Conversion of existing cinema hall to multiplex complex is allowed subject to complying with the requirements given hereunder.
100.Site Requirements for Multiplex Complexes:
(1) The minimum size of plot for a Multiplex shall be 3000sq. m.
(2) The site shall abut to an existing road whose width shall be not less than 18m.
(3) The abutting road has to be black-topped with minimum 2 lane carriageway. Service roads are required for sites abutting 30m and above roads and approach shall be allowed only through service road. The width of the service road shall be minimum 7m with minimum 2 lane black topped carriageway and shall be undertaken by the owners of such buildings to the extent of the width of their site.
101.Location Criteria:
(1) The location criteria of a Multiplex Complex shall be the same as given in the Andhra Pradesh Cinemas (Regulation) Act, 1955 and in addition to this, it shall comply with Clause 3.2 of Part 4 of National Building Code (wherever applicable).
(2) Where zoning regulations of a statutory Plan/Scheme are in force, the location of multiplex complex shall be governed as per such zoning regulations.
(3) Multiplex complex may be permitted in a zone or scheme declared as tourism zone/area along with other recreational facilities.
(4) Multiplex Complex shall not be allowed in
(a) Congested areas;
(b) Settlement areas/Abadi/Gram khantam areas;
(c) Areas restricted for High-rise buildings;
(d) Abutting to major road junctions of above 18m wide;
(e) Pure residential areas/localities.
(5) Government may by Notification, declare certain roads/areas in any APCRDA/MRDA/UDA/ULB area where Multiplex Complex shall not be allowed.
102.Documents to be submitted:
In addition to the documents required to be submitted for sanction of building permission of High rise building, the following are also mandatory to examine the Multiplex Complex Application.
(1) Prior No Objection Certificate shall be submitted from the Airport Authority of India (if applicable).
(2) Prior No Objection Certificate shall be submitted from the Director General of Disaster Response and Fire Services Department. The fire safety requirements
shall be duly certified by a fire engineer.
(3) Prior No Objection Certificate from the Police Department [Traffic] shall be submitted.
(4) Traffic Impact Study Report and Traffic Management Plan for the proposed Multiplex Complex prepared by a qualified Traffic Engineer shall be submitted along with application.
103.Building Requirements:
(1) Every application to construct or reconstruct a Multiplex Complex shall be made in the prescribed form and accompanied by detailed plans and floor plans of all floors drawn by a registered architect, along with complete set of structural drawings and detailed specifications duly certified by a qualified structural engineer.
(2) The building bulk, coverage and height shall be governed by the minimum allround setbacks to be left, the organized open spaces to be left and the height restrictions imposed by the Airport authority (if applicable)/Defense authorities (if applicable) and Fire Services Department and the Area-level Impact fee on built up area required to be paid, as applicable.
(3) The maximum height of the block/portion wherein the Multiplex screens are set up shall not exceed 30m;
(4) In case of sites located in Gram Panchayat areas and outside Development Authority areas, the maximum height of all blocks permissible shall be 30m;
(5) In case of two or more blocks in the same site, the space between the two blocks shall be as given in Column (D) of the Table given below;
(6) For heights of blocks above 30m and up to 45m, the minimum abutting road width shall be 24m while for blocks of height above 45m, the minimum abutting road width shall be 30m.
(7) The minimum all-round setbacks for a multiplex Complex shall be as follows.
(8) No relaxation in the minimum all-round setbacks or transfer of setbacks shall be allowed.
TABLE - 23
Minimum all-round setbacks for a Multiplex Complex
| S. No. | Height of the Building (m) | Minimum front open space (m) | Minimum open space on remaining sides (m ) |
| (A) | (B) | (C) | (D) |
| 1 | Up to 15 | 12 | 6 |
| 2 | Above 15m & Up to 21m | 12 | 7 |
| 3 | Above 21m & Up to 24m | 8 | |
| 4 | Above 24 m & up to 27m | 9 | |
| 5 | Above 27m & Up to 30m | 10 | |
| 6 | Above 30m & up to 35m | 11 | |
| 7 | Above 35m & Up to40m | 12 | |
| 8 | Above 40m & up to 45m | 13 | 13 |
| 9 | Above 45m & up to 50m | 14 | 14 |
| 10 | Above 50m | 15 | 16 |
104.Construction requirements:
(1) The building requirements, building services, specifications and standards specified in the National Building Code, 2005 shall be complied with.
(2) Construction of such buildings shall be undertaken by owners by engaging registered architect, licensed builder, fire engineer and licensed structural engineer.
(3) The designs and building plans shall be countersigned by the owner, licensed builder, registered architect, licensed engineer, qualified & licensed structural Engineer and a fire engineer who shall be responsible for the supervision, structural safety, fire safety and compliance of the specifications for such buildings.
(4) Buildings shall be designed for earth quake resistance and resistance for other natural hazards. The Completion Certificate obtained from the Licensed Technical Personnel shall mention that the norms have been followed in the design and construction of buildings for making the buildings earthquake resistant, compliance with structural safety and fire safety requirements as per the relevant provisions of National Building Code & Andhra Pradesh Fire Service Act, 1999.
