For all hi-rise buildings of residential, commercial and business buildings and special buildings like assembly, institutional, industrial storage and hazardous occupancies, the following information [in addition to (d) (ii) above] shall be furnished / indicated in the building plans.
(i) Access to fire appliances/vehicles with details of vehicular turning circle/and clear motorable access way around the building;
(ii) Size (width) of main and alternate staircase along with balcony approach, corridor ventilated lobby approach;
(iii) Location and details of lift enclosures;
(iv) Location and size of fire lift;
(v) Smoke stop lobby/door where provided;
(vi) Refuse chutes; refuse chamber, services duct, etc. ;
(vii) Vehicular parking spaces;
(viii) Refuge area if any;
(ix) Details of building service-air conditioning system with position of dampers, mechanical ventilation system, electrical services, boilers, gas pipes etc.,
(x) Details of exits including provision of ramps, etc., for hospitals and special risks
(xi) Location of generator, transformer and switchgear room;
(xii) Smoke exhauster system if any;
(xiii) Details of fire alarm system network;
(xiv) Location of centralized control connecting all fire alarm system, built in fire protection arrangement & public address system etc.
(xv) Location and dimension of static water storage tank and pump room;
(xvi) Location and details of fixed fire protection installations such as sprinklers, wet risers, hose reels, drenchers, C O 2 installation etc.;
(xvii) Location and details of first aid firefighting equipment/installation;
(xviii) The proper signs/symbols and abbreviation of all firefighting systems shall be shown in diligent as per the relevant I.S. Code.
(f) Landscape Plan
Landscape plan shall indicate the circulation and parking spaces, pathways (hard surface), greenery and plantation (soft area) etc. and shall be drawn in the scale of
(i) 1:100 for plots up to 500sq.m in size
(ii) 1:500 for plots above 500sq.m.
(g)Urban Design and Architectural Control
For certain areas as well as sites abutting major roads of 30m and above, the Competent Authority may enforce urban design and architectural control. These shall be detailed out keeping in view the development requirements given in these Rules and the National Building Code norms. For this purpose, urban design and architectural control sheets / Plans approved by the Competent Authority shall be complied with.