings or to the inhabitants in the surrounding areas.
f) Norms for Colonies up to 1.0 Hectare:
| Land Distribution | |
|---|---|
| 1. Min. Approach Road | 9.0 m. |
| 2. Internal Roads | |
| Width of Means of Access | Length of Means of |
| (m) | Access (m) Max |
| 6.0 | 75 |
| 7.5 | 150 |
| 3. Area under Roads | Min. 12% |
| 4. Area under Green | Min. 10% |
| g) Norms for Colonies above 1 Hectare up to 4 Hectare: | |||
5.2.1.2 The regulations for Commercial and Public, Semi-Public building use in terms of Space/Plot area, Ground Coverage, FAR, Height and Setbacks/setbacks shall be as under :—
Table No. 5—4
| • Maximum Building Height and Minimum Setbacks | |||||||||
| Note:—WEIM = Whichever is more, NA = Not Allowed/Applicable, B. L= Building Line | |||||||||
| Commercial | |||||||||
| S.No. | Building Use | Plot Area (Sq. m) | Ground Coverage (%) | FAR | Max.Height.(m) | Min. Setbacks (m) | |||
| Front | Rear | Side | Side | ||||||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| 1. | Single Shop | Up to 100 | 70 | 210 | 12(G+2) | Shall be as per Table No. 5—2 | N | N | N |
| Note:—Shopping permissible on G+1 only. Basement shall not be allowed. | |||||||||
| 2. | Shopping Cluster | Above 100—300 | 60 | 180 | 14 | Shall be as per Table No. 5—2 | 3.0 | 3.0 | N |
| Note:—Shopping permissible on G+1 only. Basement shall not be allowed. | |||||||||
74 The J&K Official Gazette, 24th Dec., 2021/3rd Agra., 1943. [No. 39-4
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| Above300-750 | 50 | 180 | 14 | Shall be as per Table No. 5-2 | 3.0 | 3.0 | N | ||
| Note:-Single Basement within the building envelope shall be allowed as specified in the basement norms. Stilt floors within the building envelope shall be allowed for parking only. | |||||||||
| 3. | Commer-cial Complex | Above750-2000 | 45 | 180 | 20 | Shall be as per Table No. 5-2 | 3.0 or 1/3rd of Building Ht. (W.E.I.M) | 3.0 | 3.0 |
| Note:-Single Basement within the building envelope shall be allowed as specified in the basement norms. Stilt floors within the building envelope shall be allowed for parking only. | |||||||||
| Above2000-4000 | 40 | 180 | 25 | Shall be as per Table No. 5-2 | 6.0 or 1/3rd of Building Ht. (W.E.I.M) | 6.0 or 1/3rd of Building Ht. (W.E.I.M) | 6.0 or 1/3rd of Building Ht. (W.E.I.M) | ||
| Note:-Double basements if used for parking shall be allowed as specified in the basement norms. Stilt floors within the building envelope shall be allowed. | |||||||||
| Above4000 | 35 | 180 | Height to be regul-ated by Fire and Emer-gency Equip-ment available | Shall be as per Table No. 5-2 | 6.0 or 1/3rd of Building Ht. (W.E.I.M) | 6.0 or 1/3rd of Building Ht. (W.E.I.M) | 6.0 or 1/3rd of Building Ht. (W.E.I.M) | ||
| Note:-Three basements if used for parking shall be allowed as specified in the basement norms. Stilt floors within the building envelope shall be allowed. | |||||||||
| 4. | Cinemas/Cineplex | Min.4000 | 50 | 150 | Height to be regulated by Fire and Emer-gency Equip-ment available | Shall be as per Table No. 5-2 | 1/3rd of Building Ht. | 1/3rd of Building Ht. | 1/3rd of Building Ht. |
| Note:-Three basements if used for parking shall be allowed as specified in the basement norms. Stilt floors within the building envelope shall be allowed. Canteen/food court up to15% of FAR shall be allowed. | |||||||||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| 5. | Hotel | 1000-2500 | 40 | 180 | Height to be regulated by Fire and Emer-gency Equip-ment available | Shall be as per Table No. 5-2 | 1/3rd of height of building or 6 m (W.E.I.M) | 1/3rd of height of building or 6 m (W.E.I.M) | 1/3rd of height of building or 6 m (W.E.I.M) |
