24.0 General
Additional/higher Floor space index may be allowed in certain categories in non-congested area, except as otherwise specified and subject to following conditions:
a) Permissible additional FSI for the buildings as mention in Table no 20 shall be the maximum permissible building potential according to road width as mention in column 6 of Table no.5 or 8of Regulation no 17.1.1 or 17.3 (wherever applicable) minus Basic FSI. No restriction to avail the additional FSI in the form of FSI only.
b) Such additional FSI shall be available for use for which additional FSI is granted only and other permissible uses shall be allowed within the basic Permissible FSI.
c) Premium –Premium for additional F.S.I. shall be per column 4 of the table. Rate of the premium is based on the land rate mentioned in ASR for respective S.No./CTS No. The premium collected shall be shared 50:50 between State Government & Corporation respectively. Premium to be paid to the Government shall be deposited in the concerned Account Head of Urban Development Department at Government Treasury by the Planning Authority. The following quantum of premium shall be subject to the orders of the Government from time to time.
d) The additional FSI shall also be permissible to existing authorised users subject to structural stability.
e) The other conditions as mentioned in the Government Directives issued under section 154 of the M.R.&T.P.Act 1966 vide Resolution no TPS-1815/2647/CR-13/15/UD 13/Dared 14/03/2016 shall also be applicable.
f) If the owner / developer desire to avail such additional FSI in future for new buildings , then while seeking building permission at first instance, the building plan shall be submitted considering the Marginal distances as required for the height of buildings for such additional FSI. No condonation in the required open spaces, parking and other requirements in these regulations shall be allowed. However for the existing building proposals, such condition need not be insisted. But proposal shall be cleared only after strictly confirming structural and fire safety norms.
g) Exit Requirements, Requirements of Water Supply, Drainage and Sanitation Parking spaces requirements, Fire provision requirements shall conform the provisions as mentioned in these regulations
h) No Amenity Spaces shall required to be provided for the uses mention in Table No.20, except at sr.no.(I)
| Table No. 2024.1 - Permissible Marginal spaces, permissible basic FSI, Additional FSI for buildings in non-congested area | ||||
| Categories of the otherbuildings | Basic FSI | additional FSI | Rate of thePremium | Conditions if any, |
| 1 | 2 | 3 | 4 | 5 |
| A)Educationali) Pre-primary School,nursery Kinder gardenand Special EducationalInstitute for Physicallyhandicapped/Mentallyill. | As perRegulationNo.17.1.1 or17.3,whereverrequired | Maximum BuildingPotential limit as perroad width asmention in column 4of Table No. 5 or8(wherever required)minus basic FSI | 10 % | Educational building excepting buildings for Pre-primary School,nursery Kinder garden and Special Educational Institute forPhysically handicapped/Mentally ill.a) if the total area of the plot is not less than 0.4 hect. except landsreserved in development plan, and for the redevelopment of existingMunicipal Schools,b) area as mentioned below is available for playground. |
| ii) Primary School | As perRegulationNo.17.1.1 or17.3 whereverrequired | Maximum BuildingPotential limit as perroad width asmention in column 4of Table No. 5 or8(wherever required)minus basic FSI | 20 % | |
| Area of Play Ground | ||||
| 40% | ||||
| For first 5 hect. 40% and for remaining20% | ||||
| Provided that, it shall not be necessary to increase area of existingplayground; if any, when utilisation of additional FSI as otherwisepermissible in these regulations, is proposed on upper floor ofexisting building.Provided further that, in case of existing building whereinutilisation of additional FSI is proposed, area of playground shall notbe less than 40% or the existing area of playground whichever isminimum.Provided further that, in case of existing building whereinutilisation of additional FSI on upper floors is not possible and it is | ||||
| iii) Other EducationalBuildings includingboys/girls youthhostels within 500 m.periphery fromtherecognised educationalinstitutions. | As perRegulationNo.17.1.1 or17.3 whereverrequired | Maximum BuildingPotential limit as perroad width asmention in column 4of Table No. 5 or8(wherever required)minus basic FSI | 30 % | |
| necessary to expand the existing building to accommodate number ofstudents, then in such exceptional circumstances, area of play groundmay be permitted to be reduced, with the prior permission ofGovernment.Other Conditions-i) The Educational Institute shall be of Government/SemiGovernment public authorities, Charitable Institutions or PrivateInstitutionsii) Educational buildings shall not be permissible within 60 m. fromthe existing assembly building and 90 m. from the existing petrolpump.iii) Educational building shall only be permitted if 40% area isavailable for playground. However, this provision shall not beapplicable to already approved existing building whereinconstruction of additional floor is proposed.iv) No classroom shall admeasure less than 38 sq. m. with aminimum dimension of 5.50 m. The height of any classroom shallnot be less than 3.60 m.v) While granting Additional FSI to Educational Institutions offeringprimary and secondary education 5 % seats shall be reserved foradmission for Government nominees. Deputy Director, EducationDepartment shall be competent to decide such nominations.However, this condition shall not be applicable for HigherEducation, Technical Education and Medical Education.vi) As and when required, some rooms of Educational Buildings shallbe made available to the Government by the concernedinstitutions.vii)The Educational Institution shall maintain records regarding free /concessional education rendered to the needy persons, which shall | |||||||
| ions. | |||||||
| be made available to the Director of School Education, Higher and Technical Education on demand. viii) The Director of School Education, Government of Maharashtra shall be the competent authority to monitor as to whether the Educational Institution is observing the terms and conditions referred to at (i) ,(ii)and (iii) above and, in case of any breach thereof or in case the Education being rendered by the Educational Institution are not to the satisfaction of the said Department, the Director of School Education shall have the right to suitably penalise the Education Institution. ix) The Educational Institution shall file an undertaking that it shall abide by the above enumerated terms and conditions. x) Adequate Parking facilities as required per prevailing Development Control Regulation shall be provided. xi) While granting occupation certificate the Municipal Commissioner shall intimate to the Director of school Education for compliance of afore said condition along with copy of occupation certificate and plan. xii)Maximum of height of Educational building shall be as per The Maharashtra Fire protection and Life Safety Measure, Act, 2006 xiii) Hostels shall not be misused and converted into other use. If it is found that the hostels are used for other purpose, Municipal Commissioner Authorised to take action as per the law. | ||||
|---|---|---|---|---|
| B)Medical Institutions-Hospital, Maternity Homes, Health Club, buildings | As per Regulation No.17.1.1 or 17.3,whereverrequired | Maximum Building Potential limit as per road width as mention in column 4 of Table No. 5 or 8(wherever required) minus basic FSI | i)No premium for Government, Semi Government, public authorities | i) The Medical Institutions of Government, Semi Government, public authorities, Charitable Institutions or private owner. ii) Free medical treatment to the extent of atleast 20% of the total number of beds shall be given to persons from Economically Weaker Sections of society or to persons below the poverty line. In addition, 10% of the total number of patients in OPD shall be |
| However building | maximum potential shall be consider as 4.00 for Government Hospitals and 3.00 for other hospitals subject to Roads width 18 mt and | ii) 30% Charitable Institutions iii) 40% for private hospitals | charged in government hospitals. The Medical Institution shall furnish the requisite periodical statements to the Director of Health Services in this regard. iii) The Medical Institution shall maintain records regarding free/concessional medical treatment rendered to the needy | |
| more. | persons, which shall be made available to the Director of Health Services on demand. vi) Any Special ward in the hospital building shall not admeasure less than 9.0. sq.m. in area with no side less than 3 m. v) Area of the general wards shall not admeasure less than 40 sq. m. |