5.1 High Rise
Buildings higher than 15m of height without stilts and above 17.5m of height with stilts shall be considered as high rise building.
Note: These provisions shall be in addition to the Chapter 3 for plan sanction procedure, general building requirements (low/high) given in Chapter 4 of this document and structural safety given in Chapter 6.
5.1.1 Plot Area
Plots to be used for high rise development should be located in an approved Layout plan, Comprehensive plans or sub division plans as prepared and approved by competent authorities/ as per policy of the Government of India / State Governments.
5.1.2 Means of access
a. A building shall abut on a street or streets or upon spaces directly connected from the street by a hard surface approach road, width of approach road is not less than 9 meters,
b. If there are any bends or curves on the approach road, a sufficient width shall be provided at the curve to enable the fire appliances to turn, the turning circle being at least of 9.0 m radius. Where entry to the plot is through a slip road the gate width shall not be less than 6 m for entry of the firefighting appliance.
c. The approach road to the building and open spaces on its all sides up to 6 m width and the layout for the same shall be done in consultation with Chief Fire Officer, Fire Service and the same shall be reinforced to ensure safety of the fire equipment and capable of taking the weight of Fire engine, weighing up to 45 tonnes) The said open space shall be kept free of obstructions and shall be motorable.
d. Main entrances to the premises shall be of adequate width to allow easy access to the fire engine and in no case it shall measure less than 6 m. The entrance gate shall fold back against the compound wall of the premises, thus leaving the exterior access way within the plot free for movement of fire service vehicles. If archway is provided over the main entrance the height of the archway shall not be at a height less than 5m.
e. For multistoried group housing schemes on one plot, the approach road to the site shall be minimum 18 m in width.
5.2 Peripheral Open Spaces including set backs
There shall be a space of 6 m all around up to 40m height and after that a space of 9m all around should be provided
5.3 Parking Spaces
a. The parking spaces shall be provided as per the provisions of Master Plan or Zonal plan as prevalent. The location of parking spaces shall be well ventilated.
b. In case of high-rise buildings parking will be permitted at any / all of the following:
i. Basements
ii. Stilts
iii. Podium
c. Stacked/ Multi-level/ Automated parking is also permitted.
Provisions for High-rise Development