| 5. | Hotel | Note:-5% of permissible FAR for party hall and 3% permissible FAR for Conference hall shall be allowed. For Conference halls/party halls/bars/restaurants etc. (Excluding entrance hotel lobby/atrium) min parking @ 1.5 ECS for 10 Sqm shall be provided. Double basements if used for parking shall be allowed as specified in the basement norms. Stilt floors within the building envelope shall be allowed. | Note:-5% of permissible FAR for party hall and 3% permissible FAR for Conference hall shall be allowed. For Conference halls/party halls/bars/restaurants etc. (Excluding entrance hotel lobby/atrium) min parking @ 1.5 ECS for 10 Sqm shall be provided. Double basements if used for parking shall be allowed as specified in the basement norms. Stilt floors within the building envelope shall be allowed. | Note:-5% of permissible FAR for party hall and 3% permissible FAR for Conference hall shall be allowed. For Conference halls/party halls/bars/restaurants etc. (Excluding entrance hotel lobby/atrium) min parking @ 1.5 ECS for 10 Sqm shall be provided. Double basements if used for parking shall be allowed as specified in the basement norms. Stilt floors within the building envelope shall be allowed. | Note:-5% of permissible FAR for party hall and 3% permissible FAR for Conference hall shall be allowed. For Conference halls/party halls/bars/restaurants etc. (Excluding entrance hotel lobby/atrium) min parking @ 1.5 ECS for 10 Sqm shall be provided. Double basements if used for parking shall be allowed as specified in the basement norms. Stilt floors within the building envelope shall be allowed. | Note:-5% of permissible FAR for party hall and 3% permissible FAR for Conference hall shall be allowed. For Conference halls/party halls/bars/restaurants etc. (Excluding entrance hotel lobby/atrium) min parking @ 1.5 ECS for 10 Sqm shall be provided. Double basements if used for parking shall be allowed as specified in the basement norms. Stilt floors within the building envelope shall be allowed. | Note:-5% of permissible FAR for party hall and 3% permissible FAR for Conference hall shall be allowed. For Conference halls/party halls/bars/restaurants etc. (Excluding entrance hotel lobby/atrium) min parking @ 1.5 ECS for 10 Sqm shall be provided. Double basements if used for parking shall be allowed as specified in the basement norms. Stilt floors within the building envelope shall be allowed. |
| 1 | 2 | 3 | 4 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| INDUSTRIAL USE | INDUSTRIAL USE | INDUSTRIAL USE | INDUSTRIAL USE | INDUSTRIAL USE | INDUSTRIAL USE | INDUSTRIAL USE | INDUSTRIAL USE | INDUSTRIAL USE | INDUSTRIAL USE | INDUSTRIAL USE |
| 10. | Flatted Group Industry and Service Centre | Min. 2000 | Min. 2000 | 30 | 120 | 20 | Shall be as per Table No. 5-2 | 1/3rd of height of building or 6M (W.E.I.M) | 1/3rd of height of building or 6M (W.E.I.M) | 1/3rd of height of building or 6M (W.E.I.M) |
| 10. | Flatted Group Industry and Service Centre | Note:-Basement up to the building envelop line to the maximum extent of 50% plot area shall be allowed and if used for parking and services should not be counted in FAR. | Note:-Basement up to the building envelop line to the maximum extent of 50% plot area shall be allowed and if used for parking and services should not be counted in FAR. | Note:-Basement up to the building envelop line to the maximum extent of 50% plot area shall be allowed and if used for parking and services should not be counted in FAR. | Note:-Basement up to the building envelop line to the maximum extent of 50% plot area shall be allowed and if used for parking and services should not be counted in FAR. | Note:-Basement up to the building envelop line to the maximum extent of 50% plot area shall be allowed and if used for parking and services should not be counted in FAR. | Note:-Basement up to the building envelop line to the maximum extent of 50% plot area shall be allowed and if used for parking and services should not be counted in FAR. | Note:-Basement up to the building envelop line to the maximum extent of 50% plot area shall be allowed and if used for parking and services should not be counted in FAR. | Note:-Basement up to the building envelop line to the maximum extent of 50% plot area shall be allowed and if used for parking and services should not be counted in FAR. | Note:-Basement up to the building envelop line to the maximum extent of 50% plot area shall be allowed and if used for parking and services should not be counted in FAR. |
