7 Structural Design and Safety
(1) For any building under the jurisdiction of these Rules structural design/retrofitting shall only be carried out by qualified Structural Engineer.
(2) Proof checking of various designs/reports shall be carried out by the Sanctioning Authority or an Agency authorized by the Sanctioning Authority as per Table - 12 wherever applicable.
(3) The Sanctioning Authority may consider to grant exemption for submission of working drawing, structural drawing and soil investigation report in case
(a) The height of the building is less than 10m (excluding Stilt floor).
(b) It is satisfied that in the area where the proposed construction is to be taken, similar types of structure and soil investigation reports are already available on record.
(c) If the local site conditions do not require any soil testing or if a soil testing indicates that no special structural design is required.
(d) Structural Design Basis Report (Form No. 6) has to be submitted, duly filled in case of a small building of load bearing structure up to Ground + 2 floors.
(4) Additional provisions for natural hazard prone areas:
The structural design of foundations, elements of masonry, timber, plain concrete, reinforced concrete, pre-stressed concrete and structural steel shall conform to the provisions of Part 6:Structural Design of National Building Code of India (NBC), comprising –
Section–1 Loads, Forces and Effects
Section–2 Soils and Foundations
Section–3 Timber and Bamboo
Section–4 Masonry
Section–5 Concrete
Section–6 Steel
Section–7 Prefabrication Systems, Building and Mixed/Composite Construction
(5) The same shall be followed duly taking into consideration the Indian Standards as given below:
(a)For General Structural Safety
(i) IS: 456:2000 “Code of Practice for Plain and Reinforced Concrete".
(ii) IS: 800-2007 “Code of Practice for General Construction in Steel".
(iii) IS: 801-1975 “Code of Practice for Use of Cold Formal Light Gauge Steel Structural Members in General Building Construction".
(iv) IS: 875 (Part 2):1987 “Design loads (other than earthquake) for buildings and structures Part 2 Imposed Loads". [Occupant Load a building may be considered for Design Load].
(v) IS: 875 (Part 3):1987 “Design loads (other than earthquake) for buildings and structures - Part 3 Wind Loads".
(vi) IS: 875 (Part 4):1987 “Design loads (other than earthquake) for buildings and structures- Part 4 Snow Loads".
(vii) IS: 875 (Part 5):1987 “Design loads (other than earthquake) for buildings and structures - Part 5 special loads and load combination".
(viii) IS: 883:1994 “Code of Practice for Design of Structural Timber in Building".
(ix) IS: 1904:1986 (R 2005) “Code of Practice for Structural Safety of Buildings: Foundation".
(x) IS: 1905:1987 “Code of Practice for Structural Safety of Buildings: Masonry Walls".
( x i ) IS: 2911(Part 1): Section 1: 2010 “Code of Practice for Design and Construction of Pile Foundation Section 1".
Part 1: Section 2 Bored Cast-in-situ Piles
Part 1: Section 3 Driven Precast Concrete Piles
Part 1: Section 4 Bored Precast Concrete Piles
Part 2: Timber Piles
Part 3: Under Reamed Piles
Part 4: Load Test on Piles
(b)For Cyclone/Wind Storm Protection
(i) IS: 875 (3):1987 "Code of Practice for Design Loads (other than Earthquake) for Buildings and Structures, Part 3, Wind Loads".
(ii) Guidelines (Based on IS 875 (3)-1987) for improving the Cyclonic Resistance of Low rise houses and other building.
(c)For Earthquake Protection
(i) IS: 1893 (Part 1)-2002 "Criteria for Earthquake Resistant Design of Structures (Fifth Revision)".
(ii) IS:13920-1993 "Ductile Detailing of Reinforced Concrete Structures subjected to Seismic Forces - Code of Practice".
(iii)IS:4326-2013 "Earthquake Resistant Design and Construction of Buildings - Code of Practice (Second Revision)".
(iv)IS:13828-1993 "Improving Earthquake Resistance of Low Strength Masonry Buildings - Guidelines".
(v) IS:13827:1993 "Improving Earthquake Resistance of Earthen Buildings- Guidelines".
(vi)IS:13935-2009 "Seismic Evaluation, Repair and Seismic Strengthening of Buildings -Guidelines”.
(d)For Protection of Landslide Hazard
(i) IS: 14458 (Part 1): 1998 “Guidelines for retaining wall for hill area: Part 1 Selection of type of wall”.
(ii) IS: 14458 (Part 2): 1997 “Guidelines for retaining wall for hill area: Part 2 Design of retaining/breast walls”.
(iii)IS: 14458 (Part 3): 1998 “Guidelines for retaining wall for hill area: Part 3 Construction of dry stone walls”.
(iv)IS: 14496 (Part 2): 1998 “Guidelines for preparation of landslide – Hazard zonation maps in mountainous terrains: Part 2 Macrozonation”.
Note: Where an Indian Standard or the National Building Code is referred, the latest revision of the same shall be followed except specific criteria, if any, mentioned above against that code.