(i) Type and character of building, including ancillary buildings, that may be erected or re- erected on a site and the purpose for which these may be used shall not be other than that shown in the Master Plan or Zonal Development Plan, as the case may be, or as shown in the approved layout plan of a colony or zoning plan, if any.
(ii) Where the site does not form part of a layout plan or zoning plan, the use shall be in conformity with the use prescribed in the Master Plan or Zonal Development Plan and in case no master plan notified, in that case, the use of the surrounding area will be considered and in such cases the decision of the competent authority shall be final.
(iii) Every building that may be erected or re-erected on a site, in addition to the foregoing restrictions, shall comply with the restrictions shown in the Architectural Control Sheets, wherever applicable which shall have precedence over the Building Bye-Laws.
(iv) Facade design to also incorporate Urban Design guidelines to preserve heritage conservation and city identity for the districts. Separate Urban Design guidelines need to be formulated and suitable notification need to be released for the same by the relevant authorities.
7.2Sub-division and amalgamation of plots
(i) Sub-division of a bigger plot into smaller units is permissible in the case of a family division, in case the plot is not allotted by the development agency. In case a plot has been allotted by the development agency, the prior approval of the competent authority is required. Each such subdivision shall be accessible independently through a street or a public road/street.
(ii) Except as otherwise expressly provided at the time of sale/allotment of plot in a colony under specific scheme approved by the competent authority, not more than one building unit shall be erected on any one
plot, however, two or more plots may be combined together under a single ownership for purposes of erection of one “building unit”.
Note: -
"Building unit" means a self-contained building with such outbuildings as are ordinarily ancillary to the main building used in connection therewith and physically incapable of sub-division into two or more independent building units. A building unit may, however, be owned by an individual or may be jointly and severally owned, provided it remains in a single indivisible ownership.
7.3Proportion of the site which may be covered with buildings
(1) The proportions of covered area of a building, including ancillary buildings, shall be in accordance with the categories of plots given in following sub-Codes and the remaining portion shall be left open in the form of open space around the building falling in the core area identified in the Master Plan or Zonal Development Plan or as notified by the competent authority and other than Core Area.
(2) For General Building Requirements, Chapter-4 of Model Building Bye Laws 2016 needs to be referred.
(3) Chapter 5 & 6 of Model Building Bye Laws, 2016 need to be referred for provisions of high rise and structural safety, as relevant, unless mentioned otherwise
(4) Unless specified in these building bye-Laws, DCRs, or Architecture Control Sheets, and/or urban design guidelines the minimum setbacks, permissible heights and any relevant critical sections shall be referred to from Model Building Byelaws, 2016.
(5) Restrictions based on critical areas need to be included, including Airport Authority of India, Archaeological Department, Hazard Risk Mitigation, and other critical areas need to be consulted with the relevant authorities, and NOC shall need to be obtained as the case may be.
(6) Relevant group housing requirements need to be referenced with Master Plan/DCR documents. Special provisions for construction of EWS and slums housing based on spatial impact assessment depending on the feasibility of the project, location, and impact shall be taken from Master Plan/DCR Documents. Private developers need to provide 15% for EWS and hand over
to ULB at predetermined price; similar reservations need to be explored and provided in the Group Housing wherever relevant.
(7) Core Area land use-wise permissible coverage, floor area ratio and height shall be as follows:
(i) Residential
Sr.No.
Plot area slabs in square metres
Maximum permissible Ground Coverage
Permissible basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height (G+3 Floor)(Including stilt (S+4 Floor in metres)
1.
Upto 100
85%
Single level
375 %
15.0
2
Above 100 to 500
70%
Single level
300 %
15.0
3
Above 500
60%
Single level
250%
15.0
(ii). Commercial
Sr.No.
Plot area slabs in square metres
Maximum permissible Ground Coverage
Permissible basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height
1
Upto 100
90%
Single level
500%
18
2
Above 100 to 500
80%
Upto Two level
400%
18
3
Above 500
70%
Upto Two level
340%
18
(iii). Plot setback for both core and non-core areas
The building shall not project beyond the building lines as shown in the zoning plan of respective schemes/Zonal Development Plans/ Development Control Regulations and /or indicated below the minimum setbacks shall be adhered
Sr.No.