| 11. | Light and Service Industry | 100 up to500 | 100 up to500 | 60 | 120 | 12 | Shall be as per Table No. 5-2 | 3.0 | 3.0 | N |
| 11. | Light and Service Industry | 500 up to4000 |
| 1 | 2 | 3 | 4 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| 18. | High/Higher Secon-dary School | Min. 7500 | Min. 7500 | 35 | 140 | 18 | Shall be as per Table No. 5-2 | 4.0 or 1/3rd of Building Ht. or B.L. (W.E.I.M) | 4.0 or 1/3rd of Building Ht. or B.L. (W.E.I.M) | 4.0 or 1/3rd of Building Ht. or B.L. (W.E.I.M) |
| 18. | High/Higher Secon-dary School | Note:-Stilt floors within the building envelope shall be allowed. Single basement within the building envelope shall be allowed for parking as specified in the basement norms. | Note:-Stilt floors within the building envelope shall be allowed. Single basement within the building envelope shall be allowed for parking as specified in the basement norms. | Note:-Stilt floors within the building envelope shall be allowed. Single basement within the building envelope shall be allowed for parking as specified in the basement norms. | Note:-Stilt floors within the building envelope shall be allowed. Single basement within the building envelope shall be allowed for parking as specified in the basement norms. | Note:-Stilt floors within the building envelope shall be allowed. Single basement within the building envelope shall be allowed for parking as specified in the basement norms. | Note:-Stilt floors within the building envelope shall be allowed. Single basement within the building envelope shall be allowed for parking as specified in the basement norms. | Note:-Stilt floors within the building envelope shall be allowed. Single basement within the building envelope shall be allowed for parking as specified in the basement norms. | Note:-Stilt floors within the building envelope shall be allowed. Single basement within the building envelope shall be allowed for parking as specified in the basement norms. | Note:-Stilt floors within the building envelope shall be allowed. Single basement within the building envelope shall be allowed for parking as specified in the basement norms. |
| 19. | College | Min. 30000 | Min. 30000 | 25 | 100 | 18 | Shall be as per Table No. 5-2 | 5.0 or 1/3rd of Building Ht. or B.L. (W.E.I.M) | 5.0 or 1/3rd of Building Ht. or B.L. (W.E.I.M) | 5.0 or 1/3rd of Building Ht. or B.L. (W.E.I.M) |
| 19. | College | Note:-Stilt floors within the building envelope shall be allowed. Single basement within the building envelope shall be allowed for parking as specified in the basement norms. | Note:-Stilt floors within the building envelope shall be allowed. Single basement within the building envelope shall be allowed for parking as specified in the basement norms. |
| 1 | 2 | 3 | 4 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| Basement after utilization for Parking; Services Requirements such as air conditioning plant and equipment, water storage, boiler, electric sub-station, HT. & LT panel rooms, transformer compartment, control room, pump house, generator room; staff locker room, staff changing room, staff dining facilities without kitchen facility, Central sterile supply dept., back end office; Other Mechanical Services; Installation of Electrical and fire-fighting equipment's; and other services like kitchen, laundry and radiology lab and other essential services required for the maintenance/functioning of the building may be used for healthcare facilities with prior approval of the concerned agencies. Other controls related to basements etc. are given in end of this chapter. The bed count of a Health Facility may be allowed as per permissible FAR. Environment clearances shall be made mandatory considering that bio-wastes are generated. Environment clearances are mandatory as per the prevailing regulations related to the environment. Zero discharge for sewerage shall be enforced at the cost of the promoters and post treatment water