i) Is structurally unsafe, or
ii) Is insanitary, or
iii) Is not provided with adequate means of ingress or egress or
iv) Constitutes a fire hazard or
v) Is dangerous to human life or
vi) In relation to its existing use, constitutes a hazard to safety or health or public welfare by maintenance, dilapidation or abandonment.
Note: All unsafe buildings /structure will require to be restored by repairs, demolition or dealt with as directed by the Authority. The relevant provisions of the Act shall apply for procedure to be followed by the Authority in taking action against such buildings.
17. “Building Height”- The vertical distance measured
i) In the case of flat roofs from the average level of the front road and continuance to the highest point of the building.
ii) In case of pitched roofs upto the point where the external surface of the outer wall intersects the finished surface of the sloping roof and
iii) In the case of gables facing the road midpoint between the eaves level and the ridge.
Architectural features serving no other function except that of decoration shall be excluded for the purpose of measuring heights. The height of the building shall be taken upto the terrace level for the purpose of fire safety requirement.
-
“Building Envelope” - The horizontal spatial limits up to which a building may be permitted to be constructed on a plot.
-
“Building Line”- The line upto which the plinth of building adjoining a street or an extension of a street or on a future street may lawfully extend and includes the lines prescribed, if any, in any scheme and/or development plan. The building line may change from time-to-time as decided by the Authority.
-
“Cabin”- A non-residential enclosure constructed of non-load bearing partitions.
-
“Canopy”- shall mean a cantilevered projection from the face of the wall over an entry to the building at the lintel or slab level provided that:
i) It shall not project beyond the plot line.
Definitions
ii) It shall not be lower than 2.3 m. or 7’- 6” when measured from the ground.
iii) There shall be no structure on it and the top shall remain open to sky.
-
“Carpet Area” - The covered area of the usable rooms of a dwelling unit / at any floor (excluding the area of the walls).
-
“Chajja”- A sloping or horizontal structural overhang provided over openings on external walls for protection from the weather.
-
“Chimney”- A construction by means of which a flue is formed for the purpose of carrying products of combustion to the open air and includes a chimneystack and flue pipe.
-
"Construction" - Any erection of a structure or a building, including any addition or extension thereto either vertically or horizontally, but does not include, any reconstruction, repair and renovation of an existing structure or building, or, construction, maintenance and cleansing of drains and drainage works and of public latrines, urinals and similar conveniences, or, the construction and maintenance of works meant for providing supply of water for public, or, the construction or maintenance, extension, management for supply and distribution of electricity to the public; or provision for similar facilities for publicity.
-
“Conversion”- The change from one occupancy to other occupancy or any change in building structure or part thereof resulting in a change of space and use requiring additional occupancy certificate.
-
“Cornice”- means a sloping or horizontal structural overhang usually provided over openings or external walls to provide protection from sun and rain.
-
“Courtyard”- A space permanently open to sky, enclosed fully or partially by buildings and may be at ground level or any other level within or adjacent to a building.
-
“Covered Area”- The Ground area covered immediately above the plinth level covered by the building but does not include the space covered by:
a. Garden, rockery, well and well structures, plant nursery, water pool, swimming pool (if uncovered), platform round a tree, tank, fountain, bench, chabutra with open top and unenclosed on sides by walls and the like;
b. Drainage culvert, conduit, catch-pit, gully-pit, chamber, gutter and the like;
c. Compound wall, gate, slide/ swing door, canopy, and areas covered by chajja or similar projections and staircases which are uncovered and open at least on three sides and also open to sky.
“Damp Proof Course”- A course consisting of some appropriate water proofing material provided to prevent penetration of dampness or moisture.
- “Density”- The residential density expressed in terms of the number of dwelling units per hectare.
Note: Where such densities are expressed exclusive of community facilities and provision of open spaces and major roads (excluding incidental open spaces), these will be net residential densities. Where these densities are expressed taking into consideration the required open space provision and community facilities and major roads, these would be gross residential densities at neighbourhood level, sector level or town level, as the case may be. The provision of open spaces and community facilities will depend on the size of the residential community. Incidental open spaces are mainly open spaces required to be left around and in between two buildings to provide lighting and ventilation.
Definitions
-
“Development” - ‘Development’ with grammatical variations means the carrying out of building, engineering, mining or other operations, in, or over, or under land or water, on the making of any material change, in any building or land, or in the use of any building, land, and includes re-development and layout and subdivision of any land and ‘to develop’ shall be construed accordingly.
-
“Development Plan”- See “Master Plan”
-
“Drain”- A conduit or channel for the carriage of storm water, sewage, waste water or other waterborne wastes in a building drainage system.
-
“Drainage system” - A system or a line of pipes, with their fittings and accessories, such as manholes, inspection chambers, traps, gullies, floor traps used for drainage of building or yards appurtenant to the buildings within the same cartilage; and includes an open channel for conveying surface water or a system for the removal of any waste water.
-
“Dwelling”- A building or a portion thereof which is designed or used wholly or principally for residential purposes for one family.
-
“Empanelled Architect”- A person empanelled by the Authority as per rules under the bye-laws as an authorized person to sanction building plans of residential buildings upto 15 m. in height and for plot sizes upto 500 sqm, forming part of any approved lay-out plan.
-
“Encroachment”- means an act to enter into the possession or rights either of permanent or temporary nature on a land or built up property of local body or state/ central Government.
-
“Enclosed Staircase”- means a staircase separated by fire resistant walls and doors from the rest of the building.
-
“Existing Building”- A building or structure existing authorisedly with the approval of the Authority before the commencement of these Bye-Laws.
-
“Existing Use”- Use of a building or structure existing authorisedly with the approval of the Authority before the commencement of these Bye-Laws.
-
“Exit”- A passage channel or means of egress from the building, its storey or floor to a street or, other open space of safety; whether horizontal, outside and vertical exits meaning as under:-
i) Horizontal exit means an exit, which is a protected opening through or around a fire well or bridge connecting two or more buildings.
ii) Outside exit mean an exit from building to a public way to an open area leading to a public way or to an enclosed fire resistant passage leading to a public way.
iii) Vertical exit means an exit used for ascending or descending between two or more levels including stairway, fire towers, ramps and fire escapes.
-
“External Wall”- An outer wall of a building not being a party wall even though adjoining to a wall of another building and also means a wall abutting on an interior open space of any building.
-
“Floor”- The lower surface in a storey on which one normally walks in a building, and does not include a mezzanine floor. The floor at ground level with direct access to a street or open space shall be called the ground floor; the floor above it shall be termed as floor- 1, with the next higher floor being termed as floor- 2, and so on upwards.
-
“Floor Area Ratio (FAR)”- The quotient obtained by dividing the combined covered area (plinth area) of all floors, excepting areas specifically exempted under these regulations, by the total area of the plot, viz.: -
Definitions
Tota1 Covered Area on All Floors