18.4.1 Size of bathroom and water closet -
i) The size of a bathroom shall be not less than 1.8 sq.m. with a minimum width 1.2 m. The size of a water closet shall be not less than 1.10 sq.m with a minimum width of 0.9m. The minimum area of a combined bathroom and water-closet shall be 2.8 sq.m. with a minimum width of 1.2 m. ii)In the case of EWS/LIG housing scheme the sizes of bathroom and water-closets shall be as follows:-
a) The size of independent water-closet shall be at least 0.90sq.m. with minimum width of 0.9m.
b) The size of independent bathroom shall be at least 1.20sq.m. with a minimum width of 1.00m
c) The size of combined bathroom & water-closet shall be atleast 1.80sq.m. with minimum width of 1.0m.
18.4.2 Height:- The Height of a bathroom or water closet measured from the surface of the floor to the lowest point in the ceiling (bottom of slab) shall be not less than 2.1 m.
18.4.3 Other Requirements - Every bathroom or water closet shall -
i. be so situated that at least one of its walls shall open to external air,
ii. not be directly over or under any room other than another water-closet, washing place, bath or terrace, unless it has a water-tight floor,
iii. have platform or seat made of water-tight non-absorbent material;
iv. be enclosed by walls or partitions and the surface of every such wall or partition shall be finished with a smooth impervious material to a height of not less than 1 m. above the floor of such a room.
v. every water closet and/or a set of urinals shall have a flushing cistern of adequate capacity attached to it. In EWS/LIG housing, however, no such flushing cistern need be provided,
vi. be provided with an impervious floor covering sloping towards the drain with a suitable grade and not towards veranda or any other room,
vii. in High Density housing, pour flush water seal latrines (NEERI type) may be permitted when the sewerage system is not available and the water table in the area is not high.
viii. all the sewerage outlets shall be connected to the sewerage system. Where no such systems exist a septic tank shall be provided within the plot conforming to the requirements of Regulation No.41.30.
ix. have a window or ventilator, opening to a shaft or open space, of area not less than 0.3sq.m. with side not less than 0.3m.
18.4.4 Restriction on use of room containing water closet.
No room containing water closets shall be used for any purpose except as a lavatory and no such room shall open directly into any kitchen or cooking space by a door, window or other opening. Every room containing water closet shall have a door completely closing the entrance to it.