5.2.1 Minimum Space/Plot Area requirements, Maximum Ground Coverage, Setbacks/Setbacks, Permissible Floor Area Ratio (FAR) and Maximum Height.
5.2.1.1 The regulations for Residential Use in terms of Plot Area, Ground Coverage, FAR and Setbacks shall be as given below:— Table No. 5—3
| A. Minimum Setbacks/Setbacks, Maximum Ground Coverage and No. of Storeys as per Plot Area Range for R1, R2 categories of Residential Use. | ||||||||
| S.No. | Area(In Sq. m) | Max.GroundCoverage | No. ofStoreys | Type ofConst. | Set Back Limits(Minimum) in metres | |||
| Front | Rear | Side | Side | |||||
| 1. | Up to 75 | 75% | G+2 | RoW | Shall be as per table No. 5-2 | 0 | 0 | 0 |
| 2. | Above75-125 | 75% | G+2 | RoW | 1.5 | 0 | 0 | |
| 3. | Above125-275 | 65% | G+2 | RoW | 2.0 | 0 | 0 | |
| 4. | Above275-350 | 55% | G+2 | Semi-detached | 2.0 | 2.0 | 0 | |
| 5. | Above350-450 | 50% | G+2 | Semi-detached | 2.0 | 2.0 | 0 | |
| 6. | Above450-600 | 45% | G+2 | Detached | 3.0 | 3.0 | 2.0 | |
| 7. | Above600-1000 | 40% | G+2 | Detached | 3.0 | 3.0 | 2.0 | |
| 8. | Above1000 | 35% | G+2 | Detached | 3.0 | 3.0 | 2.0 | |
| V. Any area within building envelope provided for parking on ground shall not be counted in covered floor area and the same area shall be allowed for habitable purpose on 3rd floor.VI. In case stilt parking is provided within building envelope in combination with ground floor, the area under parking shall be allowed for habitation on 3rd floor. Height of stilt floor in this case shall not be more than 3m.VII. Basements shall not be allowed in row housing, but single basement shall be allowed in detached and semi-detached housing subject to fulfilment of basement norms as per National Building Code.VIII. Basements in individual plotted housing shall be counted towards FAR and ground coverage.IX. Single basement shall be allowed within the building envelope ensuring structural safety with maximum height of 3.0 m from finished floor to soffit of beam.X. Porches up to an area of 17 Sqm shall be allowed in side setbacks only and no construction over such porches shall be allowed.XI. Areas under porch shall be calculated @ 50% for coverage.XII. Stilt floor shall be allowed on roads not less than 6.0 m Width. | ||||||
| B. Regulations for R3—Group Housing (Flatted Development) | ||||||
| S.No. | Plot Area (Sq. m) | Max. Ground Coverage | Max. FAR and Dwelling Units per ha | Max. Height (m) | Min. Setbacks Rear & Both sides (Each Side) | Tower to Tower Distance |
| 1. | 4000—8000 | 30% | 175 | Height to be regulated by Fire and Emergency Equipment available. | 1/3rd of height of building or 7.5m or building line of the abutting road whichever is more. | Minimum 6M all around up to 40 m height and minimum 9m allround above 40m height. |
| 2. | Above 8000 | 30% | 225 | 1/3rd of height of building or 7.5 m or building line of the abutting road whichever is more. | Minimum 6M all around up to 40 m height and minimum 9 m all round above 40m height. | |
Note:—
I. The Group Housing Scheme shall be subject to Reservation Policy for EWS/LIG Housing for Urban Poor as per J&K Housing, Affordable Housing, Slum Redevelopment and Rehabilitation and Township Policy, 2020.
II. F. A. R./Density required for EWS shall not be counted in overall FAR of the Group Housing Scheme and shall be subject to the fulfilment of parking norms for EWS as well if provided within the Group Housing Scheme. Allotment under EWS scheme shall be made strictly as per the J&K Housing, Affordable Housing, Slum Redevelopment and Rehabilitation and Township Policy, 2020.
III. Bye-laws for affordable housing shall be as per J&K Housing, Affordable Housing, Slum Redevelopment and Rehabilitation and Township Policy, 2020.
IV. Maximum Commercial/Public, Semi-public use in Group Housing/Flatted Development shall be 10% of the total site/scheme area.
V. Security room may be allowed at the entrance gate up to a maximum built up area of 30 Sqm (up to 3.5m height) after maintaining the RoW of road and shall be counted as FAR.
VI. Minimum floor height from finished floor for any habitable space shall be 2.75m.
VII. Built up area (Unit Area) of apartment for calculation of ECS shall be excluding common service areas. Any service area within apartment shall be counted in built up area. Balconies and Verandas shall be counted @ 50% in FAR.
VIII. If there are any bends or curves on the approach road within the plot, a sufficient width shall be provided at the curve to enable the fire tenders to turn, the turning circle being at least of 9.0 m radius. Where entry to the plot is through a slip road the gate width shall not be less than 9.0 m for entry of the firefighting appliances.
IX. The internal access to the building within the plot and open spaces on its all sides shall not be less than 6 m width and the layout for the same shall be done in consultation with Chief Fire Officer, Fire Service and the same shall be reinforced to ensure safety of the fire equipment and capable of taking the weight of Fire Engine, weighing up to 45 tons. The said open space shall be kept free of obstructions and shall be motorable.
71
X. Main entrances to the premises shall be of 9.0 m width to allow easy access to the fire engine and in no case, it shall measure less than 6 m. The entrance gate shall fold back against the compound wall of the premises, thus leaving the exterior access way within the plot free for movement of fire service vehicles. If archway is provided over the main entrance the height of the archway shall not be at a height less than 5m.
XI. The catalogue for sale of apartments shall be similar to the basic plan approved by the Authority.
XII. No deviation in the plan shall be allowed once the apartments are sold in part or whole.
XIII. No common areas like corridors, stairs, lifts, lobbies shall be allowed to be sold to a particular person or a group of persons after the apartments are sold in part or whole.
XIV. No apartment holder shall be allowed to have extra rights on common spaces.
XV. Common spaces shall include all green spaces, children’s parks, play grounds, sports facilities, areas which are of common use of the apartment owners forming part of the sanctioned plan under bye-laws of the Authority.
XVI. Any additional space not counted in the permissible floor space shall also be treated as common areas.
XVII. Designated parking spaces shall be allotted to apartment holders.
XVIII. Height Exemptions:
a. Roof tanks and their supports not exceeding 1.0 m. in height.
b. Ventilating, air conditioning and lift rooms and similar service equipment.
c. Stair covered with mumty not exceeding 3.00 m. in height.
d. Chimneys and parapet wall and architectural features not exceeding 1.50 m. in height unless the aggregate area of such structures exceeds 1/3rd of the roof area of the building on which they are erected. All such appurtenant structures shall be camouflaged to achieve streamlined aesthetics.