5.2.2.1 Private Parking (On the plot) :
5.2.2.1.1 General Requirements for Parking :
-
Parking requirement for a Mixed-Use development shall be calculated on pro rata basis of the FAR consumed specific to the different uses.
-
Parking is permitted at any floor level above ground and at more levels or basement as per required parking, with provision of vehicular ramp/mechanized means/car lifts.
-
Parking area includes parking space, driveway and aisles but excludes approach road, vehicular lift and vehicular ramps.
-
Parking layouts with minimum size requirements for parking space, driveways and access lanes shall be provided as mentioned ahead.
-
Parking shall be permitted in side or rear Setbacks except in Approach Road as per Regulation 5.2.1.5.
89
-
Parking area should be retained as effective parking space and shall be maintained with light and ventilation system if provided in an enclosed area.
-
In cases where misuse of parking space is noticed, the use of the entire building shall be discontinued by the BPIA. Building use shall be permitted only after the required parking spaces are provided. High penalty shall be levied considering the period of misuse of the parking space and the benefit derived out of misuse as decided by the BPIA from time to time.
-
If parking is provided on a terrace with vehicular elevator, vehicular ramp is not necessary if parking space is provided with provision of floor sprinklers.
-
Parking shall not be permitted within an Atrium.
-
At the time of approval an agreement/affidavit regarding the areas in basement/stilts/open shown for parking shall be furnished by the applicant to the concerned authority mentioning that aforesaid part (parking) shall not be sold to any body and it shall remain for parking only, this area shall remain in joint possession of the occupants of the building. In case of violation concerned authority will be authorized to demolish any such construction with or without prior notice.
5.2.2.1.2 General Space Requirement for Parking :
1. Location
The parking spaces can be provided in basement or on a floor supported by stilts or on upper floors/podium and uncovered spaces in a plot. However, no parking spaces will be permitted in the Setback open spaces as required to be provided as per Regulation No. 5.2.4.7 & 5.2.4.8.
-
The deck parking inclusive of car lifts & passages shall be counted in FAR.
-
Area of Parking Space: The area of parking spaces shall be provided as given below:—
Table No. 5—5 Parking requirements
| S. No. | Use | Parking requirement |
| 1 | 2 | 3 |
| 1 | Residential | |
| Residential (R1) for Plots more than 50 sq. m. | Minimum Parking requirement for individual plotted housing shall be calculated @ 0.25 ECS for every 40 Sq. m. of built-up area. | |
| Group Housing | · Up to 50 Sq. m/EWS 0.25 ECS · Above 50 Sq. m to less than 100 Sq. m 0.5 ECS · From 100 Sq. m up to 120 Sq. m 1.0 ECS · Above 120 Sq. m up to 180 Sq. m 1.5 ECS · Above 180 Sq. m 2.0 ECS | |
| 2 | Commercial | |
| Single Shop | · 2.0 ECS/100 Sq. m F.A. (if F.A. exceeds 50 sq.m) | |
| Shopping Cluster | · 2.0 ECS/100 Sq. m F.A. | |
| Commercial Complex | · 2.0 ECS/100 Sq. m F.A. up to plot area 4000 Sq. m · 2.5 ECS/100 Sq. m F.A. above 4000 Sq. m plot area | |
| Cinema/Cineplex | · 1 ECS for 3 seats of Cinema · 2 ECS/100 Sq. m F.A. for other uses incidental to Cinema/Cineplex | |
| Hotel | · 1 ECS for 3 Guest Rooms · 2 ECS/100 Sq. m F.A. for other uses incidental to Hotel · For Conference Halls/Party Halls/Bars/ Restaurant (excluding entrance Hotel lobby/Atrium) min. parking @ 1.5 ECS/10 Sq. m shall be provided | |
| Mall/Multiplexes | · 1 ECS for 3 seats of Cinema | |
| 1 | 2 | 3 |
