No structure including veranda or balcony shall be allowed to be erected or re-erected or any additions or alterations made to a building on a site within the distance quoted in Table No.2 below in accordance with the prevailing Indian Electricity Rules and its amendments from time to time between the building and any overhead electric supply line.
| Table No.2 | ||
| Electric Lines | Vertically (m.) | Horizontally (m.) |
| (1) | (2) | (3) |
| (a) Low and medium voltage Lines and Service Lines. | 2.5 | 1.2 |
| (b) High voltage lines upto 11,000 V. | 3.7 | 1.2 |
| (c) High voltage lines above 11,000 V and upto 33,000 V. | 3.7 | 2.0 |
| (d) Extra High voltage line beyond 33,000 V. | 3.7(Plus 0.3 m. for every additional 33,000 V. or part thereof) | 2.0(Plus 0.3 m. for every additional 33,000 V. or part thereof) |
| Note :The minimum clearance specified above shall be measured from maximum sag for vertical clearance and from maximum deflection due to wind pressure for horizontal clearance. | ||
No piece of land shall be used as a site for the construction of building
(a) If the Authority considers that the site is insanitary, incapable of being well drained or it is dangerous to construct a building on it;
(b) If the entire site is within a distance of 6 m. from the edge of water mark of a minor water course and 15 m. from the edge of water mark of a major water course shown on Development Plan or village/city survey map or otherwise,
Provided that where a minor water course passes through a low lying land without any well-defined banks, the owner of the property may be permitted by the Municipal Commissioner to restrict and or to realign the same within the same land according to cross section available with the Corporation, modified from time to time without changing the position of the inlet and outlet of the water course. In such case marginal open spaces shall be as required under these regulations subject to minimum 4.50 m. from the edge of the trained nala.
Notwithstanding anything contained hereinabove, the Municipal Commissioner shall be entitled to take cognizance of the existence of all water courses whether shown on the Development Plan or not, while sanctioning layouts and no person shall take any action without the permission of the Commissioner which results in reducing the water way or closing or filling up of any existing water course. If any watercourse, whether shown in the Development Plan/Revenue Record or not, but existing on the site/land, owned by private person, the area under such water course shall not be deducted for computation of FSI.
(c) If the owner of the plot has not shown to the satisfaction of the Authority all the measures required to safeguard the construction from constantly getting damped;
(d) If the use of the site is for the purpose, which will be a source of annoyance to the health and comfort of the inhabitants of the neighbourhood;
(e) If the proposed use of land or occupancy of the building on the site does not conform to the land use proposals in the development plans or Zoning Regulations,
(f) If the level of the site is less than prescribed datum level depending on topography and drainage aspects;
(g) If it doesn‘t derive access from an authorised street/means of access described in these Regulations;
(h) If the land is within a prohibited distance (currently of seventy five meters) from the crest of the outer parapet of the Armament Research and Development Establishment (ARDE), Range Pashan, Pune;
(i) If the land is within a prohibited distance of approximately 457.2 m (500 yards) from the crest of the outer parapet of the High Energy Materials Research Laboratory (HEMRL), Sutarwadi, Pune as shown on Development Plan;
(j) If the site is hilly and having gradient more than 1:5whether shown on the Development Plan or not;
(k) If the site is not developable / buildable by virtue of restrictions imposed under any law or guidelines of any Government department.
(l) If the plot has not been approved as a building site by Authority.