(a) No balcony or corridor shall be permitted projecting within the mandatory open spaces/setbacks in case of non-high rise buildings. These if provided
shall be set back as per the minimum mandatory open spaces and the setbacks shall be clear from the edge of the balcony or corridor.
(b) In case of high rise buildings, the balcony projection of up to 2m may be allowed projecting on to the open spaces for upper floors from 6m height from the corresponding finished floor level onwards.
Chapter IVGeneral Space Requirements and Services
4 Standard space requirements of various parts of a building of all types including high rise buildings:
(1) Space requirement for different parts of building of different sizes:
(i) Main Building: The plinth or any part of a building or outhouse shall be so located with respect to highest road level from site so that adequate drainage of the site is assured. The height of the plinth shall be not less than 450mm from surrounding ground level.
(ii) Interior Courtyards, Covered Parking Spaces and Garages: Every interior court yard shall be raised at least 150mm above the determining ground level and shall be satisfactorily drained either by gravity or by mechanical means.
(b) Minimum Size, Width and Height of different components of residential premises shall be as given in the Table below.
TABLE - 5
Minimum Size, Width and Height of different components of residential premises
S.No.
Components of Building
Minimum Requirement for a Dwelling Unit up to 50sq.m
Minimum Requirement for a Dwelling Unit above 50sq.m
Area (sq. m)
Width (m)
Height (m)
Area (sq. m)
Width (m)
Height (m)
(A)
(B)
(C)
(D)
(E)
(F)
(G)
(H)
1
Habitable Rooms
7.5
2.1
2.75
9.5
2.4
2.75
2
Kitchen
3.3
1.8
2.75
4.5
1.8
2.75
3
Pantry
-
-
-
3.0
1.4
2.75
4
Kitchen with Dining area
7.5
2.1
2.75
7.5
2.1
2.75
5
Bathroom
1.2
1.0
2.2
1.8
1.2
2.2
6
WC
1.0
0.9
2.2
1.2
0.9
2.2
7
Combined Bath & WC
1.8
1.0
2.2
2.8
1.2
2.2
8
Door ways (Habitable rooms)
-
0.9
2.1
-
0.9
2.1
(Kitchen, Bath, WC)
-
0.75
2.0
-
0.75
2.0
9
Staircases
-
1.0
-
-
1.0
-
10
Garage
Two-wheeler garage: 1 x 2 m
18.0
3.0
2.4
11
Store room
Area and width of the store has no restriction, however Minimum Height has to be 2.20mt. If the area of the store is 9.5sqm and above, the light and ventilation clause shall also apply.
12
Projections
Permitted within the plot boundary, up to 0.75 m width. No portions of any projection whatsoever shall project outside the plot boundary.
Notes:
Provided that the minimum clear head way under any beam shall not be less than 2.4 m.
Maximum permissible height for building component mentioned above is 4.8m. However if the architect desires that more height of any building component is necessary for the functional design even to the extent of double height (to be counted twice in FAR) in the project, the same may be permitted subject to the overall permissible height of building/structure.
In case of group housing all open spaces provided either in interior or exterior shall be kept free from any erections thereon and shall open to the sky. Nothing except cornice, chhajja or weather shade (not more than 0.75m wide) shall overhang or project over the said open space so as to reduce the width to less than minimum required. Such projections shall not be allowed at height less than 2.2m from the corresponding finished floor level.
Architectural features and landscape: Architectural features like pergolas, free standing walls, trellis, onpermanent gazebos, fountains, statues, pedestal, louvers, fins, jalis, sunshade etc. in permissible building envelope area, which shall not be counted in FAR and Ground Coverage.
(2) Minimum Size and Width of different components of Non-residential premises
The minimum area for office room/shop or any other space to be used as workspace shall not be less than 6.0sq.m and with a minimum width of 2.1m.
5 Splay at road junctions, including ‘Y’ junctions:
Splay required at road junctions is given in the Table below. The area of splay would be deemed to form part of the road junction.