Chapter VIISpecial Requirement for Occupancy/land Development and Other
(General Building Requirements)
52 Category of the Building and Minimum Size of Plot
The minimum size of plots for certain categories of the building is given below:
Table – 13
Category wise Minimum Size of Plots
S. No.
Category
Minimum Plot Size (Sq. m)
(A)
(B)
(C)
1
Cinema Theatre / Convention Center/Game Center/ Kalyana Mandapam / Marriage hall / Social clubs and amenities
3000
2
Educational Institution
a
Primary/Upper Primary School
2000
b
High School / Residential School
6000
c
Junior college
4000
d
Degree College
6000
e
Technical Educational Institution
10000
3
Group Development Scheme
4000
4
Hotel, Conference Hall
2000
5
LPG Storages
500
6
Multiplex Complex
3000
7
Multi storey Car Parking
1000
8
Nursing homes
300
9
Office Buildings
500
10
Petrol pumps/Filling Stations
500
11
R & D Lab
1500
12
Row Type Housing / Row Type Shopping Precincts /Cluster Housing
1000
13
'U' Type Commercial Building
2000
14
Others
As per required standards/as prescribed by the Competent Authority
53Requirement of Approach Road for Building Sites/Plots
(1) The minimum abutting existing road width required for various uses of building activities shall be as given below.
TABLE – 14
Minimum Abutting Existing Road Width Required
Catego ry
Type/Use of Building Plot permissible
Type/Use of Building Plot permissible
Minimum abutting existing road width required (in meters)
(1)
(2)
(2)
(3)
A
SITES IN OLD/EXISTING BUILT-UP AREAS/CONGESTED AREAS /SETTLEMENT/GRAM KHANTAM/ABADI (see Annexure)
SITES IN OLD/EXISTING BUILT-UP AREAS/CONGESTED AREAS /SETTLEMENT/GRAM KHANTAM/ABADI (see Annexure)
A
(i)
All Residential (other than Group Housing) & Commercial Buildings with maximum permissible height of 10 m. except in the plots abutting to existing 60'-0" and above wide roads.
9 *
A
(ii)
For other categories the Minimum road width shall be as given in B1 Category.
9 *
B
SITES IN NEW AREAS/APPROVED LAYOUT AREAS
SITES IN NEW AREAS/APPROVED LAYOUT AREAS
B 1
(i)
Basic level social amenities like Nursery School, Primary School
9 **
B 1
(ii)
Dispensary/Diagnostic Laboratory/Poly-Clinic
9 **
B 1
(iii)
Non-High Rise (Residential) Buildings including Group Housing (Cellar and/or Stilt as permissible + maximum up to 5 floors),
9 **
B 1
(iv)
Religious Place
9 **
B 2
(i)
Commercial Complex
12
B 2
(ii)
Computer units/Office Building, ITES Complex
12
B 2
(iii)
Assembly Hall/Cinema Theater /Community Hall/ Function Hall/Marriage Hall
12
B 2
(iv)
General Industry/Godown
12
B 2
(v)
Group Development Scheme;
12
B 2
(vi)
Group Housing with more than 100 units,
12
B 2
(vii)
High Rise Buildings/Complexes up to height of 24 meters
12
B 2
(viii
High School/Middle School/Junior College/Tutorial
12
)
Institution
(xi)
Non High Rise Group Housing (Cellars as applicable + 6 floors)
(x)
Nursing Home/Hospital of not more than 20 beds
(xi)
Others not specified in the Table and all Non High-Rise buildings up to 18m height
(xii)
Petrol / Diesel / Gas Filling Station/LPG
(xiii)
Restaurant
(xvi)
Service establishment
(xv)
Workshop
B 3
(i)
General Degree and other non-professional College
18
B 3
(ii)
High-Rise buildings above 24m and up to 30m height
18
B 3
(iii)
Hospitals of more than 20 beds
18
B 3
(iv)
Multiplex Complex
18
B 3
(v)
Professional College Campus
18
B 3
(vi)
Shopping Malls (above 4000sq.m)
18
B 3
(vii)
Technical Educational Institution-Polytechnic/ITI
18
B4
All High Rise Building above 30 meters will be permitted as per the Minimum Road width and setbacks as specified in Table-18.
All High Rise Building above 30 meters will be permitted as per the Minimum Road width and setbacks as specified in Table-18.
All High Rise Building above 30 meters will be permitted as per the Minimum Road width and setbacks as specified in Table-18.
