One or more basements may be permissible for following uses and shall be constructed after leaving the prescribed set-back / required front open space / required front margin, and prescribed building lines
a) storage of household or other goods or ordinarily non-combustible material;
b) strong rooms, bank lockers, safe deposit volts, radio/laser therapy unit, mortuary and medical allied uses, etc.
c) air-conditioning equipments and other machines used for services and utilities of the building;
d) parking spaces;
e) D.G. set room, meter room and Electric substation (which will conform to required safety requirements);
f) Effluent Treatment Plant, suction tank, pump room;
g) users strictly ancillary to the Principal user.
Provided that the users mentioned at (a) & (b) above shall be permitted only by counting in F.S.I. subject to the following conditions:
i) All requirements regarding access, safety (including fire safety), ventilations, etc. shall be complied with.
ii) All the planning standards (particularly as regarding parking) should be strictly adhered to. The basement shall not be used for residential purpose.
iii) Users other than (a) and (b) shall not be counted in FSI.
Provided that,
i) If the basement is proposed flushing to average surrounding ground level, then such basement can be extended in side and rear margins upto 3 mt. from the plot boundary. If the basement is proposed to be constructed below podium then marginal distances shall be as that of podium.
ii) Multilevel basements may be permitted if the basement is used for parking. The ramps of minimum3.0 m. width for entry and exit of vehicles separately shall be provided. In case of bonafide hardship, the Municipal Commissioner may allow only one ramp with not less than 6.0 m. in width.
The basement shall have the following requirements -
(i) Every basement shall be in every part at least 2.4 mt. in height from the floor to the underside of the roof slab or ceiling soffit of beam.
(ii) Adequate ventilation shall be provided for the basement with a ventilation area not less than 2.5% of the area of the basement. The standard of ventilation shall be the same as required by the particular occupancy according to these regulations. Any deficiency may be met by providing additional adequate mechanical ventilation in the form of blowers, exhaust fans, air conditioning systems etc.