Modern buildings consume about 25 to 30 % of total energy, and up to 30 % of fresh potable water, and generate approximately 40 % of total waste. Sustainable buildings have demonstrated reduction in energy and water consumption to less than half of the present consumption in conventional buildings, and complete elimination of the construction and operational waste through recycling.
Thus, all buildings on various plot sizes above 100 sq.m. shall comply with the green norms and conform to the requirements mandatory for sanction as mentioned in this chapter.
These provisions are not specific to any rating system and are not intended to provide a single metric indication of overall building performance. These provisions allows the practitioners to easily exercise their engineering judgment in holistically and objectively applying the underlying principles of sustainability to a development or building facility, considering its functionality and required comfort level.
10.1 Provisions and Applicability
The green building provisions on various plot sizes are indicated in the table below:
| Plot Category | Applicable plot area (sq.m) | Provisions for Residential | Provisions for Non- Residential |
| I | Up to 100 | Nil | Nil |
| II | 100 to 500 | 1(a), 2(a), 2(b), 4(a) | 1(a), 2(b), 4(a) |
| 500 to 1,000 | 1(a), 1(c), 2(b), 3(c), 4(a) | 1(a), 1(c), 2(a), 2(b), 3(c), 4(a) | |
| 1,000 to 3,000 | 1(a), 1(c), 1(d), 2(a), 2(b), 3(b), 3(c), 4(a) | 1(a), 1(c), 1(d), 2(a), 2(b), 3(b), 3(c), 4(a) | |
| III | Above 3,000 | 1(a), 1(b), 1(c), 1(d), 2(a), 2(b), 3(a), 3(b), 3(c), 4(a), 4(b) | 1(a), 1(b), 1(c), 1(d), 2(a), 2(b), 3(a), 3(b), 3(c), 4(a), 4(b) |
*Note: provisions marked 1(a), 2(b) etc are as per section 10.2.
The schemes/ projects formulated on the basis of provisions given in Master plan/ Zonal Development Plan will require approval as indicated:
EIA/ ECC (as per MoEF), NBC (latest), ECBC 2007 or latest, BEE Star rating/ LEED of IGBC/ GRIHA of TERI Certification}
EIA- Environmental Impact Assessment Study Report,
ECC- Environmental Clearance Certificate,
MoEF – Ministry of Environment and Forest,
NBC – National Building Code,
ECBC – Energy Conservation Building Code,
BEE – Bureau of Energy Efficiency,
LEED – Leadership in Energy and Environment Design,
IGBC –Indian Green Building Council,
GRIHA – Green Rating for Integrated Habitat Assessment,
TERI – The Energy and Resources Institute.
The prevailing provisions of the above shall be applicable. However if there are any modification in the same, the modified provisions shall become automatically applicable.
Green Buildings and Sustainability Provisions
10.2 Provisions for Sanction
- Water Conservation and Management
a) Rain Water Harvesting
b) Low Water Consumption Plumbing Fixtures
c) Waste Water Recycle and Reuse
d) Reduction of Hardscape
- Solar Energy Utilization
a) Installation of Solar Photovoltaic Panels (detailed at section 10.2.3 below)
b) Installation of Solar Assisted Water Heating Systems
- Energy Efficiency (Concept of passive solar design of buildings) (Ref. Table 14.1-3)
a) Low Energy Consumption Lighting Fixtures (Electrical Appliances – BEE Star and Energy Efficient Appliances)
b) Energy Efficiency in HVAC systems.
c) Lighting of Common areas by Solar energy/ LED devices.
- Waste Management
a) Segregation of Waste
b) Organic Waste Management
In case owners of properties desire to procure green building ratings from one or more rating bodies, they may suitably incorporate any other provisions if required and additional incentive FAR as per Master Plan may be availed.
10.2.1 Provisions for City and Site level greening
In alignment with National Sustainable Habitat Mission, the Authority shall encourage augmentation of green cover in the city/plot, by following:
The Urban Greening Guidelines, 2014 and other provisions as given below -
i. Provision of minimum 1 tree / every 80sqmt of plot area for plot sizes > 100sqmt and planted within the setback of the plot.
ii. Compensatory Plantation for felled/transplanted tress in the ratio 1:3 within the premises under consideration.
iii. Choice of species for plantation in site and abutting the road to be adopted as per Section 8 of the Urban Green Guidelines, 2014.
iv. The unpaved area shall be more than or equal to 20% of the recreational open spaces.
10.2.2 Water Re-use and Recycling
All building having a minimum discharge of 10,000 l. and above per day shall incorporate waste water recycling system. The recycled water should be used for horticultural purposes.
10.2.3 Roof Top Solar Energy Installations
Rooftop photovoltaic power station, or rooftop PV system, is a photovoltaic system that has its electricity-generating solar panels mounted on the rooftop of residential or commercial buildings. The various components of such a system include photovoltaic modules, mounting systems, cables, solar inverters and other
Green Buildings and Sustainability Provisions
electrical accessories. Rooftop PV systems are faster than other types of renewable power plants. They’re clean, quiet, and visually unobtrusive. Table 10.2 below stipulates the Norms for Roof Top Solar PV Installation-
10.3 Various Guidelines for Green Rating systems
The respective State Governments may prepare their separate Green Rating systems for buildings by selectively combining/adopting/amending the provisions between the following guidelines:
-
IGBC guidelines by the Confederation of Indian Industries.
-
GRIHA guidelines by the Ministry of New and Renewable Energy. GoI.
In pursuance of the National Sustainable Habitat Mission on Energy Efficiency in Buildings, the Authority shall encourage the provisions of the following Energy efficiency guidelines by certain mandatory provisions and incentives-
-
ECBC guidelines prepared by Bureau of Energy Efficiency, Ministry of Power. GoI
-
Model Energy Efficiency guidelines. (NSMH Sub report by Bureau of Energy Efficiency)