(2) *In case of Sites in Category-A, if a Site is abutting to a road which is less than 9m in width, a building may be permitted with a maximum height of 10m in such site, after leaving 4.5m from the Centre Line of such road for widening and the same shall be handed over to the Local Body and shall leave the prescribed setback as per Table-17 after the said road widening portion. No relaxations are permissible in such cases. Buildings more than 10 Mts. height may be permitted in the sites abutting the existing 18 Mts. (60’-0”) wide roads subject to complying other rules. This will transform the slum character.
(3) **In case of Sites in Category-B, if a Site is abutting to a road which is less than 9m in width, Individual Residential Building may be permitted with a maximum height of 12m, after leaving 4.5m from the Centre Line of such road for widening and the same shall be handed over to the Local Body and shall leave the prescribed setback as per Table-17 after the said road widening portion. No relaxations are permissible in such cases.
(4) In case of Notified Slums/Economically Weaker Section (EWS) Buildings, the special regulations as notified by the Government from time to time shall be followed.
(5) The sites in Old/Existing Built-up Areas/Congested Areas/Settlement/Gram Khantam/Abadi (Annexure-7) and List of Areas Prohibited for High-Rise Buildings (Annexure-8). The Government may add to or delete from the list of the said areas.
(6) In case of single plot sub-division approved by the competent authority, a means of independent access of minimum 3.6m pathway may be considered for Individual Residential Building and 6m for Non-High-Rise Group Housing Building.
54Restrictions of Building Activity
(1) Airport
(a)Buildings
(i) For building activity within the Restricted Zone/Air Funnel Zone near the airport, necessary clearance from the concerned Airport Authority shall be obtained.
(ii) The building heights and other parameters shall be regulated as per the stipulations of the Airport Authority of India as notified in Gazette of India Extraordinary (S.O.1589) dated 30-06-2008 and as amended from time to time by Ministry of Civil Aviation, Government of India.
(iii) Irrespective of their distance from the aerodrome, even beyond 22km limit from the Aerodrome Reference Point, no radio masts or similar installation exceeding 152m in height shall be erected except with the prior clearance from Civil Aviation Authorities.
(iv) In respect of any land located within 1000m from the boundary of Military Airport no building is allowed except with prior clearance from the concerned airport authority with regard to building height permissible and safe distance to be maintained between the building and boundary of the aerodrome.
(b)Other Structures
(i) Within a 5km radius of the Aerodrome Reference Point, every structure/installation/building shall be designed so as to meet the pigeon/bird proofing requirement of the Civil Aviation Authorities. Such requirement may stipulate the prohibition of any cavity, niche or other opening on the exterior of such building / installation / structure so as to prevent the nesting and habitation of pigeon or other birds.
(ii) No chimneys or smoke producing factories shall be constructed within a radius of 8km from the Airport Reference Point.
(iii) Slaughter House, Butcheries, Meat shops and Solid Waste Disposal Sites and other areas for activities like depositing of garbage which may encourage collection of high flying birds, like eagles and hawks, shall not be permitted within 10 km from the Airport Reference Point.
(2) Defense Establishments
(a) In case of Sites within 500m distance from the boundary of Defense Areas/Military Establishments prior clearance of Defense Authority shall be obtained.
(b) In case of Naval Science and Technological Laboratory (NSTL), Visakhapatnam, no building shall be allowed with in a distance of 20m from the boundary wall of NSTL, Visakhapatnam.
(3) Electrical Lines
(a) No building or part of a building shall be constructed or re-constructed and no additions or alterations to any existing building shall be made in the intervening spaces between the building and any overhead electric supply line unless as described in Table below and specified in the Indian Electricity Rules as amended from time to time.
TABLE -15Clearance from Overhead Electric Lines
Sl. No.
Type of Electrical Supply Line
Minimum Vertical clearance (m)
Minimum Horizontal clearance (m)
(A)
(B)
(C)
(D)
1
Low and Medium Voltage lines and service lines
2.5
1.2
2
High Voltage lines up to and including 11000 volts
3.7
1.2
3
High Voltage lines above 11000V and up to including 33000 volts
3.7
2.0
4
Extra High Voltage lines above 33000 volts
3.70 plus 0.30m for every additional 33000 volts or part thereof
2.00 plus 0.30m for every additional 33000 volts or part thereof
(b) In case of Electricity Tower lines, the land all along below the tower line shall be developed as green belt to an extent of the width of tower base and on either side of green belt there shall be a minimum of 10m wide roads or as defined in the Master Plan.