| · 2 ECS/100 Sq. m for additional area under uses incidental to Malls/ Multiplexes · For Party Halls min. parking @1.5ECS for 10 Sq. m shall be provided | ||
| Banquet Hall/CommunityCentre/Janjghar | For plots min. 6000 Sq. m up to less than 10000 Sq. m · Min. 150 ECS up to 1000 Sq. m of built-up area. · For more than 1000 Sq. m an additional parking @ 1.5 ECS/10 Sq. m shall be provided. For plots above 10000 Sq. m · In addition to above category, an additional parking @ 6 ECS/500 Sq. m plot area shall be provided | |
| Restaurant/Fast Food Bar | 1.0 ECS for every 3 seats | |
| 3. | Public-Semi-public/Institutional Use | |
| Offices:General/GovernmentOffices/Integrated Office Complex | · 2.0 ECS/100 Sq. m F.A. | |
| 4. | Education | |
| Primary/Middle/ Secondary & Hr. Sec. schools | · For the Administrative & public Area of the School 1.5 ECS per 100 Sq. m built-up area or part thereof. · For Every 3 Class Room-1 LCV | |
| College/ResearchCentre | · For the Administrative & public Area of the School 1.5 ECS per 100 Sq. m built-up area or part thereof. · For Every 3 Class Room-1 LCV & 1ECS | |
| Coaching Classes | For every 20 Students-1 ECS | |
| 5. | Hospitals/HealthCentre/NursingHome/Radio Diagnostic Centre/ Microbiological/pathological | · 2.0 ECS/100 Sq. m F.A. |
| 1 | 2 | 3 | |||||
| 6. | Religious Premises | · 1 ECS/100 Sq. m F.A. | |||||
| 7. | Police Post/Police Station/Fire Station/Post & Telegram Office/Bank/GeneralPublic-Semi-Public Premises | · 2.0 ECS/100 Sq. m F.A. | |||||
| 8. | Hostel | · 1.5 ECS/100 Sq. m F.A. | |||||
| 9. | Guest House, Boarding House and Lodging House | · 2.0 ECS/100 Sq. m F.A. | |||||
| ECS value shall be taken as: | |||||||
| S. No | On Ground | Basement | Stilts | Mechanized | Rotating | ||
| 1 | 18.0 Sq. m/ECS | 28.0 Sq. m/ ECS | 23.0 Sq. m/ ECS | 16.0 Sq. m | 5.0 Sq. m | ||
For Four-wheeler :
-
Basement parking shall be permitted on plot abutting Minimum Road width 12 m or above.
-
Basement parking shall be permitted on plot having minimum plot width 18 m or more and minimum plot depth 20 m or more.
-
Side and Rear Setbacks for Basement parking shall be as per Regulation 5.2.4.1, 5.2.4.2.
-
Minimum driveway 4.5 m for one-way circulation, 6 m for two-way circulation.
-
Minimum Four-wheeler bay size shall be 2.5 m x 5 m.
-
The height of basements from floor to ceiling shall be as per Regulation no. 5.2.4.7. The ramp within Setbacks shall be permissible subject to free and convenient movement of fire tender.
-
Adequate fire safety, light and ventilation and air change through mechanical means shall be provided.
-
Permissible uses in basements shall be as per Regulation No. 5.2.4.7.
-
Basement parking can also be Mechanized instead of conventional ramps.
93
- Combination of two-wheeler and four-wheeler vehicle parking shall be allowed.
5.2.2.1.3 Common Parking Space :
If the total parking space as required by these Regulations is provided by a group of property owners for their mutual benefit within a distance of 500 m from their property, such common use of space for parking may be construed as meeting the offstreet parking requirements under these Regulations subject to the approval of the concerned area authority. If such common parking space is proposed for a group of buildings, the owners of such buildings shall submit a layout thereof and also a registered undertaking stating that the area earmarked for the parking space will not be built upon and will be utilized for parking purpose only.
5.2.2.1.4 Parking for Non-Motorized Vehicular Zone (NMV Zones) :
For NMV Zones required parking space shall be provided as per Regulation No. 5.2.5.1.2 in the premises itself. If the required parking space cannot be provided, then plot owners can pay parking facility charges as per Regulation No. 5.2.7.5.