Every bathroom or water closet shall—
(a) Be so situated that at least one of its walls open to external air and shall have a minimum opening in the form of window or ventilation to the extent of 0.37 sq. m.
(b) Not to be directly over any room other than another latrine, washing place, bath or terrace unless it has a watertight floor.
(c) Have the platform or seat made of watertight non-absorbent material.
(d) Be enclosed by walls or partitions and the surface of every such wall partition shall be finished with a smooth impervious material to a height of not less than 1.0 m. above the floor of such a room.
(e) Be provided with an impervious floor covering, sloping towards the drain with a suitable grade and not towards Verandah or any other place.
(f) Have a window or ventilator, opening to a shaft or open space, of area not less than 0.3 Sq. m. with side not less than 0.3 m.
(g) No room containing water closets shall be used for any purpose except as a lavatory.
(h) Every water closed and/or a set of urinals shall have flushing cistern of adequate capacity attached to it.
(i) A toilet on terrace having a maximum of 2.2 m height shall be permitted to condition that the area of toilet be counted in FAR.
(j) All the sewerage outlets shall be connected to the Municipal Sewerage system. Where no such system exists,
No. 39-4] The J&K Official Gazette, 24th Dec., 2021/3rd Agra., 1943. 111
a septic tank shall be provided within the plot conforming to the requirements.