As per the provisions laid under the EIA Notification S.O.1533, Dt.14.9.2006 and it’s amendment dt.01.12.2009 issued by MOE&F, GOI and Notifications issued from time to time with reference to “Building / Construction Projects/Area Development Projects and Townships” complying with the following threshold limits fall under category B and are required to obtain prior Environmental Clearance (EC) from State Environmental Impact
Assessment Authority (SEIAA), Ministry of Environment and Forests, Government of India.
TABLE -16Building/Construction Projects/Area Development Projects and Townships
Project / Activity
B Category with threshold limit
Conditions, if any
(A)
(B)
(C)
8(a)
Buildings and Construction Projects
>20000sq.m and <1,50,000sq.m of built up area#
#(Built up area for covered construction; in case of facilities open to the sky, it will be the activity area
8(b)
Townships and Area Development Projects
Covering an area > 50ha and or built up area >1,50,000sq.m ++
++All Projects under Item8(b) shall be appraised as Category B1
(5) H
eritage Structures / Geo Heritage Sites
(a) In case of Sites located within the distance up to 100m from protected monuments as notified under Archeological Monuments and Ancient Sites and Remains Act 1955 and as amended no construction is allowed.
(b) For the Sites located within distance of above 100m and up to 200m from the protected monuments, the construction is allowed only after obtaining prior permission from the National Monument Authority.
(c)For the Sites located within the vicinity of any Heritage Structure / Geo Heritage Sites notified as per the respective law, the prior clearance from the concerned authority shall be obtained.
(d) For the development/redevelopment of any notified Heritage Structure/ Geo Heritage Sites the stipulations as prescribed by the respective authority shall be followed.
(6) Oil / Gas Pipelines
In case of Sites in the vicinity of Oil/Gas pipelines, clearance distance and other stipulations of the Respective Authority shall be complied with. The Oil/Gas Authorities shall also specify the clearances required stretch wise to Local Body.
(7) Railways
The distance between the Railway Property Boundary and the edge of the building shall be 30m as per Indian Railways Works Manual or as per No Objection Certificate (NOC) given by the Railway Authorities.
(8) Religious Structures
(a) In case of Sites located within a radius of 100m from the notified religious structure from time to time by the sanctioning authority, the construction is allowed up to 12m height only.
(b) For the Sites located within a radius of above 100m and up to 300m from the notified religious structure as notified from time to time, only non-high rise structures are allowed.
(9) Site and Land Use Pattern
Notwithstanding anything contained in these Rules, no building permit on any site shall be sanctioned if:
(a) the proposed land use does not correspond to the land use in the Development Plan/Master Plan/Layout Plan or any draft/sanctioned plan for the area or the zoning regulations.
(b) the use of building or place will be a source of annoyance to, or injurious to the health of the inhabitants of the neighbourhood.
(c)the construction of any building is for public worship, which in the opinion of the Sanctioning Authority will affect the religious feelings of any class or persons in the vicinity thereof.
(d) there is deposited refuse, excreta or other offensive matter, which is considered objectionable, until such refuse, excreta or other offensive matter has been removed there from and the plot has been prepared or left in a manner suitable for land development, redevelopment or building purpose.
(e) it comprises or includes a pit, quarry or other similar excavation or any part thereof unless such plot has been prepared or left in a manner or condition suitable for land development or redevelopment or building purposes.
(f) it is liable to flood or on a slope forming an angle of more than 45 degrees with the horizontal or on soil unsuitable for percolation or on area shown as floodable area in any plan/scheme or in sandy beds, unless it is proved by the owner that construction of such a building will not be dangerous or injurious to health and the site will not be subjected to flooding or erosion, or cause undue expenditure of public funds in the provision of roads, sewers, sanitation, water supply or other public services.
(g) it is for any land development or redevelopment of land or construction in any area notified by Government of India as Coastal Regulation Zone under the Environment (Protection) Act, 1986 (29 of 1986) and Rules made there under and it shall be subject to the restrictions that may be imposed by Government of India contained in the said notification as amended from time to time.
(h) it is in areas of natural waterways or drains and if the building is to be constructed over or under a municipal drain, sewerage line, electrical line, water main, any other government or public land, or public utility services;
(i) the required permission/No Objection Certificates of any other Departments/Agencies as required under law has not been obtained for any land developments and constructions.
(10) Vicinity of important buildings
No private building exceeding 10m height shall be permitted within 200m radius from the boundary of the Governor’s House, State Secretariat, Legislative Assembly, Official Residences of Chief Justice of High Court, Chief Minister, Heads of Legislature and such other buildings as may be notified by the ULB/Government from time to time.
(11) Water Bodies
(a) No building / development activity shall be allowed in the bed of water bodies like river or nala and in the Full Tank Level (FTL) of any lake, pond, cheruvu or kunta / shikam lands.
