25.0 Structural Design
25.1 The structural design of foundations, elements made of masonry, timber, plain concrete; reinforced concrete, pre-stressed concrete and structural steel shall be carried out in accordance with Part 6. Structural design Section 1-Loads, courses and effects, Section 2-Soils and Foundation, Section-3- Timber and Bamboo, Section 4-Masonry, Section5-Concrete, Section 6-Steel, Section-7- Prefabrication, systems building and mixed / composite construction of National Building Code of India, amended from time to time. Proposed construction shall be as per the norms as specified by Indian Standard Institute, for the resistance of earthquake, Fire Safety and natural calamities. Certificate to that effect shall be submitted by the Licensed Structural Engineer of the developer / land owner, along with the proposal for development permission.
26.0 Quality of Materials and Workmanship
26.1 All materials and workmanship shall be of good quality conforming generally to accepted standards of Public Works Department of Maharashtra and Indian Standard Specifications and Codes as included in Part 5 - Building Materials and Part 7 - Construction Practices and Safety of National Building Code of India, amended from time to time
26.2 All borrow pits dug in the course of construction and repair of buildings, roads, embankments etc. shall be deep and connected with each other in the formation of a drain directed towards the lowest level and properly stopped for discharge into a river stream, channel or drain and no person shall create any isolated borrow pit which is likely to cause accumulation of water which may breed mosquitoes.
27.0 Alternative Materials, Methods of Design & Construction and Tests
27.1 The provision of the regulations are not intended to prevent the use of any material or method of design or construction, not specifically prescribed by the regulations, provided any such alternative has been approved.
27.1.1 The provision of these regulations is also not intended to prevent the adoption for architectural planning and layout conceived as an integrated development scheme.
27.2 The authority may approve any such alternative provided it is found that the proposed alternative is satisfactory and conform to the provisions of relevant parts regarding material, design, and construction and that material, method or work offered is, for the purpose intended, at least equivalent to that prescribed in the rules in quality, strength, compatibility, effectiveness, fire rating and resistance, durability and safety.
27.3 Tests: Whenever there is insufficient evidence of compliance with the provisions of the regulations of evidence that any material or method of design or construction does not conform to the requirements of the rules or in order to substantiate claims for alternative materials, design or methods of construction, the Municipal Commissioner may require tests sufficient in advance as proof of compliance. These tests shall be made by an approved agency at the expense of the owner
27.3.1 Test method shall be as specified by the regulations for the materials or design or construction in question. If there are no appropriate test methods specified in the regulations, the Authority shall determine the test procedure. For methods of tests for building materials; reference may be made to relevant Indian standards as given the National Building Code of India, published by the Bureau of Indian Standards. The latest version of the National building Code of India shall be taken into account at the time of enforcement of these rules.
27.3.2 Copies of the results of all such tests shall be retained by the authority for a period of not less than two year after the acceptance of the alternative material.
28.0 Building Services
28.1 The planning, design and installation of electrical installations, air-conditioning and heating work shall be carried out in accordance with Part 8 - Building Services, Section 2-Electrical and allied Installations, Section 3-Air Conditioning, heating and mechanical ventilation of National building Code of India, amended from time to time.
28.2 The planning design including the number of lifts, type of lifts, capacity of lifts depending on occupancy of building; population on each floor based on occupant load, height of building shall be in accordance with Section-5 installation of Lifts and Escalators of National Building Code of India, amended from time to time. In existing buildings, in case of proposal for one additional floor, existing lift may not be raised to the additional floor.
28.2.1 The lifts shall be maintained in working order properly.
29.0 Water Supply, Drainage and Sanitary Requirements.
29.1 The planning, design, construction and installation of water supply, drainage and sanitation and gas supply systems shall be in accordance with the provisions of Part 9 - Plumbing Services- Section 1 Water Supply, Drainage and Sanitation, Section 2 - Gas supply of National Building Code of India as amended from time to time.
29.2 Requirements of water supply in building.
The total requirements of water supply shall be calculated based on the population as given below:
| Occupancy | Basis |
|---|---|
| Residential Building | 5 persons per tenement |
| Other Buildings | No. of persons on occupant load and area of floors given in Table No.10. |
29.2.1 The requirements of water supply for various occupancies shall be as given in Table No.24 and Table No.25 or as specified by the Municipal Commissioner from time to time.
