(1) Every building having more than 15 meters height shall be provided with a lift or a ramp with an inclination of 1:10 in addition to the staircases. In all residential buildings having more than 15 meters height, lift is mandatory to
install in numbers depending on the occupancy of building.
(2) In case of public buildings with only ground floor, ramp shall be provided for differently abled persons reaching its plinth level, if public buildings are of more than one storey, lift or ramp shall be provided, but at ground floor, ramp shall be provided for reaching plinth level of building.
(3) Ramps:
(i) The ramp to basement and parking floors shall not be less than 6 meters wide for two-way traffic and 4 meters wide for one-way vehicular movement, provided with gradient not less than 1:8.
(ii) The minimum width of the ramps in hospitals shall be 2.4 meters for movement of stretcher and for public use. In no case, the hospital ramps shall be used for vehicular movement.
(iii) Ramps may also be provided in the setbacks which can be sloped considering unhindered movement of fire engine and in no case the gradient shall be less than 1:8. (to be read with basement)
(iv) All structural design/safety aspects as per latest Bureau of Indian Standards Codes as amended from time to time, shall be complied along with consideration of weight of fire engine and its maneuvering.
(v) A ramp for human movement shall have handrail on at least one side, and preferably two sides with minimum height of 0.90 meters, measured from the surface of the ramp. The handrails shall be smooth and extend to 0.30 meters beyond the top and bottom of the ramp. Where predominant movement is of children, the extra handrail shall be placed at a height of 0.76 meter.
(vi) Standards of Ramps to be referred from Fire safety perspective (Chapter 11, Model Building Bye Laws, 2016) and Harmonised Guidelines and Standards for Universal Accessibility 2021
(4) Lifts
Wherever lift is required as per bye laws, provision of at least one lift shall be made for the wheelchair users, with the following cage dimensions, recommended for passenger lift of 13 persons capacity by the Bureau of Indian Standards:
(i) Clear internal depth 1.1 meters.
(ii) Clear internal width 2.0 meters.
(iii) Entrance door width 0.9 meter.
(iv) a handrail not less than 0.6 meter long and 1 meter above floor level shall be fixed adjacent to the control panel.
(v) the minimum size of lift lobby shall be 1.8 meters x 2.0 meters or more.
(vi) the interior of the cage shall be provided with Braille symbols and audible that sounding the floor, when the cage reaches on a floor, indicating that the door of the cage for entrance/ exit is either open or closed.
Further standards of lifts shall be referred from sub para 5.4.4 of Model Building Bye-laws, 2016, wherever applicable.