Unless and otherwise stated, the area and the Full Tank Level (FTL) of a Lake / Kunta shall be reckoned as measured and as certified by the Irrigation Department and Revenue Department.
(b) The above water bodies and courses shall be maintained as Recreational/Green Buffer Zone and no building activity shall be carried out within:
(i) 100m from the boundary of the River outside the limits of Local Authorities and 50m within the limits of the Local Authorities. The boundary of the river shall be as fixed and certified by the Irrigation Department and Revenue Department.
(ii) 30m from the FTL boundary of Lakes / Tanks / Kuntas of area 10Ha and above.
(iii) 9m from the FTL boundary of Lakes / Tanks / Kuntas of area less than 10Ha / shikam lands;
(iv) 9m from the defined boundary of Canal, Vagu, Nala, Storm Water Drain of width more than 10m.
(v) 2m from the defined boundary of Canal, Vagu, Nala, Storm Water Drain of width up to 10m.
(c)Unless and otherwise specified in the Master Plan/Zonal Development Plan.
(i) In case of (b) (i) & (ii) above, the buffer zone may be utilised for road of minimum 12m width, wherever feasible.
(ii) In case of (b) (ii) above, in addition to development of recreational / green belt along the foreshores, a ring road or promenade of minimum 12m may be developed, wherever feasible 3.6m walking / cycle track within the 30m buffer strip may be provided.
(iii) The above buffer zone to be left may be reckoned as part of tot lot or organized open space and not for setback requirements.
(d) In case of areas along the sea coast, the Coastal Regulation Zone Regulations shall be followed.
(12) Swimming Pool:
(a) Definition: A pool or a tank indoor or outside the building, used for the purpose of swimming, bathing, aquatic sports or games, training, treatment (Therapy) or recreation, meant exclusively for human being, having a depth of water not less than that 60cm and the surface area exceeding 23.25sq. m both for the use of public or the institution concerned.
(b) Swimming Pool may be permitted on ground or on the terrace of the building subject to submission of Structural Designs and Structural Stability Certificate issued by the Licensed Structural Engineer along with the Building Application. This shall not be constructed in the tot-lot or organized open space area meant for mandatory requirement for such purpose as per these rules.
(c) The applicant shall submit an Undertaking along with the Building Application that necessary safety measures are undertaken regarding construction and also the safety of the users.
(d) The following guidelines shall be followed:
(i) “Capacity of Pools in Relation to Bathers”: The maximum number of persons in bathing attire within the pool enclosures of the bathing area shall not exceed one person per 1.86sq. m (20sq. ft.) of pool i.e. the area of the water surface.
(ii) “Hand Rail”: A side handrail extending up above and returning to the horizontal surface of the pool deck curb or coping shall be provided at each side of each ladder.
(iii) “Depth Markers”: Depth of water shall be clearly marked at or above the water surface on the vertical pool wall and on the edge of the deck or walk-way next to the pool, at maximum points and at the points of break between the deep and shallow portions and at intermediate increments of depth, spaced at not more than 7.62cm (2’.5”) intervals. Depth markers, contrasting with background shall be on both sides of the pool.
(iv) “Lighting and Wiring”: Where submarine lightning is used, not less than 0.5 watts shall be employed per sq. ft. of pool area.
(v) “Area Lightning”: Where submarine lightning is employed, area lightning shall be provided for the deck areas and directed towards the deck areas and away from the pool surface so far as practicable, in a total capacity of not less than 0.6 watt per sq. ft of deck area. Where submarine lighting is not provided and night swimming is not permitted combined pool lightning shall be provided in an amount of not less than 2 watts per sq. ft. of total area. All submarine lightning shall be individually earthed and must be water tight and damp proof.
(vi) “Over Head Wiring”: No electrical wiring for electrical or power shall be permitted to pass over within 6m (20feet) of the pool enclosure.
(vii) “Shallow Minimum Depth”: Every swimming pool shall have a minimum depth in the shallow area of the main swimming area of not less than 0.9m (3feet), but not more than 1.07m (3'-6”) from the overflow level to the floor.
(viii)“Shallow Areas”: In a swimming pool with a diving area, the shallow area of the pool shall be defined as the portion between the shallow end and the break point between the shallow area and the diving area. The slope of the floor shall be uniform from the break point between the diving area and the shallow portion to the outside edge of the shallow portion and shall not be greater than 1 in 2m.
(ix) “Vertical Wall Depth”: The pool walls shall be vertical at all points for a depth of not less than 0. 76m (2’. 6".)