Area of plot(in sq. metres)
Minimum FrontSetback (metres)
Minimum RearSetback (metres)
1.
Upto 50
1.0
-
2.
Above 50 to 150
1.5
1.0
3.
Above 150 to 200
2.5
1.0
4.
Above 200 to 500
3.5
1.0
5.
Above 500 square metres
3.5
3.5
(iv) For industrial or storage or mercantile (wholesale) buildings, the minimum width of setback/side open spaces shall be as follows.
Abutting Road
Plot size
Setback/ Side open space
Side 1
Side 2
Road abutting only minimum 1 side plot
Upto 150 Sqm
0
0
Above 150 to 500 sqm
0
3.5
A clear path/setback of 3.50 m is required for firefighting vehicles.
- If the industrial development/building shares a boundary with another industrial development building, no building setback is required for upto 400 sqm.
- However, no openings (e.g., windows or doors) are allowed along that shared common boundary. (This exemption is primarily a land-use efficiency measure—allowing buildings to be constructed right up to the boundary when neighboring uses are similar—while ensuring safety through the prohibition of openings on that boundary.)
(8) Area other than core area
(i) Residential: In the case of Plots; permissible coverage, floor Area ratio and height
Sr.No.
Plot area in Square Metres
Maximum permissible Ground Coverage
Permissible Basement
Maximum permissible FAR
Maximum permissible Height (G+3 Floor)(Including stilt (S+4 Floor)) (in metres)
1.
Upto 100
80%
Single level
300%
15.0
2.
Above 100 to 500
70%
Single level
280%
15.0
3.
Above 500
60%
Single level
220%
15.0
A. The additional FAR to the extent of 5% within the permissible height can be purchased at the collector's rates fixed from time to time for the respective localities.
B. Provided that the building shall conform to the restrictions contained in the zoning plans, development control regulations (DCRs) or the architectural control sheets of respective areas.
C. Provided that the 25% of the built-up area of the building not exceeding up to 50 square meters, whichever is less, can be used for non-nuisance professional consultancy services, after getting permission from the competent authority in writing. The applicant shall apply for specific use of consultancy services as mentioned in Code 3.83 in Form NAC-I along with fee as fixed from time to time and the permission shall be granted in Form NPC-II".
D. Stilt floor is permitted for parking purposes in residential and commercial plots of all sizes, subject to the condition that maximum permissible height of the building shall not exceed 15 meters.
E. Transfer of Development Rights need to be provided in accordance to Master Plan, DCRs and Zoning Regulations [that should include disaster management component, heritage preservation and conservations and other zoning regulations as required].
(ii) Group Housing
Sr.No.
Maximum permissible Ground Coverage
Permissible Basement
Maximum permissible FAR
Maximum permissible Height (G+3 Floor)(Including stilt (S+4 Floor)) (in metres)
1.
60%
Upto Two level
300 %
15.0
(iii) Commercial
Sr.No.
Type of building
Area Norm
Maximum permissible Ground Coverage
Permissible Basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height
1
Individual Shops
No Limit
As per the Architectural Control Sheets relating to facade and height controls in a street.
As per the Architectural Control Sheets relating to facade and height controls in a street.
As per the Architectural Control Sheets relating to facade and height controls in a street.
As per the Architectural Control Sheets relating to facade and height controls in a street.
2
Approved Commercial colony: includes shopping mall, multiplex, Departmental store, Integrated commercial Complex, Service Apartments, starred Hotels/ Unstarred Hotels and Guest Houses, offices.
No Limit
80%
Two levels
350%
15
3
Dhabas
500 square metres to 1/2 acre
60%
One level
100 % (with maximum 50 sqm for kiosks for other items)
5 metres
4
Banquet Hall
Minimum 2.5 acres
50%
One level
50% (10% FAR allowed for gift shop/STD Booths, Toy Centre and flower shops etc.)
