4.1 General
This part sets out the standard space requirements of various parts of a building (for all types of buildings – low/ high rise).
| Sl.No. | Type of Occupancy | Occupant Load per 100 sq m. of Plinth or Covered Area |
|---|---|---|
| 1 | Residential | 8.0 |
| 2 | Educational | 25.0 |
| 3 | Institutional | 6.60 |
| 4 | Assembly with fixed or loose seats and dance floor without seating facilities including dining rooms | 166.666.6 |
| 5 | Mercantile street floor and sales basement upper sale floor | 33.316.6 |
| 6 | Business and industrial | 10.0 |
| 7 | Storage | 3.3 |
| 8 | Hazardous | 10.0 |
* The occupant load in dormitory portions of homes for the aged, orphanages or mental hospitals etc. where sleeping accommodation is provided shall be calculated at not less than 13.3 persons per 100 sq.m.
** The plinth or covered area shall include, in addition to the main assembly room or space, any occupied connecting room or space in the same storey or in the storeys above or below where entrance is common to such rooms and space and the area available for use by the occupants of the assembly place. No deduction shall be made in the plinth/covered area for corridors, closets and other sub-divisions; that area shall include all space serving the particular assembly occupancy.
4.2 Requirements for Parts of Buildings
4.2.1 Plinth
4.2.1.1 Main Buildings
The plinth or any part of a building or outhouse shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth shall be not less than 450 mm from the surrounding ground level.
4.2.1.2 Interior Courtyards and Covered Parking
Every interior courtyard shall be raised at least 150 mm above the determining ground level and shall be satisfactorily drained.