Chapter 2Jurisdiction / Applicability and Building Documentation Procedures
2.1 Jurisdiction of Building Bye Laws
The Building Bye-Laws shall apply to the building activity in the State/Urban Center/Town for which they are framed and the same shall be unambiguously specified in the Building Bye Laws.
It is desirable that the jurisdiction of building bye laws includes all contiguous urban settlements in an urban agglomeration
2.2 Applicability of Building Bye Laws
These building byelaws shall be applicable to all building activities and read in conjunction with the master plan/development plan/regional plan/any other statutory plan in force, if any, and notifications, if any, with regard to the same and as amended from time to time and shall be applicable for a period of FIVE years after which they shall be reviewed. Till such time the reviewed building byelaws are notified, these building byelaws will continue to be in force.
2.3 Development and part construction
Except hereinafter or otherwise provided, these Bye-Laws shall apply to all development, redevelopment, erection and/or re-erection of a building etc. as well as to the design, construction of, or reconstruction and additions and alterations to a building.
Page 13
2.4 In case of Part construction
Where the whole or part of a building is demolished or altered or reconstructed, except where otherwise specifically stipulated, these Building Bye-Laws shall apply only to the extent of the work involved.
2.5 Change of use / occupancy
Where use of a building is changed, except where otherwise specifically stipulated, these Building Bye-Laws shall apply to all parts of the building affected by the change.
2.6 Reconstruction
The reconstruction in whole or part of a building which has ceased to operate due to fire, natural collapse or demolition having been declared unsafe, or which is likely to be demolished by or under an order of the Authority as the case may be and for which the necessary certificate has been given by the Authority.
2.8Development
2.8.1 Development Permission:
No person shall carry out any development or redevelopment including sub-division on any plot or land (not forming part of any approved layout plan or scheme) or cause to be done without obtaining approval from the Authority for the layout plan.
2.8.2 Building Permit:
No person shall erect, re-erect or make addition/ alterations in any building or cause the same to be done without, first obtaining a separate building permit for each such building from the Authority.
2.8.3 Pre-Code Building Permit:
Where any building permit which has been issued by the Authority before the commencement of the Building Bye-Laws and where construction is in progress and has not been completed within the specified period from the date of such permit, the said permission shall be deemed to be sanctioned under these Bye-Laws and shall only be eligible for revalidation thereunder. Accordingly, where the validity of sanction has expired and construction has not commenced, construction shall be governed by the provisions of these Building Bye-Laws.
2.7Existing approved building
Nothing in these Bye-Laws shall require the removal, alteration or abandonment, nor prevent continuance of the lawfully established use or occupancy of an existing approved building unless, in the opinion of the Authority such a building is unsafe or
1 Interpretation
In these Bye-Laws, the use of present tense includes the future tense, the masculine gender includes the feminine and the neutral, the singular number, includes the plural and the plural includes the singular. The word person includes a corporation as an individual, writing includes printing and typing and signature includes thumb impression made by a person who cannot write, if her/ his name is written near to such thumb impression.
constitutes a hazard to the safety of adjacent property or to the occupants of the building itself.
2.9Procedure for obtaining building permit
2.9.1 Notice:
Every person who intends to erect, re-erect or make alternation in any place in a building or demolish any building shall give notice in writing to the Authority of his intention in the prescribed form (See Appendix ‘A’ and ‘A1’) and such notice shall be accompanied by plans and statements in sufficient copies. The plans may be ordinary prints on ferro-paper or any other type, one set of which shall be laminated. One set of such plans shall be released and the rest retained in the office of the Authority for record after the issue of permit or refusal as the case may be.
2.9.2 Copies of Plans and Statements:
Normally 4 copies of plan and statement shall be made available along with the notice. In case of building schemes where the clearance is required from Chief Fire Officer, the number of copies of the plans and statements accompanying the notice shall be 6. In case of sites requiring the clearance of lessor, extra copies of the plan shall be made available.
2.9.3 Information Accompanying Notice:
The notice shall be accompanied by the location plan, site plan, subdivision / layout plan, building plan, services plan, specifications and certificate of supervision, ownership title and other documents as prescribed by the Authority.
2.9.4 Documents:
Application for building permit shall be accompanied by the following documents:
Ownership Documents-lease-deed/sale-deed etc. duly accompanied by an annexed site plan; giving the physical description of the plot/property. In such cases where leasedeed has not been executed, no objection certificate from the Authority/lessor. Also an affidavit/undertaking for handing over of the land required for road widening as in Appendix ‘B’.
In case of any deviation from the terms and conditions stipulated in the lease deed/ownership document, necessary clearance from the Authority shall be obtained.
