(a) Front Margin - Front margin shall be as given below with reference to height of building
| i) | Height above 18 m. & upto 24 m. | 4.5 m and 6.00 m. for residential with mix use |
|---|---|---|
| ii) | Height above 24 m. & upto 36 m. | 6.0 m. |
| iii) | Height above 36 m. & upto 50 m. | 9.00 m. |
| iv) | Height above 50 m. & upto 70 m. | 12.00 m. |
| v) | Height above 70 m. & upto 100 m. | 14.00 m. |
| v) | Height above 100 m. | 16.00 m. |
Provided that, in case of group housing scheme where building abuts on internal road, the minimum 3.0 m. set back from internal road or distance between two buildings whichever is more shall be provided. For Development plan road or classified road or through road, passing through Group Housing Scheme, the setback as prescribed in the regulations shall be provided.
(b)Side or rear marginal distance - Side or rear marginal distance in relation to the height of the building for light and ventilation shall be as below
The marginal distance on all sides shall be as per Table No.6 for building height 15.0 m. and below. For height more than 15.0 m., the marginal distance on all sides except the front side of a building shall be minimum H/4 (Where H = Height of the building above ground level) subject to a minimum of 3.0 m. for residential building, 4.5 m. for commercial building and 6.0 m. for special building mentioned in definition no. 2.77.13.Provided that such marginal distance shall be subject to maximum of 16.0 m. If the land owner wishes to keep higher margins he may be allowed to do so.
Provided further that the building height for the purposes of this regulation and for calculating the marginal distances shall be exclusive of height of parking floors upto 6.0 m.
Provided also that, for building having shops / commercial user on any floor, 50% of front marginal distances shall be made available exclusively for pedestrians.
(c) Provision for Step Margin: - Step margins may be allowed to be provided on upper floor at height 24 m. and above to achieve required marginal distances as mentioned in these regulations subject to structural stability and fire protection norms as prescribed from time to time. If building height 24 m. and above minimum side margin at ground level shall be 7.5 m. and if building height 50 m. and above the minimum side margin shall be 9.00 m. In congested area minimum side margin at ground level shall be 6.00 m.
17.2.4 In case of layout of two or more buildings of any users:-
i) Distance between two buildings- The distance between two buildings shall be the side/rear marginal distance required for the taller building between the two adjoining buildings.
ii) Provided that, the path way / internal road may be allowed to be proposed in such marginal distance by keeping 3.0 m. distance on both side from such internal road.
Provided also that, where rooms do not derive light and ventilation from the exterior open space, the distance between the two buildings may be reduced by 1 m. subject to a minimum of 3 m. (if necessary 6.0 m. in case of special building) and maximum of 8.0 m. No projections shall be
permitted in this exterior space.
17.2.5 In case of group housing scheme where building abuts on internal road, the minimum 3.0 m. set back from internal road or distance between two buildings whichever is more shall be provided. For Development plan road or classified road or through road, passing through Group Housing Scheme, the setback as prescribed in the regulations shall be provided.
17.2.6 Buildings Abutting Two or More Streets
When a Building abuts two or more streets, the setbacks from the streets shall be such as if the building is fronting on each such street