(5) The exit and fire safety requirements shall be in accordance with Part IV of National Building Code of India. The fire safety measures shall be undertaken by engaging the services of a fire protection engineer.
(6) The following minimum Fire Fighting Installations are to be provided as per Table 23, Part - 4 of National Building Code of India, 2005:
Table - 24
Fire Fighting Installations
| Sl. No. | Fire Fighting Installation |
|---|---|
| (A) | (B) |
| 1 | Fire Extinguishers as per IS 2190 |
| 2 | Hose reel |
| 3 | Wet riser |
| 4 | Yard hydrant |
| 5 | Automatic sprinkler system in entire Building |
| 6 | Automatic detection and alarm system in entire Building (except Cellars) |
| 7 | Manually operated electrical alarm system in entire Building (except Cellars) |
| 8 | Underground static water tank of 2,00,000 Liters capacity |
| 9 | Terrace tank of 20,000 Liters capacity |
| 10 | Two Electrical Main pumps of 2850 LPM capacity |
| 11 | Diesel pump (Standby of 2850 LPM capacity |
| 12 | Electric Jockey pump of 180 LPM capacity |
(7) The work of other building services like sanitation, plumbing, lifts, electrical installations, and other utility services shall as per National Building Code standards and shall be executed under the planning, design and supervision of qualified and competent technical personnel.
(8) The means of escape shall be provided as per the Clause 4 (Exit Requirements), Part 4 of National Building Code of India.
TABLE - 25
Means of escape and Exit Requirements for Multiplex Complex
| S. No. | Item | Clause of Part 4 of NBC |
|---|---|---|
| (A) | (B) | (C) |
| 1 | Capacities of Exists | 4.4 |
| 2 | Arrangement of Exits | 4.5 |
| 3 | Number of Exits | 4.6 |
| 4 | Doorways | 4.7 |
| 5 | Corridors and Passageways | 4.8 |
| 6 | Internal Staircases | 4.9 |
| 7 | Pressurization of Staircases | 4.10 |
| 8 | External Staircases | 4.11 |
| 9 | Horizontal Exits | 4.12 |
| 10 | Fire Tower | 4.13 |
| 11 | Ramps | 4.14 |
(9) Smoke Management
The following measures are to be provided to prevent the spread of smoke easily to the other floors, which may affect the life safety of the occupants, particularly, the Cinema viewers:
(a) For Types 1 to 3 constructions as given Clause 3.3 in the National Building Code (Part-IV), a doorway or opening in a separating wall on any floor shall be limited to 5.6sq.m in area with a maximum height/width of 2.75m. Every wall opening shall be protected with fire-resisting doors having the fire rating of not less than 2 h in accordance with accepted standard [4(7)]. All openings in the floors shall be protected by vertical enclosures extending above and below such openings, the walls of such enclosures having a fire resistance of not less than 2 h and all openings therein being protected with a fire resisting assembly as specified in clause 3.4.8 & 3.4.9 of Part-4 of NBC.
(b)Openings in walls or floors which are necessary to be provided to allow passages of all building services like cables, electrical wirings, telephone cables, plumbing pipes, etc, shall be protected by enclosure in the form of ducts/shafts having a fire resistance not less than 2 h . The inspection door for electrical shafts/ducts shall not be less than2 h and for other services shafts/ducts, the same shall have fire resistance not less than 1 h. Medium and low voltage wiring running in shafts/ducts, shall either be armored type or run through metal conduits. Further, the space between the conduits pipes and the walls/slabs shall be filled in by a filter material having fire resistance rating of not less than 1 h as per clause 3.4.8.3 of Part-4 of National Building Code.
(c) Openings in separating walls and floors-Attention shall be paid to all such factors as will limit fire spread to these opening and maintain fire rating of the structural member. Every wall opening shall be protected with Fire resisting doors having fire rating of not less than two hours. All openings in the floors shall be protected by vertical enclosures extending above and below such openings, the wall of such enclosures having a fire resistance of not less than two hours and all openings therein being protected with a fire resisting assembly as per Clause 3, 4, 8, Part 4 of National Building Code of India, 2005.
(d)Every vertical opening between the floors shall be suitably enclosed or protected, as necessary to provide the following:
(i) Reasonable safety to the occupants while using the means or egress by preventing spread of fire, smoke, or fumes through vertical openings from floor to floor to allow occupants to complete their use of the means of egress. Further it shall be ensured to provide a clear height of 2100 MM in the passage/escape path of the occupants.
(ii) Limitation of damage to the building and its contents (Clause 3.4.8.4) Part-4 of National Building Code of India, 2005.
(e) Where openings are permitted, they shall not exceed three-fourths the area of the wall in the case of an external wall and they shall be protected with fire resisting assemblies or enclosures having fire resistance equal to that of the wall or floor in which these are situated. Such assemblies and enclosures shall also be capable of preventing the spread of smoke or fumes through the openings so as to facilitate the safe evacuation from the building in case of fire.