Documents required to be attached shall be as follows:
i. No objection certificate from the Authority regarding land use as per Master/Zonal Plan, if required.
ii. Approval from the Chief Inspector of Factories in case of Industrial Buildings; as well as from the Pollution Control Board, wherever required.
iii. Approval from Chief Controller of Explosives, Nagpur and Chief Fire Officer, in case of hazardous buildings.
iv. Indemnity Bond in case of proposal for the construction of a basement as given in Appendix- ‘B-1’.
v. Approval from Chief Fire Officer, in case of building defined under clause 1.16. vi (a to k) shall be required.
vi. The notice shall also be accompanied by an attested copy of house tax receipt/NOC from the Assessment Department of the local body concerned.
vii. No objection certificate from the Civil Aviation Department wherever required.
viii. Undertaking as at Appendix ‘A-5’ on non-judicial stamp paper of the amount prescribed by the Authority.
ix. In case the site falls in the built-up area declared as slum under any Act NOC from the Competent Authority, from slum clearance and land use points of view.
x. In case the application is for a Farmhouse, Motel, approval/NOC from the Competent Authority from land acquisition point of view.
xi. In case of the leasehold plots, clearance from the lessor with regard to the lease conditions shall be obtained wherever required.
xii. For individual plot, wherever required, approval of the site from the Competent Authority, if not the part of already approved layout plan.
xiii. Any other information/document, which the Authority may require in case of listed buildings or otherwise.
Other documents to be submitted in special cases shall be as follows:
xiv. For projects proposed within the Prohibited and Regulated areas as defined by AMASR Act 2010, permission /NOC from Competent Authority (NMA) shall have to be obtained as per Rules 2011 framed under the Act by submission of required documents as per rules.
Page 15
xv. Additional documents required for conservation of Heritage sites including Heritage Buildings, Heritage/Precincts and Natural Features Areas (wherever required) – as per Chapter 12.
Note: Based on the technical and support capacity, the ULB shall adopt online process of applications for building approvals along with digital formats of documents and drawings for faster and transparent process of building approvals.
2.9.5 Size of Drawing Sheets and Colouring of Plans
The size of drawing sheets shall be any of those specified in Table 2.1.
Table 2.1Drawing Sheet Sizes
Sl. No.
Designation
Trimmed Size, (mm.)
1
A0
841 x 1189
2
A1
594 x 841
3
A2
420 x 594
4
A3
297 x 420
5
A4
210 x 297
6
A5
148 x 210
2.9.6 Colouring Notations for Plans:
The plans shall be coloured as specified in Table 2.2 Further, prints of plans shall be on one side of paper only.
2.9.7 Dimensions:
All dimensions shall be indicated in metric units.
Table 2.2Colouring of Plans
Sl
Item
Site Plan
Building Plan
Document Type
White Plan
Blue Print
Ammonia
White Plan
Blue Print
Ammonia
a
b
c
d
e
f
g
h
1
Plot Lines
Thick black
Thick black
Thick black
Thick black
Thick black
Thick black
2
Existing street
Green
Green
Green
-
-
-
3
Future street, if any
Green dotted
Green dotted
Green dotted
-
-
-
4
Permissible building lines
Thick dotted black
Thick dotted black
Thick dotted black
-
-
-
5
Open spaces
No colour
No colour
No colour
No colour
No colour
No colour
6
Existing work
Black
White
Blue
Black
White
Blue
7
Work proposed to be
Yellow
Yellow
Yellow
Yellow
Yellow
8
Proposed work (see Note 1)
Red filled in
Red
Red
Red
Red
Red
9
Drainage and sewerage
Red dotted
Red dotted
Red dotted
Red dotted
Red dotted
Red dotted
10
Water supply work
Black dotted thin
Black dotted thin
Black dotted thin
Black dotted thin
Black dotted thin
Black dotted thin
Notes:
1 For entirely new construction this need not be done; for extension of an existing work this shall apply. 2 For land development, subdivision, layout, suitable colouring notations shall be used which shall be indexed.
2.10All Plans
2.10.1 i) Key Plan: A key plan drawn to a scale of not less than 1: 10,000 shall be submitted along with notice showing boundary and location of the site with respect of neighborhood land marks, in area where there is no approved layout plans.
ii) Site Plan: The site plan to be sent along with the application for permit shall be drawn to a scale of 1: l00 for plots upto 500 sq. mt. in size and on a scale of 1:500 for plots above 500 sq. mt. in size. The plan shall show as below:
a) The boundaries of the site and any contiguous land belonging to the owner thereof.
b) The position of the site in relation to neighboring street.
c) The names of the streets on which the building is proposed to be situated, if any.
d) All existing buildings standing on, over or under the site.
e) The position of the building and of all other buildings, if any, which the applicant intends to erect upon his contiguous land referred to in (a) in relation to.
i) The boundaries of the site and in case where the site has been partitioned, the boundaries of the portion; owned by the applicant and also of the portions owned by others.