15
5
Resort, Motel, Guest Houses (with/without banquet hall facilities)
No Limit
60%
Two levels
250 %
15
6
Starred Hotels, Restaurants
No Limit
80%
Two levels
400 % (with permissible 15% commercial component)
18
7
Amusement Park
No Limit
40%
One Level
100 % (with permissible 15% commercial component)
Unrestricted
8
Big retail stores
No Limit
80%
Two Levels
300%
15
(v) Industrial and IT
Sr.No.
Type of Industry
Maximum Ground Coverag
Permissible Basement
Maximum Permissible Floor Area Ratio
Maximum Permissible Height
Remarks
e
1.
General
80%
Twin level
500 %
21 Metres
--
2.
Apparel and Footwear
70%
Twin level
350 %
21 Metres
To be located on a road with Right of Way of 7 metres and above.
3.
Biotechnology other than Pharmaceuticals
70%
Twin level
350 %
21 Metres
To be located on a road with Right of Way of 7 metres and above.
4.
Information Technology/ Information Technology Enable Services
70%
Twin level
350 %
21 Metres
To be located on a road with Right of Way of 7 metres and above.
5.
Approved Information Technology Park, Cyber Park, Cyber City, Technology Park
50%
Twin Level
500 %
No Restriction
Subject to condition that the plot must be located on roads with a Right of Way of 12 metres and above.
Provided further that, the base FAR in central Business Districts (CBDs) and Transit-oriented Development (TOD) corridors shall be 6.
(vi). Warehouse
Sr. No.
Type of building
Maximum permissible Ground coverage
Maximum permissible Floor Area Ratio (FAR)
1
Integrated Inland Container Depot/Custom Bounded Area
60%
200 %
2
Warehouse other than agricultural produce/Grain Godown/Silos
3
Warehouse for Agricultural Produce/Grain Godowns/ Silos
4
Gas Go-down
(vii) Recreational
Sr.No.
Type of building
Area norms
Maximum permissible Ground coverage
Permissible basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height meters
1
Recreational site in residential zone such as Club/Community Centre including swimming pool, Badminton/Tennis / Squash Court, Indoor Games, Canteen/ Restaurant (not exceeding 300 square metres area) and related uses.Note:a. Not more than 10% of the permitted FAR to be allowed for rooms.b. Maximum 10% of the total FAR can be utilized for commercial use viz. Canteen/Restaurants.
0.5 acre to 2 acres
40%
Single level
200%
15
2
Open Space Zone such as Mini Amusement Park, Outdoor games facility, Canteen (not exceeding 200 square metres area) and related infrastructure requiring minimal construction activityNote:The overall character of the site shall be maintained as open with minimum construction to be permitted at site. However, Joy rides/ water parks etc. Installed in such projects, which are open to sky shall not be part of covered area/ FAR.
2 acres to 5 acres
10%
Single level
20%
15
Note:
A. Control of signs (hoardings) and outdoor display structures and transmission tower, telephone tower, mobile/broadband tower, and outdoor display structure.
9
Petrol
No Limit
As per terms and conditions of Oil companies.
As per terms and conditions of Oil companies.
As per terms and conditions of Oil companies.
As per terms and conditions of Oil companies.
Stations
Note: For all use cases subject to petroleum and explosive material handling, PESO regulations including Fire clearances are recommended
(iv) Institutional and Educational
Plot area slabs(Square metres)
Maximum permissible Ground Coverage
Permissible Basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height
Upto 10000
50 %
Upto two levels
300%
18
Above 10000
35 % of such portion of site
Upto two levels
300%
18
A. In the case of educational institutions (Schools/College/University), the Hostel component is restricted to 20% of maximum permissible covered area, and
B. The residential component (i.e., residential facility for principal, teachers/professors, staff, etc.) is restricted to 10% of maximum permissible covered area in addition to hostel component).
C. However, the competent authority may consider the requirement of the project for permitting residential component up to maximum limit of 50% of FAR by recording the reasons of Justification.