Part IVGeneral Building Requriements – Setback, Marginal Distance, Height and Permissible FSI
17.0 General
Following regulations for congested area shall be applicable for the lands included in congested area as shown on the plan. For the areas outside congested area in the development plan regulation for outside-congested area shall apply.
However, in congested area, if the original land holding is more than 0.40 Hectare, then regulations of non-congested area, except FSI, shall apply. FSI in such cases shall be as per the Regulation No.17.1.1
17.1Regulations for Congested Area
17.1.1 Residential Buildings/ Residential Buildings with mix-use
(a) Floor Space Index: - The maximum permissible basic floor space index , permissible TDR loading and additional FSI on payment of premium shall be as per the following table. There is no priority fix to allow additional FSI or TDR.
Table No.5
Sr.no.
Road width in meter
Basic FSI
Additional FSI on payment of premium
Maximum permissible TDR loading
Maximum building potential on plot
1
2
3
4
5
6
1
Below 9.0 m.
1.50
--
--
1.50
2
9.00 m. and upto 12.00 m.
2.00
--
--
2.00
3
12.00 m. and upto 18.00 m.
2.00
0.25
--
2.25
4
18.00 m. and upto 24.00 m.
2.00
0.25
0.25
2.50
5
24.00 m. and upto 30.00 m.
2.00
0.25
0.50
2.75
6
30.00 m. and above
2.00
0.25
0.75
3.00
(b) Front Marginal distances- The minimum front setback from the existing or proposed road/roads shall be as under.
Sr. No.
Road width
For Residential building
For Residential Buildings with mix-use
(i)
For streets/lane less than 4.5 m. width
2.25m. from the centre of the street/ lane
2.25m. +1.50 mt. from the centre of the street/lane
(ii)
For streets 4.5m. to less than 6.00 m. in width
NIL
1.50 m.
(iii)
For streets 6.00 m. to less than 12 m. in width
1.50 m.
2.00 m.
(iv)
For streets 12 m to less than 18 m. in width
1.50 m
2.25 m.
(v)
For streets 18 m & above in width
1.50 m
2.25 m.
(c) For the lanes having width less than 4.5m. abutting to any side of plot, a setback of 2.25m. from the centre of lane shall be provided to make such lane 4.5m. wide. No any projections shall be permissible on such widened lane width.
(d) All other regulations excepting FSI and its maximum loading limit, marginal distances as prescribed above, shall be applicable for development permission in congested area.
(e) In R-2 zone, for buildings having shops /commercial user on any floor, 50% of front marginal distance shall be made available exclusively for the pedestrians.
(f) Height- Above set back and marginal distances shall be applicable for buildings less than 15 m. in height. Marginal distances shall be increased by 1m. for buildings having height 15 m. and more but less than 24 m. For building having height 24 m. and more, marginal distances shall be as per regulations of non-congested area.
17.1.2 Other buildings like Public semi-public, Educational, Medical, Institutional, commercial, Mercantile, etc.
(a) Floor Space Index – Maximum FSI permissible shall be as per the table under regulation no.17.1.1 and subject to payment of premium as decided by Government from time to time.
(b) Marginal Distance - For these buildings marginal distances shall be 3 m. on all sides including front margin.
(c) For buildings having height more than 24 m., regulations of outside congested area shall apply for front, side and rear marginal distances.
Provided also that, for buildings like cinema theatre, multiplex, assembly buildings, shopping malls, regulation of outside congested area, except FSI, shall apply.