can be used by premises for its needs of horticulture, flushing, coolant tower, washing or disposal to other construction sites. These issues concerned the local bodies and can be dealt accordingly as per existing regulations as the time of sanctioning the plan. The additional power requirements shall be met by power supply from grid and till such time by means of suitable captive generation. | Basement after utilization for Parking; Services Requirements such as air conditioning plant and equipment, water storage, boiler, electric sub-station, HT. & LT panel rooms, transformer compartment, control room, pump house, generator room; staff locker room, staff changing room, staff dining facilities without kitchen facility, Central sterile supply dept., back end office; Other Mechanical Services; Installation of Electrical and fire-fighting equipment's; and other services like kitchen, laundry and radiology lab and other essential services required for the maintenance/functioning of the building may be used for healthcare facilities with prior approval of the concerned agencies. Other controls related to basements etc. are given in end of this chapter. The bed count of a Health Facility may be allowed as per permissible FAR. Environment clearances shall be made mandatory considering that bio-wastes are generated. Environment clearances are mandatory as per the prevailing regulations related to the environment. Zero discharge for sewerage shall be enforced at the cost of the promoters and post treatment water can be used by premises for its needs of horticulture, flushing, coolant tower, washing or disposal to other construction sites. These issues concerned the local bodies and can be dealt accordingly as per existing regulations as the time of sanctioning the plan. The additional power requirements shall be met by power supply from grid and till such time by means of suitable captive generation. |
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | |
| Up to 15% of maximum FAR can be utilized for residential use/hostel for essential staff and student accommodation, in Fire Training Institute/College. Other controls related to basements etc. are as per regulations. | ||||||||||
| Non-Residential Premises | ||||||||||
| 30. | Hostel | Min. 750 | 30 | 120 | 15 | Shall be as per Table No. 5-2 | 1/3rd of Building Ht. | 1/3rd of Building Ht. | 1/3rd of Building Ht. | |
| Note:-Stilt floors within the building envelope shall be allowed. Single basement within the building envelope shall be allowed for parking as specified in the basement norms. | ||||||||||
| 31. | Guest House, Boarding House or Lodging House | Min. 500 | 30 | 120 | 18 | Shall be as per Table No. 5-2 | 1/3rd of Building Ht. | 1/3rd of Building Ht. | 1/3rd of Building Ht. | |
| Note:-Stilt floors within the building envelope shall be allowed. Single basement within the building envelope shall be allowed for parking as specified in the basement norms. | ||||||||||
| Other Uses | ||||||||||
| Petrol Pumps: The general regulations for Petrol Pumps shall be as per guidelines issued by Ministry of Road, Transport & Highways. · New petrol pump shall not be located on any road having R/W less than 15 m | ||||||||||
| 32. | Filling Station | The frontage & depth of the plot shall be as per guide-lines issued by Ministry of Road, Transport & High-ways. | 10 | 10 | 6 | Shall be as per Table No. 5-2 | N | N | N | |
| Filling Cum Service Station | 20 | 20 | 6 | Shall be as per Table No. 5-2 | N | N | N | |||
| Comp-ressed Natural Gas (CNG) Mother Station | 20 | 20 | 4.5 | Shall be as per Table No. 5-2 | N | N | N | |||
| Other Regulations: Shall be accepted to explosive/Fire Dept. Ground Coverage will exclude canopy area. Mezzanine if provided will be counted in FAR. | ||||||||||
Note:—
· The height. of stilt should be maximum 3.0 m below soffit of beam.
· In case stilt parking is provided within commercial or PSP building envelope in combination with ground floor. Height of stilt floor in this case shall not be more than 3.0 m. below beam soffit.