3.4.1 Residential Use Zone
The residential areas are developed either as
a) Plotted development or
b) Group housing/flatted development.
The density pattern i.e. (high density, high medium density, low medium density or low density) are followed for working out the pattern of development with respect to:
i) Size of the plot
ii) Number of dwelling units on each plot
iii) Setbacks
iv) FAR
v) Number of storeys/ height of the building
The municipal and social infrastructure as per the norms and standards specified in the Master Plan shall be provided. The various sites/plots required for social and municipal infrastructure are to be indicated in the layout plans. The development norms for different use/activities and on different sizes of plots are applied for sanctioning of the plans. These are based on development control rules applicable to the city/town.
3.4.2 Buildings within the Residential Use Zone
Buildings for various uses/activities within the residential use zone forming part of the residential layout plan are to be constructed with the norms of the coverage, FAR, height and others as applicable to that size of a residential plot.
3.4.3 Residential Premises – Plotted Housing
The layout plans for residential scheme shall be formulated keeping in view:
Development Codes
i) that there should be sufficient daylight and fresh air in the habitable areas within the buildings, when constructed.
ii) that there would be protection against noise, dust and local hazards
iii) that there should be sufficient open space for various family needs and in accordance with the provisions of clause 4.26, 4.27 and 4.28.
iv) that the circulation and access is easy and is safe from accident point of view
v) that, as far as possible, the plots are of regular shape and size and
vi) these are logically arranged in a systematic manner so as to give a regular pattern of development in the form of row houses, detached and semi-detached houses and if necessary the regular bungalow type plots.
The plot size may vary depending upon the type of the housing, needed for a particular city based on general affordability of the people. The size of the plot would also depend on the number of dwelling units to be permitted on each plot. Normally, a plot should be built for two dwelling units on each plot. However, on bigger size plots, more than one dwelling unit per plot can be built. For low-income group, the minimum plot size should not be less than 30 sq.mt. The following Table 3.3 is suggested for different size of the plots applicable, ground coverage, FAR, height and number of dwelling units for a residential area:
| Sl.No. | Plot Area (sq.mt) | Maximum Ground Coverage % | FAR | No. of DUs. | Maximum Height (mt.) |
|---|---|---|---|---|---|
| 1. | 30 | 75 | 150 | 1 | 8 |
| 2. | Above 30 upto 50 | 75 | 150 | 2 | 8 |
| 3. | Above 50 upto 100 | 65 | 180 | 3 | 12 |
| 4. | Above 100 upto 250 | 65 | 180 | 3 | 12 |
| 5. | Above 250 upto 500 | 55 | 165 | 6 | 15 |
| 6. | Above 500 upto 1000 | 45 | 120 | 8 | 15 |
| 7. | Above 1000 upto 1500 | 40 | 100 | 8 | 15 |
| 8. | Above 1500 upto 3000 | 33.3 | 100 | 12 | 15 |
Note:
-
In the already developed plots the pattern of development should conform to the existing regulations.
-
Basement, if constructed, may be used for incidental use such as parking, servicing and household storage. It is not to be used as a dwelling unit.
-
The area of the basement should not be more than the ground coverage.
-
Parking as per the prescribed norms should be provided with the plot or provision should be made in the layout plan without affecting the circulation pattern.
-
50% of the open area of the plot should be used for proper landscaping and for plantation.
3.4.4 Group Housing
The number of dwelling units are calculated on the basis of the density pattern given in the development plan, taking into consideration a population of 4.5 persons per dwelling unit.
| Minimum size of the plot | 3000 sq m. |
| In hill towns | 5000 sq m. |
| Maximum ground coverage | 25% to 35% |
| Maximum FAR | 50 to 175 (higher FAR may be given depending on the pattern of development) |
| In hill areas |
Development Codes
50 (higher FAR may be given depending on the pattern of development and should not exceed 150) Maximum Height 15 m. (for plot sizes upto 4000 sq m.) 26 m. for plots above 4000 sq m. In hill areas 15 m. for all size of plots. Number of dwelling units To be calculated on the basis of the net plot area of a particular neighbourhood. This may vary between 25 DUs. to 175 DUs. per ha
-
Basement, if constructed, is to be used for parking, services and for essential household storage and for providing facilities without counting in FAR.
-
The quantum of basement may vary between 33 % to 50% of the plot area.
3.4.5 Resettlement and Slum in-situ upgradation
i) Maximum net density 250 tenements per hectare.
ii) Plot size- minimum 25 sq m. However it may be reduced to 18 sq m. with 100% coverage provided an area @ 7 sq m. per plot/tenement is clubbed with the cluster open space.
iii) Path ways:
a) 2 m. upto 30 m. in length
b) 3 m. upto 50 m. in length
| S.N. | Net Residential Density (DU/ha) | Maximum Ground Coverage (%) | FAR |
|---|---|---|---|
| 1 | 25 | 25 | 0.50 |
| 2 | 50 | 30 | 0.75 |
| 3 | 75 | 33 | 0.90 |
| 4 | 100 | 35 | 1.00 |
| 5 | 125 | 35 | 1.25 |
| 6 | 150 | 35 | 1.50 |
| 7 | 175 | 35 | 1.75 |
The size of the habitable room shall be minimum of 9.5 sqm, where there is only one room with a minimum width of 2.4m. Where there are two rooms, one of these shall be minimum of 9.5 sqm and other 7.5 sqm, with a minimum width of 2.1 m.
3.4.6 Low Income Housing
The minimum plot size shall not be less than 30 sqm.
i) It is recommended to provide cluster housing instead of single room dwelling.
ii) The minimum plot size with ground coverage not exceeding 75%, shall be minimum 40 sqm in small and medium towns and minimum 30 sqm in metropolitan cities.
iii) Plot sizes below 30 sqm and not less than 15 sqm may be permitted in case of cluster planning. In such a case the ground coverage and FAR can be 100 and 200 respectively.
iv) Size of room: Every dwelling unit should have at least two habitable rooms, first room of minimum 9 sqm and width of 2.5 m. Other room shall be min 6.5 sqm with minimum width of 2.1 m provided the total area of both the rooms shall not be less than 15.5 sqm.
Development Codes
3.4.7 Studio Apartments:
| Minimum size of plot | 2000 sqm. |
|---|---|
| Maximum Ground Coverage | 33.3% |
| Maximum FAR | 2.00 |
| Height | NR (Subject to clearance from AAI/Fire Department and Other Statutory bodies) |
| Parking | 2.0 ECS/100 sqm built up area |
Other controls for studio apartments:
i. The maximum size of the apartment shall be 60 sqm built-up.
ii. The plots shall be located on road facing minimum width of 12m.
iii. Basement, if constructed, and used only for parking, utilities and services shall not be counted towards FAR.