ii) All adjacent streets / buildings (with number of storeys and height) and premises within a distance of 12m. of the site and of the contiguous land, if any, referred to in (a); and
iii) If there is no street within a distance of 12 mt. of the site, the nearest existing street.
f) The means of access from the street to the building, and to all other buildings, if any which the applicant intends to erect upon his contiguous land, referred to in (a).
g) Space to be left about the building to secure a free circulation of air, admission of light and access.
h) The width of the street, if any, in front, at the sides or rear of building.
i) The direction of north point relative to the plan of the buildings.
j) Any existing physical features such as well, drains, trees, over head electric supply lines etc.
k) The ground area of the whole property and the breakup of covered area on each floor with the calculation for percentage covered in each floor in terms of the total area of the plot as required under the Bye-Laws governing the coverage of the area.
l) Parking plans indicating the parking spaces wherever required.
m) Such other particulars as may be prescribed by the Authority; and
n) Building number or plot number of the property on which the building is intended to be erected.
2.11Signing of plans
2.11.1 Signing the Building Plans:
All plans before submission to the Authority shall be signed by the owner(s) and by a. A qualified Architect who has valid registration with Council of Architecture, or b. An Engineer (in case of plots upto 500 sq.m. only).
(Note : except for Standard Designs/Building Plans as shown at 2.14.1 d)
2.11.2 Layout Plans:
All layout plans before submission to the Authority shall be signed by the owner(s) (except for 2.12.1 d) and by one of the following:
a) Architect holding a valid registration with the Council of Architecture for Layout Plans of plots measuring upto 1 Ha. in size.
b) Town Planner holding valid registration with the Institute of Town Planners, India for plots measuring beyond 1 Ha.
2.10.2 Requirement in respect of building sites
a) Damp Sites
Wherever the dampness of a site or the nature of the soil renders such precautions necessary, the ground surface of the site between the walls of any building erected thereon shall be rendered damp-proof to the satisfaction of the Authority.
b) Corner Site
When the site front on two streets, the frontage would be on the street having the larger width. In cases, where the two streets are of same width, then the larger depth of the site will decide the frontage and open spaces. In such case the location of a garage (on a corner plot) if provided within the open spaces shall be located diagonally opposite the point of intersection.
c) Minimum Size of Site
The minimum size of sites for the construction of different types of building or different use groups, shall be in accordance with provisions of the Master Plan and any land development Rules and Regulations of the Authority.
d) Distance from Electric Line
The distance in accordance with the current electricity rules and its amendments from time to time is to be provided between the building and overhead electric supply line.
Table 2.3Clearances from Electric Supply Lines
Type of Supply Line
Vertical clearance
Horizontal clearance
a) Low and medium voltage lines and service lines
2.50 m.
1.20 m.
b) High voltage lines upto and including 11,000 volts
3.70 m.
1.20 m.
c) High voltage lines above 11,000 volts and upto and including 33,000 volts
3.70 m.
2.00 m.
d) Extra high voltage lines additional 33,000 volts
3.70m. Plus 0.3 m. for every additional 33,000 V or part thereof.
2.0m. Plus 0.3 m. for every additional 33,000 V or part thereof.
2.10.3 Layout Plan:
The layout plan shall be formulated as per the norms of Master Plan and shall be approved as per the procedure followed by the Authority, under the provisions of relevant Act.
2.10.4 Landscape Plan:
Landscape plan is to be to the scale of 1:100 for plot upto 500 sq.m in size and for plots above 500 sq.m., the scale shall be 1:500, indicating the circulation and parking spaces, pathways (hard surface), greenery and plantation (soft area) etc.
2.10.5 Building Plan:
The plans of the building, elevations and sections accompanying the notice with dimensions shall be drawn to a scale of 1:50 for plots measuring upto 250 sq.m., for plots measuring above 250 sq.m. to a scale of 1:100, and for plots measuring 2000 sq.m. and above to a scale of 1:200 with details on a scale of 1:100 and shall:
a) Include floor plans of all floors together with the covered area clearly indicating the size and spacing of all frame members and sizes of rooms and the position and width of staircases, ramps and other exit ways, lift ways, lift machine room and lift pit details.
b) Show the use or occupancy of all parts of the building.
c) Show exact location of essential services, for example W.C., Sink. Bath etc.
d) Include sectional drawing showing clearly the sizes of the footings, thickness of basement wall, wall construction, size and spacing of framing members, floor slabs and roof slabs with their materials. The section shall indicate the heights of building and rooms and also the heights of the parapet and drainage and the slope of the roof. At least one section shall be taken through the staircase, kitchen and toilet, bath and W.C.
e) Show all elevations.
f) Indicate details of service privy, if any.
g) Give dimensions of the projected portions beyond the permissible building line.
h) Include terrace plan indicating the drainage and the slope of the roof.
i) Give indications of the north point relative to the plan.
j) Details of parking spaces provided.
k) Give indication of all doors, windows and other openings including ventilators with sizes in proper schedule.
l) Such other particulars as may be required to explain the proposal clearly and as prescribed by the Authority.