| Table No.24 | ||
| PER CAPITA WATER REQUIREMENTS FOR VARIOUS OCCUPANCIES/USES | ||
| Sr. No | Type of Occupancy | Consumption per head per day (in liters) |
| 1 | Residential | |
| (a) in living units | 135 | |
| (b) Hotels with lodging accommodation (per bed) | 180 | |
| 2 | Educational: | |
| (a) Day Schools | 45 | |
| (b) Boarding Schools | 135 | |
| 3 | Institutional (Medical Hospitals): | |
| (a) No. of beds not exceeding 100 | 340 | |
| (b) No. of beds exceeding 100 | 450 | |
| (c) Medical quarters and hostels | 135 | |
| 4 | Assembly-Cinema theatres, auditorium etc. (per seat of accommodation). | 15 |
| 5 | Government and Semi-public business. | 45 |
| 6 | Mercantile (Commercial) | |
| (a) Restaurants (per seat) | 70 | |
| (b) Other business buildings. | 45 | |
| 7 | Industrial | |
| (a) Factories where bathrooms are to be provided | 45 | |
30.0 Drainage and Sanitation Requirements
30.1 General
There should be at least one water tap and arrangement for drainage in the vicinity of each watercloset or group of water-closets in all the buildings.
30.1.1 Each family dwelling unit on premises (abutting on a sewer or with a private sewage disposal system) shall have, at least, one water-closet and one kitchen type sink. A bath or shower shall also be installed to meet the basic requirement of sanitation and personal hygiene.
30.1.2 All other structures for human occupancy or use on premises, abutting on a sewer or with a private sewage disposal system, shall have adequate sanitary facilities, but in no case less than one watercloset and one other fixture for cleaning purposes.
30.2 For Residences
30.2.1 Dwelling with individual convenience shall have at least the following fitments:
a) One bathroom provided with a tap and a floor trap,
b) One water-closet with flushing apparatus with an ablution tap; and
c) One tap with a floor trap or a sink in kitchen or wash place.
30.2.2 Dwelling without individual conveniences shall have the following fitments:
a) One water tap with floor trap in each tenement,
b) One water-closet with flushing apparatus and one ablution tap, bath for every two tenements, and
c) One bath with water tap and floor trap for every two tenements.
30.3 For Buildings Other than Residences
30.3.1 The requirements for fitments for drainage and sanitation in the case of buildings other than residences shall be in accordance with Tables given in Appendix-O (1 to 14). The following shall
be, in addition, taken into consideration:
a) The figures shown are based upon one (1) fixture being the minimum required for the number of persons indicated or part thereof.
b) Building categories not included in the tables shall be considered separately by the Municipal Commissioner.
c) Drinking fountains shall not be installed in the toilets.
d) Where there is the danger of exposure to skin contamination with poisonous, infectious or irritating material, washbasin with eye wash jet and an emergency shower located in an area accessible at all times with the passage / right of way suitable for access to a wheel chair, shall be provided.
e) When applying the provision of these tables for providing the number of fixtures, consideration shall be given to the accessibility of the fixtures. Using purely numerical basis may not result in an installation suited to the need of a specific building. For example, schools should be provided with toilet facilities on each floor. Similarly toilet facilities shall be provided for temporary workmen employed in any establishment according to the needs; and in any case one WC and one washbasin shall be provided.
f) All buildings used for human habitation for dwelling work, occupation, medical care or any purpose detailed in the various tables, abutting a public sewer or a private sewage disposal system, shall be provided with minimum sanitary facilities as per the schedule in the tables. In case the disposal facilities are not available, they shall be provided as a part of the building design for ensuring high standards of sanitary conditions in accordance with this section.
g) Workplaces where crèches are provided, they shall be provided with one WC for 10 persons or part thereof, one washbasin for 15 persons or part thereof, one kitchen sink with floor tap for preparing food / milk preparations. The sink provided shall be with a drinking water tap.
h) In all types of buildings, individual toilets and pantry should be provided for executives and for meeting / seminar / conference rooms, etc. as per the user requirement.
i) Where food is consumed indoors, water stations may be provided in place of drinking water fountains.
31.0 Signs and Outdoor Display Structures
31.1 The display of advertising signs on buildings and land, shall be in accordance with Part 10, Section-2 "Signs and outdoor display structures" of National Building Code of India as amended from time to time and, shall be in accordance with respective rules/by-laws, directive given by Government, and also rules/by-laws framed by the corporation in this regards from time to time.
Prohibition of advertising signs and outdoor display structure in certain cases Notwithstanding the provisions of sub-regulations no advertising sign or outdoor display structures shall be permitted on buildings of architectural, aesthetical, historical or heritage importance as may be decided by the Commissioner or on Government Buildings save that in the case of Government buildings only advertising signs or outdoor display structure may be permitted if they relate to the activities for the said buildings‘ own purposes or related programmers.