Notes – The requirement of 1:100 is permitted to be flexible for specific details needed for further illustration; and also for drawings for these in electronic form.
2.10.6 Building Plans for Multi-Storeyed/Special Buildings:
For multi-storeyed buildings, which are above 4 storeyed and buildings above 15 m. in height and for special buildings like assembly, institutional, industrial storage and hazardous occupancies as defined under clause 1.1. 16 (a to k) the following additional information shall be furnished/ indicated in the building plans in addition to the item (a) to (l) of Building Bye-Laws 2.10.4.
a) Access to fire appliances/vehicles with details of vehicular turning circle/and clear motorable access way around the building.
b) Size (width) of main and alternate staircase along with balcony approach, corridor, ventilated lobby approach.
i) Details of building services-air conditioning system with position of dampers, mechanical ventilation system, electrical services, boilers, gas pipes etc.
j) Details of exits including provision of ramps, etc. for hospitals and special risks.
k) Location of generator, transformer and switchgear room.
l) Smoke exhaust system if any.
m) Details of fire alarm system network.
n) Location of centralized control, connecting all fire alarm systems, built-in fire protection arrangements and public address system, etc.
o) Location and dimension of static water storage tank and pump room.
p) Location and details of fixed fire protection installations such as sprinklers, wet risers, hose reels, drenchers, CO installation etc.
q) Location and details of first aid firefighting equipment/installation.
r) The proper signs/symbols and abbreviation of all fire fighting systems shall be shown as per the relevant B.I.S. Codes.
2.10.7 Services Plan and Water Supply Provisions
a) Plans, elevations and sections of private water supply, sewage disposal system and details of building services, where required by the Authority, shall be made available to a scale not less than 1: 100.
Page 19
b) For residential plots more than 2000 sq.m. and non-residential plots more than 1 hectare in size, the following provisions shall be made:
i) Separate conveying system to be provided for sewerage and sullage to facilitate reuse of sullage water for gardening and washing purposes. This may require suitable storage facilities that are to be indicated on the building plans
ii) For recharging ground water, rainwater-harvesting provisions are to be provided within the plot, which are to be indicated on the building plans.
2.10.8 Besides the normal drawings, which are submitted for the sanction of any building, a proper landscape plan, a circulation plan indicating vehicular and pedestrian movement and parking and an urban design scheme where necessary, shall be submitted for sanction by the Authority
2.10.9 Specifications: General specification of the proposed construction giving type and grade of material proposed to be used in the form given in Appendix ‘A-2’ duly signed by the engaged Competent Professional for building plan design (as per Appendix ‘E’) may be shown accompanying the notice as the case may be.
2.10.10Supervision and Execution of Drainage / Sanitary works: A certificate of supervision and execution of drainage/sanitary works shall further accompany notice in the prescribed form given in Appendix ‘A-3’, by the engaged Competent Professional for building plan design (as per Appendix ‘E’) as the case may be.
2.12Notice for alteration
When the notice is only for an alteration of the building only such plans and statement as may be necessary, shall accompany the notice.
2.12.1 No notice and building permit, is necessary for the following alterations, which do not otherwise violate any provisions regarding general building requirements, structural stability and fire safety requirements of these Bye-Laws;
a) Plastering and patch repairs;
b) Re-roofing or renewals of roof including roof of intermediate floors at the same height;
c) Flooring and re-flooring;
d) Opening and closing of windows, ventilators and doors not opening towards other's properties and / or public road/property;
e) Replacing fallen bricks, stones, pillars, beams etc.
f) Construction or re-construction of sunshade not more than 75cms. in width within one's land and not overhanging over a public street;
g) Construction or re-construction of parapet not more than 1.5 m. in height and also construction or re-construction of boundary wall as permissible under these Bye-Laws;
h) White-washing, painting, etc. including erection of false ceiling in any floor at the permissible clear height provided the false ceiling in no way can be put to use as a loft etc;
i) Reconstruction of portions of buildings damaged by storm, rains, fire, earthquake or any other natural calamity to the same extent and specification as existed prior to the damage provided the use conforms to provisions of Master Plan/Zonal Plan;
j) Erection or re-erection of internal partitions provided the same are within the purview of the Bye-Laws.
2.13 Building permit fees
Building fees for covered area in plotted development/group housing; additions/alterations/revised plan; revalidation of plans; plan submission fee; for NOC/occupancy; for use of city infrastructure during the construction and other charges may be as determined by the Authority. Appendix “A-4”